DIAPHRAGM VACUUM PUMPS<br />

ROUGHING PUMPS<br />

DATA SHEET E039<br />

N 813.4 ANDCB (with brushless dc motor)<br />

N 880.3 AN.22 E (with dynamic mass<br />

balancing )<br />

Concept<br />

The Diaphragm Vacuum Pumps<br />

from <strong>KNF</strong> are based on a simple<br />

principal - an elastic diaphragm,<br />

fixed on its edge, moves up and<br />

down its central point by means of<br />

an eccentric. In this way the medium<br />

is transferred using automatic<br />

valves.<br />

The pumps are equipped with the<br />

patented stress-optimized struc -<br />

tured diaphragm, resulting in a high<br />

pneumatic performance, a durable<br />

product and compact size. Special<br />

valves ensure that the product can<br />

cope easily with vapour and condensation.<br />

Several different drive motors are<br />

available. Please contact us for<br />

more information.<br />

ATEX versions available upon<br />

request.<br />

Features<br />

Uncontaminated flow<br />

No contamination of the media due<br />

to oil-free operation<br />

Maintenance-free<br />

Compact size<br />

due to structured diaphragm<br />

High performance<br />

because of structured diaphragm<br />

High level of gas tightness<br />

Long product life<br />

thanks to structured diaphragm<br />

Very quiet and little vibration<br />

Copes well with vapour and condensation<br />

Starts against vacuum<br />

May be used as roughing pumps for<br />

turbomolecular pumps<br />

Can operate in any installed position<br />

Areas of use<br />

The Diaphragm Pumps offer a high<br />

level of performance despite their<br />

small size, as well as an excellent<br />

price performance ratio. They are<br />

required especially in the fields of<br />

analysis, medicine, production<br />

technology or be used as roughing<br />

pump for turbomolecular pumps.<br />

The pumps are used for sucking<br />

gases, taking samples (even liquids<br />

in a vacuum) and evacuating vessels<br />

and systems.<br />

THE DYNAMIC MASS BALANCING<br />

For applications that demand especially<br />

smooth running throughout the<br />

whole working range of the pump,<br />

<strong>KNF</strong> has developed, and applied for<br />

patent protection on, a dynamic<br />

mass balancing. It automatically<br />

damps out the out-of- balance resulting<br />

from gas forces.<br />

PERFORMANCE DATA<br />

Type* Delivery Vacuum atm. Pressure Weight<br />

(l/min) (mbar absolute) Press. (bar g) (kg)<br />

N 813.3 ANE/DC B 13 3 1 5.9/2.34<br />

N 813.4 ANE/DC B 13 0.5 1 7.5/3.83<br />

N 813.5 ANE 19 1 1 7.5<br />

N 880.3 AN.22 E 80 2 1 18.0<br />

* E = OEM pump with ac motor, DC B = with brushless dc motor, .22 = with dynamic mass balancing


N 813.3 ANE<br />

N 813.3 ANDC B<br />

N 813.4 ANE<br />

N 813.4 ANDC B<br />

PERFORMANCE DATA<br />

Type and Order No. ** Delivery Max. operating Ultimate<br />

at atm. pressure pressure vacuum<br />

(l/min)* (bar g) (mbar abs)<br />

N 813.3 ANE 13 1 3<br />

N 813.3 ANDC B 13 1 3<br />

MOTOR DATA<br />

* Litre at STP<br />

Protection class IP 44 IP 20<br />

Voltage/Frequency (V/Hz) ~230/50 24 V dc<br />

Power P 1 (W) 50 75<br />

Operating current (A) 0.4 1.4<br />

MODEL CODES AND MATERIALS<br />

Type and Order No. ** Pump head Diaphragm Valves<br />

N 813.3 AN . . . Aluminium EPDM EPDM<br />

** See also „MODEL CODE FOR EASY ORDERING“<br />

PERFORMANCE DATA<br />

Type and Order No. ** Delivery Max. operating Ultimate<br />

at atm. pressure pressure vacuum<br />

(l/min)* (bar g) (mbar abs)<br />

N 813.4 ANE 13 1 0.5<br />

N 813.4 ANDC B 13 1 0.5<br />

* Litre at STP<br />

MOTOR DATA<br />

Protection class IP 44 IP 20<br />

Voltage/Frequency (V/Hz) ~230/50 24 V dc<br />

Power P 1 (W) 80 105<br />

Operating current (A) 0.5 2.0<br />

MODEL CODES AND MATERIALS<br />

Type and Order No. ** Pump head Diaphragm Valves<br />

N 813.4 AN . . . Aluminium EPDM EPDM<br />

Dimensions in mm (All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V)<br />

N 813.3 ANE<br />

N 813.4 ANE<br />

N 813.3 ANDC B (with brushless dc motor)<br />

N 813.4 ANDC B (with brushless dc motor)<br />

Direction of rotation<br />

90<br />

50<br />

direction of<br />

rotation<br />

Suction pumping speed<br />

Suction pumping speed<br />

Vacuum<br />

atm. Press.<br />

Vacuum<br />

atm. Press.<br />

Flow capacity l/min<br />

(Litre at STP)<br />

Flow capacity l/min<br />

(Litre at STP)<br />

Suction pumping speed m 3 /h<br />

Suction pumping speed m 3 /h<br />

mbar abs.<br />

mbar abs.<br />

Flow capacity<br />

Flow capacity<br />

Vacuum<br />

atm. Press.<br />

Vacuum<br />

atm. Press.<br />

mbar abs.<br />

mbar abs.


N 813.5 ANE<br />

N 880.3 AN.22 E<br />

With dynamic mass balancing for especially smooth running<br />

PERFORMANCE DATA<br />

Type and Order No. ** Delivery Max. operating Ultimate<br />

at atm. pressure pressure vacuum<br />

(l/min)* (bar g) (mbar abs)<br />

N 813.5 ANE 19 1 1<br />

* Litre at STP<br />

PERFORMANCE DATA<br />

Type and Order No. ** Delivery Max. operating Ultimate<br />

at atm. pressure pressure vacuum<br />

(l/min)* (bar g) (mbar abs)<br />

N 880.3 AN.22 E 80 1 2<br />

* Litre at STP<br />

MOTOR DATA<br />

Protection class IP 44<br />

Voltage/Frequency (V/Hz) ~230/50<br />

Power P 1 (W) 80<br />

Operating current (A) 0.5<br />

MODEL CODES AND MATERIALS<br />

Type and Order No. ** Pump head Diaphragm Valves<br />

N 813.5 ANE Aluminium EPDM EPDM<br />

MOTOR DATA<br />

Protection class IP 54<br />

Voltage/Frequency (V/Hz) ~230/50<br />

Power P 1 (W) 310<br />

Operating current (A) 1.6<br />

MODEL CODES AND MATERIALS<br />

Type and Order No. ** Pump head Diaphragm Valves<br />

N 880.3 AN.22 E Aluminium EPDM FPM<br />

Suction pumping speed<br />

Vacuum<br />

atm. Press.<br />

Suction pumping speed<br />

Vacuum<br />

atm. Press.<br />

Flow capacity<br />

Flow capacity<br />

Vacuum atm. Press. Vacuum atm. Press.<br />

Flow capacity l/min<br />

(Litre at STP)<br />

Flow capacity l/min<br />

(Litre at STP)<br />

Suction pumping speed m 3 /h<br />

Suction pumping speed m 3 /h<br />

mbar abs.<br />

mbar abs.<br />

mbar abs.<br />

mbar abs.


PERFORMANCE DATA<br />

Pump down time for 20 l receiver<br />

MODEL CODE FOR EASY<br />

ORDERING<br />

The model code is identical to the order<br />

number. It is set up as follows:<br />

N 880 .3 AN .22 E<br />

230 V/50 Hz,<br />

IP 54<br />

N 813.5 ANE<br />

N 813.3 ANE<br />

Base model<br />

Connection<br />

Materials<br />

Pump with dynamical<br />

mass balancing<br />

OEM versions with ac motor<br />

Other motor data, e.g.:<br />

In addition the motor data must be given<br />

in the purchase order (voltage, frequency,<br />

and protection class). In our extensive<br />

program you can be sure to find the<br />

pump you need for your particular application.<br />

N 813.4 ANE<br />

TECHNICAL DETAILS<br />

Maximum permissible gas and ambient<br />

temperature: between +5°C and +40°C.<br />

Gas-tightness of pump head:<br />

leakage rate approx. 6 x 10 -3 mbar l/s, not<br />

tested in serial production.<br />

Motors with other voltages, frequencies<br />

and protection classes on request.<br />

N 880.3 AN.22 E<br />

Accessories<br />

Description Order No. Details<br />

Silencer (for N 813...) 000346 G 1/8<br />

Silencer (for N 880.3...) 045993 G 3/8<br />

Hose connector (for N 813...) 005148 G 1/8<br />

Hose connector (for N 880.3...) 045859 G 3/8<br />

Small flange (for N 813...) 042191 G 1/8, DN 10<br />

Small flange (for N 880.3...) 045857 G 3/8, DN 16<br />

Gasket (for N 813...) 026906 for G 1/8<br />

Gasket (for N 880.3...) 044982 for G 3/8<br />

Hints on function, installation,<br />

and service: see back side.


HINTS ON FUNCTION, INSTALLATION AND SERVICE<br />

FUNCTION OF <strong>KNF</strong> DIAPHRAGM<br />

VACUUM PUMPS AND COM-<br />

PRESSORS<br />

An elastic diaphragm is moved up and<br />

down by an eccentric (see illustration).<br />

On the down-stroke it draws the air or<br />

gas being handled through the inlet valve.<br />

On the up-stroke the diaphragm forces<br />

the medium through the exhaust valve<br />

and out of the head. The compression<br />

chamber is hermetically separated from<br />

the drive mechanism by the diaphragm.<br />

The pumps transfer, evacuate and compress<br />

completely oil-free.<br />

Diaphragm pump<br />

HINTS ON INSTALLATION AND<br />

OPERATION<br />

Range of use: Transferring air and<br />

gases at temperatures between +5°C<br />

and +40°C.<br />

Permissible ambient temperature:<br />

between +5°C and +40°C.<br />

Please check the compatibility of the<br />

materials of the pump head, diaphragm<br />

and valves with the medium.<br />

The <strong>KNF</strong> product line contains pumps<br />

suitable for pumping aggressive gases<br />

and vapors - please contact us.<br />

The standard pumps are not suitable<br />

for use in areas where there is a risk of<br />

explosion. In these cases there are<br />

other products in the <strong>KNF</strong> program<br />

- please ask us for details.<br />

The pumps are designed to start<br />

against vacuum. Pumps that start<br />

against pressure are available on<br />

request.<br />

To prevent the maximum operating<br />

pressure being exceeded, restriction<br />

or regulation of the gas flow<br />

should only be carried out in the suction<br />

line.<br />

Components connected to the pump<br />

must be designed to withstand the<br />

pneumatic performance of the pump<br />

Install the pump so that the fan can<br />

draw in sufficient cooling air.<br />

Fit the pump at the highest point in the<br />

system, so that condensate cannot<br />

collect in the head of the pump.<br />

For pumps with dynamic mass balancing:<br />

the pump must be supported on<br />

rubber mounts or springs so that the<br />

natural frequency of the system is<br />

f ei >1.7 Hz. For lower values of f ei correct<br />

operation of the dynamic mass<br />

balancing cannot be guaranteed.<br />

For pumps with dynamical mass balancing:<br />

if the pump is mounted on a platform<br />

that is itself a vibrating system, or<br />

contains one, care must be taken to<br />

ensure that the two systems do not<br />

interfere with each other.<br />

HINTS ON SERVICE<br />

The diaphragm and valve plates are the<br />

only parts of the <strong>KNF</strong> diaphragm pumps<br />

subject to wear. They are easy to change,<br />

as no special tools are needed.<br />

If you have any questions, please call our<br />

application engineers (see below for contact<br />

telephone number).<br />

<strong>KNF</strong> - the competent partner for vacuum<br />

and compressor technology. Especially<br />

for unusual problems.<br />

<strong>KNF</strong> rerserves the right to make changes.<br />

<strong>KNF</strong> Neuberger GmbH<br />

Diaphragm Pumps + Systems<br />

Alter Weg 3<br />

D-79112 Freiburg<br />

Tel. ++49 (0)7664/5909-0<br />

Fax ++49 (0)7664/2124<br />

www.knf.de<br />

E-mail: info@knf.de<br />