03.04.2014 Views

ZB-1 ZB-5

ZB-1 ZB-5

ZB-1 ZB-5

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-50<br />

<strong>ZB</strong>-624<br />

polarity scale<br />

60<br />

45<br />

30<br />

15<br />

13<br />

1<br />

<strong>ZB</strong>-624<br />

<strong>ZB</strong>-1701<br />

Alternative to any 6%-Cyanopropylphenyl-94%-Dimethylpolysiloxane Phase<br />

<strong>ZB</strong>-WAX<br />

DB-624, HP-VOC, Rtx-624, Rtx-Volatiles, BP-624, Vocol,<br />

AT-624, Rtx-502.2, PE-624, 007-624, 007-502, CP-Select<br />

624 CB, Rtx-VGC, DB-VRX, Rtx-VMS, Rtx-1301, DB-1301,<br />

CP-1301<br />

<strong>ZB</strong>-FFAP<br />

<strong>ZB</strong>-624<br />

ORDERING INFORMATION<br />

• Temperature Limits: -20 to 260°C<br />

• Excellent for US EPA Methods 501.3,<br />

502.2, 503.1, 524.2, 601, 602, 8010, 8015,<br />

8020, 8240, 8260, 8021<br />

• Specifically designed for the separation<br />

of volatile organic compounds (VOCs)<br />

• Formulated for low bleed<br />

• Increased temperature limit speeds run<br />

times and re-equilibration<br />

• Widely used phase to separate volatile<br />

organic flavor and fragrance additives<br />

and residual solvents in industrial or<br />

pharmaceutical products (OVIs)<br />

• Equivalent to USP Phase G43<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

20-Meter I I I I<br />

0.18 1.00 -20 to 260 7FD-G005-22<br />

30-Meter<br />

0.25 1.40 -20 to 260 7HG-G005-27<br />

0.32 1.80 -20 to 260 7HM-G005-31<br />

0.53 3.00 -20 to 260 7HK-G005-36<br />

60-Meter<br />

0.25 1.40 -20 to 260 7KG-G005-27<br />

0.32 1.80 -20 to 260 7KM-G005-31<br />

0.53 3.00 -20 to 260 7KK-G005-36<br />

75-Meter<br />

0.53 3.00 -20 to 260 7LK-G005-36<br />

105-Meter<br />

0.53 3.00 -20 to 260 7NK-G005-36<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G005-27-B.<br />

Applications<br />

Volatile Organic Compounds (VOCs)<br />

Residual Solvents<br />

EPA Methods 524, 624, 8260<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

16<br />

Phenomenex<br />

www.phenomenex.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!