03.04.2014 Views

ZB-1 ZB-5

ZB-1 ZB-5

ZB-1 ZB-5

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ZEBRON TECHNOLOGY<br />

HIGH QUALITY<br />

• Individually QC Tested<br />

• Batch-to-Batch Reproducibility<br />

Our commitment to quality is what makes Zebron the #1 fastest<br />

growing GC column on the market. Each and every column<br />

you receive will be individually QC tested by an experienced<br />

technician. To ensure quality we evaluate important features<br />

such as bleed, activity, retention, efficiency and peak shape.<br />

Sample QC Test Chromatogram of <strong>ZB</strong>-5<br />

App ID 14894<br />

Column: Zebron <strong>ZB</strong>-5<br />

Phase: 5%-diphenyl-95%-dimethyl polysiloxane<br />

copolymer<br />

Dimensions: 30 meters x 0.25 mm x 0.25 µm<br />

Order No: 7HG-G002-11<br />

Oven Profile: Isothermal @ 140°C<br />

Carrier Gas: Hydrogen 40 cm/sec @ 140°C<br />

Flow Rate: 1.18 mL/min<br />

Injection: Split 85:1 @ 250 °C, 1.4 µL<br />

Detection: Flame Ionization (FID) 325°C<br />

Sample analyte: 1. Undecane<br />

2. 4-Chlorophenol<br />

3. Tridecane<br />

4. 1-Undecanol<br />

5. Tetradecane<br />

6. Dicyclohexylamine<br />

7. Pentadecane<br />

2 4 6 8 10 12 min<br />

k<br />

Capacity Factor [k]<br />

Plates/Meter<br />

Efficiency<br />

Pentadecane<br />

Tetradecane<br />

Tridecane<br />

Kovats Index<br />

Batch No.<br />

Film thickness is probed by measuring capacity factors<br />

Retention Index [Kovats Index]<br />

Peak Skew<br />

Batch No.<br />

Column efficiency is assessed by plates/meter determinations<br />

Peak Shape<br />

Dicyclohexylamine<br />

1-Undecanol<br />

4-Chlorophenol<br />

Batch No.<br />

Peak position or relative retention is tested by calculation<br />

of Kovats Indices<br />

Batch No.<br />

Column activity is checked by evaluating peak shape<br />

2<br />

Phenomenex<br />

www.phenomenex.com


‘‘<br />

Our initial results with the column are very good. Resolution of our standards<br />

which include many isomers have improved by 5-15%. We also noticed that<br />

column bleed is less than the HP column we used for years.<br />

Michael Quintero - King Industries<br />

‘‘<br />

ZEBRON TECHNOLOGY<br />

LOW BLEED<br />

• Lower Detection Limits<br />

• Improved Quantitation<br />

• Improved Compound Identification<br />

• Less System Maintenance<br />

Column Bleed Comparison Test by MS Detection<br />

Dimensions:<br />

Injection:<br />

Oven Program:<br />

Detector:<br />

30 meter x 0.25mm x 0.25µm<br />

225°C with a constant flow of 1.1 mL/min of helium<br />

240°C for 10 min to 280°C at 40°/min for<br />

10 min to 320°C at 40°/min for 10 min to 340°C<br />

at 40°/min for 10 min to 360°C at 40°/min for 10 min<br />

MS, Scan range: 36-450amu<br />

Lower Detection Limits and Better Quantitation<br />

EPA drinking water method 525.2 is a challenging low-level<br />

analysis where any source of noise in the mass spectra makes<br />

compound identification difficult. It is also a perfect representation<br />

of how Zebron can improve your chromatography.<br />

MS C E R T I F I E D<br />

1 Zebron <strong>ZB</strong>-5<br />

Equivalent column from leading competitors:<br />

2<br />

r 3<br />

4<br />

5<br />

Varian ® Factor Four , VF-5ms<br />

J&W ® , DB-5MS<br />

Agilent ® HP-5MS<br />

Restek ® , Rtx-5Sil MS<br />

<br />

<br />

5<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

4<br />

3<br />

2<br />

1<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Testing conditions were similar for all columns. All columns were new<br />

and obtained from the original manufacturer or its authorized channels.<br />

Data provided by Phenomenex in-house evaluations and represents<br />

bleed values obtained after 2 hours of conditioning.<br />

EPA Drinking Water<br />

Method 525.2<br />

<br />

<br />

<br />

<br />

<br />

Benzo [g, h, i] Perylene at 2ng on column<br />

S/N = 3.4<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

It is important to note that this application wasn’t run on pristine Phenomenex instruments, which had never seen real world samples! The<br />

chromatogram above was supplied to us courtesy of an actual contract lab in Indiana that runs these samples 24/7. Even at this low level (2ppm),<br />

the heaviest compounds are still detected and easily quantified.<br />

Phenomenex<br />

www.phenomenex.com<br />

3


ZEBRON TECHNOLOGY<br />

The chromatography quality and<br />

performance are excellent. Column bleed<br />

is minimal at 320°C. Peak quality remains<br />

good for 5-6 months averaging 40<br />

‘‘<br />

injection<br />

in a 24 hour period, 6-7 days per week...<br />

Kevin Walkup - Specialized Assays, Inc.<br />

‘‘<br />

HIGH TEMPERATURE STABLE<br />

• Analyze High MW Compounds<br />

• Bake Off Matrix Contaminants<br />

• Shorten Run Times<br />

The first question that people always ask is, “why does your<br />

column have such a high upper temperature limit compared<br />

to everyone else?” The technical answer is our proprietary<br />

bonding process called Engineered Self Cross-Linking (ESC).<br />

By carefully fractionating our base polymer, and using<br />

aggressive cross-linking catalysts, we produce a column that<br />

resists thermal degradation.What this means to you is that<br />

Zebron is so stable, most of the time it isn’t the polymer that<br />

breaks down, but the polyimide coating on the outside of the<br />

column.<br />

Butter Triacylglycerides<br />

Column: Zebron <strong>ZB</strong>-5<br />

Dimensions: 5meter x 0.32mm x 0.25µm<br />

Injection: On-column 60°C to 400°C<br />

at 100°C/min; 1µL<br />

Carrier Gas: Constant Flow Helium 8.0 mL/min<br />

Oven Program: 60°C to 400°C at 20°C<br />

Detection: MS @ 250°C; 21-1200amu<br />

This application was submitted by a chemical<br />

company in New York that uses 5m sections of<br />

a <strong>ZB</strong>-5 column to analyze compounds with MW<br />

>800amu! We are even impressed by the fact he<br />

routinely performs analysis that go up to 400°C!<br />

Now we don’t recommend this for everyone, but<br />

the fact is, Zebron is made to last.<br />

<br />

<br />

<br />

4<br />

Phenomenex<br />

www.phenomenex.com


IMPROVED LIFETIME AND STABILITY<br />

ZEBRON TECHNOLOGY<br />

• Improved Column Life<br />

• Analyze Dirty Samples<br />

• Save Time and Money<br />

Everyone can show low bleed or reproducible QC chromatograms; those are things we should expect from<br />

a good column manufacturer. The most important thing is how the product performs in “real world” situations!<br />

We wanted to share with you and Phenomenex the great success we had using your Zebron columns. We<br />

used 4 of your <strong>ZB</strong>-35, 30 meter columns to perform detailed pesticide analysis of soils during environmental<br />

remediation at a former Dept. of Defense facility.<br />

Over the course of 6 months, we analyzed over 6500 samples on 2 GC’s, many of these samples had<br />

‘‘<br />

high<br />

levels of pesticides and we did not use a guard column. Dan Twomey, our senior chemist and Vice President,<br />

personally performed much of the analysis and had nothing but high praise for the durability and consistency<br />

of the columns. We are attaching a photo of the extract vials for the complete project.<br />

Bob Burger - ESN North Atlantic<br />

‘‘<br />

Phenomenex<br />

www.phenomenex.com<br />

5


ZEBRON TECHNOLOGY<br />

EXCEPTIONAL CUSTOMER SERVICE<br />

• Don’t Get Put on Hold<br />

• Get Answers When You Need Them<br />

• Experienced Technical Support<br />

Have you ever called some of the other column manufacturers and been put on hold<br />

for long periods of time, only to be forced to leave a message and hope someone<br />

called you back? At Phenomenex we believe that our customers are the lifeblood of<br />

our business and that they deserve the highest level of service. We guarantee that you<br />

will always speak to an experienced representative each and every time you call.<br />

6<br />

Phenomenex<br />

www.phenomenex.com


‘‘<br />

The column has lived up to its claim as a cost effective alternative to other columns. The versatility<br />

of the column has allowed us to replace multiple columns. By doing so, time & money are saved<br />

by being able to use the Zebron for multiple tasks. Having a column like this is especially useful in a<br />

contract lab like ours where new products are continually being introduced for testing.<br />

Robert Trupp - Contract Lab, USA<br />

‘‘<br />

ZEBRON TECHNOLOGY<br />

EQUIVALENT PERFORMANCE<br />

• All The Most Popular Phases<br />

• Simple Method Transfer<br />

Each Zebron polymer was carefully developed to exhibit the<br />

same selectivity characteristics as existing products on the<br />

market. We continue to measure important factors such as<br />

Kovats Indices, tailing, capacity, and efficiency to create a<br />

product that will offer as similar chromatography as possible<br />

to the GC column you are currently using.<br />

Diesel Fuel Oil Analysis Comparison<br />

Zebron <strong>ZB</strong>-1<br />

APP ID 1328<br />

J&W ® DB-1<br />

Agilent (HP) HP-1<br />

Restek ® Rtx-1<br />

Supelco ® SPB-1<br />

Varian (Chrompack ® ) CP-Sil 5CB<br />

Test conditions same for all columns:<br />

Column: 100% dimethylpolysiloxane<br />

Dimensions: 30m x 0.25mm x 0.25µm df<br />

Injection: Split 100:1 @ 250°C<br />

Carrier Gas: Hydrogen 41.7cm/sec @ 140°C<br />

Oven Program: 40°C (2min) to 320°C @ 6°C/min (hold 5min)<br />

Detection: FID @ 325°C<br />

Sample: Diesel Fuel Oil No.2<br />

Phenomenex<br />

www.phenomenex.com<br />

7


ZEBRON TECHNOLOGY<br />

GC GUARD COLUMNS AND RETENTION GAPS<br />

Z-GUARD COLUMNS<br />

• Individually QC tested to ensure the highest<br />

level of quality<br />

• Extend column lifetime<br />

• Improve separation and peak shapes<br />

(especially early elutors)<br />

• Improve sensitivity and accuracy of<br />

quantitative results<br />

• Available as individual guard columns or as<br />

complete kits with connectors<br />

To ensure that all Z-Guards are the highest possible quality,<br />

we individually test each one! The columns are attached to<br />

a reference Zebron <strong>ZB</strong>-5 column and are tested using our<br />

specially designed QC mix. We carefully monitor activity, bleed,<br />

and stability. This way, we are able to say with confidence that<br />

Z-Guards will provide the low activity and high quality your<br />

methods require.<br />

Z-Guard Columns will trap non-volatile residues and prevent<br />

them from contaminating your expensive analytical column.<br />

When you must cut the end off the guard column to remove<br />

contaminant buildup, the integrity of your analytical column<br />

remains intact. The fused silica tubing of the guard column is<br />

without stationary phase and deactivated to provide minimal<br />

peak distortion and good wettability for polar as well as<br />

nonpolar compounds. The lifetime of your analytical column<br />

can be significantly increased by the use of a guard column.<br />

Many analysts also use the guard column as a “retention<br />

gap” to improve peak shape and quantitation. These<br />

benefits are especially enhanced when polarity<br />

mismatches between solvent and stationary phase<br />

can’t be avoided, or injection techniques like splitless,<br />

direct or on-column distort peak shape and reduce<br />

sensitivity and quantitative accuracy. The improvement<br />

in analytical results and extended column lifetimes<br />

makes the use of a guard column or retention gap a<br />

smart idea indeed!<br />

GUARD COLUMN KITS<br />

ORDERING INFORMATION<br />

ID (mm) Description Order No. Price Order No. Price<br />

I 5-Meter I 10-Meter I<br />

0.25 Guard Column 7AG-G000-00-GZ0 7CG-G000-00-GZ0<br />

Guard Column Kit 7AG-G000-00-GZK 7CG-G000-00-GZK<br />

0.32 Guard Column 7AM-G000-00-GZ0 7CM-G000-00-GZ0<br />

Guard Column Kit 7AM-G000-00-GZK 7CM-G000-00-GZK<br />

0.53 Guard Column 7AK-G000-00-GZ0 7CK-G000-00-GZ0<br />

Guard Column Kit 7AK-G000-00-GZK 7CK-G000-00-GZK<br />

Protect your GC column. Try Z-Guard<br />

with your next Zebron order.<br />

Bulk Z-Guard Columns 50 Meter<br />

ID (mm) Description Order No. Price<br />

0.25 I Guard Column I 7JG-G000-00-GZ0 I<br />

0.32 Guard Column 7JM-G000-00-GZ0<br />

0.53 Guard Column 7JK-G000-00-GZ0<br />

Multi-Pak <strong>ZB</strong>-5 Z-Guard 2 Meter<br />

ID (mm) Description Order No. Price<br />

0.25 I Zebron <strong>ZB</strong>-5 Guard Column (25/pk) I KG0-7868 I<br />

Universal GC Guard Column. Designed for use with virtually any<br />

GC Capillary column from virtually any manufacturer. Alternative to:<br />

J&W, Restek, Supelco, Agilent Technologies (HP), Alltech, Varian<br />

(Chrompack) and many more.<br />

Z-Guard Column Kits include 5 or 10 meters of deactivated fused<br />

silica tubing, 5 universal connectors and 0.5mL of high-temperature<br />

polyimide resin.<br />

8<br />

Phenomenex<br />

www.phenomenex.com


ZEBRON TECHNOLOGY<br />

GUARDIAN: INTEGRATED GUARD COLUMNS<br />

GUARDIAN SYSTEM<br />

• Eliminates the potential for leaks<br />

• Extends column life<br />

• Improves analyte focusing for low<br />

boiling compounds<br />

• Aggressively tested to ensure<br />

deactivation<br />

Guardian columns have the 5m or 10m guard built<br />

directly into the analytical column in one continuous<br />

length of tubing. Unlike traditional guard columns, which<br />

are known to be difficult to seal and prone to leaking<br />

after normal column maintenance, the Guardian<br />

system provides the same inert column protection,<br />

but eliminates the possibility of leaks.<br />

The Guardian system is excellent for environmental<br />

samples that rapidly degrade GC column performance<br />

such as EPA method 8270. The Guardian system<br />

allows routine column maintenance to be performed<br />

without worrying about creating leaks or having<br />

to update retention times when the column is cut.<br />

The “worry-free” aspect of the Guardian system<br />

makes it an essential add on to every Zebron <strong>ZB</strong>-<br />

1ms, <strong>ZB</strong>-5, and <strong>ZB</strong>-5ms column you use.<br />

GUARDIAN INTEGRATED GUARD COLUMN<br />

ORDERING INFORMATION<br />

GC Column Phase Dimensions 5m Guardian Order No. Price 10m Guardian Order No. Price<br />

<strong>ZB</strong>-1ms<br />

I I I<br />

Zebron <strong>ZB</strong>-1ms 30 meter x 0.25 mm x 0.25 df (μm) 7HG-G011-11-GGA 7HG-G011-11-GGC<br />

<strong>ZB</strong>-5ms<br />

Zebron <strong>ZB</strong>-5ms 15 meter x 0.25 mm x 0.25 df (μm) — 7EG-G010-11-GGC<br />

Zebron <strong>ZB</strong>-5ms 30 meter x 0.25 mm x 0.25 df (μm) 7HG-G010-11-GGA 7HG-G010-11-GGC<br />

Zebron <strong>ZB</strong>-5ms 30 meter x 0.25 mm x 0.50 df (μm) 7HG-G010-17-GGA —<br />

Zebron <strong>ZB</strong>-5ms 30 meter x 0.25 mm x 1.00 df (μm) — 7HG-G010-22-GGC<br />

Zebron <strong>ZB</strong>-5ms 30 meter x 0.32 mm x 1.00 df (μm) 7HM-G010-22-GGA<br />

<strong>ZB</strong>-5<br />

Zebron <strong>ZB</strong>-5 30 meter x 0.25 mm x 0.25 df (μm) 7HG-G002-11-GGA 7HG-G002-11-GGC<br />

Zebron <strong>ZB</strong>-5 30 meter x 0.25 mm x 0.50 df (μm) 7HG-G002-17-GGA 7HG-G002-17-GGC<br />

Zebron <strong>ZB</strong>-5 60 meter x 0.25 mm x 0.25 df (μm) 7KG-G002-11-GGA —<br />

Zebron <strong>ZB</strong>-5 60 meter x 0.25 mm x 0.50 df (μm) 7KG-G002-17-GGA —<br />

9


ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-1<br />

polarity scale<br />

60<br />

45<br />

30<br />

15<br />

5<br />

1<br />

<strong>ZB</strong>-1<br />

<strong>ZB</strong>-5<br />

Alternative to Any 100%-Dimethylpolysiloxane Phase<br />

<strong>ZB</strong>-35<br />

DB-1, DB-1ht, HP-1, MET-1, HP-101,HP-PONA, Rtx-1,<br />

Rtx-1 F&F, Rtx-1PONA, SPB-1, CP-Sil 5 CB, BP1, 007-1,<br />

OV-1, SE-30, AT-1, Ultra-1, DB-1 EVDX, DB-2887<br />

<strong>ZB</strong>-50<br />

<strong>ZB</strong>-1<br />

ORDERING INFORMATION<br />

• Temperature Limits: -60 to 360/370°C<br />

(Isothermal / TPGC)*<br />

• Low polarity column<br />

• Used for “fingerprinting” and routine<br />

quality control analyses<br />

(e.g., citrus oils)<br />

• Equivalent to USP Phase G2<br />

*Thicker films (≥1.0µm df) are rated to 340/360°C (Isothermal/TPGC).<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

10-Meter I I I I<br />

0.53 2.65 -60 to 340/360 7CK-G001-35<br />

15-Meter<br />

0.25 0.10 -60 to 360/370 7EG-G001-02<br />

0.25 0.25 -60 to 360/370 7EG-G001-11<br />

0.25 1.00 -60 to 360/370 7EG-G001-22<br />

0.32 0.25 -60 to 360/370 7EM-G001-11<br />

0.32 1.00 -60 to 360/370 7EM-G001-22<br />

0.53 0.15 -60 to 360/370 7EK-G001-05<br />

0.53 0.50 -60 to 360/370 7EK-G001-17<br />

0.53 1.50 -60 to 340/360 7EK-G001-28<br />

0.53 3.00 -60 to 340/360 7EK-G001-36<br />

0.53 5.00 -60 to 340/360 7EK-G001-39<br />

30-Meter<br />

0.25 0.10 -60 to 360/370 7HG-G001-02<br />

0.25 0.25 -60 to 360/370 7HG-G001-11<br />

0.25 0.50 -60 to 360/370 7HG-G001-17<br />

0.25 1.00 -60 to 340/360 7HG-G001-22<br />

0.32 0.25 -60 to 360/370 7HM-G001-11<br />

0.32 0.50 -60 to 360/370 7HM-G001-17<br />

0.32 1.00 -60 to 340/360 7HM-G001-22<br />

0.32 5.00 -60 to 340/360 7HM-G001-39<br />

0.53 0.10 -60 to 360/370 7HK-G001-02<br />

0.53 0.50 -60 to 360/370 7HK-G001-17<br />

0.53 1.50 -60 to 340/360 7HK-G001-28<br />

0.53 3.00 -60 to 340/360 7HK-G001-36<br />

<strong>ZB</strong>-624<br />

<strong>ZB</strong>-1701<br />

<strong>ZB</strong>-WAX<br />

0.53 5.00 -60 to 340/360 7HK-G001-39<br />

50-Meter<br />

0.25 0.50 -60 to 360/370 7JG-G001-17<br />

0.53 0.50 -60 to 360/370 7JK-G001-17<br />

60-Meter<br />

0.25 0.10 -60 to 360/370 7KG-G001-02 1,077<br />

0.25 0.25 -60 to 360/370 7KG-G001-11<br />

0.25 1.00 -60 to 340/360 7KG-G001-22<br />

0.32 0.10 -60 to 360/370 7KM-G001-02<br />

0.32 0.25 -60 to 360/370 7KM-G001-11<br />

0.32 1.00 -60 to 340/360 7KM-G001-22<br />

0.32 3.00 -60 to 340/360 7KM-G001-36<br />

0.53 1.50 -60 to 340/360 7KK-G001-28<br />

100-Meter<br />

0.25 0.50 -60 to 325/350 7MG-G001-17<br />

<strong>ZB</strong>-FFAP<br />

Applications<br />

Amines<br />

Ethanol<br />

Gases (refinery)<br />

MTBE<br />

Oxygenates and GRO’s<br />

PCBs<br />

Simulated distillation<br />

Solvent impurities<br />

Drugs of abuse<br />

Essential oils<br />

Hydrocarbons<br />

Natural gas odorants<br />

Pesticides<br />

Semi-volatiles<br />

Sulfur compounds (light)<br />

If you need a 5” cage, simply add a (-B) after<br />

the order number, e.g., 7HG-G001-11-B.<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

10<br />

Phenomenex<br />

www.phenomenex.com


<strong>ZB</strong>-1ms<br />

<br />

<br />

Alternative to Any MS-Certified 100%-Dimethylpolysiloxane Phase<br />

ZEBRON TECHNOLOGY<br />

60<br />

45<br />

30<br />

15<br />

polarity scale<br />

5<br />

1<br />

DB-1ms, HP-1ms, Rtx-1ms, VF-1ms, SOLGEL-1ms,<br />

CP-Sil 5CBms, Equity-1, MDN-1, AT-1ms<br />

<strong>ZB</strong>-1ms<br />

ORDERING INFORMATION<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

10-Meter I I I I<br />

0.10 0.10 -60 to 360/370 7CB-G011-02<br />

12-Meter<br />

0.20 0.33 -60 to 360/370 7DE-G011-14<br />

15-Meter<br />

0.25 0.25 -60 to 360/370 7EG-G011-11<br />

0.32 0.25 -60 to 360/370 7EM-G011-11<br />

20-Meter<br />

0.18 0.18 -60 to 360/370 7FD-G011-08<br />

25-Meter<br />

0.20 0.33 -60 to 360/370 7GE-G011-14<br />

30-Meter<br />

0.25 0.10 -60 to 360/370 7HG-G011-02<br />

0.25 0.25 -60 to 360/370 7HG-G011-11<br />

0.25 0.50 -60 to 360/370 7HG-G011-17<br />

0.25 1.00 -60 to 360/370 7HG-G011-22<br />

0.32 0.25 -60 to 360/370 7HM-G011-11<br />

0.32 1.00 -60 to 360/370 7HM-G011-22<br />

60-Meter<br />

0.25 0.25 -60 to 360/370 7KG-G011-11<br />

0.25 1.00 -60 to 360/370 7KG-G011-22<br />

0.32 1.00 -60 to 360/370 7KM-G011-22<br />

• Temperature Limits: -60 to 360/370°C<br />

(Isothermal/TPGC)*<br />

• Lowered bleed (MS-Certified) especially<br />

suited to high sensitivity GC/MS<br />

• Extremely inert for active compounds<br />

such as drugs or pesticides<br />

• Improved signal-to-noise ratio for better<br />

sensitivity and mass spectral integrity<br />

• Identical selectivity to the <strong>ZB</strong>-1<br />

• Available with Guardian Integrated<br />

Guard Columns<br />

• Equivalent to USP Phase G2<br />

*Thicker films (≥1.0µm df) are rated to 340/360°C (Isothermal/TPGC).<br />

Applications<br />

Drugs of Abuse<br />

Amines<br />

Acids<br />

Polychlorinated Biphenyls<br />

(EPA Method 1668)<br />

Flavors & Fragrances<br />

Diesel Fuel<br />

Pesticides<br />

If you need a 5” cage, simply add a (-B) after<br />

the order number, e.g., 7HG-G011-11-B.<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

11


ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-5<br />

polarity scale<br />

60<br />

45<br />

30<br />

15<br />

8<br />

1<br />

<strong>ZB</strong>-5<br />

<strong>ZB</strong>-35<br />

Alternative to Any 5%-Phenyl-95%-Dimethylpolysiloxane Phase<br />

<strong>ZB</strong>-50<br />

DB-5, HP-5,HP-5ms, HP-PAS-5, HP-5 Trace Analysis,<br />

Rtx-5, Rtx-5MS, Rtx-5Sil MS, SPB-5, MDN-5, CP-Sil 8<br />

CB, BP-5, DB-5ht, 007-5, OV-5, SE-54, AT-5, Equity-5,<br />

EC-5, Ultra-2, BP5, BPX5<br />

<strong>ZB</strong>-624<br />

• Temperature Limits: -60 to 360/370°C<br />

(Isothermal/TPGC)*<br />

• Versatile low polarity column,<br />

recommended for strongly basic<br />

and acidic compounds<br />

• Excellent choice for a confirmation<br />

column (often will separate primary<br />

column coelutors)<br />

• Analyze a wide range of volatiles,<br />

semivolatiles, antioxidants, essential<br />

oils and others<br />

• Equivalent to USP Phase G27<br />

<strong>ZB</strong>-5<br />

ORDERING INFORMATION<br />

<strong>ZB</strong>-1701<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

15-Meter I I I I<br />

0.25 0.10 -60 to 360/370 7EG-G002-02<br />

0.25 0.25 -60 to 360/370 7EG-G002-11<br />

0.25 0.50 -60 to 360/370 7EG-G002-17<br />

0.25 1.00 -60 to 340/360 7EG-G002-22<br />

0.32 0.25 -60 to 360/370 7EM-G002-11<br />

0.32 1.00 -60 to 340/360 7EM-G002-22<br />

0.53 0.50 -60 to 360/370 7EK-G002-17<br />

0.53 1.50 -60 to 340/360 7EK-G002-28<br />

<strong>ZB</strong>-WAX<br />

0.53 3.00 -60 to 340/360 7EK-G002-36<br />

20-Meter<br />

0.18 0.18 -60 to 360/370 7FD-G002-08<br />

30-Meter<br />

0.25 0.10 -60 to 360/370 7HG-G002-02<br />

0.25 0.25 -60 to 360/370 7HG-G002-11<br />

0.25 0.50 -60 to 360/370 7HG-G002-17<br />

0.25 1.00 -60 to 340/360 7HG-G002-22<br />

0.32 0.10 -60 to 360/370 7HM-G002-02<br />

0.32 0.25 -60 to 360/370 7HM-G002-11<br />

<strong>ZB</strong>-FFAP<br />

0.32 0.50 -60 to 360/370 7HM-G002-17<br />

0.32 1.00 -60 to 340/360 7HM-G002-22<br />

0.53 0.50 -60 to 360/370 7HK-G002-17<br />

0.53 1.50 -60 to 340/360 7HK-G002-28<br />

0.53 3.00 -60 to 340/360 7HK-G002-36<br />

0.53 5.00 -60 to 340/360 7HK-G002-39<br />

60-Meter<br />

0.25 0.10 -60 to 360/370 7KG-G002-02<br />

0.25 0.25 -60 to 360/370 7KG-G002-11<br />

0.25 0.50 -60 to 360/370 7KG-G002-17<br />

0.25 1.00 -60 to 340/360 7KG-G002-22<br />

0.32 0.25 -60 to 360/370 7KM-G002-11<br />

0.32 1.00 -60 to 340/360 7KM-G002-22<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G002-11-B.<br />

*Thicker films (≥1.0µm df) are rated to 340/360°C (Isothermal/TPGC).<br />

Applications<br />

Alkaloids<br />

FAMEs<br />

Phenols<br />

Residual Solvents<br />

Essential Oils/Flavors<br />

Semi-volatiles<br />

Drugs<br />

Halo-hydrocarbons<br />

Pesticides/Herbicides<br />

PCBs/Aroclors<br />

Solvent Impurities<br />

Dioxins<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

12<br />

Phenomenex<br />

www.phenomenex.com


<strong>ZB</strong>-5ms<br />

<br />

<br />

Alternative to Any 5%-Phenyl-Arylene-95%-Dimethylpolysiloxane Phase<br />

ZEBRON TECHNOLOGY<br />

polarity scale<br />

60<br />

45<br />

30<br />

15<br />

8<br />

1<br />

DB-5ms, DB-5.625, DB-5ms EVDX, VF-5ms, CP-Sil 8 CB MS<br />

<strong>ZB</strong>-5ms<br />

ORDERING INFORMATION<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

10-Meter I I I I<br />

0.10 0.10 -60 to 325/350 7CB-G010-02<br />

15-Meter<br />

0.25 0.25 -60 to 325/350 7EG-G010-11<br />

20-Meter<br />

0.18 0.18 -60 to 325/350 7FD-G010-08<br />

0.18 0.32 -60 to 325/350 7FD-G010-51<br />

0.18 0.36 -60 to 325/350 7FD-G010-53<br />

30-Meter<br />

0.25 0.25 -60 to 325/350 7HG-G010-11<br />

0.25 0.50 -60 to 325/350 7HG-G010-17<br />

0.25 1.00 -60 to 325/350 7HG-G010-22<br />

0.32 0.25 -60 to 325/350 7HM-G010-11<br />

0.32 0.50 -60 to 325/350 7HM-G010-17<br />

0.32 1.00 -60 to 325/350 7HM-G010-22<br />

60-Meter<br />

0.25 0.25 -60 to 325/350 7KG-G010-11<br />

• Temperature Limits: -60 to 325/350°C<br />

(Isothermal/TPGC)<br />

• Arylene Matrix Technology (AMT)<br />

• Guaranteed alternative to the<br />

J&W ® DB-5ms<br />

• Fully conditioned within 35 minutes<br />

• High response for acids and bases =<br />

Very low activity<br />

• Enhanced resolution of Polyaromatic<br />

Hydrocarbons (PAHs) and other multiring<br />

aromatic compounds<br />

• The perfect choice for EPA methods<br />

525, 610, 625, 8100, and 8270<br />

• Equivalent to USP Phase G27<br />

Applications<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G010-11-B.<br />

Alkaloids<br />

FAMEs<br />

Phenols<br />

Residual Solvents<br />

Essential Oils/Flavors<br />

Semi-volatiles<br />

Drugs<br />

Halo-hydrocarbons<br />

Pesticides/Herbicides<br />

PCBs/Aroclors<br />

Solvent Impurities<br />

EPA Methods<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

13


ZEBRON TECHNOLOGY<br />

polarity scale<br />

60<br />

45<br />

30<br />

18<br />

15<br />

1<br />

<strong>ZB</strong>-35<br />

<strong>ZB</strong>-35<br />

<strong>ZB</strong>-50<br />

Alternative to Any 35%-Phenyl-65%-Dimethylpolysiloxane Phase<br />

<strong>ZB</strong>-624<br />

DB-35ms, HP-35, Rtx-35, SPB-35, MDN-35, BPX35,<br />

BPX608, AT-35, 007-11, OV-11, Sup-Herb, SPB-608,<br />

Rtx-35MS, DB-35, HP-35ms, EC-35<br />

<strong>ZB</strong>-1701<br />

• Temperature Limits: 50 to 340/360°C<br />

(Isothermal/TPGC)<br />

• Intermediate polarity column, with<br />

excellent inertness to minimize analyte<br />

adsorption, improve efficiency and<br />

reproducibility<br />

• Excellent confirmatory column for<br />

organochlorine pesticides<br />

• Fast separation of PAHs, phenols and<br />

semi-volatiles up to 360°C<br />

• Improves analysis of basic as well as<br />

higher MW/BP compounds<br />

<strong>ZB</strong>-35<br />

ORDERING INFORMATION<br />

<strong>ZB</strong>-WAX<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

15-Meter I I I I<br />

0.25 0.25 50 to 340/360 7EG-G003-11<br />

0.25 0.50 50 to 340/360 7EG-G003-17<br />

0.53 1.00 50 to 340/360 7EK-G003-22<br />

30-Meter<br />

0.25 0.25 50 to 340/360 7HG-G003-11<br />

0.25 0.50 50 to 340/360 7HG-G003-17<br />

0.32 0.25 50 to 340/360 7HM-G003-11<br />

0.53 0.50 50 to 340/360 7HK-G003-17<br />

<strong>ZB</strong>-FFAP<br />

0.53 1.00 50 to 340/360 7HK-G003-22<br />

60-Meter<br />

0.25 0.25 50 to 340/360 7KG-G003-11<br />

0.32 0.25 50 to 340/360 7KM-G003-11<br />

• Excellent for trace analysis with bleedsensitive<br />

detectors (MS, FID, ECD, NPD)<br />

• Equivalent to USP Phase G42<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G003-11-B.<br />

Applications<br />

Aroclors<br />

Amines<br />

Pesticides<br />

Pharmaceuticals<br />

Semi-volatiles<br />

EPA Methods 508, 608, 8081, 8141, 8151<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

14<br />

Phenomenex<br />

www.phenomenex.com


polarity scale<br />

60<br />

45<br />

30<br />

24<br />

15<br />

1<br />

<strong>ZB</strong>-50<br />

<strong>ZB</strong>-50<br />

<strong>ZB</strong>-624<br />

Alternative to Any 50%-Phenyl-50%-Dimethylpolysiloxane Phase<br />

<strong>ZB</strong>-1701<br />

DB-17, HP-50+, Rtx-50, DB-17ht, SPB-50, SP-2250, CP-Sil<br />

24 CB, BPX50, AT-50, 007-17, DB-17, DB-17ms, DB-17 EVDX,<br />

SPB-17<br />

<strong>ZB</strong>-WAX<br />

• Temperature Limits: 40 to 320/340°C<br />

(Isothermal/TPGC)<br />

• Excellent column for CLP pesticides<br />

• Low bleed, midpolarity column<br />

• Thermally stable up to 340°C, allows<br />

high-temperature bake-out to remove<br />

contaminants<br />

• Good choice for active, thermally and<br />

chemically labile components<br />

• Great for drug screening and<br />

environmental compounds<br />

ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-50<br />

ORDERING INFORMATION<br />

<strong>ZB</strong>-FFAP<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

15-Meter I I I I<br />

0.25 0.15 40 to 320/340 7EG-G004-05<br />

0.25 0.25 40 to 320/340 7EG-G004-11<br />

0.32 0.25 40 to 320/340 7EM-G004-11<br />

0.32 0.50 40 to 320/340 7EM-G004-17<br />

0.53 1.00 40 to 320/340 7EK-G004-22<br />

30-Meter<br />

0.25 0.25 40 to 320/340 7HG-G004-11<br />

0.25 0.50 40 to 320/340 7HG-G004-17<br />

0.32 0.25 40 to 320/340 7HM-G004-11<br />

0.32 0.50 40 to 320/340 7HM-G004-17<br />

0.53 1.00 40 to 320/340 7HK-G004-22<br />

60-Meter<br />

0.25 0.25 40 to 320/340 7KG-G004-11<br />

0.25 0.50 40 to 320/340 7KG-G004-17<br />

0.32 0.25 40 to 320/340 7KM-G004-11<br />

• Equivalent to USP Phase G3<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G004-11-B.<br />

Applications<br />

Antidepressants<br />

Drugs (especially basic)<br />

Glycols<br />

Pesticides/Herbicides<br />

Steroids<br />

EPA Methods 508, 608, 8081, 8141, 8151<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

Phenomenex<br />

www.phenomenex.com<br />

15


ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-50<br />

<strong>ZB</strong>-624<br />

polarity scale<br />

60<br />

45<br />

30<br />

15<br />

13<br />

1<br />

<strong>ZB</strong>-624<br />

<strong>ZB</strong>-1701<br />

Alternative to any 6%-Cyanopropylphenyl-94%-Dimethylpolysiloxane Phase<br />

<strong>ZB</strong>-WAX<br />

DB-624, HP-VOC, Rtx-624, Rtx-Volatiles, BP-624, Vocol,<br />

AT-624, Rtx-502.2, PE-624, 007-624, 007-502, CP-Select<br />

624 CB, Rtx-VGC, DB-VRX, Rtx-VMS, Rtx-1301, DB-1301,<br />

CP-1301<br />

<strong>ZB</strong>-FFAP<br />

<strong>ZB</strong>-624<br />

ORDERING INFORMATION<br />

• Temperature Limits: -20 to 260°C<br />

• Excellent for US EPA Methods 501.3,<br />

502.2, 503.1, 524.2, 601, 602, 8010, 8015,<br />

8020, 8240, 8260, 8021<br />

• Specifically designed for the separation<br />

of volatile organic compounds (VOCs)<br />

• Formulated for low bleed<br />

• Increased temperature limit speeds run<br />

times and re-equilibration<br />

• Widely used phase to separate volatile<br />

organic flavor and fragrance additives<br />

and residual solvents in industrial or<br />

pharmaceutical products (OVIs)<br />

• Equivalent to USP Phase G43<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

20-Meter I I I I<br />

0.18 1.00 -20 to 260 7FD-G005-22<br />

30-Meter<br />

0.25 1.40 -20 to 260 7HG-G005-27<br />

0.32 1.80 -20 to 260 7HM-G005-31<br />

0.53 3.00 -20 to 260 7HK-G005-36<br />

60-Meter<br />

0.25 1.40 -20 to 260 7KG-G005-27<br />

0.32 1.80 -20 to 260 7KM-G005-31<br />

0.53 3.00 -20 to 260 7KK-G005-36<br />

75-Meter<br />

0.53 3.00 -20 to 260 7LK-G005-36<br />

105-Meter<br />

0.53 3.00 -20 to 260 7NK-G005-36<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G005-27-B.<br />

Applications<br />

Volatile Organic Compounds (VOCs)<br />

Residual Solvents<br />

EPA Methods 524, 624, 8260<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

16<br />

Phenomenex<br />

www.phenomenex.com


<strong>ZB</strong>-FFAP<br />

ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-FFAP<br />

Alternative to Any Nitroterephthalic Acid Modified Polyethylene Glycol<br />

polarity scale<br />

60<br />

58<br />

45<br />

30<br />

15<br />

1<br />

DB-FFAP, HP-FFAP, BP21, Nukol, SPB-1000, CP-Wax 58 CB,<br />

007-FFAP, Stabilwax-DA, PE-FFAP, AT-1000, EC-1000,<br />

CP-FFAP-CB<br />

• Temperature Limits: 40 to 250/260°C<br />

(Isothermal/TPGC)<br />

• High polarity column<br />

• Especially suited for organic acids, free<br />

fatty acids and alcohols<br />

• Excellent thermal and chemical stability<br />

• Bonded FFAP Phase<br />

• Replaces OV-351<br />

• Close equivalent to USP Phase G35<br />

<strong>ZB</strong>-FFAP<br />

ORDERING INFORMATION<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

15-Meter I I I I<br />

0.25 0.25 40 to 250/260 7EG-G009-11<br />

0.32 0.25 40 to 250/260 7EM-G009-11<br />

0.32 0.50 40 to 250/260 7EM-G009-17<br />

0.53 1.00 40 to 250/260 7EK-G009-22<br />

30-Meter<br />

0.25 0.25 40 to 250/260 7HG-G009-11<br />

0.32 0.25 40 to 250/260 7HM-G009-11<br />

0.32 0.50 40 to 250/260 7HM-G009-17<br />

0.53 1.00 40 to 250/260 7HK-G009-22<br />

50-Meter<br />

0.32 0.50 40 to 250/260 7JM-G009-17<br />

60-Meter<br />

0.25 0.25 40 to 250/260 7KG-G009-11<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G009-11-B.<br />

Applications<br />

Acrylates<br />

Aldehydes<br />

Ketones<br />

Organic Acids<br />

Alcohols<br />

Free Fatty Acids<br />

Volatile Free Acids<br />

Phenols<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

17


ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-624<br />

<strong>ZB</strong>-1701<br />

polarity scale<br />

60<br />

45<br />

30<br />

19<br />

15<br />

1<br />

<strong>ZB</strong>-1701<br />

DB-1701, Rtx-1701, SPB-1701, CP-Sil 19 CB,<br />

OV-1701, 007-1701, AT-1701, BP10, Equity-1701<br />

Alternative to any 14%-Cyanopropylphenyl-86%-Dimethylpolysiloxane Phase<br />

<strong>ZB</strong>-WAX<br />

<strong>ZB</strong>-FFAP<br />

• Temperature Limits: -20 to 280/300°C<br />

(Isothermal/TPGC)<br />

• Fast run and re-equilibration times<br />

for enhanced sample throughput and<br />

productivity<br />

• Provides alternate selectivity to phenyl<br />

phases with similar polarity<br />

• Equivalent to USP Phase G46<br />

<strong>ZB</strong>-1701<br />

ORDERING INFORMATION<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

15-Meter I I I I<br />

0.25 0.25 -20 to 280/300 7EG-G006-11<br />

0.32 0.25 -20 to 280/300 7EM-G006-11<br />

0.32 1.00 -20 to 280/300 7EM-G006-22<br />

30-Meter<br />

0.25 0.25 -20 to 280/300 7HG-G006-11<br />

0.25 1.00 -20 to 280/300 7HG-G006-22<br />

0.32 0.25 -20 to 280/300 7HM-G006-11<br />

0.32 1.00 -20 to 280/300 7HM-G006-11<br />

0.53 1.00 -20 to 260/280 7HK-G006-22<br />

60-Meter<br />

0.25 0.25 -20 to 280/300 7KG-G006-11<br />

0.32 0.25 -20 to 280/300 7KM-G006-11<br />

Applications<br />

Pesticides/Herbicides<br />

Alcohols<br />

Phenols<br />

Tranquilizers<br />

PCBs<br />

Aromatic Hydrocarbons<br />

PAHs<br />

Steroids<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G006-11-B.<br />

18<br />

Phenomenex<br />

www.phenomenex.com


ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-1701P<br />

Alternative to DB-1701P<br />

60<br />

45<br />

30<br />

19<br />

15<br />

DB-1701P<br />

• Temperature Limits: -20 to 280/300°C<br />

• Specially tested to ensure response<br />

of DDT, Endrin, Endrin Aldehyde, and<br />

Endrin Ketone<br />

• Guaranteed column for pesticide<br />

analysis<br />

polarity scale<br />

1<br />

• Fast run and re-equilibration times<br />

for enhanced sample throughput and<br />

productivity<br />

• EPA Method 8081A certified<br />

• Equivalent to USP Phase G46<br />

<strong>ZB</strong>-1701P<br />

ORDERING INFORMATION<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

30-Meter I I I I<br />

0.25 0.25 -20 to 280/300 7HG-G012-11<br />

0.32 0.25 -20 to 280/300 7HM-G012-11<br />

0.53 1.00 -20 to 260/280 7HK-G012-22<br />

Applications<br />

Organochlorine Pesticides<br />

Organo phosphorous Pesticides<br />

Nitrogen Containing Pesticides<br />

Aroclors<br />

Amines<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G012-11-B.<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

Phenomenex<br />

www.phenomenex.com<br />

19


ZEBRON TECHNOLOGY<br />

polarity scale<br />

60<br />

52<br />

45<br />

30<br />

15<br />

1<br />

<strong>ZB</strong>-WAX<br />

<strong>ZB</strong>-WAX<br />

<strong>ZB</strong>-FFAP<br />

Alternative to Any Polyethylene Glycol Phase<br />

HP-INNOWax, Stabilwax, FAMEWAX, CP-Wax 52 CB, 007-CW,<br />

EC-Wax, Stabilwax-DB, SOLGEL-Wax, DB-WAXetr, Met-Wax,<br />

Omegawax, BP20.<br />

• Temperature Limits: 20 to 250/260°C<br />

(Isothermal/TPGC)<br />

• Long lasting, inert, low bleed<br />

• Excellent chromatography of highly<br />

polar complex mixtures<br />

• Widely used for profiling and<br />

“fingerprinting”<br />

• Close equivalent to USP Phase G16<br />

<strong>ZB</strong>-WAX<br />

ORDERING INFORMATION<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

10-Meter I I I I<br />

0.10 0.10 20 to 250/260 7CB-G007-02<br />

15-Meter<br />

0.25 0.25 20 to 250/260 7EG-G007-11<br />

0.32 0.25 20 to 250/260 7EM-G007-11<br />

0.32 0.50 20 to 250/260 7EM-G007-17<br />

0.53 1.00 20 to 250/260 7EK-G007-22<br />

20-Meter<br />

0.18 0.18 20 to 250/260 7FD-G007-08<br />

30-Meter<br />

0.25 0.15 20 to 250/260 7HG-G007-05<br />

0.25 0.25 20 to 250/260 7HG-G007-11<br />

0.25 0.50 20 to 250/260 7HG-G007-17<br />

0.25 1.00 20 to 250/260 7HG-G007-22<br />

0.32 0.15 20 to 250/260 7HM-G007-05<br />

0.32 0.25 20 to 250/260 7HM-G007-11<br />

0.32 0.50 20 to 250/260 7HM-G007-17<br />

0.53 0.50 20 to 250/260 7HK-G007-17<br />

0.53 1.00 20 to 250/260 7HK-G007-22<br />

60-Meter<br />

0.25 0.15 20 to 250/260 7KG-G007-05<br />

0.25 0.25 20 to 250/260 7KG-G007-11<br />

0.32 0.50 20 to 250/260 7KM-G007-17<br />

0.53 1.00 20 to 250/260 7KK-G007-22<br />

Applications<br />

Acids (free)<br />

Aldehydes<br />

Essential oils<br />

Glycols<br />

Solvents<br />

Xylenes<br />

Alcohols<br />

Aromatics<br />

Flavors / Fragrances<br />

Pharmaceuticals<br />

Styrene<br />

OVIs<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G007-11-B.<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

20


ZEBRON TECHNOLOGY<br />

<strong>ZB</strong>-WAX PLUS<br />

Alternative to Any Polyethylene Glycol Phase<br />

polarity scale<br />

60<br />

52<br />

45<br />

30<br />

15<br />

1<br />

DB-WAX, HP-20M, Rtx-Wax, Supelcowax10, Carbowax Amine,<br />

Carbowax-20M, CAM, PEG 20M, AT-Wax, Permabond CW 20M,<br />

CP-Wax 57 CB<br />

• Temperature Limits: 20 to 250/260°C<br />

• Excellent chromatography of highly<br />

polar complex mixtures<br />

• Provides improved resolution of critical<br />

compounds<br />

• Specially deactivated for active<br />

compounds<br />

• Stable with 100% aqueous matrices<br />

• Bonded and solvent rinsible<br />

• Equivalent to USP Phase G16<br />

<strong>ZB</strong>-WAX PLUS<br />

ORDERING INFORMATION<br />

ID(mm) df(µm) Temp. Limits °C Order No. Price<br />

10-Meter I I I I<br />

0.10 0.10 20 to 250/260 7CB-G013-02<br />

15-Meter<br />

0.25 0.25 20 to 250/260 7EG-G013-11<br />

20-Meter<br />

0.18 0.18 20 to 250/260 7FD-G013-08<br />

30-Meter<br />

0.25 0.25 20 to 250/260 7HG-G013-11<br />

0.32 0.25 20 to 250/260 7HM-G013-11<br />

0.32 0.50 20 to 250/260 7HM-G013-17<br />

0.53 1.00 20 to 230/240 7HK-G013-22<br />

60-Meter<br />

0.25 0.25 20 to 250/260 7KG-G013-11<br />

0.32 0.50 20 to 250/260 7KM-G013-17<br />

0.53 1.00 20 to 230/240 7KK-G013-22<br />

Applications<br />

If you need a 5” cage, simply add a (-B) after the order number,<br />

e.g., 7HG-G013-11-B.<br />

Alcoholic Beverages<br />

Alcohols<br />

Aldehydes<br />

Aromatics<br />

Essential oils<br />

Flavors / Fragrances<br />

Glycols<br />

Pharmaceuticals OVIs<br />

Solvents<br />

Styrene<br />

Xylene Isomers<br />

If Zebron does not provide you with equivalent<br />

separations as compared to any other GC column<br />

of the same phase and comparable dimensions,<br />

send in your comparative data within 45 days<br />

and keep the Zebron column for FREE!<br />

Phenomenex<br />

www.phenomenex.com<br />

21


ZEBRON TECHNOLOGY<br />

GC COLUMNS CHECK STANDARDS<br />

Test the Performance of GC Columns<br />

• Suitable for Phenomenex Zebron and<br />

equivalent brands<br />

• Convenient way to check column<br />

performance<br />

• Affordable and easy to use<br />

• Sealed in 2mL glass ampules-prevent<br />

evaporation and increase shelf life<br />

• Essential tool for GC troubleshooting<br />

App ID 5162, App ID 5161<br />

App ID 14973<br />

App ID 14836 App ID 5160, App ID 10714<br />

App ID 15840<br />

Zebron <strong>ZB</strong>-1ms<br />

Order No.: AG0-7805 Price:<br />

Contains the following components (in order of elution) at ca.<br />

500µg/mL each in acetone:<br />

1. Decane<br />

2. 2-Ethylhexanoic Acid<br />

3. 4-Chlorophenol<br />

4. Naphthalene<br />

Zebron <strong>ZB</strong>-1 and <strong>ZB</strong>-5<br />

Order No.: AG0-5155 Price:<br />

Contains the following components (in order of elution)<br />

at ca. 250µg/mL each in hexane:<br />

1. Undecane 4. 1-Undecanol<br />

2. 4-Chlorophenol 5. Dicyclohexylamine<br />

3. Tridecane 6. Pentadecane<br />

Guardian Integrated Guard/<strong>ZB</strong>-5<br />

Order No.: AG0-7549 Price:<br />

Contains the following components (in order of elution) at ca.<br />

250µg/mL each in acetone:<br />

1. Decane 6. 1-Methylnaphthalene<br />

2. 2-Ethylhexanoic Acid 7. 1-Undecanol<br />

3. 1,6-Hexanediol 8. Tetradecane<br />

4. 4-Chlorophenol 9. Dicyclohexylamine<br />

5. Tridecane<br />

Zebron <strong>ZB</strong>-5ms<br />

Order No.: AG0-7578 Price:<br />

Contains the following components (in order of elution) at ca.<br />

250µg/mL each in acetone:<br />

1. Decane 6. 1-Methylnaphthalene<br />

2. 2-Ethylhexanoic Acid 7. 1-Undecanol<br />

3. 1,6-Hexanediol 8. Tetradecane<br />

4. 4-Chlorophenol 9. Dicyclohexylamine<br />

5. Tridecane 10. Pentadecane<br />

Zebron <strong>ZB</strong>-35 and <strong>ZB</strong>-1701<br />

5. Tridecane<br />

6. 1-Undecanol<br />

7. Dicyclohexylamine<br />

8. Pentadecane<br />

Order No.: AG0-5156 Price:<br />

Contains the following components (in order of elution) at ca.<br />

250µg/mL each in hexane:<br />

1. Undecane 5. 1-Undecanol<br />

2. 2,4-Dimethylphenol 6. 1-Methylnaphthalene<br />

3. 2,6-Dimethylaniline 7. Hexadecane<br />

4. Tetradecane<br />

App ID 5158 App ID 14326, App ID 5164 App ID 15815<br />

App ID 5165<br />

App ID 5163<br />

Zebron <strong>ZB</strong>-50<br />

Order No.: AG0-5157 Price:<br />

Contains the following components (in order of elution) at ca.<br />

250µg/mL each in hexane:<br />

1. Undecane 5. 1-Undecanol<br />

2. Tridecane 6. 1-Methylnaphthalene<br />

3. 2,4-Dimethylphenol 7. Hexadecane<br />

4. 2,6-Dimethylaniline<br />

Zebron <strong>ZB</strong>-624<br />

Order No.: AG0-5159<br />

Price:<br />

Contains the following components (in order of elution) at ca.<br />

1000µg/mL each in methanol:<br />

1. 1,2-Dichloropropane 4. Chlorobenzene<br />

2. Octane 5. Nonane<br />

3. Tetrachloroethylene<br />

Zebron <strong>ZB</strong>-WAXplus<br />

Order No.: AG0-7869 Price:<br />

Contains the following components (in order of elution) at ca. 250µg/mL each in hexane:<br />

1. 2-Octanone<br />

2. Tetradecane<br />

3. Pentadecane<br />

4. 1-Octanol<br />

5. Hexadecane<br />

Zebron <strong>ZB</strong>-WAX and <strong>ZB</strong>-FFAP<br />

Order No.: AG0-5158 Price:<br />

Contains the following components (in order of elution) at ca.<br />

250µg/mL each in hexane:<br />

1. 2-Octanone 6. 1-Decanol<br />

2. Tetradecane 7. Methyl dodecanoate<br />

3. 1-Octanol 8. 2,6-Dimethylaniline<br />

4. Methyl decanoate 9. 2,6-Dimethylphenol<br />

5. Methyl undecanoate<br />

Grob Test Mixture<br />

6. Methyldecanoate<br />

7. Heptadecane<br />

8. Methylundecanoate<br />

9. 1-Decanol<br />

10. Octadecane<br />

11. Methyldodecanoate<br />

12. 2,6-Dimethylaniline<br />

13. Nonadecane<br />

14. 2,6-Dimethylphenol<br />

(For most GC capillary columns)<br />

Order No.: AG0-5154 Price:<br />

Contains the following components (in order of elution) at ca. 400µg/mL each in<br />

methylene chloride:<br />

1. 2,3-Butanediol 5. 1-Nonanal 9. Methyl decanoate<br />

2. Decane 6. 2-Ethylhexanoic acid 10. Methyl undecanoate<br />

3. Undecane 7. 2,6-Dimethylphenol 11. Dicyclohexylamine<br />

4. 1-Octanol 8. 2,6-Dimethylaniline 12. Methyl dodecanoate<br />

22<br />

Phenomenex<br />

www.phenomenex.com


GC COLUMN CROSS REFERENCES<br />

ZEBRON TECHNOLOGY<br />

Phenomenex<br />

One Zebron phase is guaranteed to replace many phases from the leading manufacturers. Simply choose<br />

the phase and manufacturer you currently use and cross reference it to the guaranteed Zebron phase!<br />

J&W Agilent (HP) Restek Supelco<br />

Varian<br />

(Chrompack)<br />

Alltech SGE OV<br />

ZEBRON<br />

<strong>ZB</strong>-1<br />

DB-1,<br />

DB-1ht,<br />

DB-2887<br />

DB-1 EVDX<br />

<strong>ZB</strong>-1<br />

HP-1<br />

HP-101<br />

HP-PONA<br />

Ultra 1<br />

Rtx-1<br />

Rtx-1PONA<br />

Rtx-1F&F<br />

SE-30, SPB-1<br />

SPB-1 TG<br />

SPB-1 Sulfur<br />

SPB-HAP<br />

MET-1<br />

CP-Sil 5 CB<br />

AT-1<br />

AT-Sulfur<br />

EC-1<br />

BP-1<br />

BP1-PONA<br />

BPX1-SimD<br />

OV-1<br />

ZEBRON<br />

<strong>ZB</strong>-1MS<br />

ZEBRON<br />

<strong>ZB</strong>-5<br />

ZEBRON<br />

<strong>ZB</strong>-5MS<br />

ZEBRON<br />

<strong>ZB</strong>-35<br />

ZEBRON<br />

<strong>ZB</strong>-50<br />

ZEBRON<br />

<strong>ZB</strong>-624<br />

ZEBRON<br />

<strong>ZB</strong>-1701<br />

ZEBRON<br />

<strong>ZB</strong>-1701P<br />

ZEBRON<br />

<strong>ZB</strong>-WAX<br />

<br />

<strong>ZB</strong>-5<br />

<strong>ZB</strong>-1<br />

<br />

HP-5, HP-5ms<br />

DB-5 <strong>ZB</strong>-35<br />

Ultra 2,<br />

DB-5ms,<br />

<strong>ZB</strong>-5HP-PAS-5<br />

DB-5ht<br />

HP-5 Trace<br />

<strong>ZB</strong>-1<br />

Analysis<br />

<strong>ZB</strong>-50<br />

DB-5.625<br />

<br />

DB-5ms <strong>ZB</strong>-35<br />

DB-5ms <strong>ZB</strong>-5<br />

EVDX<br />

<strong>ZB</strong>-1<br />

<strong>ZB</strong>-624<br />

DB-35<br />

<strong>ZB</strong>-50 HP-35<br />

DB-35ms<br />

HP-35ms<br />

<strong>ZB</strong>-35<br />

<strong>ZB</strong>-5<br />

<strong>ZB</strong>-1701<br />

DB-17<br />

<strong>ZB</strong>-624<br />

DB-17ht<br />

HP-50+<br />

DB-17ms<br />

DB-17<br />

<strong>ZB</strong>-35<br />

<strong>ZB</strong>-50<br />

EVDX<br />

<strong>ZB</strong>-WAX<br />

<strong>ZB</strong>-5<br />

DB-624<br />

<strong>ZB</strong>-1701<br />

DB-1301<br />

HP-VOC<br />

<strong>ZB</strong>-624<br />

DB-VRX<br />

<strong>ZB</strong>-50<br />

<strong>ZB</strong>-FFAP<br />

<strong>ZB</strong>-35<br />

<strong>ZB</strong>-WAX<br />

<strong>ZB</strong>-1701<br />

DB-1701<br />

<strong>ZB</strong>-624<br />

<strong>ZB</strong>-50<br />

<strong>ZB</strong>-FFAP<br />

<strong>ZB</strong>-WAX<br />

<br />

DB-1701P<br />

<strong>ZB</strong>-1701<br />

<strong>ZB</strong>-624<br />

<strong>ZB</strong>-FFAP<br />

HP-INNOwax<br />

<strong>ZB</strong>-WAX<br />

DB-WAXetr<br />

HP-Wax<br />

<strong>ZB</strong>-1701<br />

DB-1ms HP-1ms Rtx-1MS<br />

Rtx-5<br />

Rtx-5MS<br />

Rtx-5Sil MS<br />

Rtx-35<br />

Rtx-35MS<br />

Rtx-50<br />

Rtx-624<br />

Rtx-1301<br />

Rtx-1701<br />

Stabilwax<br />

FAMEWAX<br />

Stabilwax-DB<br />

MDN-1<br />

Equity-1<br />

SPB-5, MDN-5<br />

PTE-5, MDN-5S,<br />

HT-5, MDN-12,<br />

PTA-5, SAC-5,<br />

Equity-5, SE-54<br />

SPB-35<br />

MDN-35<br />

SPB-608<br />

SPB-50<br />

SPB-17<br />

SP-2250<br />

SPB-624<br />

SPB-1301<br />

SPB-1701<br />

Equity-1701<br />

Met-Wax<br />

Omegawax<br />

CP-Sil 5 CB MS<br />

VF-1ms<br />

CP-Sil 8 CB<br />

CP-Sil 8 CB MS<br />

CP-Sil 8 CB MS<br />

VF-5ms<br />

AT-1ms<br />

AT-5<br />

EC-5<br />

AT-35<br />

SOLGEL-1ms<br />

BP 5<br />

BPX 5<br />

BPX 35<br />

BPX 608<br />

CP-Sil 24 CB AT-50 BPX 50<br />

CP-1301<br />

CP-Select-<br />

624-CB<br />

AT-624<br />

AT-1301<br />

BP 624<br />

OV-5<br />

OV-35<br />

OV-624<br />

CP-SIL 19 CB AT-1701 BP 10 OV-1701<br />

CP-Wax 52 CB EC-Wax BP 20<br />

ZEBRON<br />

<strong>ZB</strong>-WAX PLUS<br />

DB-WAX HP-20M<br />

<strong>ZB</strong>-FFAP<br />

<strong>ZB</strong>-WAX<br />

CAM<br />

Carbowax-20M<br />

Rtx-Wax<br />

Supelcowax 10<br />

Carbowax<br />

Amine<br />

CP-Wax 57 CB AT-Wax Carbowax-20M<br />

ZEBRON<br />

<strong>ZB</strong>-FFAP<br />

<strong>ZB</strong>-FFAP<br />

DB-FFAP HP-FFAP Stabilwax-DA<br />

Nukol<br />

SPB-1000<br />

CP-Wax 58 CB<br />

AT-1000<br />

EC-1000<br />

BP 21<br />

OV-351<br />

Phenomenex<br />

www.phenomenex.com<br />

23


3807_I<br />

PRINTED MATTER

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!