Engineering Section<br />
Housing Fits for Radial <strong>Bearing</strong>s<br />
The ISO Housing Tolerances listed are shown in the tables on pages 48 & 49<br />
Conditions Examples of Application Tolerance Displacement of Outer Ring<br />
Rotating Inner Ring<br />
Loads of all kinds<br />
General bearing applications, railroad axle<br />
bearing<br />
H6¹ Can be displaced<br />
Light and normal loads (P≤ 0.12C) with simple working<br />
conditions<br />
General bearing applications, gear<br />
transmission<br />
H8<br />
Can be displaced<br />
Heat conduction through shaft Drying cylinders G7² Can be displaced<br />
Indeterminate Direction Load*<br />
Light and normal loads (P≤ 0.12C) axial<br />
displacement of outer ring desirable<br />
Electric motors, pumps,<br />
crankshaft bearings<br />
J7<br />
Can usually be displaced<br />
Heavy shock loads Traction motors M7 Cannot be displaced<br />
Normal and heavy loads (P> 0.06C). Axial<br />
displacement of outer ring unnecessary<br />
Electrical motors, pumps, crankshaft<br />
bearings<br />
K7<br />
Cannot usually be displaced<br />
Stationary Inner Ring<br />
Normal and heavy loads (P> 0.06C) <strong>Ball</strong> bearing wheel hubs, big end bearings. N7 Cannot be displaced<br />
Light and variable loads (P≤ 0.06C) Conveyor rollers, pulleys, tension pulleys M7 Cannot be displaced<br />
Accurate or Quiet Running³<br />
Light Loads Small electric motors J6² Can be displaced<br />
*Variable external loads, shock loads, and vibratory and unbalanced loads in high-speed machinery cannot be accurately described and are classified as “indeterminate<br />
direction load”<br />
¹For large bearings (D > 250mm) and temperature difference between outer ring and housing > 10°C, use G7.<br />
²For large bearings (D > 250mm) and temperature difference between outer ring and housing > 10°C, use F7.<br />
³Not applicable to high precision bearings<br />
www.<strong>Axis</strong><strong>Bearing</strong>.com 49