Engineering Section<br />

Housing Fits for Radial <strong>Bearing</strong>s<br />

The ISO Housing Tolerances listed are shown in the tables on pages 48 & 49<br />

Conditions Examples of Application Tolerance Displacement of Outer Ring<br />

Rotating Inner Ring<br />

Loads of all kinds<br />

General bearing applications, railroad axle<br />

bearing<br />

H6¹ Can be displaced<br />

Light and normal loads (P≤ 0.12C) with simple working<br />

conditions<br />

General bearing applications, gear<br />

transmission<br />

H8<br />

Can be displaced<br />

Heat conduction through shaft Drying cylinders G7² Can be displaced<br />

Indeterminate Direction Load*<br />

Light and normal loads (P≤ 0.12C) axial<br />

displacement of outer ring desirable<br />

Electric motors, pumps,<br />

crankshaft bearings<br />

J7<br />

Can usually be displaced<br />

Heavy shock loads Traction motors M7 Cannot be displaced<br />

Normal and heavy loads (P> 0.06C). Axial<br />

displacement of outer ring unnecessary<br />

Electrical motors, pumps, crankshaft<br />

bearings<br />

K7<br />

Cannot usually be displaced<br />

Stationary Inner Ring<br />

Normal and heavy loads (P> 0.06C) <strong>Ball</strong> bearing wheel hubs, big end bearings. N7 Cannot be displaced<br />

Light and variable loads (P≤ 0.06C) Conveyor rollers, pulleys, tension pulleys M7 Cannot be displaced<br />

Accurate or Quiet Running³<br />

Light Loads Small electric motors J6² Can be displaced<br />

*Variable external loads, shock loads, and vibratory and unbalanced loads in high-speed machinery cannot be accurately described and are classified as “indeterminate<br />

direction load”<br />

¹For large bearings (D > 250mm) and temperature difference between outer ring and housing > 10°C, use G7.<br />

²For large bearings (D > 250mm) and temperature difference between outer ring and housing > 10°C, use F7.<br />

³Not applicable to high precision bearings<br />

www.<strong>Axis</strong><strong>Bearing</strong>.com 49