<strong>Certificate</strong> <strong>of</strong> <strong>Compliance</strong><br />

<strong>Certificate</strong>: 1287069 Master Contract: 203633<br />

Project: 1592771 (Edition 3) Date Issued: April 22, 2005<br />

Issued <strong>to</strong>:<br />

C.C. <strong>Technology</strong>, Inc.<br />

3201 West Wall<br />

Midland, TX 79701<br />

USA<br />

The products listed below are eligible <strong>to</strong> bear the CSA Mark shown<br />

with adjacent indica<strong>to</strong>rs 'C' and 'US'<br />

Issued by:<br />

Marty Klaassen, P. Eng.<br />

Product Certification Engineer<br />

CLASS<br />

Authorized by: Patricia Pasemko<br />

Operation Manager<br />

2258 02 - PROCESS CONTROL EQUIPMENT - For Hazardous Locations<br />

2258 82 - PROCESS CONTROL EQUIPMENT - For Hazardous Locations – Certified <strong>to</strong> US Requirements<br />

PRODUCTS<br />

CLASS I, DIVISION 1, GROUPS A, B, C, and D; Temperature Code T4A.<br />

For Canada: Ex md IIC<br />

For United States: <strong>Class</strong> I Zone 1 AEx md IIC<br />

Model Pr<strong>of</strong>lo JR Fluid Flow Alarm. Battery powered (rated 3.6Vdc nom.) and permanently mounted. FET<br />

switch rating <strong>of</strong> 300 Vdc/120 Vac @ 0.5 A. Switch closure rating <strong>of</strong> 200Vac/Vdc @ 0.5 A. Maximum Ambient<br />

<strong>of</strong> +80º C. Used with the following batteries:<br />

Type Manufacturer Part No<br />

Lithium “AA” Size Tadrian TL2100<br />

Lithium “AA” Size Tadrian TL4903<br />

Lithium “AA” Size Tadrian TL5903<br />

Lithium “AA” Size Tadrian TL5101* Fac<strong>to</strong>ry Supplied<br />

Lithium “AA” Size Tadrian TL5104<br />

Pr<strong>of</strong>lo Proximity Switch. Permanently Mounted. Temperature Code T5. “Dry Contacts” Rated: 30.0Vdc @ 0.2A<br />

max.<br />

The 'C' and 'US' indica<strong>to</strong>rs adjacent <strong>to</strong> the CSA Mark signify that the product has been evaluated <strong>to</strong> the applicable CSA and ANSI/UL Standards, for use in Canada and<br />

the U.S., respectively. This 'US' indica<strong>to</strong>r includes products eligible <strong>to</strong> bear the 'NRTL' indica<strong>to</strong>r. NRTL, i.e. National Recognized Testing Labora<strong>to</strong>ry, is a designation<br />

granted by the U.S. Occupational Safety and Health Administration (OSHA) <strong>to</strong> labora<strong>to</strong>ries which have been recognised <strong>to</strong> perform certification <strong>to</strong> U.S. Standards.<br />

FF0 2<br />

DQD 507WD 2001/08/07


<strong>Certificate</strong>: 1287069<br />

Project: 1417451<br />

Master Contract: 203633<br />

Date: April 22, 2005<br />

CLASS I, DIVISION 2, GROUPS A, B, C, and D; Temperature Code T4A.<br />

Model Pr<strong>of</strong>lo 1 Fluid Flow Moni<strong>to</strong>r. Battery powered (rated 3.0Vdc nom.) and permanently mounted. Non-<br />

Incendive and Suitable for <strong>Class</strong> I, Div. 2, Groups A, B, C and D; Hazardous Locations. Temperature Code T4A.<br />

Rated Outputs; Output Switch: 36.0Vdc @ 0.5A max. Cycle Output Switch: 36Vdc @ 0.5A max. Input Switch:<br />

“Dry Contacts Only”. Used with the following battery type:<br />

Type Manufacturer Part No.<br />

Alkaline “AA” Size Duracell MN1500<br />

Alkaline “AA” Size Kodak KAA<br />

Model Pr<strong>of</strong>lo 2 Fluid Flow Moni<strong>to</strong>r. Permanently Mounted. Non-Incendive and Suitable for <strong>Class</strong> I, Div. 2,<br />

Groups A, B, C and D; Hazardous Locations. Temperature Code T4A. Rated Input: 24.0Vdc @ 20mA Rated<br />

Outputs; Output Switch: 36.0Vdc @ 0.5A max. Cycle Output Switch: 30.0Vdc @ 40mA max. Input Switch: “Dry<br />

Contacts Only”. RS-485 communication capable<br />

APPLICABLE REQUIREMENTS<br />

The following Standards were used as a guide in the evaluation <strong>of</strong> the product covered by this report:<br />

CSA Std C22.2 No 0-M1991 - General Requirements, Canadian Electrical Code, Part II<br />

CSA Std C22.2 No 0.4-M2004 - Bonding and Grounding <strong>of</strong> Electrical Equipment (Protective Grounding)<br />

CSA Std C22.2 No 0.5-M1982 - Threaded Conduit Entries<br />

CSA Std C22.2 No 30-M1987 - Explosion-Pro<strong>of</strong> Enclosures for Use in <strong>Class</strong> I Hazardous Locations.<br />

CSA Std C22.2 No 142-M1987 - Process Control Equipment<br />

CSA Std. C22.2 No.213-M1987 - Non-Incendive Electrical Equipment for Use in <strong>Class</strong> I, Division 2<br />

(Reaffirmed 1999)<br />

CAN/CSA/UL-E60079-0:02 - Electrical apparatus for explosive gas atmospheres Part 0: General<br />

Requirements<br />

CAN/CSA/UL-E60079-1:02 - Electrical apparatus for explosive gas atmospheres Part 1:Flamepro<strong>of</strong> ”d”<br />

CAN/CSA/UL-E60079-18:02 - Electrical apparatus for explosive gas atmospheres Part 18 Encapsulation<br />

“m”<br />

ANSI/UL Standards UL 508 - Industrial Control Equipment<br />

ANSI/UL Standards UL 1203 - Explosion-Pro<strong>of</strong> and Dust-Ignition-Pro<strong>of</strong> Electrical Equipment for Use<br />

in Hazardous (<strong>Class</strong>ified) Locations<br />

ANSI/UL Standards UL1604 - Electrical Equipment for Use in <strong>Class</strong> I and II, Division 2, and <strong>Class</strong> III<br />

Hazardous (<strong>Class</strong>ified) Locations<br />

DQD 507WD 2001/08/07


Supplement <strong>to</strong> <strong>Certificate</strong> <strong>of</strong> <strong>Compliance</strong><br />

<strong>Certificate</strong>: 1287069 Master Contract: 203633<br />

The products listed, including the latest revision described below,<br />

are eligible <strong>to</strong> be marked in accordance with the referenced <strong>Certificate</strong>.<br />

Project Date Description<br />

Product Certification His<strong>to</strong>ry<br />

1287069 January 31, 2002 Original Certification <strong>of</strong> Models Pr<strong>of</strong>lo 1 and Pr<strong>of</strong>lo 2, Fluid Flow Moni<strong>to</strong>rs and<br />

Pr<strong>of</strong>lo Proximity Switch. Permanently mounted, battery and D.C. powered<br />

instruments. Non-Incendive; for <strong>Class</strong> I, Div. 2, Groups A, B, C and D,<br />

temperature code “T4A”<br />

1417451 March 6, 2003 Update <strong>to</strong> report 1287069 <strong>to</strong> update pcb and housing and corrections <strong>to</strong> report.<br />

1592771 April 22, 2005<br />

Update report <strong>to</strong> include pr<strong>of</strong>lo Jr. No Flow Alarm and Captured Proximity Switch<br />

for CSA_C_US - <strong>Class</strong> I Div 1 Groups A, B, C, D; Ex dm IIC<br />

DQD 507WD 2001/08/07


This report shall only be reproduced in full, otherwise, written permission <strong>of</strong> CSA International is required.<br />