SA Technical Datasheet v2.1
SA Technical Datasheet v2.1
SA Technical Datasheet v2.1
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>SA</strong>3216 – <strong>SA</strong>3624 – <strong>SA</strong>6432<br />
<strong>Technical</strong> <strong>Datasheet</strong><br />
Symbol Parameter Min Max Unit<br />
t c (CLK) SPI Clock frequency 0.06 2 MHz<br />
t w (CLKH) Clock high time 90 ns<br />
tw(CLKL) Clock low time 90 ns<br />
t su (D) Data input setup time 140 ns<br />
t h (D) Data input hold time 100 ns<br />
t r (CLK) Clock rise time 15 ns<br />
t f (CLK) Clock fall time 15 ns<br />
Note: In order to ensure proper<br />
synchronization to the data, if there<br />
is a permanently applied clock, the<br />
command and data bytes should<br />
follow each other either without a<br />
gap or with a gap of more than 8<br />
clock cycles.<br />
The time between data bytes may<br />
not exceed 1ms or the protocol will<br />
terminate current command.<br />
<strong>SA</strong> <strong>Technical</strong> <strong>Datasheet</strong> <strong>v2.1</strong>.doc<br />
16 of 31