<strong>SA</strong>3216 – <strong>SA</strong>3624 – <strong>SA</strong>6432<br />

<strong>Technical</strong> <strong>Datasheet</strong><br />

Symbol Parameter Min Max Unit<br />

t c (CLK) SPI Clock frequency 0.06 2 MHz<br />

t w (CLKH) Clock high time 90 ns<br />

tw(CLKL) Clock low time 90 ns<br />

t su (D) Data input setup time 140 ns<br />

t h (D) Data input hold time 100 ns<br />

t r (CLK) Clock rise time 15 ns<br />

t f (CLK) Clock fall time 15 ns<br />

Note: In order to ensure proper<br />

synchronization to the data, if there<br />

is a permanently applied clock, the<br />

command and data bytes should<br />

follow each other either without a<br />

gap or with a gap of more than 8<br />

clock cycles.<br />

The time between data bytes may<br />

not exceed 1ms or the protocol will<br />

terminate current command.<br />

<strong>SA</strong> <strong>Technical</strong> <strong>Datasheet</strong> <strong>v2.1</strong>.doc<br />