11.04.2014 Views

A breakthrough in carpal ligament release

A breakthrough in carpal ligament release

A breakthrough in carpal ligament release

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Palmar arch suppressor<br />

VideoEndoscope<br />

Slotted cannula<br />

ECTRA II System allows endoscopic<br />

<strong>carpal</strong> tunnel access<br />

Palmar arch<br />

suppressor<br />

VideoEndoscope<br />

Serves to depress and protect<br />

the palmar arch and receive<br />

the obturator tip as it exits the<br />

second portal.<br />

Prevents light guide from<br />

<strong>in</strong>terfer<strong>in</strong>g with the forearm<br />

by provid<strong>in</strong>g a light post on<br />

the same side as the direction<br />

of view. This endoscope is<br />

available <strong>in</strong> an eyepiece or<br />

35 mm video format.<br />

Dissect<strong>in</strong>g obturator<br />

Slotted cannula<br />

Permits endoscopic surgery<br />

via two portals.<br />

Detachable handle<br />

Conical obturator<br />

Detachable handle<br />

Dissect<strong>in</strong>g obturator<br />

Boat nose obturator<br />

Attaches to the obturators,<br />

each mat<strong>in</strong>g perfectly with the<br />

slotted cannula for smooth<br />

<strong>in</strong>sertion <strong>in</strong>to the <strong>carpal</strong> tunnel<br />

– dissect<strong>in</strong>g, boat nose and<br />

conical.<br />

Aggressively clears the<br />

underside of the <strong>carpal</strong> <strong>ligament</strong>.<br />

Provides m<strong>in</strong>imal dissection<br />

and easy distal exit.<br />

Boat nose obturator<br />

Conical obturator<br />

Promotes easy distal exit.<br />

Probe<br />

Hand holder<br />

Probe<br />

Ma<strong>in</strong>ta<strong>in</strong>s hand <strong>in</strong> proper<br />

hyperextended position to open<br />

tunnel. Snaps on to tray for<br />

convenient system storage.<br />

Palpates the transverse<br />

<strong>carpal</strong> <strong>ligament</strong>.<br />

Blunt dissector, curved<br />

Blunt curved<br />

dissector<br />

Assists surgeon <strong>in</strong> identify<strong>in</strong>g/<br />

clear<strong>in</strong>g proximal edge of the<br />

transverse <strong>carpal</strong> <strong>ligament</strong>.<br />

Ragnell retractors<br />

Ragnell retractors (2)<br />

Provide surgeon with control to<br />

hold entry portal open prior to<br />

cannula placement.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!