JOHN EDWARDS & ASSOCIATES<br />

ENGINEERING CONSULTANTS<br />

19 ASHLEIGH ROAD, SOLIHULL, WEST MIDLANDS B91 1AE.<br />

TELEPHONE: +44(0)121 705 1228 FAX: +44(0)121 705 4890<br />

E-mail: emas.john@dial.pipex.com<br />

15th March 1999<br />

Testing of Iseki 90mm Vacuum Interface Valves<br />

to BS EN 1091 : 1977<br />

This is to confirm that I have witnessed the testing of a 90mm Iseki Vacuum<br />

Interface valve under simulated working conditions to the requirements of BS EN<br />

1091 : 1997, in particular the requirements of para 7.1.2. The valve completed<br />

250,000 cycles without maintenance and was still working completely<br />

satisfactorily when the test was terminated. Subsequent strip down of the valve<br />

revealed negligible wear in all the moving parts.<br />

John Edwards<br />

Chartered Engineer<br />

Registered Quality Lead Assessor<br />

PRINCIPAL J. H. EDWARDS M.B.E., B.A., C.ENG., F.I.MECH.E., M.I.MGT., M.I.Q.A.<br />