14.04.2014 Views

dewe-43 universal usb instrument - DEWETRON Download Center

dewe-43 universal usb instrument - DEWETRON Download Center

dewe-43 universal usb instrument - DEWETRON Download Center

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.<strong>dewe</strong>tron.com<br />

UNIVERSAL USB INSTRUMENT<br />

The high end <strong>DEWETRON</strong><br />

performance with the easy of<br />

use DEWESoft, the entry product with<br />

8 analog multi-sensor inputs<br />

8 counter inputs<br />

2 CAN-bus interfaces<br />

CPAD2 expansion for<br />

low speed temperature<br />

DEWE-<strong>43</strong><br />

DATA SHEET


www.<strong>dewe</strong>tron.com<br />

<strong>DEWETRON</strong><br />

8 COUNTER INPUTS<br />

Counter inputs can be used for measurement of brake pedal<br />

switch, speed and distance from external velocity sensor,<br />

speed of four wheels, steering wheel position and others.<br />

High quality counter inputs are able to perform basic counting,<br />

encoder measurement and frequency measurement in<br />

the famous “supercounter” mode, which dramatically increases<br />

the accuracy of counting.<br />

2 CAN BUS PORTS<br />

CAN bus inputs are able to acquire two full<br />

speed CAN bus lines to connect to vehicle<br />

CAN or connect special sensors with CAN<br />

output.


CONNECTIVITY<br />

8 ANALOG INPUTS<br />

The analog inputs are able to<br />

acquire data from sensors like<br />

pedal force sensors, brake cylinder<br />

pressure, temperature of<br />

brake discs and others.<br />

The system includes 8 simultaneous<br />

sampled 24-bit analog<br />

inputs with front-end amplifier<br />

for connecting voltage and strain<br />

sensors as well as MSI amplifiers<br />

to measure thermocouple, IEPE<br />

or other sensors.<br />

Optional low speed temperature modules<br />

<strong>DEWETRON</strong> CPAD2 series modules are connected to a CAN<br />

interface of the DEWE-<strong>43</strong> to add low speed temperature inputs.<br />

www.<strong>dewe</strong>tron.com


DEWESoft<br />

Analog Inputs<br />

The aliasing-free 24-bit A/D converter offers the best base for this precision <strong>instrument</strong>. Standard voltage and strain<br />

inputs can be expanded for any kind of temperature, vibration or high voltage sensors by using the <strong>DEWETRON</strong>-MSI<br />

(Modular Smart Interface) connectors. All MSIs are automatically recognized as soon as they are connected.<br />

Multisensor Inputs<br />

Modular Smart Interfaces for DEWE-<strong>43</strong><br />

MSI-BR-V-200<br />

MSI-BR-ACC<br />

MSI-BR-CH-50<br />

MSI-BR-TH-K<br />

MSI-BR-TH-J<br />

MSI-BR-TH-T<br />

MSI-BR-RTD<br />

200 V input adapter with DB9 connector<br />

Differential input configuration, BNC connector<br />

TEDS for automatic adapter identification<br />

IEPE adapter with DB9 connector<br />

Excitation current 4 mA at 21 V, High pass filter 1.5 Hz,<br />

BNC connector TEDS for automatic adapter identification<br />

Charge input adapter with DB9 connector range up to 50000 pC,<br />

AC coupled with 0.07 Hz, BNC signal connection,<br />

automatic adapter identification<br />

Thermocouple type K / J / T adapter with DB9 connector<br />

For use with isolated thermocouple sensors only!<br />

High accuracy cold junction reference measurement,<br />

1 m thermo cable with Mini TC connector<br />

TEDS for automatic adapter identification<br />

Pt100, Pt200, Pt500, Pt1000 and Pt2000 adapter with DB9 connector<br />

2, 3 and 4 wire connection methods,<br />

5-pin Binder 710 series connector<br />

TEDS for automatic adapter identification


A complete range of solutions<br />

for dynamic vehicle testing.<br />

SOFTWARE<br />

Counters<br />

<strong>DEWETRON</strong> has advanced the state-of-the-art in counter/encoder<br />

inputs in our data acquisition systems,<br />

improving yet again our counters.<br />

The key advancement is that our counters are PHASE<br />

SYNCHRONIZED. Referring to the diagram, you can see<br />

that a standard counter is always a sample behind. With<br />

software interpolation you can get closer, but only with<br />

<strong>DEWETRON</strong>’s advanced time shifting technology are<br />

both the phase and amplitude fully corrected!<br />

ADC-clock<br />

Counter input<br />

Ideal counting<br />

<strong>DEWETRON</strong> counter<br />

Software interpolation<br />

Standard counter<br />

RPM-Measurement<br />

Encoder<br />

Tacho<br />

Gearthooth, CDM<br />

Gearthooth, TRG, CDM and TRG<br />

Gearthooth with missing teeth<br />

Gearthooth with double teeth<br />

Length-Measurement<br />

Linear encoder<br />

Linear pulse sensor<br />

Event Counting<br />

Basic counting<br />

Gated counting<br />

Up/down counting<br />

Waveform Timing<br />

Period frequency<br />

Two pulse edge separation<br />

Period, pulse width,<br />

frequency, duty cycle<br />

www.<strong>dewe</strong>soft.com


www.<strong>dewe</strong>tron.com<br />

<strong>DEWETRON</strong><br />

Easy-to-use<br />

Synchronous data acquisition of different<br />

sources<br />

Data export to almost any analysis package<br />

Powerful online mathematics and filtering<br />

Extensions for special applications<br />

Networkable operation with synchronization<br />

DCOM programmable extensibility<br />

DEWESoft turns your hardware into a powerful<br />

data acquisition system. Our award-winning<br />

data acquisition package is second to none<br />

when it comes to both pure recording power<br />

and ease of use. Normally this is a difficult<br />

balancing act: providing lots of capability and<br />

performance, without making the user interface<br />

hard to learn. But we‘ve done it!<br />

CAN Bus Data Recording<br />

Every automobile, truck, motorcycle, and most<br />

military vehicles and even some aircraft engines<br />

use the CAN bus. The „Controller Area Network“<br />

(CAN) is a serial bus containing hundreds of<br />

messages, each containing one or more channels<br />

of data. Cars, trucks, military vehicles,<br />

and many aircraft engines use CAN to send<br />

data about the engine, brakes, cooling system,<br />

steering system, and dozens of other parameters.<br />

CAN makes testing these machines a lot<br />

easier when you can access important parameters<br />

like the steering wheel angle, engine RPM,<br />

and wheel speeds, by connecting to the CAN<br />

bus rather than to spend hours <strong>instrument</strong>ing<br />

the vehicle! In addition, more and more sensors today output their data on this multi-device, convenient data bus, and<br />

thus the ability to record data from it becomes more and more important.<br />

<strong>DEWETRON</strong> has been on the forefront of providing a powerful yet convenient interface for recording data from the CAN<br />

bus, having introduced this in DEWESoft v5 in 2003. Today it is better and easier than ever, and we even added CAN bus<br />

interfaces to our latest ORION cards, providing up to four synchronous CAN interfaces per system. Setup is convenient,<br />

including the ability to import dbc database files, the de facto standard format for CAN channel setup.<br />

Typical CAN-bus sensor<br />

(measuring steering wheel)<br />

Vehicle CAN-bus<br />

diagnostic connector


TECHNICAL SPECIFICATIONS<br />

ANALOG INPUT<br />

Number of channels<br />

Measured values<br />

Resolution<br />

Type of ADC<br />

Sampling rate<br />

8 (simultaneously sampled)<br />

Voltage, full bridge (IEPE, charge, thermocouple and RTD with MSI adapters)<br />

24-bit<br />

Sigma-Delta<br />

DEWE-<strong>43</strong>-DSA: 204.8 kS/s (DEWE-<strong>43</strong>: 51.2 kS/s)<br />

-3 dB bandwith 76 kHz @ 204.8 kS/s (25 kHz @ 51,2 kS/s)<br />

AMPLIFIER CHARACTERISTICS<br />

Input ranges Voltage ±0.01 V, ±0.1 V, ±1 V, ±10 V<br />

Accuracy<br />

Input impedance<br />

CMRR<br />

Voltage via MSI-BR-V200<br />

Full bridge<br />

Half or quarter bridge<br />

IEPE via MSI-BR-ACC<br />

Thermocouple via<br />

MSI-BR-TH-x<br />

Pt100, Pt200, Pt500, Pt1000,<br />

Pt2000 and resistance via<br />

MSI-BR-RTD<br />

up to ±200 V<br />

±10 mV/V, ±100 mV/V, ±1000 mV/V<br />

With external bridge completion<br />

±0.1 V, ±1 V, ±10 V<br />

Full range of thermocouple type<br />

(isolated thermocouple only)<br />

±0.1 % of range, ±0.5 mV<br />

-200°C to 1000°C<br />

and 0 to 6.5 kOhm<br />

10 MΩ||33 pF (common mode), 20 MΩ||47 pF (differential mode)<br />

>80 dB<br />

Sensor supply voltage ±5 V 0.1 % @ 50 mA, 12 V @ 100 mA per channel (total max. 5W)<br />

Voltage mode coupling<br />

Overvoltage protection<br />

DYNAMIC CHARACTERISTICS<br />

Signal to noise @ fs


www.<strong>dewe</strong>tron.com<br />

<strong>DEWETRON</strong> offices worldwide<br />

North & South America<br />

Argentina<br />

Brazil<br />

Canada<br />

Chile<br />

Colombia<br />

Costa Rica<br />

Ecuador<br />

Mexico<br />

Peru<br />

USA<br />

Europe<br />

Austria<br />

Benelux<br />

Czech Republic<br />

Finland<br />

France<br />

Germany<br />

Italy<br />

Spain<br />

Sweden<br />

Switzerland<br />

Turkey<br />

United Kingdom<br />

Headquarters:<br />

Asia & Pacific<br />

Australia<br />

China<br />

India<br />

Japan<br />

New Zealand<br />

Singapore<br />

South Korea<br />

Taiwan<br />

Thailand<br />

Vietnam<br />

<strong>DEWETRON</strong> Ges.m.b.H. • Parkring 4 • 8074 Graz-Grambach • AUSTRIA<br />

(00<strong>43</strong>) 316 3070-0 • (00<strong>43</strong>) 316 3070-90 • sales@<strong>dewe</strong>tron.com<br />

DE-D080901E • All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. © <strong>DEWETRON</strong> Ges.m.b.H. 08/2009<br />

find your local distributor on www.<strong>dewe</strong>tron.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!