LEED® Credit Summary - Armstrong
LEED® Credit Summary - Armstrong
LEED® Credit Summary - Armstrong
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
CEILING&wall<br />
SYSTEMS<br />
CI/SfB<br />
(35) Xy<br />
08/2012<br />
Between us, ideas become reality ®<br />
<strong>Armstrong</strong> Ceiling Systems<br />
LEED <strong>Credit</strong> <strong>Summary</strong><br />
LEED, or Leadership in Energy and Environmental Design, is an internationallyrecognised<br />
green building certification system. Developed by the U.S Green<br />
Building Council, LEED provides building owners and operators with a framework<br />
for identifying and implementing practical and measurable green building design,<br />
construction, operations and maintenance solutions.<br />
LEED promotes sustainable building and development practices through a suite<br />
of rating systems that recognise projects that implement strategies for better<br />
environmental and health performance.<br />
LEED uses a straightforward scoring system (credits) which are supported by<br />
evidence-based science and research.<br />
The following LEED credit summary has been developed by <strong>Armstrong</strong> Ceiling<br />
Systems to support the design, specification and installation of <strong>Armstrong</strong><br />
suspended ceiling systems in a wide range of buildings.<br />
Supporting evidence is contained in Appendix 1, <strong>Armstrong</strong> Products –<br />
Environmental Performance Table and Appendix 2, <strong>Armstrong</strong> Products –<br />
Absorption Attenuation Comparison Table. These appendices cover the full range<br />
of <strong>Armstrong</strong> suspended ceiling systems.<br />
*Key:<br />
NC = New Construction and Major Renovations<br />
CS = Core & Shell Developments<br />
CI = Commercial Interiors<br />
ENERGY AND ATMOSPHERE<br />
EA <strong>Credit</strong> 1:<br />
OPTIMISE ENERGY<br />
PERFORMANCE<br />
LEED NC, Schools,<br />
CS, CI<br />
*Energy and Environmental<br />
Effects of High Light<br />
Reflectance Ceilings: Brinjac<br />
Engineering 2006<br />
Intent: Achieve increasing levels of<br />
energy performance above the baseline<br />
standard to reduce environmental and<br />
economic impacts associated with<br />
excessive energy use.<br />
How <strong>Armstrong</strong> can help:<br />
<strong>Armstrong</strong> range of mineral fibre and<br />
metal ceiling tiles achieve high levels of<br />
light reflectance. High light reflectance<br />
ceilings enhance indirect lighting by<br />
improving overall lighting uniformity<br />
returning up to 90% of the light back<br />
into the space, compared with 75% with<br />
standard ceilings*. A light reflectance of<br />
90% and more allows 20% cost savings<br />
with indirect lighting, and can yield total<br />
building energy savings of up to 11%.<br />
Canopies installed in the work place can<br />
improve the light reflection over a working<br />
space and provide better comfort for the<br />
end user.<br />
The TechZone Ceiling System combines<br />
high light reflectance ceilings with indirect<br />
lighting and can contribute to EA <strong>Credit</strong> 1.<br />
Appendix 1, <strong>Armstrong</strong> Products<br />
Environmental Performance Table<br />
includes the light reflectance of our<br />
ceiling tiles.<br />
www.armstrong-ceilings.co.uk<br />
www.armstrong-ceilings.ie<br />
recycleyourceilings@armstrong.com
MATERIAL AND RESOURCES<br />
MR <strong>Credit</strong> 2:<br />
CONSTRUCTION<br />
WASTE<br />
MANAGEMENT<br />
LEED NC, Schools,<br />
C & S, CI<br />
Divert 50% to 75%<br />
recycled<br />
Intent: To divert construction and<br />
demolition debris from disposal in landfills<br />
and incineration facilities. Redirect<br />
recyclable recovered resources back to<br />
the manufacturing process and reusable<br />
materials to appropriate sites.<br />
How <strong>Armstrong</strong> can help:<br />
<strong>Armstrong</strong> provide a comprehensive<br />
post-consumer mineral fibre ceiling tile<br />
take-back scheme in the UK and France.<br />
We offer a programme for refurbishment/<br />
strip out projects to recover ceiling tiles<br />
at the end of their life. And, we offer an<br />
Off-Cut recycling programme that diverts<br />
waste during the installation process from<br />
going to landfill.<br />
The ceiling tiles are 100% recycled into<br />
the mix and are processed into new<br />
ceiling tiles.<br />
Full details of the take back scheme<br />
are available at<br />
www.armstrong-ceilings.co.uk\environment<br />
recycleyourceilings@armstrong.com<br />
MATERIAL AND RESOURCES<br />
Intent: To increase demand for building<br />
products that incorporate recycled<br />
content materials, thereby reducing<br />
impacts resulting from extraction and<br />
processing of virgin materials.<br />
How <strong>Armstrong</strong> can help:<br />
A significant proportion of our ceiling<br />
tiles are produced using recycled raw<br />
materials, including slag mineral wool,<br />
other recycled mineral wools, recycled<br />
paper and recycled ceiling tiles. These<br />
recycled contents, typically between 30%<br />
and 60%, are indicated on all <strong>Armstrong</strong>’s<br />
published literature in accordance with<br />
EN ISO 14021: 2001.<br />
Appendix 1, <strong>Armstrong</strong> Products<br />
Environmental Performance Table<br />
includes the recycled content for our full<br />
product range.<br />
For specific post-consumer and preconsumer<br />
breakdowns please contact<br />
your <strong>Armstrong</strong> representative.<br />
MR <strong>Credit</strong> 4:<br />
RECYCLED CONTENT<br />
LEED NC, Schools, CS,<br />
CI<br />
The sum of post-consumer<br />
recycled content plus 1/2 of<br />
the pre-consumer content<br />
constitutes at least 10% or<br />
20%, based on cost, of the<br />
total value of the materials in<br />
the project<br />
INDOOR ENVIRONMENT QUALITY<br />
IEQ Prerequisite<br />
3: MINIMUM<br />
ACOUSTICAL<br />
PERFORMANCE<br />
LEED for Schools<br />
Intent: To provide classrooms that are<br />
quiet so that teachers can speak to the<br />
class without straining their voices and<br />
students can effectively communicate<br />
with each other and the teacher.<br />
How <strong>Armstrong</strong> can help:<br />
Detailed information on the acoustic<br />
performance of <strong>Armstrong</strong> ceiling tiles<br />
is available from Appendix 2, <strong>Armstrong</strong><br />
Products Absorption Attenuation<br />
Comparison Table.<br />
This information can be used by a suitably<br />
qualified acoustician to demonstrate how<br />
the ceiling tiles contribute to the acoustic<br />
perfomance of each space. Different<br />
ceiling tiles are available to contribute<br />
to all aspects of a building’s acoustic<br />
performance, from passive acoustic<br />
management of sound absoption and<br />
sound attenuation through to control of<br />
reverberation times and ambient noise<br />
levels.<br />
www.armstrong-ceilings.co.uk<br />
www.armstrong-ceilings.ie<br />
recycleyourceilings@armstrong.com
INDOOR ENVIRONMENT QUALITY<br />
IEQ 3.1 & 3.2:<br />
CONSTRUCTION<br />
INDOOR AIR<br />
QUALITY PLAN<br />
(During construction<br />
and before<br />
occupancy)<br />
LEED for Schools<br />
Intent: To reduce indoor air quality (IAQ)<br />
problems resulting from construction or<br />
renovation and promote the comfort and<br />
well-being of construction workers and<br />
building occupants.<br />
How <strong>Armstrong</strong> can help:<br />
All <strong>Armstrong</strong> ceiling tiles have low or<br />
zero VOC emission levels.<br />
Appendix 1, <strong>Armstrong</strong> Products<br />
Environmental Performance Table<br />
provides the results of the tests for each<br />
tile.<br />
INDOOR ENVIRONMENT QUALITY<br />
Intent: To reduce the quantity of indoor<br />
air contaminants that are odorous,<br />
irritating and/or harmful to the comfort and<br />
well-being of installers and occupants.<br />
How <strong>Armstrong</strong> can help:<br />
All <strong>Armstrong</strong> ceiling tiles have low or<br />
zero VOC emission levels and therefore<br />
can comply with an Indoor Air Quality<br />
Management Plan which commits to<br />
using low or zero VOC finishes.<br />
All <strong>Armstrong</strong> tiles have either been<br />
tested by a third party and comply with<br />
the requirements of EN 13964:2004<br />
unless they are exempt from testing<br />
(e.g metal or wooden ceiling tiles).<br />
<strong>Armstrong</strong> has achieved the M1<br />
classification under the Finnish Emission<br />
Classification of Building Materials<br />
scheme.<br />
Appendix 1, <strong>Armstrong</strong> Products<br />
Environmental Performance Table provides<br />
the results of the tests for each tile.<br />
IEQ <strong>Credit</strong> 4.6:<br />
LOW-EMITTING<br />
MATERIALS (Ceiling<br />
and wall systems)<br />
LEED for Schools<br />
INDOOR ENVIRONMENT QUALITY<br />
IEQ <strong>Credit</strong> 8.1, 8.2:<br />
DAYLIGHT AND<br />
VIEWS<br />
LEED NC, Schools,<br />
CS, CI<br />
Intent: To provide the building occupants<br />
with a connection between indoor spaces<br />
and the outdoors through the introduction<br />
of daylight and views into the regularly<br />
occupied areas of the building occupied<br />
areas of the building.<br />
How <strong>Armstrong</strong> can help:<br />
<strong>Armstrong</strong> high light reflectance ceilings<br />
can aid in extending daylighting into the<br />
space. A typical acoustical ceiling reflects<br />
just 75% of the light striking the surface,<br />
while a high light reflectance ceiling is<br />
engineered to reflect up to 90% of the<br />
light striking the surface.<br />
Recent independent studies have shown<br />
a 10 - 15% daylighting effectiveness<br />
increase.<br />
A separate study concluded that a high<br />
light reflectance ceilings could achieve<br />
the LEED credit with up to 12% less<br />
glazing than with a standard ceiling with a<br />
light reflection of 75%.<br />
Appendix 1, <strong>Armstrong</strong> Products<br />
Environmental Performance Table<br />
includes the light reflectance of our ceiling<br />
tiles.<br />
www.armstrong-ceilings.co.uk<br />
www.armstrong-ceilings.ie<br />
recycleyourceilings@armstrong.com
INDOOR ENVIRONMENT QUALITY<br />
IEQ 9: ENHANCED<br />
ACOUSTICAL<br />
PERFORMANCE<br />
LEED for Schools<br />
Intent: To provide classrooms that<br />
facilitates better teacher-to-student and<br />
student-to-student communications<br />
through effective acoustical design.<br />
How <strong>Armstrong</strong> can help:<br />
<strong>Armstrong</strong> can assist in the design of<br />
classrooms and other core learning<br />
spaces to include sufficient sound<br />
absorptive finishes for compliance with<br />
reverberation time requirements.<br />
Detailed information on the acoustic<br />
performance of <strong>Armstrong</strong> ceiling tiles<br />
is available from Appendix 2, <strong>Armstrong</strong><br />
Products Absorption and Attenuation<br />
Comparison Table.<br />
This information can be used by<br />
a suitably qualified acoustician to<br />
demonstrate how the ceilnig tiles<br />
contribute to the acoustic perfomance<br />
of each space. Different ceiling tiles are<br />
available to contribute to all aspects<br />
of a building’s acoustic performance,<br />
from passive acoustic management of<br />
sound absorption and sound attenuation<br />
through to control of reverberation times<br />
and ambient noise levels.<br />
Contact your local <strong>Armstrong</strong><br />
representative for details of solutions to<br />
achieve a balanced acoustical design.<br />
INNOVATION IN DESIGN<br />
Intent: To provide design teams and<br />
projects the opportunity to achieve<br />
exceptional performance above the<br />
requirements set by the LEED Green<br />
Building Rating System and/or innovative<br />
performance in Green Building categories<br />
not specifically addressed by the LEED<br />
Green Building Rating System..<br />
How <strong>Armstrong</strong> can help:<br />
LEED Innovation <strong>Credit</strong>s can be achieved<br />
when a project exceeds the criteria of the<br />
base requirements of the credit, or in the<br />
case of multi-tiered credits, the next tier.<br />
An Innovation <strong>Credit</strong> for Acoustics can<br />
be applied for demonstrating that the<br />
acoustical performance improvements<br />
of a building clearly enhance the indoor<br />
environment in ways consistent with<br />
the preservation of human health and<br />
maximisation of occupant productivity.<br />
Contact your local <strong>Armstrong</strong><br />
representative for details on solutions to<br />
achieve a balanced acoustical design.<br />
ID <strong>Credit</strong> 1:<br />
INNOVATION IN<br />
DESIGN<br />
LEED NC, Schools,<br />
CS, CI<br />
09/2012 - PX1215 - <strong>Armstrong</strong> Building Products - RCS Besançon B 784 131 575<br />
www.armstrong-ceilings.co.uk<br />
www.armstrong-ceilings.ie<br />
recycleyourceilings@armstrong.com
Appendix 1<br />
<strong>Armstrong</strong> Products Environmental Performance Table (August 2012)<br />
Product Recycled Content Light Reflectance<br />
Environmental Product<br />
Declaration<br />
VOC Emissions Ceiling Take Back Scheme<br />
Formaldehyde UK & France only<br />
BIOGUARD Acoustic 45% 88% E1 ✔<br />
BIOGUARD Plain 52% 90% E1 ✔<br />
CERAMAGUARD 38% 79% E1 n/a<br />
CIRRUS 33% 83% E1 ✔<br />
CIRRUS Design 33% 83% E1 ✔<br />
COLOURTONE DUNE 51% Up to 48% ✔ E1 ✔<br />
FINE FISSURED up to 51% 85% ✔ E1 ✔<br />
FINE FISSURED Black up to 51% 9% ✔ E1 ✔<br />
GRAPHIS 51% 92% E1 ✔<br />
CLEAN ROOM FL 35% 78% E1 n/a<br />
NEWTONE 1% 84% E1 ✔<br />
NEVADA 20% 82% E1 n/a<br />
OPTIMA 82% 87% E1 n/a<br />
PARAFON Hygien 20% 82% E1 n/a<br />
PERLA 33% 86% E1 ✔<br />
PERLA dB 65% 86% E1 ✔<br />
PERLA OP 0.95 53% 86% E1 ✔<br />
PERLA OP 1.00 36% 85% E1 ✔<br />
PLAIN 44% 87% E1 ✔<br />
DUNE MAX 45% 84% ✔ E1 ✔<br />
DUNE Vector 31% 85% E1 ✔<br />
DUNE dB 60% 84% E1 ✔<br />
DUNE SUPREME 42% 85% ✔ E1 ✔<br />
SIERRA OP 15% 83% E1 ✔<br />
ULTIMA 33% 87% ✔ E1 ✔<br />
ULTIMA dB 64% 87% E1 ✔<br />
ULTIMA OP 30% 87% E1 ✔<br />
ULTIMA Vector 33% 87% E1 ✔<br />
VISUAL 70% 71% E1 ✔<br />
TATRA up to 51% 80% ✔ E1 ✔<br />
CORTEGA up to 51% 80% ✔ E1 ✔<br />
ACADEMY MERIT 51% 85% ✔ E1 ✔<br />
ACADEMY DIPLOMA 51% 84% E1 ✔<br />
Grid 25% n/a ✔ E1 n/a<br />
Wood n/a 35-75% E1 n/a<br />
Metal 30% Up to 85% ✔ E1 n/a
09/2012 - PX1215 - <strong>Armstrong</strong> Building Products - RCS Besançon B 784 131 575<br />
Appendix 2<br />
<strong>Armstrong</strong> Products Absorption and Attenuation Comparison Table - (August 2012)<br />
Sound Absorption Sound Attenuation<br />
<strong>Armstrong</strong> Products aw Comparative Dnfw / Dncw <strong>Armstrong</strong> Products<br />
Ultima OP (1.00 + 0.95) + Optima (all thicknesses)<br />
Perla OP (1.00 + 0.95) + Nevada (all thicknesses)<br />
Metal Standard Perforated + OP19<br />
Metal Microperforated + OP19<br />
Parafon Hygien / Hydroboard<br />
Sierra OP<br />
1.00<br />
0.95<br />
0.90<br />
Class A<br />
Very High<br />
41-47 dB<br />
Metal Plain + B15 + Metal Plain (no infill)<br />
Ultima dB SL2 Planks<br />
Ultima tiles + glass fibre overlay to both sides*<br />
Metal Standard Perforated + B15<br />
Perla dB / Metal Microperforated + B15<br />
Wood Plain<br />
Metal Standard Perforated with pad (8mm)<br />
Metal Microperforated with pad (8mm)<br />
0.85<br />
0.80<br />
Class B<br />
High<br />
36-40 dB<br />
Metal Extra Microperforated + B15 / Dune dB / Ultima dB / Ceramaguard /<br />
Cirrus 75 / Ultima / Newtone / Bioguard Acoustic / Bioguard Plain /<br />
Clean Room FL / Graphis / Cirrus / Cirrus Image / Contrast Cirrus<br />
Wood Rg 3003<br />
Ultima / Perla / Dune Max<br />
Ultima dB / Perla dB / Dune dB<br />
Bioguard Acoustic / Cirrus 75<br />
Metal Standard Perforated + fleece or OP19 / B15<br />
Metal Microperforated + fleece or OP19 / B15<br />
Metal Extra Microperforated + OP19 / B15<br />
Fine Fissured / Academy Merit / Dune Vector<br />
Wood Rg 8013<br />
0.75<br />
0.70<br />
0.65<br />
0.60<br />
Class C<br />
High<br />
31-45 dB<br />
Perla / Dune Max<br />
Dune Supreme / Dune Supreme Unperforated<br />
Dune Plus / Colortone Dune<br />
Mezzanine DL 100<br />
Fine Fissured<br />
Academy Merit & Diploma<br />
Metal Ultra Microperforated /<br />
Metal Extra Microperforated + fleece<br />
Dune Supreme / Dune Planks<br />
Mezzanine DL 100 / Ceramaguard<br />
Cirrus / Cirrus Image<br />
Contrast Cirrus (Circles, Squares)<br />
Dune Plus / Colortone Dune<br />
Academy Diploma<br />
Wood Rg 3003 / Wood Rg 8002<br />
0.55<br />
0.50<br />
0.45<br />
0.40<br />
0.35<br />
0.30<br />
Class D<br />
Moderate<br />
26-30 dB<br />
Metal Standard Perforated + pad (16-40mm)<br />
Metal Microperforated + pad (16-40mm)<br />
Metal Extra Microperforated + fleece or pad (16-40mm)<br />
Sierra OP / Ultima OP<br />
Nevada Tegular (18mm)<br />
Wood Rg 8002<br />
Dune Supreme Unperforated<br />
Bioguard Plain<br />
Plain<br />
Graphis<br />
0.25<br />
0.20<br />
0.15<br />
Class E<br />
Low<br />
20-25 dB<br />
Perla OP<br />
Metal Standard Perforated + fleece or pad (8mm)<br />
Metal Microperforated + fleece or pad (8mm)<br />
Metal Extra Microperforated + pad (8mm)<br />
Nevada Board (18mm) / Optima (all thicknesses)<br />
Wood Rg 8013<br />
Metal Plain<br />
Clean Room FL<br />
Newtone<br />
Wood Plain<br />
0.10<br />
0.05<br />
0.00<br />
Very Low Below 20 dB None