14.04.2014 Views

LEED® Credit Summary - Armstrong

LEED® Credit Summary - Armstrong

LEED® Credit Summary - Armstrong

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CEILING&wall<br />

SYSTEMS<br />

CI/SfB<br />

(35) Xy<br />

08/2012<br />

Between us, ideas become reality ®<br />

<strong>Armstrong</strong> Ceiling Systems<br />

LEED <strong>Credit</strong> <strong>Summary</strong><br />

LEED, or Leadership in Energy and Environmental Design, is an internationallyrecognised<br />

green building certification system. Developed by the U.S Green<br />

Building Council, LEED provides building owners and operators with a framework<br />

for identifying and implementing practical and measurable green building design,<br />

construction, operations and maintenance solutions.<br />

LEED promotes sustainable building and development practices through a suite<br />

of rating systems that recognise projects that implement strategies for better<br />

environmental and health performance.<br />

LEED uses a straightforward scoring system (credits) which are supported by<br />

evidence-based science and research.<br />

The following LEED credit summary has been developed by <strong>Armstrong</strong> Ceiling<br />

Systems to support the design, specification and installation of <strong>Armstrong</strong><br />

suspended ceiling systems in a wide range of buildings.<br />

Supporting evidence is contained in Appendix 1, <strong>Armstrong</strong> Products –<br />

Environmental Performance Table and Appendix 2, <strong>Armstrong</strong> Products –<br />

Absorption Attenuation Comparison Table. These appendices cover the full range<br />

of <strong>Armstrong</strong> suspended ceiling systems.<br />

*Key:<br />

NC = New Construction and Major Renovations<br />

CS = Core & Shell Developments<br />

CI = Commercial Interiors<br />

ENERGY AND ATMOSPHERE<br />

EA <strong>Credit</strong> 1:<br />

OPTIMISE ENERGY<br />

PERFORMANCE<br />

LEED NC, Schools,<br />

CS, CI<br />

*Energy and Environmental<br />

Effects of High Light<br />

Reflectance Ceilings: Brinjac<br />

Engineering 2006<br />

Intent: Achieve increasing levels of<br />

energy performance above the baseline<br />

standard to reduce environmental and<br />

economic impacts associated with<br />

excessive energy use.<br />

How <strong>Armstrong</strong> can help:<br />

<strong>Armstrong</strong> range of mineral fibre and<br />

metal ceiling tiles achieve high levels of<br />

light reflectance. High light reflectance<br />

ceilings enhance indirect lighting by<br />

improving overall lighting uniformity<br />

returning up to 90% of the light back<br />

into the space, compared with 75% with<br />

standard ceilings*. A light reflectance of<br />

90% and more allows 20% cost savings<br />

with indirect lighting, and can yield total<br />

building energy savings of up to 11%.<br />

Canopies installed in the work place can<br />

improve the light reflection over a working<br />

space and provide better comfort for the<br />

end user.<br />

The TechZone Ceiling System combines<br />

high light reflectance ceilings with indirect<br />

lighting and can contribute to EA <strong>Credit</strong> 1.<br />

Appendix 1, <strong>Armstrong</strong> Products<br />

Environmental Performance Table<br />

includes the light reflectance of our<br />

ceiling tiles.<br />

www.armstrong-ceilings.co.uk<br />

www.armstrong-ceilings.ie<br />

recycleyourceilings@armstrong.com


MATERIAL AND RESOURCES<br />

MR <strong>Credit</strong> 2:<br />

CONSTRUCTION<br />

WASTE<br />

MANAGEMENT<br />

LEED NC, Schools,<br />

C & S, CI<br />

Divert 50% to 75%<br />

recycled<br />

Intent: To divert construction and<br />

demolition debris from disposal in landfills<br />

and incineration facilities. Redirect<br />

recyclable recovered resources back to<br />

the manufacturing process and reusable<br />

materials to appropriate sites.<br />

How <strong>Armstrong</strong> can help:<br />

<strong>Armstrong</strong> provide a comprehensive<br />

post-consumer mineral fibre ceiling tile<br />

take-back scheme in the UK and France.<br />

We offer a programme for refurbishment/<br />

strip out projects to recover ceiling tiles<br />

at the end of their life. And, we offer an<br />

Off-Cut recycling programme that diverts<br />

waste during the installation process from<br />

going to landfill.<br />

The ceiling tiles are 100% recycled into<br />

the mix and are processed into new<br />

ceiling tiles.<br />

Full details of the take back scheme<br />

are available at<br />

www.armstrong-ceilings.co.uk\environment<br />

recycleyourceilings@armstrong.com<br />

MATERIAL AND RESOURCES<br />

Intent: To increase demand for building<br />

products that incorporate recycled<br />

content materials, thereby reducing<br />

impacts resulting from extraction and<br />

processing of virgin materials.<br />

How <strong>Armstrong</strong> can help:<br />

A significant proportion of our ceiling<br />

tiles are produced using recycled raw<br />

materials, including slag mineral wool,<br />

other recycled mineral wools, recycled<br />

paper and recycled ceiling tiles. These<br />

recycled contents, typically between 30%<br />

and 60%, are indicated on all <strong>Armstrong</strong>’s<br />

published literature in accordance with<br />

EN ISO 14021: 2001.<br />

Appendix 1, <strong>Armstrong</strong> Products<br />

Environmental Performance Table<br />

includes the recycled content for our full<br />

product range.<br />

For specific post-consumer and preconsumer<br />

breakdowns please contact<br />

your <strong>Armstrong</strong> representative.<br />

MR <strong>Credit</strong> 4:<br />

RECYCLED CONTENT<br />

LEED NC, Schools, CS,<br />

CI<br />

The sum of post-consumer<br />

recycled content plus 1/2 of<br />

the pre-consumer content<br />

constitutes at least 10% or<br />

20%, based on cost, of the<br />

total value of the materials in<br />

the project<br />

INDOOR ENVIRONMENT QUALITY<br />

IEQ Prerequisite<br />

3: MINIMUM<br />

ACOUSTICAL<br />

PERFORMANCE<br />

LEED for Schools<br />

Intent: To provide classrooms that are<br />

quiet so that teachers can speak to the<br />

class without straining their voices and<br />

students can effectively communicate<br />

with each other and the teacher.<br />

How <strong>Armstrong</strong> can help:<br />

Detailed information on the acoustic<br />

performance of <strong>Armstrong</strong> ceiling tiles<br />

is available from Appendix 2, <strong>Armstrong</strong><br />

Products Absorption Attenuation<br />

Comparison Table.<br />

This information can be used by a suitably<br />

qualified acoustician to demonstrate how<br />

the ceiling tiles contribute to the acoustic<br />

perfomance of each space. Different<br />

ceiling tiles are available to contribute<br />

to all aspects of a building’s acoustic<br />

performance, from passive acoustic<br />

management of sound absoption and<br />

sound attenuation through to control of<br />

reverberation times and ambient noise<br />

levels.<br />

www.armstrong-ceilings.co.uk<br />

www.armstrong-ceilings.ie<br />

recycleyourceilings@armstrong.com


INDOOR ENVIRONMENT QUALITY<br />

IEQ 3.1 & 3.2:<br />

CONSTRUCTION<br />

INDOOR AIR<br />

QUALITY PLAN<br />

(During construction<br />

and before<br />

occupancy)<br />

LEED for Schools<br />

Intent: To reduce indoor air quality (IAQ)<br />

problems resulting from construction or<br />

renovation and promote the comfort and<br />

well-being of construction workers and<br />

building occupants.<br />

How <strong>Armstrong</strong> can help:<br />

All <strong>Armstrong</strong> ceiling tiles have low or<br />

zero VOC emission levels.<br />

Appendix 1, <strong>Armstrong</strong> Products<br />

Environmental Performance Table<br />

provides the results of the tests for each<br />

tile.<br />

INDOOR ENVIRONMENT QUALITY<br />

Intent: To reduce the quantity of indoor<br />

air contaminants that are odorous,<br />

irritating and/or harmful to the comfort and<br />

well-being of installers and occupants.<br />

How <strong>Armstrong</strong> can help:<br />

All <strong>Armstrong</strong> ceiling tiles have low or<br />

zero VOC emission levels and therefore<br />

can comply with an Indoor Air Quality<br />

Management Plan which commits to<br />

using low or zero VOC finishes.<br />

All <strong>Armstrong</strong> tiles have either been<br />

tested by a third party and comply with<br />

the requirements of EN 13964:2004<br />

unless they are exempt from testing<br />

(e.g metal or wooden ceiling tiles).<br />

<strong>Armstrong</strong> has achieved the M1<br />

classification under the Finnish Emission<br />

Classification of Building Materials<br />

scheme.<br />

Appendix 1, <strong>Armstrong</strong> Products<br />

Environmental Performance Table provides<br />

the results of the tests for each tile.<br />

IEQ <strong>Credit</strong> 4.6:<br />

LOW-EMITTING<br />

MATERIALS (Ceiling<br />

and wall systems)<br />

LEED for Schools<br />

INDOOR ENVIRONMENT QUALITY<br />

IEQ <strong>Credit</strong> 8.1, 8.2:<br />

DAYLIGHT AND<br />

VIEWS<br />

LEED NC, Schools,<br />

CS, CI<br />

Intent: To provide the building occupants<br />

with a connection between indoor spaces<br />

and the outdoors through the introduction<br />

of daylight and views into the regularly<br />

occupied areas of the building occupied<br />

areas of the building.<br />

How <strong>Armstrong</strong> can help:<br />

<strong>Armstrong</strong> high light reflectance ceilings<br />

can aid in extending daylighting into the<br />

space. A typical acoustical ceiling reflects<br />

just 75% of the light striking the surface,<br />

while a high light reflectance ceiling is<br />

engineered to reflect up to 90% of the<br />

light striking the surface.<br />

Recent independent studies have shown<br />

a 10 - 15% daylighting effectiveness<br />

increase.<br />

A separate study concluded that a high<br />

light reflectance ceilings could achieve<br />

the LEED credit with up to 12% less<br />

glazing than with a standard ceiling with a<br />

light reflection of 75%.<br />

Appendix 1, <strong>Armstrong</strong> Products<br />

Environmental Performance Table<br />

includes the light reflectance of our ceiling<br />

tiles.<br />

www.armstrong-ceilings.co.uk<br />

www.armstrong-ceilings.ie<br />

recycleyourceilings@armstrong.com


INDOOR ENVIRONMENT QUALITY<br />

IEQ 9: ENHANCED<br />

ACOUSTICAL<br />

PERFORMANCE<br />

LEED for Schools<br />

Intent: To provide classrooms that<br />

facilitates better teacher-to-student and<br />

student-to-student communications<br />

through effective acoustical design.<br />

How <strong>Armstrong</strong> can help:<br />

<strong>Armstrong</strong> can assist in the design of<br />

classrooms and other core learning<br />

spaces to include sufficient sound<br />

absorptive finishes for compliance with<br />

reverberation time requirements.<br />

Detailed information on the acoustic<br />

performance of <strong>Armstrong</strong> ceiling tiles<br />

is available from Appendix 2, <strong>Armstrong</strong><br />

Products Absorption and Attenuation<br />

Comparison Table.<br />

This information can be used by<br />

a suitably qualified acoustician to<br />

demonstrate how the ceilnig tiles<br />

contribute to the acoustic perfomance<br />

of each space. Different ceiling tiles are<br />

available to contribute to all aspects<br />

of a building’s acoustic performance,<br />

from passive acoustic management of<br />

sound absorption and sound attenuation<br />

through to control of reverberation times<br />

and ambient noise levels.<br />

Contact your local <strong>Armstrong</strong><br />

representative for details of solutions to<br />

achieve a balanced acoustical design.<br />

INNOVATION IN DESIGN<br />

Intent: To provide design teams and<br />

projects the opportunity to achieve<br />

exceptional performance above the<br />

requirements set by the LEED Green<br />

Building Rating System and/or innovative<br />

performance in Green Building categories<br />

not specifically addressed by the LEED<br />

Green Building Rating System..<br />

How <strong>Armstrong</strong> can help:<br />

LEED Innovation <strong>Credit</strong>s can be achieved<br />

when a project exceeds the criteria of the<br />

base requirements of the credit, or in the<br />

case of multi-tiered credits, the next tier.<br />

An Innovation <strong>Credit</strong> for Acoustics can<br />

be applied for demonstrating that the<br />

acoustical performance improvements<br />

of a building clearly enhance the indoor<br />

environment in ways consistent with<br />

the preservation of human health and<br />

maximisation of occupant productivity.<br />

Contact your local <strong>Armstrong</strong><br />

representative for details on solutions to<br />

achieve a balanced acoustical design.<br />

ID <strong>Credit</strong> 1:<br />

INNOVATION IN<br />

DESIGN<br />

LEED NC, Schools,<br />

CS, CI<br />

09/2012 - PX1215 - <strong>Armstrong</strong> Building Products - RCS Besançon B 784 131 575<br />

www.armstrong-ceilings.co.uk<br />

www.armstrong-ceilings.ie<br />

recycleyourceilings@armstrong.com


Appendix 1<br />

<strong>Armstrong</strong> Products Environmental Performance Table (August 2012)<br />

Product Recycled Content Light Reflectance<br />

Environmental Product<br />

Declaration<br />

VOC Emissions Ceiling Take Back Scheme<br />

Formaldehyde UK & France only<br />

BIOGUARD Acoustic 45% 88% E1 ✔<br />

BIOGUARD Plain 52% 90% E1 ✔<br />

CERAMAGUARD 38% 79% E1 n/a<br />

CIRRUS 33% 83% E1 ✔<br />

CIRRUS Design 33% 83% E1 ✔<br />

COLOURTONE DUNE 51% Up to 48% ✔ E1 ✔<br />

FINE FISSURED up to 51% 85% ✔ E1 ✔<br />

FINE FISSURED Black up to 51% 9% ✔ E1 ✔<br />

GRAPHIS 51% 92% E1 ✔<br />

CLEAN ROOM FL 35% 78% E1 n/a<br />

NEWTONE 1% 84% E1 ✔<br />

NEVADA 20% 82% E1 n/a<br />

OPTIMA 82% 87% E1 n/a<br />

PARAFON Hygien 20% 82% E1 n/a<br />

PERLA 33% 86% E1 ✔<br />

PERLA dB 65% 86% E1 ✔<br />

PERLA OP 0.95 53% 86% E1 ✔<br />

PERLA OP 1.00 36% 85% E1 ✔<br />

PLAIN 44% 87% E1 ✔<br />

DUNE MAX 45% 84% ✔ E1 ✔<br />

DUNE Vector 31% 85% E1 ✔<br />

DUNE dB 60% 84% E1 ✔<br />

DUNE SUPREME 42% 85% ✔ E1 ✔<br />

SIERRA OP 15% 83% E1 ✔<br />

ULTIMA 33% 87% ✔ E1 ✔<br />

ULTIMA dB 64% 87% E1 ✔<br />

ULTIMA OP 30% 87% E1 ✔<br />

ULTIMA Vector 33% 87% E1 ✔<br />

VISUAL 70% 71% E1 ✔<br />

TATRA up to 51% 80% ✔ E1 ✔<br />

CORTEGA up to 51% 80% ✔ E1 ✔<br />

ACADEMY MERIT 51% 85% ✔ E1 ✔<br />

ACADEMY DIPLOMA 51% 84% E1 ✔<br />

Grid 25% n/a ✔ E1 n/a<br />

Wood n/a 35-75% E1 n/a<br />

Metal 30% Up to 85% ✔ E1 n/a


09/2012 - PX1215 - <strong>Armstrong</strong> Building Products - RCS Besançon B 784 131 575<br />

Appendix 2<br />

<strong>Armstrong</strong> Products Absorption and Attenuation Comparison Table - (August 2012)<br />

Sound Absorption Sound Attenuation<br />

<strong>Armstrong</strong> Products aw Comparative Dnfw / Dncw <strong>Armstrong</strong> Products<br />

Ultima OP (1.00 + 0.95) + Optima (all thicknesses)<br />

Perla OP (1.00 + 0.95) + Nevada (all thicknesses)<br />

Metal Standard Perforated + OP19<br />

Metal Microperforated + OP19<br />

Parafon Hygien / Hydroboard<br />

Sierra OP<br />

1.00<br />

0.95<br />

0.90<br />

Class A<br />

Very High<br />

41-47 dB<br />

Metal Plain + B15 + Metal Plain (no infill)<br />

Ultima dB SL2 Planks<br />

Ultima tiles + glass fibre overlay to both sides*<br />

Metal Standard Perforated + B15<br />

Perla dB / Metal Microperforated + B15<br />

Wood Plain<br />

Metal Standard Perforated with pad (8mm)<br />

Metal Microperforated with pad (8mm)<br />

0.85<br />

0.80<br />

Class B<br />

High<br />

36-40 dB<br />

Metal Extra Microperforated + B15 / Dune dB / Ultima dB / Ceramaguard /<br />

Cirrus 75 / Ultima / Newtone / Bioguard Acoustic / Bioguard Plain /<br />

Clean Room FL / Graphis / Cirrus / Cirrus Image / Contrast Cirrus<br />

Wood Rg 3003<br />

Ultima / Perla / Dune Max<br />

Ultima dB / Perla dB / Dune dB<br />

Bioguard Acoustic / Cirrus 75<br />

Metal Standard Perforated + fleece or OP19 / B15<br />

Metal Microperforated + fleece or OP19 / B15<br />

Metal Extra Microperforated + OP19 / B15<br />

Fine Fissured / Academy Merit / Dune Vector<br />

Wood Rg 8013<br />

0.75<br />

0.70<br />

0.65<br />

0.60<br />

Class C<br />

High<br />

31-45 dB<br />

Perla / Dune Max<br />

Dune Supreme / Dune Supreme Unperforated<br />

Dune Plus / Colortone Dune<br />

Mezzanine DL 100<br />

Fine Fissured<br />

Academy Merit & Diploma<br />

Metal Ultra Microperforated /<br />

Metal Extra Microperforated + fleece<br />

Dune Supreme / Dune Planks<br />

Mezzanine DL 100 / Ceramaguard<br />

Cirrus / Cirrus Image<br />

Contrast Cirrus (Circles, Squares)<br />

Dune Plus / Colortone Dune<br />

Academy Diploma<br />

Wood Rg 3003 / Wood Rg 8002<br />

0.55<br />

0.50<br />

0.45<br />

0.40<br />

0.35<br />

0.30<br />

Class D<br />

Moderate<br />

26-30 dB<br />

Metal Standard Perforated + pad (16-40mm)<br />

Metal Microperforated + pad (16-40mm)<br />

Metal Extra Microperforated + fleece or pad (16-40mm)<br />

Sierra OP / Ultima OP<br />

Nevada Tegular (18mm)<br />

Wood Rg 8002<br />

Dune Supreme Unperforated<br />

Bioguard Plain<br />

Plain<br />

Graphis<br />

0.25<br />

0.20<br />

0.15<br />

Class E<br />

Low<br />

20-25 dB<br />

Perla OP<br />

Metal Standard Perforated + fleece or pad (8mm)<br />

Metal Microperforated + fleece or pad (8mm)<br />

Metal Extra Microperforated + pad (8mm)<br />

Nevada Board (18mm) / Optima (all thicknesses)<br />

Wood Rg 8013<br />

Metal Plain<br />

Clean Room FL<br />

Newtone<br />

Wood Plain<br />

0.10<br />

0.05<br />

0.00<br />

Very Low Below 20 dB None

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!