AC axial<br />

K series<br />

AC axial<br />

A series<br />

EC axial<br />

S series<br />

Technology<br />

Q-motor<br />

Accessories<br />

EC axial <strong>fans</strong><br />

AC axial<br />

S series<br />

AC axial <strong>fans</strong><br />

General<br />

information<br />

PE1<br />

+18<br />

V<br />

+10 0-10<br />

GND<br />

GND NC COM<br />

1 V V<br />

H+ H+ TW<br />

Sensor<br />

KL2B<br />

KL3B<br />

KL5B<br />

PE2<br />

+ -<br />

KL1<br />

ESM<br />

EC-SYSTEMS<br />

RS<br />

A<br />

RS<br />

B<br />

RS<br />

A<br />

KL2A<br />

RS<br />

B<br />

An<br />

Tacho<br />

GND NO COM EN EṈ<br />

+<br />

KL3A KL4<br />

H1 H2 H3<br />

PTC H- H- U V W<br />

KL5A<br />

KL6<br />

Connector Connection Assignment / function Connector Connection Assignment / function<br />

PE1<br />

Ground connection<br />

KL3A NO<br />

Relay contact for alarm, make for failure<br />

PE2<br />

Ground connection<br />

COM Relay contact for alarm<br />

KL1 + 110 VDC<br />

KL3B NC<br />

Relay contact for alarm, break for failure<br />

-<br />

110 VDC<br />

COM Relay contact for alarm<br />

KL2A RS A Interface connection RS A<br />

KL4 EN + Enable input via RESET function<br />

RS B Interface connection RS B<br />

EN - Enable input via RESET function<br />

RS A Interface connection RS A<br />

KL5A H1 Hall-sensor 1<br />

RS B Interface connection RS B H2 Hall-sensor 2<br />

An, Tacho Tach output, open collector H3 Hall-sensor 3<br />

GND Reference KL2 (for KL2 only) Shielding connection<br />

KL2B +18 V +18 V (non-stabilised, +20%, 20 mA) for supplying<br />

Shielding connection<br />

external sensors<br />

KL5B H+ Power supply for hall-sensors (+)<br />

Sensor 1 Input for external sensor, Ri = 100 k H+ Power supply for hall-sensors (+)<br />

GND Reference KL2 (for KL2 only) TW / PTC Thermal switch or PTC connection<br />

+10 V +10 V (stabilised +/- 3 %, 25 mA) H- Power supply for hall-sensors (-)<br />

0-10 V Input for set value 0 - 10 V, Ri = 100 k H- Power supply for hall-sensors (-)<br />

GND Reference KL2 (for KL2 only) KL6 U Motor winding U<br />

V<br />

Motor winding V<br />

W<br />

Motor winding W<br />

339<br />