19.04.2014 Views

Axial fans

Axial fans

Axial fans

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RS A<br />

RS B<br />

RS A<br />

RS B<br />

GND<br />

0-10 V<br />

PWM<br />

4-20 mA<br />

ESM<br />

AC axial<br />

A series<br />

EC axial <strong>fans</strong><br />

AC axial<br />

K series<br />

AC axial<br />

S series<br />

AC axial <strong>fans</strong><br />

General<br />

information<br />

L1) EC motors (size 112, single-phase mains-powered)<br />

KL3 KL2 KL1<br />

+20 V<br />

+10 V<br />

0-10 V<br />

PWM<br />

GND<br />

OUT<br />

NO<br />

COM<br />

NC<br />

L<br />

N<br />

PE<br />

Connector Connection Assignment / function Connector Connection Assignment / function<br />

PE<br />

PE Protective earth KL3 OUT<br />

KL1 N Mains 50/60 Hz, neutral<br />

KL2<br />

L<br />

NC<br />

COM<br />

NO<br />

Mains 50/60 Hz, phase<br />

Alarm relay, break for failure<br />

Alarm relay, COMMON (2A, 250 VAC, AC1)<br />

Alarm relay, make for failure<br />

GND GND<br />

0-10 V / PWM Control / Actual value input (Impedance 100 k)<br />

+10 V<br />

+20 V<br />

4-20 mA Control / Actual value input<br />

0-10 V / PWM Control / Actual value input<br />

GND<br />

RSB<br />

RSA<br />

RSB<br />

RSA<br />

Master output 0-10 V max. 3 mA<br />

Supply for external potentiometer,<br />

10 VDC (+10 %) @ 10 mA<br />

Supply for external sensor,<br />

20 VDC (±20 %) @ 50 mA<br />

GND<br />

RS485 interface for ebmBUS; RS B<br />

RS485 interface for ebmBUS; RS A<br />

RS485 interface for ebmBUS; RS B<br />

RS485 interface for ebmBUS; RS A<br />

EC axial<br />

S series<br />

Q-motor<br />

L2) EC motors (size 112, three-phase mains-powered)<br />

KL3 KL2 KL1<br />

RS A<br />

RS B<br />

RS A<br />

RS B<br />

GND<br />

0-10 V<br />

PWM<br />

4-20 mA<br />

+20 V<br />

+10 V<br />

0-10 V<br />

PWM<br />

GND<br />

OUT<br />

NO<br />

COM<br />

NC<br />

L1<br />

L2<br />

L3<br />

PE<br />

Connector Connection Assignment / function Connector Connection Assignment / function<br />

PE<br />

PE Protective earth KL3 OUT<br />

KL1 L3 Mains; L3<br />

KL2<br />

L2<br />

L1<br />

NC<br />

COM<br />

NO<br />

Mains; L2<br />

Mains; L1<br />

Alarm relay, break for failure<br />

Alarm relay, COMMON (2A, 250 VAC, AC1)<br />

Alarm relay, make for failure<br />

GND GND<br />

0-10 V / PWM Control / Actual value input (Impedance 100 k)<br />

+10 V<br />

+20 V<br />

4-20 mA Control / Actual value input<br />

0-10 V / PWM Control / Actual value input<br />

GND<br />

RSB<br />

RSA<br />

RSB<br />

RSA<br />

Master output 0-10 V max. 3 mA<br />

Supply for external potentiometer,<br />

10 VDC (+10 %) @ 10 mA<br />

Supply for external sensor,<br />

20 VDC (±20 %) @ 50 mA<br />

GND<br />

EC-SYSTEMS<br />

Accessories<br />

Technology<br />

RS485 interface for ebmBUS; RS B<br />

RS485 interface for ebmBUS; RS A<br />

RS485 interface for ebmBUS; RS B<br />

RS485 interface for ebmBUS; RS A<br />

427<br />

Contacts

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!