<strong>Corning</strong> ® <strong>HYPERStack</strong> Cell Culture Vessel<br />
Closed System Protocol Guide<br />
<strong>HYPERStack</strong> Vessel Set-Up<br />
G<br />
H<br />
J<br />
B<br />
F<br />
E<br />
D<br />
C<br />
B<br />
A<br />
A <strong>HYPERStack</strong> Vessel manifolds<br />
B Liquid handling tubing<br />
C Liquid handling tubing clamp<br />
D Y connector with sampling port<br />
E Chase tube clamp<br />
F Chase tubing<br />
G 0.2 µm chase tube filter<br />
H 0.2 µm air filter<br />
J Female MPC with plug<br />
A<br />
<strong>Corning</strong> <strong>HYPERStack</strong> vessels can be connected to tubing via tube welding<br />
or by using the pre-assembled, multi-purpose connects (MPCs).<br />
Seeding the <strong>HYPERStack</strong> Vessel<br />
1 2 3<br />
Tube weld serum and media bags, mix thoroughly.<br />
1: Clamp off ~300 mL of media in the top of the bag. Fill syringe with cell inoculum.<br />
Inject into bottom portion of media bag.<br />
Attach inoculated media bag to <strong>HYPERStack</strong> vessel’s 3/8" I.D. liquid handling tubing.<br />
2: Close liquid handling tubing clamp.<br />
3: Close chase tubing clamp.
Filling the <strong>HYPERStack</strong> Vessel<br />
1 2 3 4 5<br />
1: Place <strong>HYPERStack</strong> vessel into fill position at a 10° angle and position media bag at<br />
same level as the <strong>HYPERStack</strong> vessel.<br />
2: Open liquid handling tubing clamp.<br />
3: Open media bag tubing clamp. Fluid will enter the <strong>HYPERStack</strong> vessel.<br />
4: Raise media bag to increase flow into the <strong>HYPERStack</strong> vessel, emptying the inoculated<br />
portion of the media bag.<br />
5: Remove clamp on top of media bag; finish filling <strong>HYPERStack</strong> vessel to the fill line.<br />
To reduce rate of flow and prevent overfilling, lower media bag during final fill.<br />
Isolate Liquid into <strong>HYPERStack</strong> Layers<br />
1 2 3<br />
4<br />
✕<br />
5 6 7<br />
1: Place <strong>HYPERStack</strong> vessel into “isolation” position and lower media bag below<br />
the height of the <strong>HYPERStack</strong> vessel.<br />
2: Hold the chase filter upright and open the chase tube clamp. Allow excess media<br />
to empty back into the media bag.<br />
3: Close the media bag tubing clamp.<br />
4: Open the liquid handling tubing clamp.<br />
5: Return <strong>HYPERStack</strong> vessel to starting position.<br />
6: Close chase tube clamp.<br />
7: Close liquid handling tube clamp.<br />
Place <strong>HYPERStack</strong> vessel into incubator. (Option: Empty media bag can be<br />
removed or remain attached to the <strong>HYPERStack</strong> vessel.)<br />
Keep the vent filter upright to prevent wetting out the filter.
Empty Spent Media from <strong>HYPERStack</strong> Vessel<br />
1 2 3 4<br />
5 6 7 8<br />
1: Remove <strong>HYPERStack</strong> vessel from incubator; keep vent tubing upright.<br />
2: Place <strong>HYPERStack</strong> vessel in “fill” position at a 10° angle.<br />
Lower media bag below height of <strong>HYPERStack</strong> vessel.<br />
3: Open the media bag tubing clamp.<br />
4: Open the vessel’s liquid handling tubing clamp. Fluid will enter empty media bag.<br />
5: Place <strong>HYPERStack</strong> vessel in final empty position and let all media drain.<br />
6: Lift tubing to chase remaining fluid into the media bag.<br />
7: Close liquid handling tubing clamp.<br />
8: Close media bag tubing clamp. Remove spent media bag.<br />
Keep the vent filter upright to prevent wetting out the filter.<br />
<strong>Corning</strong> <strong>HYPERStack</strong> Cell Culture<br />
Vessel Product Information<br />
◗ Growth area per layer. . . . . 500 cm 2<br />
◗ Media per layer. . . . . . . . . . . . 100 mL<br />
◗ Media per cm 2 . . . . . . . . . . . . . 0.2 mL<br />
◗ Stackette internal height . . 2.0 mm<br />
◗ Triple bagged<br />
◗ <strong>Corning</strong> CellBIND® Surface treated<br />
◗ Sterile<br />
3 Sizes Available:<br />
HyperStack-12 Layer . . . 6,000 cm 2<br />
HyperStack-36 Layer. . 18,000 cm 2<br />
HyperStack-120 Layer 60,000 cm 2<br />
Suggested Reagent Volumes:<br />
Cell dissociation solution:<br />
HyperStack-12 Layer . . 200 mL<br />
HyperStack-36 Layer . . . 600 mL<br />
Complete media:<br />
HyperStack-12 Layer. . . . . . 1.3 L<br />
HyperStack-36 Layer. . . . . . 3.9 L<br />
Cell Harvest from <strong>HYPERStack</strong> Vessel<br />
1 2 3 4 5 6<br />
1: Connect cell dissociation and quench bags together to form harvest bag assembly.<br />
2: Attach to <strong>HYPERStack</strong> vessel.<br />
3: Raise harvest bag assembly above height of <strong>HYPERStack</strong> vessel and place it into<br />
“fill” position at a 10° angle.<br />
4: Open cell dissociation solution tube clamp.<br />
5: Open harvest bag assembly tube clamp. Fluid will enter the <strong>HYPERStack</strong> vessel.<br />
6: Close liquid handling tube clamp.<br />
(continued on back)
Cell Harvest from <strong>HYPERStack</strong> Vessel (continued)<br />
1 2 3 4 5 6<br />
1: Close cell dissociation tube clamp.<br />
2: Return <strong>HYPERStack</strong> vessel to the starting position; rock the vessel to distribute cell<br />
dissociation solution.<br />
3: After incubating the <strong>HYPERStack</strong> vessel for the required time for cell release, place<br />
<strong>HYPERStack</strong> vessel in “fill” position at a 10° angle.<br />
4: Open quench bag tube clamp.<br />
5: Open liquid handling tube clamp. Quench solution will enter the <strong>HYPERStack</strong> vessel.<br />
6: Close liquid handling tube clamp. Distribute the quench solution to completely<br />
deactivate the cell dissociation solution.<br />
1 2 3 4 5<br />
1: Place harvest bag assembly lower than <strong>HYPERStack</strong> vessel.<br />
2: Place the vessel in the empty position.<br />
3: Open liquid handling tube clamp.<br />
4: Transfer cell solution into empty quench bag.<br />
5: Disconnect harvest bag assembly from <strong>HYPERStack</strong> vessel. Cell suspension is<br />
ready for processing.<br />
Ordering Information<br />
For replacement filters, contact Sartorius Stedim North America Inc.<br />
Tel.: +1.631.254.4249 or E-mail: techsupport@sartorius-stedim.com.<br />
Cat. No. Description Qty/Pack<br />
17805----------BVN Nonsterile, Midisart BV, individually packed 100<br />
17805----------BVQ Nonsterile, Midisart BV, individually packed 500<br />
17805----------E (NPE) Sterile, Midisart 2000, individually packed 12<br />
17805----------G (NPG) Sterile, Midisart 2000, individually packed 25<br />
For additional product or technical information, please visit<br />
www.corning.com/lifesciences or call 1.800.492.1110.<br />
Outside the United States, please call 1.978.442.2200.<br />
<strong>Corning</strong> is a registered trademark of <strong>Corning</strong> <strong>Incorporated</strong>, <strong>Corning</strong>, NY.<br />
<strong>HYPERStack</strong> is a trademark of <strong>Corning</strong> <strong>Incorporated</strong>, <strong>Corning</strong>, NY.<br />
<strong>Corning</strong> <strong>Incorporated</strong>, One Riverfront Plaza, <strong>Corning</strong>, NY 14831-0001<br />
<strong>Corning</strong> <strong>Incorporated</strong><br />
Life Sciences<br />
Tower 2, 4th Floor<br />
900 Chelmsford St.<br />
Lowell, MA 01851<br />
t 800.492.1110<br />
t 978.442.2200<br />
f 978.442.2476<br />
www.corning.com/lifesciences<br />
© 2011 <strong>Corning</strong> <strong>Incorporated</strong> Printed in U.S.A. 4/11 POD CLS-AN-171 REV3