50 mL Retort Kit - OFI Testing Equipment, Inc.
50 mL Retort Kit - OFI Testing Equipment, Inc.
50 mL Retort Kit - OFI Testing Equipment, Inc.
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Concentrations of low gravity solids, weighting material and suspended<br />
solids may be calculated as:<br />
C lg = 3.49 (P lg ) x (V lg )<br />
C b = 3.49 (P b ) x (V b )<br />
C SS = C lg + C b<br />
Where:<br />
C lg = Low gravity concentration, pounds per barrel<br />
C b = Weighting material concentration, pounds per barrel<br />
C SS = Suspended solids concentration, pounds per barrel<br />
<strong>OFI</strong>TE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 11