MATERIAL SAFETY DATA SHEET - Cardinal Health DFU/MSDS
MATERIAL SAFETY DATA SHEET - Cardinal Health DFU/MSDS
MATERIAL SAFETY DATA SHEET - Cardinal Health DFU/MSDS
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>MATERIAL</strong> <strong>SAFETY</strong> <strong>DATA</strong> <strong>SHEET</strong><br />
Manufactured for: Manufactured by: Telephone:<br />
Sage Products Inc. Approved mixing vendors Product Info 815 455 4700<br />
3909 Three Oaks Road Tech Info 815 455 4700<br />
Cary, IL 60013 Emergency 800 424 9300<br />
1 PRODUCT IDENTIFICATION<br />
Product Name:<br />
Comfort Bath Solution - Fragrance Free<br />
Product Number(s): 7411-X, 7770, 7803, 7803-X, 7811*, 7812*, 7856, 7903, 7907, 7956,<br />
7959, 7980*, 7980L*, 7981*, 7983*, 7985*, 7987, 7988, 7989<br />
Sage Item Number:<br />
Chemical Family:<br />
Formula:<br />
R98163C<br />
Aqueous mixture.<br />
Proprietary.<br />
DOT Hazard:<br />
Not listed.<br />
* = Obsolete<br />
Chemical Hazard Rating: <strong>Health</strong> 0<br />
Flammability 0<br />
Reactivity 0<br />
2 INGREDIENTS / HAZARDS CLASSIFICATION<br />
NON-HAZARDOUS SOLUTION AS PER OSHA’S HAZARD COMMUNICATIONS STANDARD (29 CFR 1910.1200)<br />
3 PHYSICAL AND CHEMICAL <strong>DATA</strong><br />
Boiling Point: Not determined. Specific Gravity: 1.007-1.017@ 25° C<br />
Vapor Pressure: Not determined. Vapor Density (Air=1): Not determined.<br />
pH Value : 4.0 – 6.0 Volatility : Negligible.<br />
Stability : Stable. Solubility in Water: Complete.<br />
Appearance & Odor:<br />
Clear, light straw color. Clean, fresh-like, characteristics of<br />
fragrance.<br />
4 FIRE AND EXPLOSION HAZARD <strong>DATA</strong><br />
Flash Point:<br />
Extinguishing Media:<br />
Non-flammable. Ref. Setaflash Closed Tester, ASTM D-3278 @<br />
ambient. No flash up at 105 0 C (221 0 F) - limit of instrument.<br />
Will not burn or propagate flame.<br />
Use appropriate extinguishing media according to the class<br />
of material burning around this solution.<br />
Sage <strong>MSDS</strong> #93 1
5 REACTIVITY <strong>DATA</strong><br />
STABILITY: STABLE<br />
Hazardous Polymerization:<br />
Incompatibilities:<br />
Will not occur.<br />
None known<br />
Decomposition Products May Include:<br />
None known<br />
6 HEALTH HAZARD <strong>DATA</strong><br />
EMERGENCY FIRST AID PROCEDURES: HANDLE IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE<br />
AND <strong>SAFETY</strong> PRACTICES.<br />
Ingestion:<br />
Eye Contact:<br />
Skin Contact:<br />
Non-toxic. Seek medical attention immediately if taken internally.<br />
Non-irritating.<br />
Non-irritating.<br />
(Ref.: FHSA Primary Dermal and Eye Irritation tests).<br />
7 SPILL OR LEAK PROCEDURES<br />
STEPS TO BE TAKEN IF <strong>MATERIAL</strong> IS RELEASED OR SPILLED: CONTAIN ALL SPILLED<br />
<strong>MATERIAL</strong>. ABSORB <strong>MATERIAL</strong> WITH INERT <strong>MATERIAL</strong> AND PLACE IN DRY CONTAINERS FOR<br />
DISPOSAL.<br />
Waste Disposal Method:<br />
8 SPECIAL PROTECTION INFORMATION<br />
Respiratory Protection: Not usually required.<br />
Dispose off in accordance with all local, state and federal<br />
regulations. Warning: most POTW prohibits disposing waste<br />
liquid with pH value 9.5. Check with your local<br />
waste treatment plant office.<br />
Protective Gloves:<br />
Not usually required. For unusually prolonged exposure use<br />
chemical resistant, gauntlet type or equivalent.<br />
Eye Protection:<br />
9 SPECIAL PRECAUTIONS<br />
Not usually required, but wear chemical splash goggles or<br />
face shield when condition requires.<br />
For Chemical Emergency Domestic North America (800) 424-9300<br />
Spill, Leak, Fire, Exposure, or International, Call (703) 527-3887 (Collect Calls<br />
Accident<br />
Accepted)<br />
Call CHEMTREC Day or Night<br />
10 PREPARATION OF <strong>MSDS</strong><br />
Prepared by Safety Department on: October 21, 1998<br />
This data was prepared from current, reliable sources, however, Sage Products Inc. makes<br />
no warranty regarding its accuracy. Because of conditions beyond our control, it is the<br />
user’s responsibility to determine safe conditions for usage.<br />
Rev. 8th: 05/26/06<br />
Sage <strong>MSDS</strong> #93 2
Sage <strong>MSDS</strong> #93 3