SIJECT...
SIJECT...
SIJECT...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Automation and Drives<br />
IJECT 16i/16iP<br />
SMarketing Information<br />
Product Series for Injection Molding Control
Automation and Drives<br />
Components of an Injection Molding Machine<br />
typically controlled by micro controller<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
Cores<br />
Ejector<br />
Temperature control<br />
Injection unit<br />
Carriage<br />
CI16i ...<br />
• CI16i / CI16iP<br />
Tool<br />
• CI16i / CI 16iP<br />
Extension<br />
Zone Heating<br />
Dosing Screw<br />
OP‘s<br />
Injection Rams<br />
Software<br />
Appendix<br />
Closing unit<br />
Proportional valves<br />
Solution: <strong>SIJECT</strong> CI 16i / CI 16iP<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
2
Automation and Drives<br />
Contents<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
• <strong>SIJECT</strong> 16i CS<br />
• CI16i ...<br />
• OP‘s<br />
• Software<br />
• Appendix<br />
Appendix<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
3
Automation and Drives<br />
<strong>SIJECT</strong> 16i CS, „Complete Set“<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Ready to apply Solution for<br />
Standard open Loop machines<br />
System <strong>SIJECT</strong> 16i CS:<br />
• <strong>SIJECT</strong> CI 16i Controller<br />
• <strong>SIJECT</strong> OP 15B - FV1 Operator Panel<br />
(English, Chinese, Turkish, Russian)<br />
• Software + Documentation<br />
Editierbar unter:<br />
• VB 6.0<br />
Open Loop<br />
<strong>SIJECT</strong> 16<br />
complete set<br />
(CI16 i + OP15B)<br />
Standard, Low End Solution<br />
6AT1131-6CD21-0XB0<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
4
Automation and Drives<br />
Contents<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
• <strong>SIJECT</strong> 16i CS<br />
• CI16i ...<br />
• OP‘s<br />
• Software<br />
• Appendix<br />
Appendix<br />
Download Link for <strong>SIJECT</strong>: www.ad.siemens.de/support<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
5
Automation and Drives<br />
CI board<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i // CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
On board<br />
• SIMATIC® S7-300 integrated<br />
• digital inputs<br />
• digital outputs<br />
• analog inputs<br />
• analog outputs<br />
• MPI interface<br />
• P-Bus interface<br />
• PROFIBUS interface (CI 16iP)<br />
• Slot for MMC card<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
6
<strong>SIJECT</strong> Series<br />
Overview<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i // CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
CI 16i Standard Machines<br />
CPU 314 (memory >128k code)<br />
• 24 VDC Power Supply<br />
• Automatic MMC Program Upload<br />
• 31 x Inputs<br />
• 1 x Input counter (1 kHz)<br />
• 40 x Outputs 2A (Short protected)<br />
• 8 x Analog inputs for TC (J/K)<br />
• 4 x Analog inputs for linear scales<br />
• 4 x Analog Outputs 0-10 VDC<br />
• 2 x Analog Valve amp. Outputs 2A<br />
CI 16iP Advanced Machines<br />
CPU 314C-2DP (memory 500k code)<br />
• inputs + outputs same as CI 16i<br />
+<br />
• 2 x High Speed Analog Inputs<br />
• integrated PROFIBUS DP - Interface<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
7
<strong>SIJECT</strong> CI 16i/CI 16iP<br />
Software and Functionality<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i // CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Key Features:<br />
• powerful Standard PLC based on<br />
SIMATIC S7-300<br />
• <strong>SIJECT</strong> CI 16i = CPU S7-314<br />
• <strong>SIJECT</strong> CI 16iP =<br />
CPU S7-314C- 2DP<br />
• Easy Programming and Machine Adaptation<br />
with Standard SIMATIC Step 7 Tool<br />
• Programming in LAD / FDB / STL<br />
• Configuring, testing, commissioning and service<br />
• Operation/diagnostics functions<br />
• Perfect solution for IM machines with<br />
various options and auxiliary equipment<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
8
Automation and Drives<br />
Extension of CI 16iP with standard S7-300<br />
peripheries<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
SIMATIC S7 extensions<br />
racks via IM361 with<br />
digital and analog<br />
peripheries<br />
• CI16i // CI CI 16iP<br />
Extension<br />
MPI<br />
OP‘s<br />
Software<br />
Appendix<br />
RS422<br />
P-Bus Extension<br />
OP 170B<br />
(1/4 VGA b/w) +<br />
Keyboard basic<br />
<strong>SIJECT</strong> IM<br />
<strong>SIJECT</strong> CI 16iP<br />
IM 360 integrated!<br />
IM 361<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
9
Automation and Drives<br />
Extension of CI 16iP with standard S7-300<br />
peripheries<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
Einfache Erweiterbarkeit<br />
mit SIMATIC ® S7 - 300<br />
Peripherie – Baugruppen<br />
(SM-Module)<br />
• CI16i // CI CI 16iP<br />
Extension<br />
MPI<br />
OP‘s<br />
Software<br />
Appendix<br />
RS422<br />
P-Bus Extension<br />
TP 270/MP 370<br />
(10/12“ Farbe)<br />
+ Keyboard<br />
advanced<br />
<strong>SIJECT</strong> IM<br />
<strong>SIJECT</strong> CI 16iP<br />
IM 360 integriert!<br />
IM 361<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
10
Automation and Drives<br />
<strong>SIJECT</strong> with PROFIBUS DP<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
PROFIBUS DP<br />
• CI16i // CI CI 16iP<br />
Extension<br />
MPI<br />
OP‘s<br />
Software<br />
Appendix<br />
RS422<br />
TP 270/MP 370<br />
(10/12“ colour)<br />
+ Keyboard<br />
advanced<br />
<strong>SIJECT</strong> IM<br />
<strong>SIJECT</strong> CI 16iP<br />
<strong>SIJECT</strong> Periphere<br />
ET 200 S / M / X / L<br />
Masterdrive<br />
Simodrive<br />
....<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
11
Automation and Drives<br />
<strong>SIJECT</strong> CI 16iP + E510 with PROFIBUS DP<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
PROFIBUS DP<br />
• CI16i // CI CI 16iP<br />
Extension<br />
MPI<br />
OP‘s<br />
Software<br />
Appendix<br />
TP 270/MP 370<br />
(10/12“ Farbe)<br />
+ Keyboard<br />
advanced<br />
<strong>SIJECT</strong> IM<br />
RS422<br />
<strong>SIJECT</strong> CI 16iP<br />
SIMOTION E510 incl.<br />
1 x Option module:<br />
• 32 DI<br />
• 24 DO, 0,5A<br />
• 24 DO, 2,0A<br />
• 16 Thermocouple (J and K)<br />
• 8 AI fast<br />
• 8 AO fast<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
12
<strong>SIJECT</strong> CI 16i / CI 16iP<br />
Software and Functionality<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i // CI CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
• Open system with integrated standard SIMATIC® S7 - 300 PLC<br />
• Easy Programming and Machine Adaptation with Standard<br />
SIMATIC® S7 - Tools<br />
• Integrated SIMATIC® S7 P-Bus interface and integrated IM 360<br />
• easy expandable with all standard SIMATIC® signal modules<br />
• Integrated PROFIBUS interface opens the world<br />
of decentralized automation<br />
Appendix<br />
Perfect solution for automate your injection molding<br />
machine<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
13
Automation and Drives<br />
Contents<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
• <strong>SIJECT</strong> 16i CS<br />
• CI16i ...<br />
• OP‘s<br />
• Software<br />
• Appendix<br />
Appendix<br />
Download Link for <strong>SIJECT</strong>: www.ad.siemens.de/support<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
14
Automation and Drives<br />
Operator Panels for <strong>SIJECT</strong><br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
OP 15B<br />
5,7“, STN, LCD (320 x 240)<br />
pixels, 115 x 86 mm Display<br />
area, with 71 Keys,<br />
ready Screens,for open loop<br />
Machines<br />
OP 170B<br />
(1/4 VGA, b/w) with ProTool<br />
light / with keyboard basic<br />
<strong>SIJECT</strong> IM<br />
TP 270/MP 270B/MP 370<br />
(10”,12”, 15” VGA, color) with<br />
ProToolPro / with keyboard<br />
advanced <strong>SIJECT</strong> IM<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
15
Automation and Drives<br />
<strong>SIJECT</strong> 16i CS, „Complete Set“<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Ready to apply Solution for<br />
Standard open Loop machines<br />
System <strong>SIJECT</strong>16i CS:<br />
• <strong>SIJECT</strong> CI 16i Controller<br />
• <strong>SIJECT</strong> OP 15B Operator Panel<br />
(English, Chinese, Turkish, Russian)<br />
• Software + Documentation<br />
Editierbar unter:<br />
• VB 6.0<br />
Open Loop<br />
<strong>SIJECT</strong> 16<br />
complete set<br />
(CI16 i + OP15B)<br />
Standard, Low End Solution<br />
6AT1131-6CD21-0XB0<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
16
Automation and Drives<br />
Graphic SIMATIC-HMI-System with OP 170B<br />
ProTool/Pro v 6.0 SP2<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
+<br />
standard SIMATIC<br />
operator panels<br />
Keyboard basic <strong>SIJECT</strong> IM<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
= optimized<br />
operation system<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
17
Automation and Drives<br />
<strong>SIJECT</strong> CI 16i/CI 16iP with SIMATIC OP 170B<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
For open loop machines, with open Graphic – OP<br />
• <strong>SIJECT</strong> CI 16i<br />
• OP 170B<br />
• MPI – cable<br />
• Keyboard basic Siject IM<br />
• Elkom (see Appendix)<br />
• Software + Documentation<br />
• (see Appendix)<br />
Open Loop<br />
Standard, Low End Solution<br />
<strong>SIJECT</strong> CI 16i<br />
6AT1131-6DD21-0AB0<br />
OP 170B<br />
6AV6542-0BB15-2AX0<br />
MPI Cable<br />
6ES7901-0BF00-0AA0<br />
Keyboard basic<br />
Siject IM Elkom Bestell Nr. 110101<br />
Open loop, Runtime Lizenz VSR 020 198 132<br />
Optional usable<br />
<strong>SIJECT</strong> CI 16iP<br />
6AT1131-6DE21-0AB0<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
18
Automation and Drives<br />
CI 16i / CI 16iP + TP 170B + Keyboard basic <strong>SIJECT</strong> IM<br />
Touch, Color, open loop<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
TP 170B,<br />
Color, Touch<br />
MPI<br />
RS422<br />
Touch<br />
Version<br />
Software<br />
Appendix<br />
Open Loop<br />
Keyboard basic <strong>SIJECT</strong> IM<br />
Standard, Low End Solution<br />
<strong>SIJECT</strong> CI 16i<br />
6AT1131-6DD21-0AB0<br />
OP 170B<br />
6AV6542-0BB15-2AX0<br />
MPI Cable<br />
6ES7901-0BF00-0AA0<br />
Keyboard basic<br />
Siject IM Elkom Bestell Nr. 110101<br />
Open loop, Runtime Lizenz VSR 020 198 132<br />
Optional usable<br />
<strong>SIJECT</strong> CI 16iP<br />
6AT1131-6DE21-0AB0<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
19
Automation and Drives<br />
<strong>SIJECT</strong> CI 16iP with SIMATIC Touch Panels<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
+<br />
standard SIMATIC<br />
TP 270 / MP 270 / MP 370<br />
Keyboard advanced<br />
<strong>SIJECT</strong> IM<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
= optimized operation system<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
20
Automation and Drives<br />
<strong>SIJECT</strong> CI 16iP with SIMATIC TP 270<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
For closed loop machines, with open Graphic - OP<br />
• <strong>SIJECT</strong> CI 16iP<br />
• TP 270, 10”, STN, Touch, Color<br />
6AV6545-0CC10-0AX0<br />
• MPI - cable<br />
6ES7901-0BF00-0AA0<br />
• Keyboard advanced <strong>SIJECT</strong> IM<br />
Elkom (see appendix)<br />
• S7-300 extension rack<br />
• IM 361 6ES7361-3CA01-0AA0<br />
• Cable 6ES7368-3BB01-0AA0<br />
• SM 335 6ES7335-7HG01-0AB0<br />
• Power Supply<br />
• Software + Documentation<br />
(see appendix)<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
21
Automation and Drives<br />
CI 16iP + TP 270<br />
10”, STN, Touch, Color, and S7-300 Components<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
TP 170,<br />
10”, STN Touch, Color<br />
MPI<br />
RS422<br />
Closed Loop<br />
Technology<br />
<strong>SIJECT</strong> CI 16iP<br />
Appendix<br />
Closed Loop 2.0<br />
Standard, High End Solution<br />
<strong>SIJECT</strong> CI 16iP<br />
6AT1131-6DE21-0AB0<br />
TP 270, 10”, Touch, Color 6AV6545-0CC10-0AX0<br />
MPI Cable<br />
6ES7901-0BF00-0AA0<br />
Keyboard<br />
advanced <strong>SIJECT</strong> IM Elkom Bestell Nr. 070201<br />
Closed loop, Runtime Lizenz VSR 020 195 002<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
22
Automation and Drives<br />
CI 16iP + MP 270B<br />
10”, TFT, Touch, Color, and S7-300 Components<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
MP 270B,<br />
10”, TFT Touch, Color<br />
MPI<br />
RS422<br />
Closed Loop<br />
Technology<br />
<strong>SIJECT</strong> CI 16iP<br />
Appendix<br />
Closed Loop 2.0<br />
Standard, High End Solution<br />
<strong>SIJECT</strong> CI 16iP<br />
6AT1131-6DE21-0AB0<br />
MP 270B, 10”, Touch, Color 6AV6545-0CC10-0AX0<br />
MPI Cable<br />
6ES7901-0BF00-0AA0<br />
Keyboard<br />
advanced <strong>SIJECT</strong> IM Elkom Bestell Nr. 070201<br />
Closed loop, Runtime Lizenz VSR 020 195 002<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
23
Automation and Drives<br />
CI 16iP + MP 370<br />
12”, TFT, Touch, Color, and S7-300 Components<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
MP 370,<br />
12”, TFT Touch, Color<br />
MPI<br />
RS422<br />
Closed Loop<br />
Technology<br />
<strong>SIJECT</strong> CI 16iP<br />
Appendix<br />
Open Loop<br />
Standard, Low End Solution<br />
<strong>SIJECT</strong> CI 16iP<br />
6AT1131-6DE21-0AB0<br />
MP 370, 12”, Touch, Color 6AV6545-0CC10-0AX0<br />
MPI Cable<br />
6ES7901-0BF00-0AA0<br />
Keyboard<br />
advanced <strong>SIJECT</strong> IM Elkom Bestell Nr. 070201<br />
Closed loop, Runtime Lizenz VSR 020 195 002<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
24
<strong>SIJECT</strong><br />
Available Injection Molding Solutions<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Module HMI Keys Touch Size Color Technology<br />
<strong>SIJECT</strong> 16i, CS OP 15B Yes No 5.7" B/W open loop<br />
CI 16i OP 170B Yes No 5.7" B/W open loop<br />
CI 16i TP 170B Yes Yes 5.7" Color open loop<br />
Appendix<br />
CI 16iP TP 270 Yes Yes 10" Color closed loop<br />
CI 16iP MP 270B Yes Yes 10" Color closed loop<br />
CI 16iP MP 370 Yes Yes 12“, 15“ Color closed loop<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
25
Automation and Drives<br />
Possible OP‘s<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
HMI versions<br />
OP's<br />
OP 15B - FV1<br />
(English, Chinese, Turkish, Russian)<br />
OP 15B - FV2<br />
(English, Chinese, Spanish, Reserve)<br />
OP 170B<br />
TP 170B<br />
TP 270, 10"<br />
MP 270B, 10"<br />
MP 370, 12"<br />
MP 370, 15"<br />
MLFB<br />
6AT1131-5BB20-0XB0<br />
6AT1131-5BC20-0XB0<br />
6AV6542-0BB15-2AX0<br />
6AV6545-0BC15-2AX0<br />
6AV6545-0CC10-0AX0<br />
6AV6545-0AG10-0AX0<br />
6AV6545-0DA10-0AX0<br />
6AV6545-0DB10-0AX0<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
26
Automation and Drives<br />
Part Number Overview<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
for the Injection Molding Solution<br />
• <strong>SIJECT</strong> 16 CS, Complete Set (CI16 i + OP15B)<br />
• <strong>SIJECT</strong> CI 16i<br />
• <strong>SIJECT</strong> CI 16iP<br />
• <strong>SIJECT</strong> OP 15B – FV1 (English, Chinese, Turkish, Russian)<br />
• <strong>SIJECT</strong> OP 15B – FV2 (English, Chinese, Spanish, Reserve)<br />
Optional Parts<br />
• MMC<br />
• Compact Flash 32 MB<br />
• USB Floppy Drive 3 ½”<br />
6AT1131-6CD21-0XB0<br />
6AT1131-6DD21-0AB0<br />
6AT1131-6DE21-0AB0<br />
6AT1131-5BB20-0XB0<br />
6AT1131-5BB20-0XB0<br />
6AT1131-0GA00-0AA0<br />
6AV6574-2AC00-2AA0<br />
6FC5235-0AA05-1AA1<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
27
Automation and Drives<br />
Part Number Overview<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
for the Injection Molding Solution<br />
Optional Parts<br />
• DIN rail 530mm<br />
• PS307 (5A 24VDC)<br />
• IM361<br />
• Kabel IM360 – IM361, 1m<br />
• IM 153-1 Interface module<br />
• SM 321 DI 16<br />
• SM 321 DI 32<br />
• SM 322 DO 8<br />
• SM 322 DO 16<br />
• SM 331 AI 8 (Thermocouple Module)<br />
• SM 331 AI 2 (12Bit)<br />
• SM 334 AI 8 (14Bit)<br />
• SM 332 AO 4 (12Bit)<br />
• Front connector 20 Pin.<br />
• Front connector 40 Pin.<br />
• Profibus connector 90 Degrees<br />
• Profibus connector 90 Degrees PG, socket<br />
• Profibus cable 50m<br />
6ES7390-1AF30-0AA0<br />
6ES7307-1EA00-0AA0<br />
6ES7361-3CA01-0AA0<br />
6ES7368-3BB01-0AA0<br />
6ES7153-1AA03-0XB0<br />
6ES7321-1BH02-0AA0<br />
6ES7321-1BL00-0AA0<br />
6ES7322-1BF01-0AA0<br />
6ES7322-1BH01-0AA0<br />
6ES7331-7PF10-0AB0<br />
6ES7331-7KB01-0AB0<br />
6ES7334-0CE01-0AA0<br />
6ES7332-5HD01-0AB0<br />
6ES7392-1AJ00-0AA0<br />
6ES7392-1AM00-0AA0<br />
6ES7972-0BA50-0XA0<br />
6ES7972-0BB50-0XA0<br />
6XV1830-0EN50<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
28
Automation and Drives<br />
Contents<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
• <strong>SIJECT</strong> 16i CS<br />
• CI16i ...<br />
• OP‘s<br />
• Software<br />
• Appendix<br />
ProTool/Pro v 6.0 SP2<br />
Download Link for <strong>SIJECT</strong>: www.ad.siemens.de/support<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
29
<strong>SIJECT</strong> CI 16i /CI 16iP<br />
Software and Functionality<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Key Features:<br />
• Easy Programming and Machine Adaptation<br />
with Standard SIMATIC Step 7 Tool<br />
• Configuring and parameterize the hardware<br />
• Programming in LAD / FDB / STL<br />
• Testing, commissioning and service<br />
• Documentation<br />
• Operation/diagnostics functions<br />
• Easy Programming and Machine Adaptation<br />
with Standard SIMATIC Step 7 Tool<br />
• Open loop program with OP 15B or OP 170B<br />
• Closed loop program with TP 270, MP 270B or MP 370<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
30
Automation and Drives<br />
<strong>SIJECT</strong> 16: HMI Software<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
ProTool/Lite V6.0+SP3 for<br />
OP 170<br />
• Configuration Software<br />
• MLFB: 6AV6580-3BX06-0DX0<br />
• no run time license necessary<br />
ProTool/Pro V6.0+SP3 for<br />
TP 270 or MP 270B / MP 370<br />
• Configuration Software<br />
• MLFB: 6AV6581-3BX06-0DX0<br />
• Run Time Software V6.0+SP3<br />
(2048 power tags)<br />
• MLFB: 6A6584-1AF06-0DX0<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
31
Automation and Drives<br />
Software – Support for <strong>SIJECT</strong><br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Complete HMI – Projects<br />
• OP 170B<br />
• TP 270 / MP 270B / MP 370<br />
Complete STEP 7 – Programs<br />
• <strong>SIJECT</strong> CI 16i / CI16iP<br />
• Open loop / Closed loop<br />
Open Loop Closed Loop 2.0<br />
<strong>SIJECT</strong> IM (Closed Loop) 2.0<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
32
Automation and Drives<br />
Functions (Closed Loop)<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Highlights:<br />
• Diagnostic and Status screens ( D/I, D/A, A/I, A/O )<br />
• Unit switching ( Online )<br />
• Handling Euromap 12 – Interface<br />
• Control for central plunger cylinder<br />
• Power driven safety gate<br />
• 4 Core puller<br />
• Toggle system – Mold Height Adjustment<br />
• 4 Air Blast<br />
• Machine-Cycle status display<br />
• QS data table<br />
• Password Level<br />
• Motor star- delta - Control 2x<br />
• Cleaning program ( Nozzle)<br />
• Automatic purge control<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
33
Automation and Drives<br />
Functions (Closed Loop)<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Highlights:<br />
• Automatic lubrication control<br />
• Language ( 5x online switch able / all available world Languages<br />
offline project able),<br />
• Soft key retrace of the last 6 opened screens<br />
• Previous screen button<br />
• Alarm messages ( 256 ) will be stored<br />
• Accumulator control<br />
• Standard toggle / Full – hydraulic machine<br />
• Temperature Auto tuning<br />
• Touch Screen<br />
• Easy PLC-Recovery (MMC-Card)<br />
• 8 additional Heating / cooling zones<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
34
Automation and Drives<br />
New, Add. Functions (Closed Loop) 2.0<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
New or modified Highlights:<br />
• CI16iP supported.<br />
• New machine type concept allowed same type of program for<br />
different machines<br />
• Quality data table. New concept, 16 rows with 200 data per field.<br />
(64 free selectable data, with free cycle step selecting).<br />
• Mold gate control 16x.<br />
• Core control 8x. Upgrade to 8 core controls and new priority<br />
concept 8x.<br />
• Hydraulic actions. Upgrade from 32 pre-prepared actions to 48.<br />
• Automatic clamp force adjustment for toggle system machines.<br />
Clamp force sensor required<br />
• Mold height position sensor for toggle system machines.<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
35
Automation and Drives<br />
New, Add. Functions (Closed Loop) 2.0<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
New or modified Highlights:<br />
• Digital input / output re-arrangement for maintenance purpose.<br />
• Injection process step number limitation 6x.<br />
• Holding pressure step number limitation 5x.<br />
• Dosing step number limitation 3x.<br />
• New Standard S7-Temperature control FB58 used.<br />
• New temperature alarm concept.<br />
• Mold data recipes transfer modified.<br />
(Add. warning before uploading of empty recipes files)<br />
• Export of recipes to CSV file.<br />
• Duration of a period setting for heater/cooler outputs separately<br />
• New special movement concept for special program sequences<br />
like (Core, Ejector, and/or other add functions …)<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
36
Automation and Drives<br />
Functions (Closed Loop)<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Optional:<br />
• Diagnostic and Status screens<br />
( D/I, D/A, A/I, A/O )<br />
• Gate control<br />
• Hot runner<br />
• MDA (Machine data acquisition)<br />
• Tempering unit control / (closed loop)<br />
• Swivel disk control<br />
• Mold change control<br />
• Closed loop toggle force control<br />
• Ethernet converter<br />
Optional Thermo set:<br />
• Ventilate / Stamping<br />
• Darner / Darner (Closed Loop)<br />
• Tempering unit control / (closed loop)<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
37
<strong>SIJECT</strong> IM<br />
(Open Loop) (Closed Loop)<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
<strong>SIJECT</strong> IM (Open Loop) <strong>SIJECT</strong> IM (Closed Loop) 2.0<br />
Alarm messages ( 256 ) will be stored x x Alarm messages ( 256 ) will be stored<br />
Operating Messages x x Operating Messages<br />
Diagnostic and Status screens<br />
( D/I, D/A, A/I, A/O )<br />
x x Diagnostic and Status screens ( D/I, D/A, A/I, A/O )<br />
x Unit switching ( Online )<br />
x Handling Euromap 12 – Interface<br />
x Power driven safety gate<br />
3 Core puller prepared x x 8 Core puller<br />
x<br />
Core control 8x. Upgrade to 8 core controls and new priority<br />
concept 8x.<br />
Toggle system – Mold Height Adjustment x x Toggle system – Mold Height Adjustment<br />
2 Air Blast x 4 Air Blast<br />
Machine-Cycle status display x x Machine-Cycle status display<br />
x QS data table<br />
Password Level x x Password Level<br />
Motor star- delta - Control 1x x x Motor star- delta - Control 2x<br />
x Cleaning program ( Nozzle)<br />
Automatic lubrication control x x Automatic lubrication control<br />
Language ( 2x online switchable / all<br />
available world Languages offline project<br />
able),<br />
x x<br />
Language ( 5x online switchable / all available world Languages<br />
offline project able),<br />
x Soft key retrace of the last 6 opened screens<br />
x Accumulator control<br />
Standard toggle / Full – hydraulic machine x x Standard toggle / Full – hydraulic machine<br />
8 Temperature Zones x x 8 Temperature Zones<br />
x 8 additional Heating / cooling zones<br />
x Temperature Auto tuning<br />
x Touch Screen<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
38
<strong>SIJECT</strong> IM<br />
(Open Loop) (Closed Loop)<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
<strong>SIJECT</strong> IM (Open Loop) <strong>SIJECT</strong> IM (Closed Loop) 2.0<br />
Automatic Easy PLC-Recovery (MMC-Card) x x Automatic Easy PLC-Recovery (MMC-Card)<br />
Unterstützung der neuen Steuerung<br />
<strong>SIJECT</strong> CI16iP.<br />
x x<br />
x<br />
x<br />
CI16iP supported.<br />
New machinetypeconceptallowedsametypeof programfor<br />
different machines different Types of Injection Molding<br />
Machines<br />
Quality data table. New concept, 16 rows with 200 data per<br />
field. (64 free selectable data, with free cycle step selecting).<br />
x Mold gate control 16x.<br />
x Hydraulic actions. Upgrade from 32 pre-prepared actions to 48.<br />
x<br />
Automatic clamp force adjustment for toggle system machines.<br />
Clamp force sensor required<br />
x Mold height position sensor for toggle system machines.<br />
Mold Closing profile- 3 x x x Mold Closing profile- 3 x<br />
Mold Open Profile- 3x x x Mold Open Profile- 3x<br />
Ejector- Forward 2x x x Ejector- Forward 2x<br />
Ejector- Back 2x x x Ejector- Back 2x<br />
Injection process step number limitation 6x. x x Injection process step number limitation 6x.<br />
Holding pressure step number limitation 5x. x x Holding pressure step number limitation 5x.<br />
Dosing step number limitation 3x. x x Dosing step number limitation 3x.<br />
Decompression x x Decompression<br />
x New Standard S7-Temperature control FB58 used.<br />
x New temperature alarm concept.<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
39
<strong>SIJECT</strong> IM<br />
(Open Loop) (Closed Loop)<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
<strong>SIJECT</strong> IM (Open Loop) <strong>SIJECT</strong> IM (Closed Loop) 2.0<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
Mold data recipes transfer modified.<br />
(Add. warning before uploading of empty recipes files)<br />
Export of recipes to CSV file.<br />
Duration of a period setting for heater/cooler outputs separately<br />
New special movement concept for special program sequences<br />
like (Core, Ejector, and/or other add functions …)<br />
Ethernet converter<br />
Hot runner<br />
MDA (Machine data acquisition)<br />
Swivel disk control<br />
Mold change control<br />
Thermoset<br />
x<br />
x<br />
x<br />
x<br />
x<br />
Stamping<br />
Degassing<br />
Stufferelevatorcontrol<br />
Stuffer Unit Program<br />
Up to 64 add. Temperature zones with Current Monitoring<br />
Remark:( add. CPU required)<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
40
Software – Support for <strong>SIJECT</strong><br />
Order Data<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
Open loop<br />
CI16i ...<br />
<strong>SIJECT</strong> Technology - Package<br />
on CD Master License<br />
Runtime – License<br />
(for one <strong>SIJECT</strong>)<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
PLC –Application program<br />
for <strong>SIJECT</strong> CI 16i<br />
and<br />
Order-Nr:<br />
VSR 020 194 988<br />
Order-Nr:<br />
VSR 020 198 132<br />
OP‘s<br />
HMI –<br />
Project for SIMATIC OP 170B<br />
Software<br />
Closed loop 2.0<br />
Appendix<br />
<strong>SIJECT</strong> Technology - Package<br />
on CD Master License<br />
Runtime – License<br />
(for one <strong>SIJECT</strong>)<br />
PLC –Application program<br />
for <strong>SIJECT</strong> CI 16 iP<br />
and<br />
HMI –<br />
Project for SIMATIC TP 270 /<br />
MP 270B Touch / MP 370 Touch<br />
Order-Nr:<br />
VSR 020 198 133<br />
Order-Nr:<br />
VSR 020 195 002<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
41
<strong>SIJECT</strong> 16<br />
Software and Functionality<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Easy to set up and commission<br />
prepared screen sets for application<br />
example PLC-Program for machine logic<br />
Compact, easy installation and handling<br />
User manuals<br />
Download Link for <strong>SIJECT</strong>: www.ad.siemens.de/support<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
42
Automation and Drives<br />
Contents<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
• <strong>SIJECT</strong> 16i CS<br />
• CI16i ...<br />
• OP‘s<br />
• Software<br />
• Appendix<br />
Appendix<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
43
Automation and Drives<br />
Keyboard basic <strong>SIJECT</strong> IM<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Ordering address<br />
elkom elektronik GmbH<br />
Niedervellmarer Str. 41d<br />
D-34127 Kassel<br />
Germany<br />
Phone: +49 (0) 561 989 37-13<br />
Telefax: +49 (0) 561 989 37-15<br />
E-Mail: elkom-elektronik@t-online.de<br />
Web: http://www.elkom-elektronik.de<br />
Product<br />
Keyboard basic <strong>SIJECT</strong> IM, with cable<br />
4 fixation parts and documentation<br />
1 ... 10 pieces<br />
11 ... 100 pieces<br />
101 ... 300 pieces<br />
more than 300 pieces<br />
Order Number<br />
110101<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
44
Automation and Drives<br />
Keyboard basic <strong>SIJECT</strong> IM, Spares<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
Spares<br />
Order Number<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
cable 5m 110102<br />
4x fixing parts 110103<br />
emergency stop switch 110104<br />
documentation (CD) 110105<br />
Customer Versions<br />
customer specific foil 110106<br />
incl. 3 Design Suggestions<br />
customer specific keyboard 110107<br />
incl. 3 Design Suggestions<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
45
Fitting Measurement :<br />
OP 170B + Keyboard basic <strong>SIJECT</strong> IM<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
Vertical<br />
240 mm<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
10 mm<br />
240 mm<br />
490 mm<br />
Software<br />
Appendix<br />
Horizontal<br />
490 mm<br />
230 mm<br />
230 mm<br />
240 mm 240 mm<br />
10 mm<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
46
Automation and Drives<br />
Keyboard advanced <strong>SIJECT</strong> IM<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Ordering address<br />
elkom elektronik GmbH<br />
Niedervellmarer Str. 41d<br />
D-34127 Kassel<br />
Germany<br />
Phone: +49 (0) 561 989 37-13<br />
Telefax: +49 (0) 561 989 37-15<br />
E-Mail: elkom-elektronik@t-online.de<br />
Web: http://www.elkom-elektronik.de<br />
Appendix<br />
Product<br />
Keyboard advanced <strong>SIJECT</strong> IM, with cable<br />
4 fixation parts and documentation<br />
1 ... 10 pieces<br />
11 ... 100 pieces<br />
101 ... 300 pieces<br />
more than 300 pieces<br />
Order Number<br />
070201<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
47
Automation and Drives<br />
Keyboard advanced <strong>SIJECT</strong> IM, Spares<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
Spares<br />
Order Number<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
cable 5m 110102<br />
4x fixing parts 110103<br />
emergency stop switch 110104<br />
documentation (CD) 070202<br />
Customer Versions<br />
customer specific foil 070203<br />
incl. 3 Design Suggestions<br />
customer specific keyboard 070204<br />
incl. 3 Design Suggestions<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
48
Automation and Drives<br />
Fitting Measurement:<br />
MP 270B + Keyboard advanced <strong>SIJECT</strong> IM<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
Vertical<br />
260 mm<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
20 mm<br />
260 mm<br />
540 mm<br />
Software<br />
Appendix<br />
Horizontal<br />
540 mm<br />
320 mm<br />
320 mm<br />
260 mm 260 mm<br />
20 mm<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
49
Dimensions<br />
OP15B and CI 16i / CI 16iP<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
50
Automation and Drives<br />
MMC = Multi Media Card<br />
Automatic Easy PLC-Recovery (MMC-Card) Function<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
1. Recipes:<br />
50 on the MMC<br />
30 on the „<strong>SIJECT</strong>...“<br />
2. PLC – Machine program<br />
3. Technology Software<br />
(TECH)<br />
4. Start- Page for OP15B<br />
1<br />
2 3 4 5 6<br />
24,0 mm<br />
7<br />
32 mm<br />
Appendix<br />
Standard Memory Card (8 - 32 Mbyte)<br />
Fully compliant with industry standards Miniature<br />
postage stamp size<br />
Low power consumption to conserve battery life<br />
MMC 32 MB<br />
Compact Flash 16 MB<br />
MLFB: 6AT1131-0GA00-0AA0<br />
MLFB: 6AV6574-2AC00-2AA0<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
51
Additional<br />
USB Floppy for<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
TP 270 / MP 270B / MP 370<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
USB Floppy for WIN CE 3.0<br />
MLFB: 6FC5235-0AA05-1AA1<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
52
Third party<br />
USB “Win CE” Printer<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
MPI / Ethernet<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
HP Deskjet 450 Ci<br />
HP Deskjet<br />
9650/9670/9680<br />
Software<br />
Appendix<br />
Canon BJC 85<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
53
Third party product for<br />
MPI / Ethernet conversion<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
IBHsoftec<br />
www.IBHsoftec.de<br />
IBH Link<br />
MPI / Ethernet<br />
OP‘s<br />
Software<br />
Appendix<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
54
MDA<br />
Machine Data Acquisition<br />
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Evaluation – Overview<br />
Standard Evaluation<br />
• Logbook / log for machine statuses<br />
• Behavior of statuses over time<br />
• Fault cause analysis with duration and frequency<br />
• Determination of the machine<br />
availability, utilization, etc.<br />
• Machine messages and alarms<br />
Individual Evaluation<br />
• Data in MS-ACCESS format<br />
• Access via LAN, e.g. via MS-EXCEL<br />
• Implement. of customer-specific<br />
requirements<br />
• Online customizing<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
55
Automation and Drives<br />
<strong>SIJECT</strong> 16<br />
<strong>SIJECT</strong> 16i CS<br />
CI16i ...<br />
• CI16i / CI16iP<br />
• CI16i / CI 16iP<br />
Extension<br />
OP‘s<br />
Software<br />
Appendix<br />
Thanks for<br />
your Attention<br />
Wolfgang Radermacher<br />
wolfgang.radermacher@siemens.com<br />
Phone: +49 (9131) 98 2208<br />
Fax: +49 (9131) 98 2121<br />
Wolfgang Zapf<br />
wolfgang.zapf@siemens.com<br />
Phone: +49 (9131) 98 2065<br />
Fax: +49 (9131) 98 2121<br />
Download Link for <strong>SIJECT</strong>: www.ad.siemens.de/support<br />
<strong>SIJECT</strong> CI 16i / CI 16iP IM Application<br />
56