12.06.2014 Views

Agilent 7000A Triple Quadrupole GC/MS - Research Institute for ...

Agilent 7000A Triple Quadrupole GC/MS - Research Institute for ...

Agilent 7000A Triple Quadrupole GC/MS - Research Institute for ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Agilent</strong> <strong>7000A</strong> <strong>Triple</strong> <strong>Quadrupole</strong> <strong>GC</strong>/<strong>MS</strong><br />

Target compound analysis at the lowest limits of detection.<br />

Our measure is your success.<br />

products | applications | soft ware | services


<strong>Agilent</strong> <strong>7000A</strong> <strong>Triple</strong> <strong>Quadrupole</strong> <strong>GC</strong>/<strong>MS</strong><br />

Extraordinary sensitivity and selectivity—day after day.<br />

<strong>Agilent</strong>’s new <strong>7000A</strong> <strong>Triple</strong> <strong>Quadrupole</strong> <strong>GC</strong>/<strong>MS</strong> delivers lower limits of detection and advanced high-speed <strong>GC</strong>/<strong>MS</strong>/<strong>MS</strong><br />

quantification, even with the dirtiest samples in the most demanding environments. Engineered from the ground up as an<br />

easy-to-use <strong>GC</strong>/<strong>MS</strong> <strong>Triple</strong> Quad <strong>for</strong> routine high per<strong>for</strong>mance operation, this breakthrough system is the ideal choice <strong>for</strong><br />

labs requiring maximum sensitivity, maximum uptime, and maximum productivity.<br />

The <strong>Agilent</strong> <strong>7000A</strong> <strong>Triple</strong> <strong>Quadrupole</strong> <strong>GC</strong>/<strong>MS</strong> combines industry-leading<br />

reliability with femtogram-level sensitivity in complex matrices.<br />

2


Pw50 0.60<br />

Pw50 0.60<br />

Pw50 0.60<br />

66 71 216 221 500 505<br />

Industry-leading sensitivity and selectivity<br />

Whether you are measuring pesticides in food and water, drugs in<br />

complex biological matrices, or contaminants in environmental<br />

samples, the <strong>7000A</strong> system helps you meet the increasing demand <strong>for</strong><br />

trace-level detection of target analytes. The combination of <strong>Agilent</strong>’s<br />

proprietary solid inert ion source, proven quartz quadrupoles, innovative<br />

collision cell design, and new triple-axis detector provides:<br />

• Routine femtogram-level sensitivity<br />

• Superior selectivity<br />

• Ultra-low noise<br />

• Outstanding data acquisition speed<br />

Faster analysis, higher throughput<br />

Acquisition speeds of up to 500 MRM transitions per second<br />

match the front-end per<strong>for</strong>mance of the fastest chromatography<br />

without compromising data quality—enabling you to automatically<br />

quantify and confirm more targets in a single method. Powerful,<br />

easy-to-use data analysis, review and reporting tools let you process<br />

more samples in less time with complete confidence in your results.<br />

Day-after-day reliability and simple operation<br />

So that every laboratory can take advantage of the advanced<br />

capabilities of the <strong>7000A</strong> <strong>Triple</strong> Quad, the system incorporates<br />

proven, highly reliable technology developed specifically <strong>for</strong><br />

<strong>GC</strong>/<strong>MS</strong> applications. For example, the rugged inert ion source, the<br />

differentially pumped configuration, and the heated, gold-plated<br />

hyperbolic quartz quadrupoles keep routine <strong>MS</strong> maintenance to<br />

a minimum. Advanced set-up, configuration, proven AutoTune<br />

technology, and powerful manual tuning tools enable quick start-up<br />

<strong>for</strong> quantitative analyses.<br />

Mass 69.00<br />

ab 426330<br />

Mass 218.00<br />

ab 362315<br />

Mass 502.00<br />

ab 45942<br />

Inert, ultra-reliable ion source<br />

<strong>Agilent</strong>’s unique, dual-filament ion source<br />

design increases productivity and reduces<br />

cleaning requirements, especially when<br />

analyzing dirty samples. Programmable up<br />

to 350˚C, the source is solid inert material—<br />

not a coating—so you can run sample after<br />

sample with complete confidence.<br />

Proprietary gold quartz quadrupole<br />

with 1050 u mass range<br />

<strong>Agilent</strong>’s proprietary gold-plated hyperbolic<br />

quartz quadrupole analyzer offers high<br />

temperature stability and can be heated to<br />

200°C. Because the quadrupole can be kept<br />

at this high temperature and at vacuum, it stays<br />

clean even with the complex, high boiling<br />

samples—eliminating frequent retuning<br />

time-consuming maintenance and ensuring<br />

superior mass analyzer per<strong>for</strong>mance.<br />

New, proprietary hexapole<br />

collision cell technology<br />

The linear acceleration design and novel<br />

helium-quenched system reduces neutral<br />

noise and contributes to outstanding highspeed<br />

per<strong>for</strong>mance without ion ghosting or<br />

cross-talk. A wide mass bandwidth optimizes<br />

sensitivity at all masses while eliminating the<br />

need to tune on your compound.<br />

High S/N <strong>Triple</strong>-Axis Detector<br />

<strong>Agilent</strong>’s next-generation off-axis, triple-channel<br />

detector minimizes noise and maximizes signal<br />

<strong>for</strong> the lowest detection limits. The same<br />

field-proven design is currently incorporated<br />

in all <strong>Agilent</strong> 5975C <strong>GC</strong>/<strong>MS</strong>D systems.<br />

High-sensitivity AutoTune<br />

Simple, automatic tuning takes the trial<br />

and error out of system setup. It saves time,<br />

simplifies operation and improves instrumentto-instrument<br />

consistency. Optimizing ion<br />

transmission, mass axis calibration, mass<br />

resolution, and detector gain-vs.-voltage<br />

significantly boosts per<strong>for</strong>mance, as well.<br />

You can also per<strong>for</strong>m a manual tune if desired<br />

using simple powerful tools.<br />

For additional instrument specifications go to:<br />

www.agilent.com/chem/<strong>7000A</strong><br />

5989-9625EN: <strong>Agilent</strong> <strong>7000A</strong> <strong>GC</strong>/<strong>MS</strong> <strong>Triple</strong> <strong>Quadrupole</strong> System Data Sheet<br />

3


Advanced technologies translate<br />

into everyday high per<strong>for</strong>mance.<br />

Analysis of 100 femtograms<br />

of OFN at >100:1 R<strong>MS</strong> S/N<br />

This EI MRM specification will be<br />

demonstrated on-site at installation<br />

using AutoTune conditions.<br />

Unprecedented sensitivity<br />

<strong>for</strong> target compounds<br />

Chromatogram of two PCB congeners<br />

(PCB 153 and PCB 138) injected at 400 fg<br />

each on-column. Quantitation transition<br />

360—>290 m/z, with the qualifier<br />

transition measured at 360—>325 m/z<br />

<strong>for</strong> simultaneous quantitation and<br />

confirmation at the lowest detection limit.<br />

Multiple Reaction Monitoring<br />

(MRM) helps you make sense<br />

of complicated samples at the<br />

lowest detection limits<br />

Chromatogram of multiple PCB congeners in<br />

mussel extract measured at 2 pg on column.<br />

4


Exceptional selectivity and unquestionable<br />

quantitation—even in the most difficult matrices<br />

Measurement of Chlorpyriphos in Pu-erh tea at a 10 ppb spike.<br />

Tea extract is one of the most complex samples in food safety,<br />

yet the <strong>MS</strong>/<strong>MS</strong> chromatogram is remarkably clean.<br />

Outstanding sensitivity and selectivity—<br />

down to 1 pg on column<br />

Overlay of multiple injections at three different concentrations<br />

from extracts of dried Ashitaba herbs. The analysis also<br />

highlights the exceptional <strong>GC</strong> retention time reproducibility<br />

of the <strong>Agilent</strong> 7890A <strong>GC</strong>.<br />

Area 1 1197<br />

Area 2 1280<br />

Area 3 1347<br />

Area 4 1186<br />

Area 5 1291<br />

Mean 1260<br />

RSD% 5.4<br />

Outstanding reproducibility at trace levels<br />

The organophosphorus insecticide, Cyanophos, spiked into garlic<br />

at 0.5 ppb and analyzed in MRM mode. Overlay of 5 injections<br />

showing the quantitation transition 243-109 m/z.<br />

Easy quantitation even in sediment samples<br />

Easy to quantify <strong>MS</strong>/<strong>MS</strong> chromatograms in the most difficult<br />

environmental samples.<br />

To learn more about the <strong>Agilent</strong> <strong>7000A</strong> <strong>Triple</strong> <strong>Quadrupole</strong> <strong>GC</strong>/<strong>MS</strong>, visit www.agilent.com/chem/<strong>7000A</strong><br />

5


New MassHunter software helps you make the<br />

most of every run and every workday.<br />

To make it easy even <strong>for</strong> non-expert operators to take full advantage of the advanced capabilities of the <strong>Agilent</strong><br />

<strong>7000A</strong> <strong>Triple</strong> <strong>Quadrupole</strong> system, we’ve teamed up <strong>Agilent</strong>’s proven acquisition and control interface with the<br />

powerful MassHunter data analysis and reporting software.<br />

An intuitive user interface enables powerful compound-centric data navigation, “Batch at a Glance” data<br />

review and fast peak integration with quantitation. Consistent software across all <strong>Agilent</strong> <strong>MS</strong> plat<strong>for</strong>ms<br />

improves productivity by shortening learning curves and reducing training costs.<br />

Single-screen acquisition and control.<br />

A single screen gives you access to all instrument<br />

setup and data acquisition parameters.<br />

Powerful MassHunter data analysis. <strong>Agilent</strong> MassHunter<br />

software incorporates advanced “Batch at a Glance”<br />

quantitative data analysis, a proven reliable parameter-less<br />

integrator, and other tools that enable you to quickly and<br />

completely analyze data from large sample sets. Qualitative<br />

analysis tools include a novel spectral library editor and<br />

search routines. Identifications can be achieved from scan<br />

data via a new deconvolution program.<br />

Flexible, fully customizable reports. MassHunter software<br />

stores all results in XML files and uses Microsoft Excel<br />

and a custom macro add-in <strong>for</strong> reporting. A wide range of<br />

application-specific report templates or customized reports<br />

are available in this familiar Excel environment, including<br />

custom calculations to meet specific needs.<br />

6


<strong>Agilent</strong> 7890A <strong>GC</strong>: Critical success<br />

factor <strong>for</strong> <strong>GC</strong>/<strong>MS</strong>/<strong>MS</strong> analysis.<br />

<strong>Agilent</strong>’s new 7890A <strong>GC</strong> is the perfect front-end <strong>for</strong> the<br />

<strong>7000A</strong> <strong>Triple</strong> <strong>Quadrupole</strong> system. The industry-leading<br />

<strong>GC</strong> gives you everything you need to take your lab to the<br />

next level of <strong>GC</strong>/<strong>MS</strong>/<strong>MS</strong> per<strong>for</strong>mance, including advanced<br />

chromatographic capabilities, and powerful new productivity<br />

features, such as Capillary Flow Technology. Plus, of course,<br />

legendary <strong>Agilent</strong> reliability.<br />

<strong>Agilent</strong> per<strong>for</strong>mance and reliability<br />

Fifth-generation electronic pneumatics control (EPC) and<br />

digital electronics set a new benchmark <strong>for</strong> retention time,<br />

precision, and repeatability and help make the 7890A<br />

<strong>Agilent</strong>’s most dependable <strong>GC</strong> ever.<br />

Higher productivity<br />

Faster oven cool-down, advanced automation features, and<br />

faster <strong>GC</strong> oven ramps let you get more done in less time, at<br />

the lowest possible cost per sample—all easily incorporated<br />

into your existing methods.<br />

<strong>Agilent</strong> Capillary Flow technology<br />

Available in a number of useful<br />

configurations, <strong>Agilent</strong>’s inert,<br />

low-dead volume Capillary Flow<br />

devices open the door to highly useful<br />

techniques such as “QuickSwap”<br />

column change-out, flow splitting,<br />

backflushing, and Deans switching<br />

that can save time and resources<br />

and improve your analytical results.<br />

Backflushing shortens analysis time by 33 minutes.<br />

In this analysis, the lower trace employing oven bakeout<br />

takes an additional 33 minutes at 320°C to remove<br />

high boilers that elute after the analytes of interest.<br />

Backflushing (upper trace) removes all the high boiling<br />

components in seven minutes, at only 280°C.<br />

Backflush capability improves data quality, while shortening<br />

cycle time and increasing column life. It reduces ion<br />

source contamination by keeping excess column bleed<br />

and heavy residues from being introduced into the mass<br />

spectrometer. It also eliminates ghost peaks, providing<br />

a significant improvement in data integrity.<br />

To learn more about the <strong>Agilent</strong> <strong>7000A</strong> <strong>Triple</strong> <strong>Quadrupole</strong> <strong>GC</strong>/<strong>MS</strong>, visit www.agilent.com/chem/<strong>7000A</strong><br />

7


Faster, better <strong>GC</strong>/<strong>MS</strong> results with high<br />

per<strong>for</strong>mance <strong>Agilent</strong> J&W columns<br />

Choose <strong>Agilent</strong> J&W Ultra<br />

Inert columns <strong>for</strong> exceptionally<br />

low column bleed providing<br />

improved signal-to-noise ratio<br />

and sensitivity <strong>for</strong> the detector,<br />

fast baseline stabilization <strong>for</strong><br />

minimized conditioning time, and excellent thermal stability<br />

<strong>for</strong> reduced instrument downtime.<br />

<strong>Agilent</strong> supplies help keep routine<br />

maintenance routine<br />

An exclusive non-stick plasma on our premium inlet septa<br />

and pre-cleaned O-rings makes maintenance quicker and<br />

easier—no unscheduled inlet maintenance due to residue<br />

on the inlet surface, shorter bakeout times after preventive<br />

maintenance, so you can start running samples sooner.<br />

<strong>Agilent</strong> Services keep your lab running<br />

at peak productivity<br />

With a 98% customer satisfaction rating, <strong>Agilent</strong>’s service<br />

engineers are the most respected-and best-trained-in the<br />

industry. Whether you need support <strong>for</strong> a single instrument<br />

or a multi-lab, multi-vendor operation, we can help you solve<br />

problems quickly, increase your uptime, and optimize your<br />

lab’s resources. Through a selection of service plans tailored<br />

to your lab’s needs and budget, we provide:<br />

• On-site preventive maintenance that ensures dependable<br />

system operation and minimizes unplanned downtime<br />

For more in<strong>for</strong>mation<br />

Learn more:<br />

www.agilent.com/chem/<strong>7000A</strong><br />

Buy online:<br />

www.agilent.com/chem/store<br />

Find an <strong>Agilent</strong> customer center in your country:<br />

www.agilent.com/chem/contactus<br />

U.S. and Canada<br />

1-800-227-9770<br />

agilent_inquiries@agilent.com<br />

Europe<br />

info_agilent@agilent.com<br />

Asia Pacific<br />

adinquiry_aplsca@agilent.com<br />

<strong>Research</strong> use only. In<strong>for</strong>mation, descriptions, and specifications in this publication are<br />

subject to change without notice. <strong>Agilent</strong> Technologies shall not be liable <strong>for</strong> errors<br />

contained herein or <strong>for</strong> incidental or consequential damages in connection with the<br />

furnishing, per<strong>for</strong>mance, or use of this material.<br />

© <strong>Agilent</strong> Technologies, Inc. 2008<br />

Printed in USA October 3, 2008<br />

5990-3152EN<br />

• Available remote diagnostic and monitoring capabilities that<br />

give you additional “uptime insurance”<br />

• Expert installation, familiarization and advanced training to<br />

get you up and running as quickly as possible, and to make<br />

sure you get the most from your new <strong>Agilent</strong> equipment

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!