Room Air Conditioner SVC MANUAL(Exploded ... - Jordans Manuals
Room Air Conditioner SVC MANUAL(Exploded ... - Jordans Manuals
Room Air Conditioner SVC MANUAL(Exploded ... - Jordans Manuals
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Functions<br />
Functions<br />
Indoor Unit<br />
Cooling Mode Operation<br />
Healthy dehumidification Mode Operation<br />
Heating Mode Operation<br />
Jet Cool Mode Operation<br />
Jet Heat Mode Operation (Optional)<br />
Operation ON/OFF by Remote controller<br />
Sensing the <strong>Room</strong> Temperature<br />
• <strong>Room</strong> temperature sensor. (Thermistor)<br />
• Pipe temperature sensor. (Thermistor)<br />
<strong>Room</strong> Temperature Control<br />
• Maintain the room temperature in accordance with the Setting Temp.<br />
Starting the Current Control<br />
• Indoor fan is delayed for 5 sec at the starting.<br />
Time Delay Safety Control<br />
• Restarting is for approx. 3 minutes.<br />
Indoor Fan Speed Control<br />
• Super High, High, Med, Low<br />
Operation indication Lamps (LED)<br />
On/Off : Lights up during the system operation.<br />
Timer or : Lights up during Timer operation or<br />
Sleep Mode Sleep mode.<br />
Defrost Mode : Lights up during Defrost Mode or Hot<br />
Start operation. (Heat pump model only)<br />
Outdoor unit : Lights up during outdoor unit operation.<br />
operation (Cooling model only)<br />
Plasma Mode : Lights up during plasma-purification<br />
operation.(option)<br />
Auto Restart Mode : Lights up during if Restart Button<br />
is pressed.<br />
Auto Restart Button : In failure of electric power, if the<br />
button is pressed the unit runs as<br />
previous setting operation when<br />
power returns.<br />
Forced Operation Button : Operation starts, when this button<br />
is pressed and stops when you<br />
press the button again.<br />
Copyright ©2008 LG Electronics. Inc. All right reserved.<br />
Only for training and service purposes<br />
- 30 -<br />
LGE Internal Use Only