Industrial<br />
Automation<br />
Associated Data Carrier<br />
Housing Fig. Part Number ID Number Read/Write Range Zone Width Distance<br />
Length<br />
minimum<br />
between two<br />
read/write<br />
heads 1<br />
Recomm.<br />
inches<br />
(mm)<br />
min.<br />
inches<br />
(mm)<br />
max.<br />
inches<br />
(mm)<br />
min.<br />
inches<br />
(mm)<br />
max.<br />
inches<br />
(mm)<br />
inches<br />
(mm)<br />
1<br />
1 TW-R16-B128 M6900501 1.220<br />
(31)<br />
.630<br />
(16)<br />
2.480<br />
(63)<br />
2.835<br />
(72)<br />
3.543<br />
(90)<br />
14.173<br />
(360)<br />
2<br />
2 TW-R20-B128 M6900502 1.417<br />
(36)<br />
.709<br />
(18)<br />
2.835<br />
(72)<br />
3.228<br />
(82)<br />
4.055<br />
(103)<br />
16.220<br />
(412)<br />
3<br />
3 TW-R30-B128 M6900503 1.772<br />
(45)<br />
.866<br />
(22)<br />
3.543<br />
(90)<br />
3.661<br />
(93)<br />
4.606<br />
(117)<br />
18.425<br />
(468)<br />
4 TW-R50-B128 M6900504 2.835<br />
(72)<br />
1.417<br />
(36)<br />
5.669<br />
(144)<br />
4.803<br />
(122)<br />
6.024<br />
(153)<br />
24.094<br />
(612)<br />
4<br />
2 TW-R20-K2 M6900505 1.260<br />
(32)<br />
.630<br />
(16)<br />
2.520<br />
(64)<br />
2.913<br />
(74)<br />
3.701<br />
(94)<br />
14.803<br />
(376)<br />
3 TW-R30-K2 M6900506 1.575<br />
(40)<br />
.787<br />
(20)<br />
3.189<br />
(81)<br />
3.307<br />
(84)<br />
4.213<br />
(107)<br />
16.850<br />
(428)<br />
5<br />
4 TW-R50-K2 M6900507 2.520<br />
(64)<br />
1.181<br />
(30)<br />
5.079<br />
(129)<br />
4.370<br />
(111)<br />
5.433<br />
(138)<br />
21.732<br />
(552)<br />
5 TW-R50-90-HT-B128 M1542326 2.835<br />
(72)<br />
1.417<br />
(36)<br />
5.669<br />
(144)<br />
4.803<br />
(122)<br />
6.024<br />
(153)<br />
24.094<br />
(612)<br />
5 TW-R50-90-HT-K2 M1542329 2.520<br />
(64)<br />
1.181<br />
(30)<br />
5.079<br />
(129)<br />
4.370<br />
(111)<br />
5.394<br />
(137)<br />
21.732<br />
(552)<br />
1<br />
Smaller intervals are possible by alternating switching the read/write heads on and off with software.<br />
10 mm air gap required when mounting to ferrous metal. See accessories on page 26 for spacers.<br />
Ambient temperature: -25 to +85°C (-13 to +185°F); (-40 to +210°C (-40 to +410°F) for TW-R*-HT....).<br />