miniLAN-485 and miniLAN-232
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Ethernet converters serial lines<br />
<strong>miniLAN</strong>-<strong>485</strong> <strong>and</strong> <strong>miniLAN</strong>-<strong>232</strong><br />
<strong>miniLAN</strong>-<strong>485</strong><br />
<strong>miniLAN</strong>-<strong>232</strong><br />
▪ 1x ethernet port<br />
▪ <strong>miniLAN</strong>-<strong>485</strong> – 1x RS<strong>485</strong> port with support of:<br />
ASSET, ATS, CIAS, DOMINUS, GALAXY, HUB-PRO,<br />
ROGER, SATEL-ACCO, SICURIT-ABSOLUTE,<br />
STATION-ONE, Modbus RTU/ASCII<br />
▪ <strong>miniLAN</strong>-<strong>232</strong> – 2x RS<strong>232</strong> port with support of:<br />
▪ Overvoltage protection 30A<br />
▪ SNMP, TCP client/server<br />
▪ Local / remote management<br />
▪ Working temperature from –40°C to +70°C<br />
▪ Supply 12/24/48VDC<br />
or 12/24VAC or PoE<br />
Modbus RTU/ASCII<br />
▪ Data response speed from 3ms ORDERING NAME CODE SUPPLY<br />
<strong>miniLAN</strong>-<strong>485</strong> 2-104-572 10-60VDC/10-30VAC/PoE<br />
<strong>miniLAN</strong>-<strong>232</strong> 2-105-572 10-60VDC/10-30VAC/PoE<br />
* holder DIN35-LOCK for mounting to DIN35 included<br />
RS<strong>485</strong> over LAN<br />
RS<strong>485</strong> 5VDC<br />
<strong>miniLAN</strong>-<strong>485</strong><br />
RS<strong>485</strong> 5VDC<br />
<strong>miniLAN</strong>-<strong>485</strong><br />
LAN<br />
RS<strong>485</strong><br />
RS422<br />
2x DI<br />
LAN-<strong>485</strong><br />
2x RELAY<br />
OUT<br />
switch<br />
RS<strong>485</strong> over LAN-RING<br />
switch<br />
LAN-RING<br />
switch<br />
RS<strong>485</strong><br />
<strong>miniLAN</strong>-<strong>485</strong><br />
switch<br />
5VDC<br />
<strong>miniLAN</strong>-<strong>485</strong><br />
<strong>miniLAN</strong>-<strong>485</strong><br />
RS<strong>485</strong><br />
5VDC<br />
LEGEND<br />
1x MM or SM fiber<br />
Fast Ethernet<br />
RS<strong>485</strong><br />
5VDC<br />
Gigabit Ethernet<br />
others<br />
www.metel.eu 1/7
Installation manual REV:20130122<br />
<strong>miniLAN</strong>-<strong>485</strong> <strong>and</strong> <strong>miniLAN</strong>-<strong>232</strong><br />
Ethernet converters serial lines<br />
RS<strong>232</strong> over LAN<br />
RS<strong>232</strong> over LAN-RING<br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
<strong>miniLAN</strong>-<strong>232</strong><br />
<strong>miniLAN</strong>-<strong>232</strong><br />
switch<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
LAN<br />
switch<br />
LAN-RING<br />
switch<br />
switch<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
LEGEND<br />
1x MM or SM fiber<br />
Fast Ethernet<br />
Gigabit Ethernet<br />
others<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
Description <strong>and</strong> technical parameters<br />
MiniLAN-<strong>485</strong> <strong>and</strong> <strong>miniLAN</strong>-<strong>232</strong> are industrial modules for transmission of RS<strong>485</strong> or RS<strong>232</strong> bus with the option of supplying over<br />
Ethernet (PoE).<br />
Parameter Value Unit Note<br />
Management Local with HW protection USB – SIMUL<strong>and</strong> Windows application<br />
Remote Ethernet – SIMUL<strong>and</strong> Windows application<br />
RS ports Data speed 1.2 – 57.6 Kbps half / full duplex (UTP cat.5)<br />
<strong>miniLAN</strong>-<strong>485</strong><br />
<strong>miniLAN</strong>-<strong>232</strong><br />
1x half duplex RS<strong>485</strong><br />
2x full duplex RS<strong>232</strong> Rx/Tx<br />
Power Supply Voltage 10-60VDC or 10-30VAC or PoE<br />
Power consumption Max. 1 VA<br />
Environment Operational range –40...+70 ºC temp. of environment<br />
Humidity Max. 95 (non-condensing) %<br />
Mechanical Dimensions - w / h / l 52 x 32 x 82 mm<br />
Parameters Weight 0.16 kg<br />
Certification<br />
TÜV<br />
The producer retains the right to change any technical parameters without previous announcement.<br />
www.metel.eu 2/7
Installation manual REV:20130122<br />
<strong>miniLAN</strong>-<strong>485</strong> <strong>and</strong> <strong>miniLAN</strong>-<strong>232</strong><br />
Ethernet converters serial lines<br />
Example connection with access control system<br />
FE<br />
RS<strong>485</strong><br />
FE<br />
<strong>miniLAN</strong>-<strong>485</strong><br />
<strong>miniLAN</strong>-<strong>485</strong><br />
FE<br />
LAN<br />
FE<br />
RS<strong>485</strong><br />
<strong>miniLAN</strong>-<strong>485</strong><br />
RS<strong>485</strong><br />
FE<br />
RS<strong>485</strong><br />
<strong>miniLAN</strong>-<strong>485</strong><br />
Example connection with perimeter security system<br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
FE<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
FE<br />
LAN<br />
FE<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
FE<br />
FE<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
RS<strong>232</strong>/1<br />
RS<strong>232</strong>/2<br />
www.metel.eu 3/7
Installation manual REV:20130122<br />
<strong>miniLAN</strong>-<strong>485</strong> <strong>and</strong> <strong>miniLAN</strong>-<strong>232</strong><br />
Ethernet converters serial lines<br />
Example of communication over UDP for GALAXY system in SIMUL<strong>and</strong> application<br />
Rx 239.192.168.1<br />
Tx 239.192.168.1<br />
LAN-RING*<br />
Rx 239.192.168.1<br />
Tx 239.192.168.1<br />
Rx 239.192.168.1<br />
Tx 239.192.168.1<br />
Rx 239.192.168.1<br />
Tx 239.192.168.1<br />
LEGEND<br />
Fast Ethernet<br />
RS<strong>485</strong><br />
* When interconnecting the RS<strong>485</strong> buses of alarm<br />
systems we recommend using only our <strong>miniLAN</strong> <strong>and</strong><br />
LAN-RING devices optimized for low delays of RS<strong>485</strong><br />
transmission. See www.metel.eu for an up-to-date list<br />
of compatible systems that have been tested with our<br />
devices.<br />
Default device IP<br />
address is<br />
provided on the<br />
label<br />
Transmission<br />
mode – select<br />
GALAXY<br />
NOTE: If you can not connect to the device check the IP address of the network adapter in your computer; it must be set in the<br />
range of the device IP address.<br />
E.g.: device IP address: 10.0.0.1 PC IP address: 10.0.0.2-254<br />
mask: 255.0.0.0 mask: 255.0.0.0<br />
Setting of RS<strong>485</strong> transmission in UDP mode (multicast)<br />
The setting is very simple <strong>and</strong> consists of the following steps:<br />
1. In menu „Bus/Mode“ set the system you are using. If not provided select “RS<strong>485</strong>”. If the system is provided in the menu<br />
no further setting in menu „Bus“ is needed. The converter sets it automatically.<br />
2. In menu „Ethernet“ set receiving <strong>and</strong> transmitting addresses in range 239.0.0.0 - 239.255.255.255 (multicast).<br />
topology BUS – set the same receiving <strong>and</strong> transmitting address on all converters.<br />
topology POINT-to-POINT – set the addresses “crosswise”:<br />
Example: Device 1 receiving address - 239.192.168.2, transmitting address 1 - 239.192.168.3<br />
Device 2receiving address - 239.192.168.3, transmitting address 1 - 239.192.168.2<br />
www.metel.eu 4/7
Installation manual REV:20130122<br />
<strong>miniLAN</strong>-<strong>485</strong> <strong>and</strong> <strong>miniLAN</strong>-<strong>232</strong><br />
Ethernet converters serial lines<br />
Example of communication over TCP for GALAXY system in SIMUL<strong>and</strong> application<br />
Transmission<br />
mode – select<br />
GALAXY<br />
TCP client<br />
IP:10.0.0.20<br />
TCP server<br />
IP:10.0.0.10<br />
Setting of RS<strong>485</strong> transmission in TCP mode<br />
The setting consists of the following steps:<br />
1. It is necessary to decide which device will be server <strong>and</strong> which client. The clients must always perform the first request to the<br />
server <strong>and</strong> thus start up a TCP connection.<br />
2. In menu „Bus/Mode“ set the system you are using. If not provided select “RS<strong>485</strong>”. If the system is provided in the menu<br />
no further setting in menu „Bus“ is needed. The converter sets it automatically.<br />
3. Converter in mode TCP server - in menu „Ethernet/local port“ set the number of port that will be used by a TCP client to<br />
establish connection.<br />
4. Converter in mode TCP client - in menu „Ethernet/TCP client - remote port a TCP client – remote IP“ set the number of port<br />
<strong>and</strong> IP address of a remote TCP server.<br />
<strong>miniLAN</strong>-<strong>485</strong> in TCP server mode<br />
Port that will be<br />
used for TCP<br />
communication<br />
<strong>miniLAN</strong>-<strong>485</strong> in TCP client mode (connection start-up)<br />
Port that is set on TCP<br />
server <strong>and</strong> its IP address<br />
www.metel.eu 5/7
Installation manual REV:20130122<br />
<strong>miniLAN</strong>-<strong>485</strong> <strong>and</strong> <strong>miniLAN</strong>-<strong>232</strong><br />
Ethernet converters serial lines<br />
Example of communication over TCP for PERIDECT system in SIMUL<strong>and</strong> application<br />
IP: 10.130.0.1<br />
Port: 10 <strong>232</strong><br />
LAN<br />
Port: 10 233<br />
TCP client<br />
IP: 10.130.0.2<br />
Port: 10 <strong>232</strong><br />
Port: 10 233<br />
LEGEND<br />
Fast Ethernet<br />
RS<strong>232</strong><br />
Setting of <strong>miniLAN</strong>-<strong>232</strong> (mode TCP server)<br />
The setting consists of the following steps:<br />
1. In menu „Bus/Mode“ set mode „Peridect <strong>232</strong>“ for systems connected to Peridect or „RS<strong>232</strong>“ for connection of other devices<br />
communicating with this bus.<br />
2. In menu „ETH/ETH1/local port“ <strong>and</strong> „ETH/ETH2/local port“ set numbers of TCP ports that will be used by a TCP client to<br />
establish communication.<br />
3. Configure the TCP client in a PC with installed application (e.g. integration software).<br />
IP address of<br />
TCP server<br />
Mode for<br />
PERIDECT<br />
The port on<br />
which the<br />
TCP client<br />
establishes<br />
connection<br />
www.metel.eu 6/7
Installation manual REV:20130122<br />
<strong>miniLAN</strong>-<strong>485</strong> <strong>and</strong> <strong>miniLAN</strong>-<strong>232</strong><br />
Ethernet converters serial lines<br />
<strong>miniLAN</strong>-<strong>485</strong><br />
RS<strong>485</strong><br />
5VDC<br />
PWR<br />
DATA<br />
A+<br />
RS<strong>485</strong><br />
B-<br />
GND<br />
5VDC OUT<br />
<strong>miniLAN</strong>-<strong>485</strong><br />
CODE: 2-104-572<br />
10-30VAC/<br />
10-60VDC<br />
LAN + PoE<br />
10-30VAC<br />
10-60VDC<br />
LAN + PoE<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
2x RS<strong>232</strong><br />
PWR<br />
DATA - 1<br />
TXD 1<br />
RXD 1<br />
GND<br />
TXD 2<br />
<strong>miniLAN</strong>-<strong>232</strong><br />
CODE: 2-105-572<br />
10-30VAC/<br />
10-60VDC<br />
LAN + PoE<br />
10-30VAC<br />
10-60VDC<br />
LAN + PoE<br />
RXD 2<br />
DATA - 2<br />
<strong>miniLAN</strong>-… Dimensions<br />
70.00<br />
30.00<br />
51.50<br />
www.metel.eu 7/7