• If the joint is too<br />

long, it is evident<br />

that the first bolt<br />

will carry more<br />

than the medium<br />

bolt. It is preferred<br />

that no more than<br />

6 bolts should be<br />

arranged in a single<br />

gauge otherwise a<br />

r<strong>edu</strong>ction in the<br />

resistance of the<br />

bolts is expected as<br />

the load<br />

distribution on<br />

each bolt will be<br />

non‐uniform<br />

Limiting max. no. of bolts in a<br />

connection