3. Install the sectional reflector<br />
Reflectors<br />
The efficiency of the panel is increased by fitting reflectors so that the sunlight<br />
falling between the tubes is not wasted. The reflector is supplied as a set of 19<br />
pressed stainless forms which are clamped between each tube using special<br />
plastic clips. The diagrams below demonstrate how the reflectors are assembled:<br />
• Put one section of reflector between two vacuum tubes.<br />
• Insert the Special fixings (Plastic clips) into the hole at one end of the<br />
reflector and rotate 90°. Now one end of the reflector is fixed between two<br />
vacuum tubes.<br />
• Similarly, secure the other end of the reflector.<br />
• Repeat for the remaining 18 sections of reflector as described above.<br />
The sketch below shows a cutaway view of reflector installation.<br />
Special fixing<br />
Vacuum tube<br />
Vacuum tube<br />
Sectional reflector<br />
Navitron Ltd.<br />
www.navitron.org.uk<br />
The Drey, Old Dixton Rd, Monmouth, NP25 3SQ. Tel/Fax 0870 740 1330