01.09.2014 Views

DCRS Product Brochure: Data Center Racking System

DCRS Product Brochure: Data Center Racking System

DCRS Product Brochure: Data Center Racking System

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Deploy More IT with CONFIDENCE <br />

and without HEAT issues<br />

Take the Intelligent Path<br />

Opengate <strong>Product</strong> <strong>Brochure</strong><br />

<strong>DCRS</strong><br />

RS <strong>Data</strong> <strong>Center</strong> Rack <strong>System</strong> Components<br />

Most data centers are not equipped to handle the racking, power, cabling, and cooling<br />

requirements for today’s various types of IT equipment. With Opengate <strong>DCRS</strong> you’ll have<br />

the confidence to deploy more IT while maintaining the IT intake air temperature to within<br />

a few degrees of the supply air temperature at all points in your data center.<br />

<strong>DCRS</strong> IT Enclosure<br />

<strong>DCRS</strong> Intelligent Solutions<br />

Rack Power<br />

WHY Choose Opengate?<br />

<strong>DCRS</strong> comprises a turnkeyspecified<br />

IT Enclosure with<br />

flexible pre-defined options<br />

for top panels, doors, locks,<br />

and cabling with intelligent<br />

power and cooling solution<br />

options.<br />

Equip your data center for<br />

future racking, power,<br />

cabling and cooling<br />

requirements.<br />

WHO Chose Opengate?<br />

Network Switch Cooling<br />

Top industry experts such<br />

as; Oracle, U.S. Army Corp<br />

of Engineers, and General<br />

Dynamics have selected<br />

Opengate to simplify data<br />

center cooling and<br />

maximize energy efficiency.<br />

Environment Monitoring<br />

Opengate systems allow<br />

rapid ROI—typically less<br />

than 3 months.<br />

Owners and operators are<br />

keeping costs low while<br />

delivering an effective and<br />

efficient facility.<br />

- <strong>DCRS</strong> has been optimized for cost optimization, quick customization<br />

with pre-defined options, cabling and thermal management -<br />

Opengate systems improve<br />

cash flow for IT operations<br />

by providing quick<br />

deployment, automation,<br />

and the greatest efficiency.<br />

PRODUCT SPECIFICATION<br />

<strong>DCRS</strong>7001A | AUGUST 2010<br />

www.opengatedata.com


<strong>DCRS</strong> Turnkey Design<br />

<strong>DCRS</strong> turnkey-specified<br />

Opengate <strong>DCRS</strong>-2442 SHOWN<br />

IT enclosure has a base<br />

configuration with<br />

orderable pre-defined<br />

options for top panels,<br />

doors, locks, power,<br />

cabling and cooling.<br />

<strong>DCRS</strong> has been optimized<br />

through our work with<br />

Oracle for quick<br />

customization with<br />

turnkey options.<br />

<strong>DCRS</strong> FRAME<br />

<strong>DCRS</strong> COMPLETE<br />

<strong>DCRS</strong> 45U – BASE ENCLOSURE SPECIFICATIONS*<br />

45 EIA rack units with 2000 pound total dynamic load capacity<br />

16 GA welded frame construction w/ 12 GA caster support channels<br />

EIA 310D 12 GA square hole rails silk screened RU space front and rear.<br />

Ships with rear rails set 28.50 from front rails.<br />

16 GA vertical lacing at rear corners w/ provision for tool-less PDU mounting<br />

18 GA side panels, removable, fastened from outside with recessed hardware<br />

Front frame-to-floor air block skirt (end of row air block skirt specified separate)<br />

700 lb capacity each swivel casters, without locks<br />

Four leveling legs<br />

Color black<br />

Enclosures shipped without skids, covered with a plastic bag with four (4) vertical corner<br />

protectors, four (4) top protective corners and shrink wrapped<br />

<strong>DCRS</strong> DOOR OPTIONS: SOLID OR<br />

PERFORATED, SPLIT OR FULL WIDTH<br />

*Front doors, top panels, door locks, and rack<br />

ganging provisions are specified separately.<br />

42 EIA rack unit versions available.<br />

www.opengatedata.com


Deploy More IT with CONFIDENCE <br />

and without HEAT issues<br />

Take the Intelligent Path<br />

<strong>DCRS</strong><br />

RS Base Enclosure Options<br />

<strong>DCRS</strong> 45U Models<br />

<strong>DCRS</strong>-2442 shown<br />

<strong>DCRS</strong>42U 42 EIA rack unit versions available<br />

<strong>DCRS</strong> 24 Wide x 42 Deep<br />

<strong>DCRS</strong>-2442S Split Rear Door<br />

<strong>DCRS</strong>-2442F Full Rear Door<br />

<strong>DCRS</strong> 30 Wide X 42 Deep<br />

<strong>DCRS</strong>-3042S Split Rear Door<br />

<strong>DCRS</strong>-3042F Full Rear Door<br />

<strong>DCRS</strong> 24 Wide X 48 Deep<br />

<strong>DCRS</strong>-2448S Split Rear Door<br />

<strong>DCRS</strong>-2448F Full Rear Door<br />

<strong>DCRS</strong> 30 Wide X 48 Deep<br />

<strong>DCRS</strong>-3048S Split Rear Door<br />

<strong>DCRS</strong>-3048F Full Rear Door<br />

Ultra-Efficient Containment<br />

Cooling Options<br />

Power/Cable Management<br />

Achieve 100% cooling utilization<br />

for zero waste cooling and the<br />

lowest PUE<br />

Raise supply air temp<br />

<strong>DCRS</strong> Blank Panels<br />

BP1U<br />

BP2U<br />

BP3U<br />

BP1U/2U/3U Tool-less Blank Panels<br />

Available in 10 Packs<br />

Raise entering water temp<br />

Maximize free cooling hours<br />

Deploy more IT racks without<br />

heat issues and intelligently<br />

manage data center growth<br />

Full data center loading is<br />

achieved using Opengate<br />

Containment Cooling<br />

Contact an Opengate<br />

integration partner for more<br />

information.<br />

PRODUCT SPECIFICATION<br />

<strong>DCRS</strong>7001A | AUGUST 2010


<strong>DCRS</strong><br />

RS with<br />

with Pre-Configured Options and Accessories<br />

<strong>DCRS</strong> 45U<br />

Base Enclosure<br />

<strong>DCRS</strong> 45U Description<br />

Add Top Panel | Add Front Door<br />

<strong>DCRS</strong> 45U<br />

Pre-Configured Options<br />

<strong>DCRS</strong> 24 Wide x 42 Deep<br />

Add Top Panel<br />

<strong>DCRS</strong>-2442S<br />

24w X 42d Split Rear Door<br />

TP01<br />

Top Panel Solid<br />

<strong>DCRS</strong>-2442F<br />

24w X 42d Full Rear Door Right Hinge<br />

TP02<br />

Top Panel Brush Cable Entry<br />

<strong>DCRS</strong> 30 Wide X 42 Deep<br />

TP03<br />

Opengate EC Top No Brush<br />

<strong>DCRS</strong>-3042S<br />

30w X 42d Split Rear Door<br />

TP04<br />

Opengate EC Top With Brush<br />

<strong>DCRS</strong>-3042F<br />

30w X 42d Full Rear Door Right Hinge<br />

Add Front Door<br />

<strong>DCRS</strong> 24 Wide X 48 Deep<br />

FD01<br />

Front Door Perforated<br />

<strong>DCRS</strong>-2448S<br />

24w X 48d Split Rear Door<br />

Change Perforated Rear Door Option<br />

<strong>DCRS</strong>-2448F<br />

24w X 48d Full Rear Door Right Hinge<br />

PR<br />

Perforated Rear Door Option<br />

<strong>DCRS</strong> 30 Wide X 48 Deep<br />

Add Door Lock Core Option<br />

<strong>DCRS</strong>-3048S<br />

30w X 48d Split Rear Door<br />

HL01<br />

Door Lock Core Same Key<br />

<strong>DCRS</strong>-3048F<br />

30w X 48d Full Rear Door Right Hinge<br />

HL02<br />

Door Lock Core Custom Keyed<br />

Rack rear doors are solid as standard to support rack heat containment airflow standards. Perforated rear<br />

doors must be specified with a PR suffix. Example: <strong>DCRS</strong>-2442S-PR 24wx 42d Split Perforated Rear Door<br />

<strong>DCRS</strong> 45U<br />

Pre-Configured Options (cont)<br />

<strong>DCRS</strong><br />

Accessory Options<br />

Add End of Row Side Rack to Floor Skirt (2/row)<br />

<strong>DCRS</strong> Tool-less Steel Blank Panels<br />

ERS42<br />

End of Row Side Skirt 42d<br />

BP1U<br />

1U BP Package Qty 10 Panels<br />

ERS48<br />

End of Row Side Skirt 48d<br />

BP2U<br />

2U BP Package Qty 10 Panels<br />

Rack Gang Hardware Kit<br />

RG01<br />

Rack Joining for 2 Racks<br />

BP3U<br />

3U BP Package Qty 10 Panels<br />

IT Equipment Mounting Hardware Kit<br />

HK01<br />

100 Pieces M6 Cage Nuts/Screws<br />

Cable Straps<br />

VS18<br />

CT18<br />

Velcro Strap ½” W x 18” L<br />

Plastic Cable Tie 18” L UV Stable<br />

www.opengatedata.com


Deploy More IT with CONFIDENCE <br />

and without HEAT issues<br />

Take the Intelligent Path<br />

<strong>DCRS</strong><br />

SiteXep<br />

ep<br />

RS Intelligent Solutions<br />

ep Enterprise Rack Power to 34 kW<br />

Intelligent Rack Power Distribution<br />

Effective rack power distribution with true RMS remote metering for<br />

up to 34 kW per rack power bar. Fully integrate rack power load,<br />

cooling load and environment monitoring in one network connection.<br />

SiteX EP Features<br />

Input Cord Length Adjust Option<br />

Multiple Receptacle Type Option<br />

Name: Rack C145 Load [%]: 37 <strong>System</strong><br />

Guarded Breakers<br />

Standard<br />

IEC60309 Plug<br />

Option<br />

SiteX EP Rack Power Models<br />

SiteX EP Rack Power Bar Series<br />

RP900 local plus remote meter and L21-30 Input Plug<br />

RP900 with [24] C13, [3] C19 and [6] 5-20 Receptacles<br />

RP2300 with [12] C19 Receptacles<br />

RP2300 with Hardwire Input<br />

RP Rack Mount Versions Available<br />

RP500<br />

208VAC 30Amps 5 kW<br />

L6-30P C13/C19 Options<br />

RP600<br />

208VAC 3PH 20Amps 5.7 kW<br />

L21-20P 5-20/C13/C19 options<br />

RP900<br />

208VAC 3PH 30Amps 8.6 kW<br />

L21-30P 5-20/C13/C19 options<br />

RP1700<br />

208VAC 3PH 60Amps 17.2 kW<br />

Hardwire 5-20/C13/C19 options<br />

RP2300<br />

208VAC 3PH 80Amps 23 kW<br />

Hardwire Input C19 Output<br />

RP3400<br />

208VAC 3PH 120Amps 34.4 kW<br />

Hardwire Input C19 Output


Deploy More IT with CONFIDENCE <br />

and without HEAT issues<br />

Take the Intelligent Path<br />

SA2 Specification<br />

Item Number<br />

SA2-001<br />

Rack Mounting<br />

26-5/8” to 29-5/8 Rail Depth<br />

Input Power<br />

90-264 VAC 50/60 Hz<br />

15 watts<br />

Input Connector<br />

C14 Input<br />

Input Cord<br />

Order separately<br />

Airflow<br />

48 CFM<br />

Safety / Approvals<br />

UL/cUL 60950, FCC<br />

Warranty<br />

2 Years<br />

SwitchAir<br />

2U<br />

2U Network Switch Cooling ®<br />

Effective cool air delivery for multiple rear rack mounted 1U switches<br />

Universal for rear intake or side intake switch types<br />

Switch Temp<br />

70 ºC<br />

60 ºC<br />

50 ºC<br />

Before<br />

SwitchAir INSTALLED<br />

After<br />

Actual Cisco 4948 before and after temp measurements<br />

SIDE CHANNEL<br />

AIR DELIVERY<br />

Three SwitchAir 2U Units<br />

Cooling up to Six Switches<br />

1<br />

2<br />

3<br />

Stack SwitchAir in consecutive u-spaces. Up to 6<br />

network switches cooled in this configuration<br />

NETWORK SWITCHES<br />

PATENT PENDING<br />

SwitchAir 2U can be installed while<br />

network switch is operational<br />

EM160 Attachable Sensors<br />

EM160 shown with EMS40<br />

Water Sensor and EMS40S<br />

Water Sensor Cable<br />

RACK FRONT<br />

SwitchAir INTAKE<br />

SwitchAir 1U model available for Cisco 4948 switch series<br />

SiteXem<br />

em<br />

em Environment Monitoring<br />

Intelligent rack or row environment monitoring with visibility to critical<br />

temperature, water, smoke and video information<br />

EM160 shown with EMS10<br />

Temperature Sensor and EMS15<br />

Temperature/Humidity Sensor<br />

EM Web & SNMP Software Logs Interface<br />

PRODUCT SPECIFICATION<br />

<strong>DCRS</strong>7001A | AUGUST 2010<br />

Web enabled cameras, door open and smoke sensors also available<br />

www.opengatedata.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!