Result<br />

3.2.1c<br />

Formaldehyde<br />

measurement<br />

between different<br />

types of buildings<br />

Higher Formaldehyde in<br />

most of the hotel areas<br />

• Technology Oriented • Business Driven • Sustainable Development • Environmental Friendly<br />

No Item Vent System Mean Median SD Min Max Stat<br />

1. Home <strong>Air</strong>-Condition - - - - - N/A<br />

No <strong>Air</strong>-Condition 0.03 0.02 0.05 0.0 0.41<br />

2. Office <strong>Air</strong>-Condition 0.05 0.01 0.20 0.00 3.32 0.849<br />

No <strong>Air</strong>-Condition 0.03 0.03 0.04 0.00 0.05<br />

3. Public <strong>Air</strong>-Condition 0.06 0.03 0.10 0.00 0.70 0.508<br />

No <strong>Air</strong>-Condition 0.08 0.03 0.16 0.00 0.48<br />

4. Mall <strong>Air</strong>-Condition 0.08 0.01 0.16 0 1.40 N/A<br />

No <strong>Air</strong>-Condition - - - - -<br />

5. Hotel <strong>Air</strong>-Condition 0.11 0.05 0.19 0.00 1.08 0.841<br />

No <strong>Air</strong>-Condition 0.09 0.10 0.02 0.07 0.10