44<br />
<strong>SUPERFLASH</strong> <strong>SYSTEM</strong> <strong>PARTS</strong><br />
18<br />
Stop End<br />
18mm Flashrail<br />
28<br />
Finrail and Finseal<br />
28mm Flashrail<br />
43<br />
Superslip<br />
43mm Flashrail<br />
88<br />
0.5mm 1.0mm 2.0mm<br />
Packing Cards<br />
Internal Corner Cover<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
BEVEL BACKED WEATHERBOARD<br />
Window Head on Cavity<br />
Scale 1:2<br />
Note: Allow 18mm (ideal) between<br />
head and framing for finrail / seal<br />
Timber bevel backed<br />
weatherboards<br />
Selected building<br />
underlay<br />
Cavity battens rebated<br />
at bottom end to allow<br />
for thickness of slip<br />
flashing with cavity<br />
closure<br />
Timber stud framing<br />
and insulation<br />
Flashtec Superslip<br />
flashing and cavity<br />
closer<br />
Layer of building<br />
underlay or tape over<br />
head flashing<br />
Head flashing stop end<br />
Window head flashing<br />
with 15° slope minimum<br />
35<br />
flashing upstand<br />
Selected internal<br />
lining<br />
Selected window<br />
architrave<br />
Sealant to window flashing<br />
5<br />
Rear seal in finrail<br />
10 mm cover<br />
Finrail<br />
Selected aluminium<br />
joinery<br />
18<br />
PVC internal corner<br />
cover placed under<br />
building underlay<br />
Flashtec click in<br />
jamb liner spacer<br />
Finseal<br />
1mm 'L' shaped<br />
packers as required<br />
Jamb liner. Use<br />
screws to secure<br />
joinery<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
BEVEL BACKED WEATHERBOARD<br />
Window Sill on Cavity<br />
Scale 1:2<br />
120x120x20mm<br />
PVC internal corner<br />
cover placed under<br />
building underlay<br />
Precut left and right<br />
aluminium stop end<br />
Window support blocks<br />
supplied with aluminium<br />
joinery<br />
25x35x6mm foam<br />
air seal block to<br />
both sides of sill<br />
9x9mm air seal<br />
fitted to inside edge<br />
of support bar<br />
Self tapping SS 6 gauge<br />
20mm long sq. dr. counter<br />
sunk screws<br />
12<br />
8mm cover min.<br />
Horizontal batten under<br />
window as required to<br />
suit profile<br />
Timber bevel backed<br />
weatherboards<br />
Surefast SS 8 gauge 20-<br />
25mm sq. dr. countersunk<br />
screws<br />
Selected window architrave<br />
Selected internal<br />
lining<br />
Selected building<br />
underlay<br />
Cavity battens rebated<br />
at top ends to allow for<br />
thickness of Supersill<br />
Timber stud framing<br />
and insulation<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
BEVEL BACKED WEATHERBOARD<br />
Window Jamb on Cavity<br />
Note: Allow 18mm (ideal) between<br />
Scale 1:2<br />
jamb and framing for finrail / seal<br />
20 mm head flashing<br />
extension<br />
Cavity batten<br />
Timber bevel backed<br />
weatherboards<br />
Weatherboard scriber<br />
sealed to weatherboards<br />
10 mm cover<br />
Timber stud framing and<br />
insulation<br />
Selected window architrave<br />
18<br />
Selected internal lining<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson<br />
Selected aluminium joinery<br />
Rear seal in finrail<br />
Finseal<br />
Finrail<br />
PVC internal corner cover<br />
placed under building underlay<br />
Flashtec click in jamb<br />
liner spacer<br />
1mm 'L' shaped packers<br />
as required<br />
Jamb liner. Use screws to<br />
secure joinery
BEVEL BACKED WEATHERBOARD<br />
Joinery Sill at Floor Level on Cavity<br />
Scale 1:2<br />
25x35x6mm foam<br />
air seal block to<br />
both sides of sill<br />
120x120x20mm PVC<br />
internal corner cover<br />
placed under building<br />
underlay<br />
Precut left and right<br />
aluminium stop end<br />
Window support<br />
blocks supplied with<br />
aluminium joinery<br />
9x9mm air seal<br />
fitted to inside edge<br />
of support bar<br />
Self tapping SS 6<br />
gauge 20mm long<br />
sq. dr. counter sunk<br />
screws<br />
Selected flooring<br />
8mm cover min.<br />
Horizontal batten<br />
under window as<br />
required to suit profile<br />
Timber bevel backed<br />
weatherboards<br />
Selected building<br />
underlay<br />
Surefast SS 8<br />
gauge 20-25mm sq.<br />
dr. countersunk<br />
screws<br />
Timber nogging<br />
between joists as<br />
required<br />
Cavity battens rebated<br />
at top ends to allow for<br />
thickness of Supersill<br />
Timber boundary joist<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
RUSTICATED WEATHERBOARD<br />
Joinery Sill at Floor Level on Cavity<br />
Scale 1:2<br />
25x35x6mm foam<br />
air seal block to<br />
both sides of sill<br />
120x120x20mm PVC<br />
internal corner cover<br />
placed under building<br />
underlay<br />
Precut left and right<br />
aluminium stop end<br />
Window support<br />
blocks supplied with<br />
aluminium joinery<br />
9x9mm air seal<br />
fitted to inside edge<br />
of support bar<br />
Self tapping SS 6<br />
gauge 20mm long<br />
sq. dr. counter<br />
sunk screws<br />
Selected flooring<br />
8mm cover min.<br />
Timber rusticated<br />
weatherboards or<br />
other 20mm cladding<br />
Selected building<br />
underlay<br />
Surefast SS 8<br />
gauge 20-25mm<br />
sq. dr. countersunk<br />
screws<br />
Timber nogging<br />
between joists as<br />
required<br />
Cavity battens rebated<br />
at top ends to allow for<br />
thickness of Supersill<br />
Timber boundary joist<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
SHEET CLADDING<br />
Joinery Head on Cavity<br />
Scale 1:2<br />
Note: Allow 18mm (ideal) between<br />
head and framing for finrail / seal<br />
Timber stud framing<br />
and insulation<br />
Cavity battens<br />
rebated at bottom<br />
end to allow for<br />
thickness of slip<br />
flashing with cavity<br />
closure<br />
Plywood or other<br />
sheet cladding up to<br />
12mm thick<br />
Selected building<br />
underlay<br />
Flashtec Superslip<br />
flashing and cavity<br />
closer<br />
Head flashing stop end<br />
Selected internal<br />
lining<br />
Window head flashing<br />
with 15° slope minimum<br />
Sealant to window<br />
flashing<br />
16<br />
35<br />
flashing upstand<br />
Selected window<br />
architrave<br />
Rear seal in finrail<br />
10 mm cover<br />
Finrail<br />
18<br />
PVC internal corner<br />
cover placed under<br />
building underlay<br />
Selected aluminium<br />
joinery<br />
Finseal<br />
Flashtec click in jamb<br />
liner spacer<br />
1mm 'L' shaped<br />
packers as required<br />
Jamb liner. Use screws<br />
to secure joinery<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
SHEET CLADDING<br />
Joinery Sill on Cavity<br />
Scale 1:2<br />
120x120x20mm PVC<br />
internal corner cover<br />
placed under<br />
building underlay<br />
Precut left and right<br />
aluminium stop end<br />
Window support blocks<br />
supplied with aluminium<br />
joinery<br />
12<br />
25x35x6mm foam<br />
air seal block to<br />
both sides of sill<br />
9x9mm air seal<br />
fitted to inside edge<br />
of support bar<br />
Self tapping SS 6 gauge<br />
20mm long sq. dr.<br />
counter sunk screws<br />
8mm cover min.<br />
Plywood or other sheet<br />
cladding up to 12mm<br />
thick<br />
Selected building<br />
underlay<br />
Cavity battens rebated<br />
at top ends to allow for<br />
thickness of Supersill<br />
Timber stud framing<br />
and insulation<br />
Surefast SS 8 gauge 20-<br />
25mm sq. dr.<br />
countersunk screws<br />
Selected window architrave<br />
Selected internal<br />
lining<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
SHEET CLADDING<br />
Joinery Jamb on Cavity<br />
Scale 1:2<br />
Cavity battens<br />
Plywood or other sheet<br />
cladding up to 12mm<br />
thick<br />
Timber stud framing and<br />
insulation<br />
Selected internal lining Selected window architrave<br />
18<br />
Note: Allow 18mm (ideal) between<br />
jamb and framing for finrail / seal<br />
10 mm cover<br />
Continuous protective sealant<br />
Foam bond breaker<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson<br />
20 mm head flashing<br />
extension<br />
Selected aluminium joinery<br />
Rear seal in finrail<br />
Finseal<br />
Finrail<br />
PVC internal corner cover<br />
placed under building underlay<br />
Flashtec click in jamb liner<br />
spacer<br />
1mm 'L' shaped packers<br />
as required<br />
Jamb liner. Use screws to<br />
secure joinery
BRICK VENEER<br />
Joinery Head<br />
Scale 1:2<br />
Note: Allow 18mm (ideal) between<br />
head and framing for finrail / seal<br />
Selected building<br />
underlay<br />
Timber stud<br />
framing and<br />
insulation<br />
Selected brick<br />
veneer<br />
Head flashing<br />
turned into angle or<br />
flat steel lintel.<br />
Extend flashing<br />
200mm each side<br />
of opening<br />
Drainage holes in<br />
veneer<br />
Steel lintel<br />
flashing upstand<br />
Selected internal<br />
lining<br />
Selected window<br />
architrave<br />
Rear seal in finrail<br />
18<br />
Sealant<br />
Finrail<br />
Selected<br />
aluminium<br />
joinery<br />
Finseal<br />
PVC internal corner<br />
cover placed under<br />
building underlay<br />
Flashtec click in<br />
jamb liner spacer<br />
1mm 'L' shaped<br />
packers as<br />
required<br />
Jamb liner. Use<br />
screws to secure<br />
joinery<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
BRICK VENEER<br />
Joinery Sill<br />
Scale 1:2<br />
120x120x20mm PVC<br />
internal corner cover<br />
placed under building<br />
underlay<br />
Precut left and right<br />
aluminium stop end<br />
Window support blocks<br />
supplied with aluminium<br />
joinery<br />
25x35x6mm foam<br />
air seal block to<br />
both sides of sill<br />
9x9mm air seal<br />
fitted to inside edge<br />
of support bar<br />
Joinery sill, do not seal<br />
to brick sill<br />
12<br />
Self tapping SS 6 gauge<br />
20mm long sq. dr.<br />
counter sunk screws<br />
Brick sill cantilevered or<br />
flush with min 15º slope<br />
Surefast SS 8 gauge 20-<br />
25mm sq. dr.<br />
countersunk screws<br />
Selected window architrave<br />
Selected internal lining<br />
Selected<br />
building<br />
underlay<br />
Timber stud<br />
framing and<br />
insulation<br />
Sill flashing with drip<br />
edge, extend 200mm<br />
each side of window<br />
H3.2 timber kick-out fillet<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson
BRICK VENEER<br />
Joinery Jamb<br />
Scale 1:2<br />
Timber stud framing<br />
and insulation<br />
Selected window architrave<br />
Selected internal lining<br />
18<br />
Note: Allow 18mm (ideal) between<br />
jamb and framing for finrail / seal<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson<br />
Brick veneer<br />
Line of masonry wall tie<br />
Selected aluminium joinery<br />
Rear seal in finrail<br />
Finseal<br />
Finrail<br />
PVC internal corner cover<br />
placed under building underlay<br />
Flashtec click in jamb<br />
liner spacer<br />
1mm 'L' shaped packers<br />
as required<br />
Jamb liner. Use screws to<br />
secure joinery
BRICK VENEER<br />
Joinery Sill with Rebate<br />
Scale 1:2<br />
120x120x20mm PVC<br />
internal corner cover<br />
placed under building<br />
underlay<br />
Precut left and right<br />
aluminium stop end<br />
Window support blocks<br />
supplied with aluminium<br />
joinery<br />
Joinery sill, do not seal<br />
to brick sill<br />
33<br />
25x35x6mm foam<br />
air seal block to<br />
both sides of sill<br />
9x9mm air seal<br />
fitted to inside edge<br />
of support bar<br />
Self tapping SS 6 gauge<br />
20mm long sq. dr. counter<br />
sunk screws<br />
Brick sill cantilevered or<br />
flush with min 15º slope<br />
Surefast SS 8 gauge 20-<br />
25mm sq. dr. countersunk<br />
screws in tappet to suit<br />
DPC between flashrail<br />
and concrete<br />
FLASHTEC PRODUCTS LTD<br />
09 836 6366<br />
www.flashtec.co.nz<br />
10A Clemway Place, Henderson