17.10.2014 Views

SUPERFLASH SYSTEM PARTS - Ullrich Aluminium

SUPERFLASH SYSTEM PARTS - Ullrich Aluminium

SUPERFLASH SYSTEM PARTS - Ullrich Aluminium

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

44<br />

<strong>SUPERFLASH</strong> <strong>SYSTEM</strong> <strong>PARTS</strong><br />

18<br />

Stop End<br />

18mm Flashrail<br />

28<br />

Finrail and Finseal<br />

28mm Flashrail<br />

43<br />

Superslip<br />

43mm Flashrail<br />

88<br />

0.5mm 1.0mm 2.0mm<br />

Packing Cards<br />

Internal Corner Cover<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


BEVEL BACKED WEATHERBOARD<br />

Window Head on Cavity<br />

Scale 1:2<br />

Note: Allow 18mm (ideal) between<br />

head and framing for finrail / seal<br />

Timber bevel backed<br />

weatherboards<br />

Selected building<br />

underlay<br />

Cavity battens rebated<br />

at bottom end to allow<br />

for thickness of slip<br />

flashing with cavity<br />

closure<br />

Timber stud framing<br />

and insulation<br />

Flashtec Superslip<br />

flashing and cavity<br />

closer<br />

Layer of building<br />

underlay or tape over<br />

head flashing<br />

Head flashing stop end<br />

Window head flashing<br />

with 15° slope minimum<br />

35<br />

flashing upstand<br />

Selected internal<br />

lining<br />

Selected window<br />

architrave<br />

Sealant to window flashing<br />

5<br />

Rear seal in finrail<br />

10 mm cover<br />

Finrail<br />

Selected aluminium<br />

joinery<br />

18<br />

PVC internal corner<br />

cover placed under<br />

building underlay<br />

Flashtec click in<br />

jamb liner spacer<br />

Finseal<br />

1mm 'L' shaped<br />

packers as required<br />

Jamb liner. Use<br />

screws to secure<br />

joinery<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


BEVEL BACKED WEATHERBOARD<br />

Window Sill on Cavity<br />

Scale 1:2<br />

120x120x20mm<br />

PVC internal corner<br />

cover placed under<br />

building underlay<br />

Precut left and right<br />

aluminium stop end<br />

Window support blocks<br />

supplied with aluminium<br />

joinery<br />

25x35x6mm foam<br />

air seal block to<br />

both sides of sill<br />

9x9mm air seal<br />

fitted to inside edge<br />

of support bar<br />

Self tapping SS 6 gauge<br />

20mm long sq. dr. counter<br />

sunk screws<br />

12<br />

8mm cover min.<br />

Horizontal batten under<br />

window as required to<br />

suit profile<br />

Timber bevel backed<br />

weatherboards<br />

Surefast SS 8 gauge 20-<br />

25mm sq. dr. countersunk<br />

screws<br />

Selected window architrave<br />

Selected internal<br />

lining<br />

Selected building<br />

underlay<br />

Cavity battens rebated<br />

at top ends to allow for<br />

thickness of Supersill<br />

Timber stud framing<br />

and insulation<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


BEVEL BACKED WEATHERBOARD<br />

Window Jamb on Cavity<br />

Note: Allow 18mm (ideal) between<br />

Scale 1:2<br />

jamb and framing for finrail / seal<br />

20 mm head flashing<br />

extension<br />

Cavity batten<br />

Timber bevel backed<br />

weatherboards<br />

Weatherboard scriber<br />

sealed to weatherboards<br />

10 mm cover<br />

Timber stud framing and<br />

insulation<br />

Selected window architrave<br />

18<br />

Selected internal lining<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson<br />

Selected aluminium joinery<br />

Rear seal in finrail<br />

Finseal<br />

Finrail<br />

PVC internal corner cover<br />

placed under building underlay<br />

Flashtec click in jamb<br />

liner spacer<br />

1mm 'L' shaped packers<br />

as required<br />

Jamb liner. Use screws to<br />

secure joinery


BEVEL BACKED WEATHERBOARD<br />

Joinery Sill at Floor Level on Cavity<br />

Scale 1:2<br />

25x35x6mm foam<br />

air seal block to<br />

both sides of sill<br />

120x120x20mm PVC<br />

internal corner cover<br />

placed under building<br />

underlay<br />

Precut left and right<br />

aluminium stop end<br />

Window support<br />

blocks supplied with<br />

aluminium joinery<br />

9x9mm air seal<br />

fitted to inside edge<br />

of support bar<br />

Self tapping SS 6<br />

gauge 20mm long<br />

sq. dr. counter sunk<br />

screws<br />

Selected flooring<br />

8mm cover min.<br />

Horizontal batten<br />

under window as<br />

required to suit profile<br />

Timber bevel backed<br />

weatherboards<br />

Selected building<br />

underlay<br />

Surefast SS 8<br />

gauge 20-25mm sq.<br />

dr. countersunk<br />

screws<br />

Timber nogging<br />

between joists as<br />

required<br />

Cavity battens rebated<br />

at top ends to allow for<br />

thickness of Supersill<br />

Timber boundary joist<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


RUSTICATED WEATHERBOARD<br />

Joinery Sill at Floor Level on Cavity<br />

Scale 1:2<br />

25x35x6mm foam<br />

air seal block to<br />

both sides of sill<br />

120x120x20mm PVC<br />

internal corner cover<br />

placed under building<br />

underlay<br />

Precut left and right<br />

aluminium stop end<br />

Window support<br />

blocks supplied with<br />

aluminium joinery<br />

9x9mm air seal<br />

fitted to inside edge<br />

of support bar<br />

Self tapping SS 6<br />

gauge 20mm long<br />

sq. dr. counter<br />

sunk screws<br />

Selected flooring<br />

8mm cover min.<br />

Timber rusticated<br />

weatherboards or<br />

other 20mm cladding<br />

Selected building<br />

underlay<br />

Surefast SS 8<br />

gauge 20-25mm<br />

sq. dr. countersunk<br />

screws<br />

Timber nogging<br />

between joists as<br />

required<br />

Cavity battens rebated<br />

at top ends to allow for<br />

thickness of Supersill<br />

Timber boundary joist<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


SHEET CLADDING<br />

Joinery Head on Cavity<br />

Scale 1:2<br />

Note: Allow 18mm (ideal) between<br />

head and framing for finrail / seal<br />

Timber stud framing<br />

and insulation<br />

Cavity battens<br />

rebated at bottom<br />

end to allow for<br />

thickness of slip<br />

flashing with cavity<br />

closure<br />

Plywood or other<br />

sheet cladding up to<br />

12mm thick<br />

Selected building<br />

underlay<br />

Flashtec Superslip<br />

flashing and cavity<br />

closer<br />

Head flashing stop end<br />

Selected internal<br />

lining<br />

Window head flashing<br />

with 15° slope minimum<br />

Sealant to window<br />

flashing<br />

16<br />

35<br />

flashing upstand<br />

Selected window<br />

architrave<br />

Rear seal in finrail<br />

10 mm cover<br />

Finrail<br />

18<br />

PVC internal corner<br />

cover placed under<br />

building underlay<br />

Selected aluminium<br />

joinery<br />

Finseal<br />

Flashtec click in jamb<br />

liner spacer<br />

1mm 'L' shaped<br />

packers as required<br />

Jamb liner. Use screws<br />

to secure joinery<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


SHEET CLADDING<br />

Joinery Sill on Cavity<br />

Scale 1:2<br />

120x120x20mm PVC<br />

internal corner cover<br />

placed under<br />

building underlay<br />

Precut left and right<br />

aluminium stop end<br />

Window support blocks<br />

supplied with aluminium<br />

joinery<br />

12<br />

25x35x6mm foam<br />

air seal block to<br />

both sides of sill<br />

9x9mm air seal<br />

fitted to inside edge<br />

of support bar<br />

Self tapping SS 6 gauge<br />

20mm long sq. dr.<br />

counter sunk screws<br />

8mm cover min.<br />

Plywood or other sheet<br />

cladding up to 12mm<br />

thick<br />

Selected building<br />

underlay<br />

Cavity battens rebated<br />

at top ends to allow for<br />

thickness of Supersill<br />

Timber stud framing<br />

and insulation<br />

Surefast SS 8 gauge 20-<br />

25mm sq. dr.<br />

countersunk screws<br />

Selected window architrave<br />

Selected internal<br />

lining<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


SHEET CLADDING<br />

Joinery Jamb on Cavity<br />

Scale 1:2<br />

Cavity battens<br />

Plywood or other sheet<br />

cladding up to 12mm<br />

thick<br />

Timber stud framing and<br />

insulation<br />

Selected internal lining Selected window architrave<br />

18<br />

Note: Allow 18mm (ideal) between<br />

jamb and framing for finrail / seal<br />

10 mm cover<br />

Continuous protective sealant<br />

Foam bond breaker<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson<br />

20 mm head flashing<br />

extension<br />

Selected aluminium joinery<br />

Rear seal in finrail<br />

Finseal<br />

Finrail<br />

PVC internal corner cover<br />

placed under building underlay<br />

Flashtec click in jamb liner<br />

spacer<br />

1mm 'L' shaped packers<br />

as required<br />

Jamb liner. Use screws to<br />

secure joinery


BRICK VENEER<br />

Joinery Head<br />

Scale 1:2<br />

Note: Allow 18mm (ideal) between<br />

head and framing for finrail / seal<br />

Selected building<br />

underlay<br />

Timber stud<br />

framing and<br />

insulation<br />

Selected brick<br />

veneer<br />

Head flashing<br />

turned into angle or<br />

flat steel lintel.<br />

Extend flashing<br />

200mm each side<br />

of opening<br />

Drainage holes in<br />

veneer<br />

Steel lintel<br />

flashing upstand<br />

Selected internal<br />

lining<br />

Selected window<br />

architrave<br />

Rear seal in finrail<br />

18<br />

Sealant<br />

Finrail<br />

Selected<br />

aluminium<br />

joinery<br />

Finseal<br />

PVC internal corner<br />

cover placed under<br />

building underlay<br />

Flashtec click in<br />

jamb liner spacer<br />

1mm 'L' shaped<br />

packers as<br />

required<br />

Jamb liner. Use<br />

screws to secure<br />

joinery<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


BRICK VENEER<br />

Joinery Sill<br />

Scale 1:2<br />

120x120x20mm PVC<br />

internal corner cover<br />

placed under building<br />

underlay<br />

Precut left and right<br />

aluminium stop end<br />

Window support blocks<br />

supplied with aluminium<br />

joinery<br />

25x35x6mm foam<br />

air seal block to<br />

both sides of sill<br />

9x9mm air seal<br />

fitted to inside edge<br />

of support bar<br />

Joinery sill, do not seal<br />

to brick sill<br />

12<br />

Self tapping SS 6 gauge<br />

20mm long sq. dr.<br />

counter sunk screws<br />

Brick sill cantilevered or<br />

flush with min 15º slope<br />

Surefast SS 8 gauge 20-<br />

25mm sq. dr.<br />

countersunk screws<br />

Selected window architrave<br />

Selected internal lining<br />

Selected<br />

building<br />

underlay<br />

Timber stud<br />

framing and<br />

insulation<br />

Sill flashing with drip<br />

edge, extend 200mm<br />

each side of window<br />

H3.2 timber kick-out fillet<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson


BRICK VENEER<br />

Joinery Jamb<br />

Scale 1:2<br />

Timber stud framing<br />

and insulation<br />

Selected window architrave<br />

Selected internal lining<br />

18<br />

Note: Allow 18mm (ideal) between<br />

jamb and framing for finrail / seal<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson<br />

Brick veneer<br />

Line of masonry wall tie<br />

Selected aluminium joinery<br />

Rear seal in finrail<br />

Finseal<br />

Finrail<br />

PVC internal corner cover<br />

placed under building underlay<br />

Flashtec click in jamb<br />

liner spacer<br />

1mm 'L' shaped packers<br />

as required<br />

Jamb liner. Use screws to<br />

secure joinery


BRICK VENEER<br />

Joinery Sill with Rebate<br />

Scale 1:2<br />

120x120x20mm PVC<br />

internal corner cover<br />

placed under building<br />

underlay<br />

Precut left and right<br />

aluminium stop end<br />

Window support blocks<br />

supplied with aluminium<br />

joinery<br />

Joinery sill, do not seal<br />

to brick sill<br />

33<br />

25x35x6mm foam<br />

air seal block to<br />

both sides of sill<br />

9x9mm air seal<br />

fitted to inside edge<br />

of support bar<br />

Self tapping SS 6 gauge<br />

20mm long sq. dr. counter<br />

sunk screws<br />

Brick sill cantilevered or<br />

flush with min 15º slope<br />

Surefast SS 8 gauge 20-<br />

25mm sq. dr. countersunk<br />

screws in tappet to suit<br />

DPC between flashrail<br />

and concrete<br />

FLASHTEC PRODUCTS LTD<br />

09 836 6366<br />

www.flashtec.co.nz<br />

10A Clemway Place, Henderson

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!