<strong>Cyto</strong>-Set ®<br />

Safer cytostatic preparation and application<br />

IV Adm<strong>in</strong>istration


Always a closed system …<br />

Protect yourself and your environment<br />

The number of cytostatic <strong>in</strong>fusions that have to be prepared is<br />

grow<strong>in</strong>g while the time available for setup and adm<strong>in</strong>istration<br />

keeps gett<strong>in</strong>g shorter. But even small amounts of these potent<br />

drugs can pose health hazards. That’s why the handl<strong>in</strong>g of cytostatic<br />

agents requires your undivided attention.<br />

Only a system that doesn’t allow risks and hazards to happen <strong>in</strong><br />

the first place can protect you effectively!<br />

The <strong>in</strong>tegrated safety components <strong>in</strong> <strong>Cyto</strong>-<strong>Set®</strong> form a closed<br />

system right from the first handl<strong>in</strong>g step to the very last, from<br />

preparation to disposal.<br />

Protect yourself and your environment. Use <strong>Cyto</strong>-<strong>Set®</strong> and<br />

experience that safe handl<strong>in</strong>g feel<strong>in</strong>g.


… while prepar<strong>in</strong>g …<br />

Safe drug preparation <strong>in</strong> the pharmacy with <strong>Cyto</strong>-<strong>Set®</strong> Mix<br />

Start by fill<strong>in</strong>g <strong>Cyto</strong>-<strong>Set®</strong> Mix with carrier solution and then<br />

prim<strong>in</strong>g it through Prime Stop before you <strong>in</strong>ject the cytostatic<br />

drug. This method effectively elim<strong>in</strong>ates the risk of cytostatic<br />

contam<strong>in</strong>ation at the connection site.<br />

The Safsite® connectors prevent leaks and needlesticks.<br />

The only th<strong>in</strong>g allowed is the needle-free <strong>in</strong>jection of the<br />

cytostatic drug <strong>in</strong>to the l<strong>in</strong>e. Just one more added safety<br />

feature to protect pharmacy staff.<br />

<strong>Cyto</strong>-<strong>Set®</strong> Safety System<br />

<strong>Cyto</strong>-<strong>Set®</strong> Mix for centralized admix<strong>in</strong>g and <strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong>/<br />

Infusomat® Space for stationary preparation and application<br />

always form a closed system.<br />

All connections rema<strong>in</strong> free of cytostatic agents and can only<br />

be wetted with the carrier or flush<strong>in</strong>g solution.<br />

<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e connects primed solutions.<br />

<strong>Cyto</strong>-<strong>Set®</strong> Mix<br />

<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e<br />

Safe Preparation


IV Adm<strong>in</strong>istration<br />

... and safe drug application!<br />

<strong>Cyto</strong>-<strong>Set®</strong><br />

Infusomat® Space<br />

<strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong>/Infusomat® Space<br />

Safe drug application on the ward<br />

On the ward, prepare the <strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong>/Infusomat® Space<br />

separately from the cytostatic. Fill the system completely with<br />

flush<strong>in</strong>g solution (e.g. Sodium Chloride) and vent through Prime<br />

Stop. Dur<strong>in</strong>g prim<strong>in</strong>g, the <strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong>/Infusomat® Space<br />

is only filled with flush<strong>in</strong>g solution, ensur<strong>in</strong>g safe prim<strong>in</strong>g.<br />

The <strong>Cyto</strong>-<strong>Set®</strong> Mix prepared <strong>in</strong> the pharmacy is now connected<br />

to Safsite® valves: A tactile click lets you know that the sets are<br />

securely connected. This method allows you to connect up to<br />

four <strong>Cyto</strong>-<strong>Set®</strong> Mix <strong>in</strong>fusions to the system, ensur<strong>in</strong>g always<br />

safe drug application.<br />

Flush the IV Set with flush<strong>in</strong>g solution to prevent <strong>in</strong>teractions<br />

between different cytostatics.<br />

Avoid contam<strong>in</strong>ation with cytostatic agents by flush<strong>in</strong>g the<br />

tub<strong>in</strong>g after the f<strong>in</strong>al <strong>in</strong>fusion. The entire IV Set is disposed<br />

of as a closed system, ensur<strong>in</strong>g safe disposal.<br />

Safe Application


… for safer cytostatic handl<strong>in</strong>g!<br />

User benefits<br />

• “Closed system” from preparation<br />

and application to disposal<br />

• All connection sites are free<br />

of cytotoxic drugs<br />

• Easy, drip-free prim<strong>in</strong>g<br />

• Needle-free system<br />

• Less risk of cytostatic contam<strong>in</strong>ation<br />

• Light protection for photosensitive drugs<br />

PVC/DEHP-free Neutrapur®<br />

tub<strong>in</strong>g. Particularly patientfriendly.<br />

No plasticizer leachable.<br />

Ecologogical disposal.<br />

Back check valve prevents<br />

backflow and offers higher<br />

safety dur<strong>in</strong>g parallel pressure<br />

and gravity <strong>in</strong>fusions.<br />

Safsite® valve offers<br />

convenient and safe needlefree<br />

access for <strong>in</strong>jection,<br />

aspiration or parallel <strong>in</strong>fusions<br />

as a closed system.<br />

Vented spike with back<br />

check valve prevents fluid<br />

from dripp<strong>in</strong>g out.<br />

Prime stop ensures safe and<br />

dry prim<strong>in</strong>g. Ma<strong>in</strong>ta<strong>in</strong>s closed<br />

system until connected to<br />

patient.<br />

Tub<strong>in</strong>g and drip chamber with<br />

transparent light protection to<br />

recognize residual air <strong>in</strong> the<br />

tub<strong>in</strong>g and drips <strong>in</strong> the drip<br />

chamber with normal eyesight.<br />

Rotat<strong>in</strong>g Luer-Lock connector<br />

permits safer and more<br />

convenient connection<br />

without twist<strong>in</strong>g the tube.<br />

Advanced precise roller clamp<br />

offers a good to control flow<br />

rate. Comfortable to hold.<br />

Spike dock for secure spike<br />

discard.


<strong>Cyto</strong>-Set ® Preparation Type BCV<br />

Light<br />

protection<br />

Code No. (REF) Sales unit<br />

<strong>Cyto</strong>-<strong>Set®</strong> Mix with 1 Safsite® A 2901 N 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> Mix with 1 Safsite® • A 2902 N 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> Mix with 1 Safsite® • opaque* A 2904 N 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> Mix with 1 Safsite® •<br />

transparent<br />

light protection<br />

A 2905 N 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> Mix<br />

with 1 Safsite®,<br />

•<br />

with filter<br />

A 29023 N 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e without Safsite® A 2581 NF 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e without Safsite® • A 25811 NF 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e<br />

without Safsite®,<br />

with filter<br />

• A 25812 NF 20<br />

Application (Gravity) Type Code No. (REF) Sales unit<br />

<strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong> with 3 Safsite® A 1686 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong> with 5 Safsite® A 1685 SNF 20<br />

Application (Pump)<br />

Infusomat® Space<br />

Type<br />

Injection ports<br />

BCV<br />

Light<br />

protection<br />

Code No. (REF)<br />

Sales unit<br />

<strong>Cyto</strong>-<strong>Set®</strong> with 3 Safsite® 8250910 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> with 5 Safsite® 8250812 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong><br />

with 5 Safsite®<br />

and 0.2 μm filter<br />

8250413 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> with 3 Safsite® • 8250913 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> with 3 Safsite® • opaque* 8250915 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> with 3 Safsite®<br />

transparent<br />

light protection<br />

8250916 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> with 5 Safsite® • 8250813 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> with 5 Safsite® • opaque* 8250818 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong> with 5 Safsite®<br />

transparent<br />

light protection<br />

8250819 SP 20<br />

<strong>Cyto</strong>-<strong>Set®</strong><br />

Pump Adapter<br />

with 4 Safsite® A 1672 SO 20<br />

Spikes Code No. (REF) Sales unit<br />

M<strong>in</strong>i-Spike® V Chemo 4550587 50<br />

* conta<strong>in</strong>s PVC<br />

B. Braun Melsungen AG | Hospital Care | 34209 Melsungen | Germany<br />

Tel. +49 5661 71-0 | www.bbraun.com