Cyto-Set® - Risk Prevention in Infusion Therapy
Cyto-Set® - Risk Prevention in Infusion Therapy
Cyto-Set® - Risk Prevention in Infusion Therapy
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Cyto</strong>-Set ®<br />
Safer cytostatic preparation and application<br />
IV Adm<strong>in</strong>istration
Always a closed system …<br />
Protect yourself and your environment<br />
The number of cytostatic <strong>in</strong>fusions that have to be prepared is<br />
grow<strong>in</strong>g while the time available for setup and adm<strong>in</strong>istration<br />
keeps gett<strong>in</strong>g shorter. But even small amounts of these potent<br />
drugs can pose health hazards. That’s why the handl<strong>in</strong>g of cytostatic<br />
agents requires your undivided attention.<br />
Only a system that doesn’t allow risks and hazards to happen <strong>in</strong><br />
the first place can protect you effectively!<br />
The <strong>in</strong>tegrated safety components <strong>in</strong> <strong>Cyto</strong>-<strong>Set®</strong> form a closed<br />
system right from the first handl<strong>in</strong>g step to the very last, from<br />
preparation to disposal.<br />
Protect yourself and your environment. Use <strong>Cyto</strong>-<strong>Set®</strong> and<br />
experience that safe handl<strong>in</strong>g feel<strong>in</strong>g.
… while prepar<strong>in</strong>g …<br />
Safe drug preparation <strong>in</strong> the pharmacy with <strong>Cyto</strong>-<strong>Set®</strong> Mix<br />
Start by fill<strong>in</strong>g <strong>Cyto</strong>-<strong>Set®</strong> Mix with carrier solution and then<br />
prim<strong>in</strong>g it through Prime Stop before you <strong>in</strong>ject the cytostatic<br />
drug. This method effectively elim<strong>in</strong>ates the risk of cytostatic<br />
contam<strong>in</strong>ation at the connection site.<br />
The Safsite® connectors prevent leaks and needlesticks.<br />
The only th<strong>in</strong>g allowed is the needle-free <strong>in</strong>jection of the<br />
cytostatic drug <strong>in</strong>to the l<strong>in</strong>e. Just one more added safety<br />
feature to protect pharmacy staff.<br />
<strong>Cyto</strong>-<strong>Set®</strong> Safety System<br />
<strong>Cyto</strong>-<strong>Set®</strong> Mix for centralized admix<strong>in</strong>g and <strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong>/<br />
Infusomat® Space for stationary preparation and application<br />
always form a closed system.<br />
All connections rema<strong>in</strong> free of cytostatic agents and can only<br />
be wetted with the carrier or flush<strong>in</strong>g solution.<br />
<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e connects primed solutions.<br />
<strong>Cyto</strong>-<strong>Set®</strong> Mix<br />
<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e<br />
Safe Preparation
IV Adm<strong>in</strong>istration<br />
... and safe drug application!<br />
<strong>Cyto</strong>-<strong>Set®</strong><br />
Infusomat® Space<br />
<strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong>/Infusomat® Space<br />
Safe drug application on the ward<br />
On the ward, prepare the <strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong>/Infusomat® Space<br />
separately from the cytostatic. Fill the system completely with<br />
flush<strong>in</strong>g solution (e.g. Sodium Chloride) and vent through Prime<br />
Stop. Dur<strong>in</strong>g prim<strong>in</strong>g, the <strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong>/Infusomat® Space<br />
is only filled with flush<strong>in</strong>g solution, ensur<strong>in</strong>g safe prim<strong>in</strong>g.<br />
The <strong>Cyto</strong>-<strong>Set®</strong> Mix prepared <strong>in</strong> the pharmacy is now connected<br />
to Safsite® valves: A tactile click lets you know that the sets are<br />
securely connected. This method allows you to connect up to<br />
four <strong>Cyto</strong>-<strong>Set®</strong> Mix <strong>in</strong>fusions to the system, ensur<strong>in</strong>g always<br />
safe drug application.<br />
Flush the IV Set with flush<strong>in</strong>g solution to prevent <strong>in</strong>teractions<br />
between different cytostatics.<br />
Avoid contam<strong>in</strong>ation with cytostatic agents by flush<strong>in</strong>g the<br />
tub<strong>in</strong>g after the f<strong>in</strong>al <strong>in</strong>fusion. The entire IV Set is disposed<br />
of as a closed system, ensur<strong>in</strong>g safe disposal.<br />
Safe Application
… for safer cytostatic handl<strong>in</strong>g!<br />
User benefits<br />
• “Closed system” from preparation<br />
and application to disposal<br />
• All connection sites are free<br />
of cytotoxic drugs<br />
• Easy, drip-free prim<strong>in</strong>g<br />
• Needle-free system<br />
• Less risk of cytostatic contam<strong>in</strong>ation<br />
• Light protection for photosensitive drugs<br />
PVC/DEHP-free Neutrapur®<br />
tub<strong>in</strong>g. Particularly patientfriendly.<br />
No plasticizer leachable.<br />
Ecologogical disposal.<br />
Back check valve prevents<br />
backflow and offers higher<br />
safety dur<strong>in</strong>g parallel pressure<br />
and gravity <strong>in</strong>fusions.<br />
Safsite® valve offers<br />
convenient and safe needlefree<br />
access for <strong>in</strong>jection,<br />
aspiration or parallel <strong>in</strong>fusions<br />
as a closed system.<br />
Vented spike with back<br />
check valve prevents fluid<br />
from dripp<strong>in</strong>g out.<br />
Prime stop ensures safe and<br />
dry prim<strong>in</strong>g. Ma<strong>in</strong>ta<strong>in</strong>s closed<br />
system until connected to<br />
patient.<br />
Tub<strong>in</strong>g and drip chamber with<br />
transparent light protection to<br />
recognize residual air <strong>in</strong> the<br />
tub<strong>in</strong>g and drips <strong>in</strong> the drip<br />
chamber with normal eyesight.<br />
Rotat<strong>in</strong>g Luer-Lock connector<br />
permits safer and more<br />
convenient connection<br />
without twist<strong>in</strong>g the tube.<br />
Advanced precise roller clamp<br />
offers a good to control flow<br />
rate. Comfortable to hold.<br />
Spike dock for secure spike<br />
discard.
<strong>Cyto</strong>-Set ® Preparation Type BCV<br />
Light<br />
protection<br />
Code No. (REF) Sales unit<br />
<strong>Cyto</strong>-<strong>Set®</strong> Mix with 1 Safsite® A 2901 N 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> Mix with 1 Safsite® • A 2902 N 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> Mix with 1 Safsite® • opaque* A 2904 N 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> Mix with 1 Safsite® •<br />
transparent<br />
light protection<br />
A 2905 N 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> Mix<br />
with 1 Safsite®,<br />
•<br />
with filter<br />
A 29023 N 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e without Safsite® A 2581 NF 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e without Safsite® • A 25811 NF 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> L<strong>in</strong>e<br />
without Safsite®,<br />
with filter<br />
• A 25812 NF 20<br />
Application (Gravity) Type Code No. (REF) Sales unit<br />
<strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong> with 3 Safsite® A 1686 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> <strong>Infusion</strong> with 5 Safsite® A 1685 SNF 20<br />
Application (Pump)<br />
Infusomat® Space<br />
Type<br />
Injection ports<br />
BCV<br />
Light<br />
protection<br />
Code No. (REF)<br />
Sales unit<br />
<strong>Cyto</strong>-<strong>Set®</strong> with 3 Safsite® 8250910 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> with 5 Safsite® 8250812 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong><br />
with 5 Safsite®<br />
and 0.2 μm filter<br />
8250413 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> with 3 Safsite® • 8250913 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> with 3 Safsite® • opaque* 8250915 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> with 3 Safsite®<br />
transparent<br />
light protection<br />
8250916 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> with 5 Safsite® • 8250813 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> with 5 Safsite® • opaque* 8250818 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong> with 5 Safsite®<br />
transparent<br />
light protection<br />
8250819 SP 20<br />
<strong>Cyto</strong>-<strong>Set®</strong><br />
Pump Adapter<br />
with 4 Safsite® A 1672 SO 20<br />
Spikes Code No. (REF) Sales unit<br />
M<strong>in</strong>i-Spike® V Chemo 4550587 50<br />
* conta<strong>in</strong>s PVC<br />
B. Braun Melsungen AG | Hospital Care | 34209 Melsungen | Germany<br />
Tel. +49 5661 71-0 | www.bbraun.com