THE REAL UVT ONLINE MONITOR<br />

• • • • • • • • • • • • • • with <strong>the</strong> innovative • • • • • • • • • • • • • •<br />

ORTHO-BEAM TECHNOLOGY<br />

ONLINE<br />

KEY FEATURES:<br />

• Patent pending Ortho-Beam <strong>technology</strong><br />

• UV 254nm wavelength<br />

• Continuous automatic calibration<br />

• Performs both UVT & UVA measurements<br />

• Significantly reduced need for cleaning<br />

• 4-20mA output<br />

• RS232 for data logging via PC<br />

• Dry contacts for user configurable alarms<br />

• NEMA 4X enclosure<br />

• Dual feed option<br />

• Operates from 24 VDC<br />

• User friendly interface<br />

• 2 year warranty<br />

• Affordable<br />

WHAT IS THE REAL UVT ONLINE?<br />

The Real UVT Online <strong>monitor</strong> provides continuous <strong>real</strong> time UV254 testing. The Real<br />

UVT Online is designed with patent pending Ortho-Beam <strong>technology</strong> to provide many<br />

significant advantages while maintaining affordability.<br />

The innovative Ortho-Beam <strong>technology</strong> allows for continuous<br />

automatic calibration during operation, <strong>the</strong>reby enabling <strong>the</strong><br />

Real UVT Online to overcome <strong>the</strong> many challenges faced by<br />

o<strong>the</strong>r similar instrumentation.<br />

The Real UVT Online’s unique ability to automatically detect<br />

and compensate for UV lamp fluctuations and quartz fouling<br />

prevents a loss in accuracy over time and significantly<br />

reduces maintenance.<br />

MEASURING ORGANICS<br />

UV254 provides an indication of <strong>the</strong> amount of natural<br />

organic matter (NOM) in water and wastewater. More specifically,<br />

UV254 is <strong>the</strong> best detector of aromatic organics or reactive NOM.<br />

Aromatic organics are problematic, having several negative effects.<br />

For example, when combined with chlorine, aromatic organics readily<br />

form disinfection by-products (DBPs).<br />

The Real UVT Online <strong>monitor</strong> is <strong>the</strong> ideal solution for <strong>monitor</strong>ing<br />

UV254 instantaneously in <strong>real</strong> time. The Real UVT Online <strong>monitor</strong><br />

can also be used as a practical alternative or supplement to measuring<br />

o<strong>the</strong>r organic test parameters such as TOC, DOC, BOD and COD.<br />

BENEFICIAL APPLICATIONS INCLUDE<br />

· coagulation optimization · filter performance<br />

· DBP formation potential · UV disinfection<br />

· effluent <strong>monitor</strong>ing<br />

· process control<br />

· plant security/safety<br />

· and more...<br />

PROVIDING REAL ORGANIC TESTING SOLUTIONS<br />

WWW.REALTECH.CA<br />

REAL TECH INC. CANADA<br />

T. 1 877 779 2888<br />

E. INFO@REALTECH.CA


THE REAL UVT ONLINE’S PATENT PENDING ORTHO-BEAM TECHNOLOGY PROVIDES<br />

INCREASED ACCURACY, REDUCED MAINTENANCE AND AFFORDABILITY<br />

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••<br />

REAL UVT ONLINE TECHNICAL SPECIFICATIONS<br />

R ANGE<br />

0 – 100 % UV T, 0 – 2 UVA<br />

ACCUR ACY<br />

1.0 % UVT<br />

REPEATABILITY 0.1% UVT<br />

RESOLUTION<br />

0.1% UVT, 0.001 UVA<br />

-1<br />

UNITS<br />

Operator configurable: cm ,m -1<br />

PATH LENGTH<br />

1 cm<br />

SAMPLING TIME<br />

10 seconds<br />

FLOW RATE<br />

300 – 800 mL / min<br />

CALIBRATION<br />

Ortho-Beam <strong>technology</strong> allows continuous automatic calibration during operation<br />

• Significantly reduced cleaning requirements due to Ortho-Beam <strong>technology</strong><br />

CLEANING<br />

• Automatic cleaning optional<br />

SELF DIAGNOSTICS<br />

Detection and diagnosis of internal system fault<br />

OPERATOR INTERFACE<br />

Five pushbuttons to control a comprehensive hierarchical menu system<br />

• 4 line x 20 character backlit LCD<br />

DISPLAY<br />

• Multi-colour indicator light for system alarms and warnings<br />

Dry-contact terminals allow operator configurable alarms for:<br />

• High and low UVT/UVA setpoints<br />

AL AR MS<br />

• Low lamp output<br />

• Leak detected<br />

• electrical and system fault<br />

HUMIDITY CONTROL<br />

Humidity sensor with large regeneratable desiccant system<br />

ME MOR Y<br />

Operator configurable memory stores sample readings<br />

• 4-20 mA output configurable to ei<strong>the</strong>r UVT or UVA<br />

OUT P UTS<br />

• Dry-contact terminals for alarm conditions<br />

• RS232 for data logging via PC<br />

WAVELENGTH<br />

253.7 nm<br />

LIGHT SOURCE<br />

Low pressure mercury UV lamp<br />

L AMP L IFE<br />

2 years<br />

DIMENSIONS<br />

16”h x 14”w x 8”d<br />

ENCLOSURE<br />

NEMA 4X, wall mountable<br />

FLUID CONNECTIONS<br />

1/4” tube compression in/out<br />

ELECTRICAL<br />

24 VDC 20W power adapter (accepts 90-250 VAC 50/60 Hz)<br />

STORAGE TEMP<br />

-20 to 60°C (-4 to 140°F)<br />

OPERATING TEMP<br />

0 to 45°C (32 to 113°F)<br />

WARRANTY<br />

2 year limited warranty<br />

• Dual feed • Real Clean automatic chemical cleaning • Turbidity compensation<br />

OPTIONS<br />

• Open channel / Non-pressurized pump system<br />

PERFORM UV254 ORGANIC TESTING CONTINUOUSLY!<br />

PROVIDING REAL ORGANIC TESTING SOLUTIONS<br />

For customer service, call 1300-735-295<br />

WWW.REALTECH.CA<br />

Email: InfoWaterAU@<strong>the</strong>rmofisher.com<br />

REAL TECH INC. CANADA<br />

Visit us <strong>online</strong>: www.<strong>the</strong>rmofisher.com.au<br />

©2010 <strong>Thermo</strong> <strong>Fisher</strong> Scientific Inc. All rights reserved. A.B.N. 52 058 390 917<br />

T. 1 877 779 2888<br />

E. INFO@REALTECH.CA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!