www.trios.de<br />

<strong>enviroFlu</strong>-<strong>HC</strong><br />

<strong>PAH</strong>, <strong>Oil</strong>-<strong>in</strong>-<strong>Water</strong><br />

by UV-fluorescence<br />

Enviro-Flu-<strong>HC</strong> is a new generation of highsensitive submersible<br />

sensors for oil-<strong>in</strong>-water measurement. The used UV fluorescence<br />

pr<strong>in</strong>ciple for detection is much more sensitive than<br />

any other exist<strong>in</strong>g detection pr<strong>in</strong>ciple, like <strong>in</strong>frared scatter<strong>in</strong>g,<br />

etc. This allows the detection of <strong>PAH</strong> traces <strong>in</strong> water down<br />

to s<strong>in</strong>gle ppb levels, e.g. <strong>in</strong> dr<strong>in</strong>k<strong>in</strong>gwater or condensate applications.<br />

Typical applications are discharge monitor<strong>in</strong>g of<br />

airports and factories, leakage detection and many others.<br />

The sensors can be used either <strong>in</strong> stationary or portable applications.<br />

A new <strong>in</strong>novative coat<strong>in</strong>g on the lenses is prevent<strong>in</strong>g<br />

the optics for foul<strong>in</strong>g and oil-flims, mak<strong>in</strong>g the <strong>enviroFlu</strong>-<br />

<strong>HC</strong> longterm stable and virtually ma<strong>in</strong>tenance free.<br />

<strong>enviroFlu</strong>-<strong>HC</strong><br />

- dr<strong>in</strong>k<strong>in</strong>g water<br />

- waste water<br />

- airport monitor<strong>in</strong>g<br />

- cool<strong>in</strong>g water<br />

- desal<strong>in</strong>ation<br />

- reff<strong>in</strong>eries<br />

- pipel<strong>in</strong>e leakage detection<br />

water flow<br />

TriOS Optical sensors - Werftweg 15 - D-26135 Oldenburg - Germany - <strong>in</strong>fo@trios.de


<strong>enviroFlu</strong>-<strong>HC</strong><br />

Info<br />

UV-fluorometer for the detection of <strong>PAH</strong> <strong>in</strong> water<br />

(Ex: 254nm/Em: 360nm)<br />

ranges: <strong>enviroFlu</strong>-<strong>HC</strong> 500: 0..50ppb, 0..500ppb<br />

<strong>enviroFlu</strong>-<strong>HC</strong> 5000: 0..500ppb, 0..5000ppb<br />

detection limits: 0.1ppb (<strong>in</strong> pure water)<br />

(calibrated to phenanthrene solution)<br />

Values can be transformed to total-oil concentrations giv<strong>in</strong>g<br />

typical detection ranges of up to 200ppm total oil.<br />

<strong>in</strong>terfaces: RS232, 0..5VDC, 4..20mA<br />

hous<strong>in</strong>g: POM and sta<strong>in</strong>less steel (1.4571) or titanium<br />

approx 1,8kg (sta<strong>in</strong>lesssteel)<br />

9..36 VDC<br />

d=68x280mm (without connector)<br />

0..40°C<br />

<strong>PAH</strong>: Polycyclic Aromatic Hydrocarbons<br />

Safety armatur for pipe <strong>in</strong>stallation<br />

TriBox II<br />

order codes<br />

10 1032 <strong>enviroFlu</strong>-<strong>HC</strong> 500 (sta<strong>in</strong>less)<br />

10 1033 <strong>enviroFlu</strong>-<strong>HC</strong> 5000 (sta<strong>in</strong>less)<br />

10 1030 <strong>enviroFlu</strong>-<strong>HC</strong> Ti 500 (titanium)<br />

10 1031 <strong>enviroFlu</strong>-<strong>HC</strong> Ti 5000 (titanium)<br />

41 0000 TriBox II (controller)<br />

22 8000 safety armatur<br />

70 4001 airclean head<br />

A new <strong>in</strong>novative nano-coat<strong>in</strong>g on the optical<br />

lens prevents oil-films and foul<strong>in</strong>g.<br />

For For customer customer service, service, call call 1300-735-295 1300-735-295<br />

Email: Email: InfoEnviroAU@thermofisher.com<br />

Info<strong>Water</strong>AU@thermofisher.com<br />

Visit Visit us us onl<strong>in</strong>e: onl<strong>in</strong>e: www.thermofisher.com.au<br />

www.thermofisher.com.au<br />

©2010 <strong>Thermo</strong> <strong>Fisher</strong> Scientific Inc. All rights reserved. A.B.N. 52 058 390 917<br />

©2010 <strong>Thermo</strong> <strong>Fisher</strong> Scientific Inc. All rights reserved. A.B.N. 52 058 390 917

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!