<strong>Outotec</strong> FeCr process is superior to<br />

any other FeCr process<br />

<strong>Outotec</strong> Process<br />

Open furnace<br />

Electricity consumption<br />

2,950-3,300 kWh/t FeCr<br />

with pellets+lumpy<br />

4,200-4,800 kWh/t FeCr<br />

with conc./fines+lumpy<br />

3,800 kWh /t FeCr with<br />

pellets+conc./fines+lumpy<br />

Cr recovery 83-90% 72-80%<br />

Consumption of electrode paste 7-10 kg t/FeCr 15-25 kg/t FeCr<br />

Availability, based on operating hours 95-98% 85-94%<br />

Formation of furnace gas (CO 85-90%) 700 Nm 3 /t FeCr CO is burned and lost<br />

Gas amount/heating value<br />

(e.g. 60 MW)<br />

12727 Nm 3 /38.1 MW Lost /Lost<br />

Cr 6+ in dust 5-100 ppm 1,000-7,000 ppm<br />

CO 2 emissions<br />

1,330 kg<br />

CO 2 /t FeCr<br />

1,400-1,470 kg<br />

CO 2 /t FeCr<br />

22 Nov 15, 2011 <strong>Outotec</strong> CMD/<strong>Ferrous</strong> <strong>Solutions</strong><br />