27.10.2014 Views

Green Stud Welding Technologies - NSRP

Green Stud Welding Technologies - NSRP

Green Stud Welding Technologies - NSRP

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Copyright © Nelson <strong>Stud</strong> <strong>Welding</strong>, Inc.<br />

Power Factor & efficiency – Drawn<br />

Arc<br />

In idle: transrec<br />

consumes<br />

70X more kVA<br />

(1.145KW savings)<br />

In welding:<br />

N1500i<br />

consumes half<br />

the kVA<br />

(2.25KW savings)<br />

N800i<br />

Inverter<br />

N1500i<br />

Inverter<br />

N6000<br />

Trans-<br />

Rec<br />

S5000<br />

Trans-<br />

Rec<br />

KW idle 0.05 0.06 1.2 1.2<br />

KVA idle 0.06 0.08 5.9 2.2<br />

PF idle 0.4 0.3 0.2 0.5<br />

Load<br />

800A<br />

27V<br />

800A<br />

42V<br />

800A<br />

27V<br />

800A<br />

27V<br />

KW load 29.2 28.4 31 35.6<br />

kVA load 40 39 81 59.8<br />

PF load 0.72 0.71 0.35 0.57<br />

Efficiency 0.74 0.76 0.70 0.61<br />

May 8, 2012<br />

<strong>NSRP</strong> <strong>Welding</strong> Panel Meeting Fort Collins 2012<br />

7