Security Center Release Notes 5.1 SR2 | Download latest - Genetec
Security Center Release Notes 5.1 SR2 | Download latest - Genetec
Security Center Release Notes 5.1 SR2 | Download latest - Genetec
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Security</strong> <strong>Center</strong><br />
<strong>Release</strong> <strong>Notes</strong><br />
<strong>5.1</strong> <strong>SR2</strong><br />
Click here for the most recent version of this guide.
Copyright notice<br />
© 2011, 2012 <strong>Genetec</strong> Inc. All rights reserved.<br />
<strong>Genetec</strong> Inc. distributes this document with software that includes an end-user license agreement and is<br />
furnished under license and may be used only in accordance with the terms of the license agreement. The<br />
contents of this document are protected under copyright law.<br />
The contents of this guide are furnished for informational use only and are subject to change without notice.<br />
<strong>Genetec</strong> Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in the<br />
informational content contained in this guide.<br />
This publication may not be copied, modified, or reproduced in any form or for any purpose, nor can any<br />
derivative works be created therefrom without <strong>Genetec</strong> Inc.’s prior written consent.<br />
<strong>Genetec</strong> Inc. reserves the right to revise and improve its products as it sees fit. This document describes the<br />
state of a product at the time of document’s last revision, and may not reflect the product at all times in the<br />
future.<br />
In no event shall <strong>Genetec</strong> Inc. be liable to any person or entity with respect to any loss or damage that is<br />
incidental to or consequential upon the instructions found in this document or the computer software and<br />
hardware products described herein. The use of this document is subject to the disclaimer of liability found<br />
in the end–user license agreement.<br />
"<strong>Genetec</strong>", "Omnicast", "Synergis", "Synergis Master Controller", "AutoVu", "Federation", the <strong>Genetec</strong><br />
stylized "G" and the Omnicast, Synergis and AutoVu logos are trademarks of <strong>Genetec</strong> Inc., either registered<br />
or pending registration in several jurisdictions.<br />
"<strong>Security</strong> <strong>Center</strong>", "<strong>Security</strong> <strong>Center</strong> Mobile", "Plan Manager", and the <strong>Security</strong> <strong>Center</strong> logo are trademarks of<br />
<strong>Genetec</strong> Inc.<br />
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers<br />
or vendors of the respective products.<br />
All specifications are subject to change without notice.<br />
Document information<br />
Document title: <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Document number: EN.500.001-V<strong>5.1</strong>.C2(1)<br />
Document update date: July 16, 2012<br />
You can send your comments, corrections, and suggestions about this guide to<br />
documentation@genetec.com.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version<br />
EN.500.001-V<strong>5.1</strong>.C2(1)<br />
ii
Product documentation<br />
<strong>Security</strong> <strong>Center</strong> includes the following documentation:<br />
• <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong>. Describes the release in detail, including new features, resolved issues,<br />
known issues, and limitations.<br />
• <strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide. Describes the prerequisites for installing <strong>Security</strong><br />
<strong>Center</strong>, and provides instructions for installing and upgrading <strong>Security</strong> <strong>Center</strong> on your system.<br />
• <strong>Security</strong> <strong>Center</strong> Administrator Guide. Provides all the instructions and conceptual information you’ll<br />
need to set up, configure, and administer your <strong>Security</strong> <strong>Center</strong> system.<br />
• Getting Started with <strong>Security</strong> Desk. A task-oriented introduction to <strong>Security</strong> Desk that uses real-world<br />
scenarios (viewing a camera, searching/exporting video, and managing alarms) to show new users how<br />
to use the basic product features.<br />
• <strong>Genetec</strong> <strong>Security</strong> Desk User Guide. Provides the instructions and conceptual information you need to<br />
get started with <strong>Security</strong> Desk, to monitor and generate reports for AutoVu LPR, Omnicast video<br />
surveillance, and Synergis access control systems.<br />
• <strong>Security</strong> <strong>Center</strong> Video Unit Configuration Guide. Provides the pre-configuration instructions for<br />
integrating video units into <strong>Security</strong> <strong>Center</strong>, and any configuration steps required for some video unit<br />
features to work.<br />
• <strong>Security</strong> <strong>Center</strong> Portable Archive Player User Guide. Explains how to use the Portable Archive Player to<br />
view exported video files.<br />
• AutoVu Patroller <strong>Release</strong> <strong>Notes</strong>. Describes the AutoVu Patroller release in detail, including new<br />
features, resolved issues, known issues, and limitations.<br />
• AutoVu Hardware <strong>Release</strong> <strong>Notes</strong>. Describes the AutoVu Hardware for this release in detail, including<br />
new features, resolved issues, known issues, and limitations.<br />
• AutoVu Handbook. Provides AutoVu installers and administrators with a single source of information<br />
about installing and configuring AutoVu hardware and software.<br />
• AutoVu Patroller User Guides. Quick reference guides to using Patroller, AutoVu’s mobile LPR solution.<br />
There is a separate user guide for each Patroller installation type (Law Enforcement, City Parking<br />
Enforcement, City Parking Enforcement with Wheel Imaging, University Parking Enforcement, and<br />
Mobile License Plate Inventory).<br />
• AutoVu Connecting the Sharp Camera. Explains how to power up and connect your Sharp. A printed<br />
version is provided in the Sharp box.<br />
• AutoVu Connecting the SharpX Camera. Explains how to power up and connect your SharpX. A printed<br />
version is provided in the SharpX box.<br />
• Plugin User Guides. Introduces you to the plugin features and describes what’s new in the current<br />
release. It also explains how to install and configure the plugin in <strong>Security</strong> <strong>Center</strong>, and how to use it in<br />
<strong>Security</strong> Desk.<br />
Where can I find the product documentation?<br />
• Product DVD. The documentation is available on the product DVD in the Documentation folder. <strong>Release</strong><br />
notes and installation guides include a direct link to the <strong>latest</strong> version of the document.<br />
• <strong>Genetec</strong> Technical Assistance Portal (GTAP). The <strong>latest</strong> version of the documentation is available from<br />
GTAP. Note, you’ll need a username and password to log on to GTAP.<br />
• Online help. <strong>Security</strong> <strong>Center</strong> client applications include online help, which explain how the product<br />
works and provide instructions on how to use the product features. Patroller and the Sharp portal also<br />
include context-sensitive help for each screen. To access the online help, click Help, press F1, or tap<br />
the ? (question mark) in the different client applications.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version<br />
EN.500.001-V<strong>5.1</strong>.C2(1)<br />
iii
Technical support<br />
<strong>Genetec</strong> Technical Assistance <strong>Center</strong> (GTAC) is committed to providing its worldwide clientele with the best<br />
technical support services available. As a <strong>Genetec</strong> customer, you have access to the <strong>Genetec</strong> Technical<br />
Assistance Portal (GTAP), where you can find information and search for answers to your product questions.<br />
• <strong>Genetec</strong> Technical Assistance Portal (GTAP). GTAP is a support website that provides in-depth support<br />
information, such as FAQs, knowledge base articles, user guides, supported device lists, training videos,<br />
product tools, and much more.<br />
Prior to contacting GTAC or opening a support case, it is important to look at this website for potential<br />
fixes, workarounds, or known issues. You can log in to GTAP or sign up at https://gtap.genetec.com.<br />
• <strong>Genetec</strong> Technical Assistance <strong>Center</strong> (GTAC). If you cannot find your answers on GTAP, you can open a<br />
support case online at https://gtap.genetec.com. For GTAC's contact information in your region see the<br />
Contact page at https://gtap.genetec.com.<br />
NOTE Before contacting GTAC, please have your System ID (available from the About button in your client<br />
application) and your SMA contract number (if applicable) ready.<br />
• Licensing.<br />
• For license activations or resets, please contact GTAC at https://gtap.genetec.com.<br />
• For issues with license content or part numbers, or concerns about an order, please contact <strong>Genetec</strong><br />
Customer Service at customerservice@genetec.com, or call 1-866-684-8006 (option #3).<br />
• If you require a demo license or have questions regarding pricing, please contact <strong>Genetec</strong> Sales at<br />
sales@genetec.com, or call 1-866-684-8006 (option #2).<br />
Additional resources<br />
If you require additional resources other than the <strong>Genetec</strong> Technical Assistance <strong>Center</strong>, the following is<br />
available to you:<br />
• GTAP Forum. The Forum is an easy to use message board that allows clients and <strong>Genetec</strong> staff to communicate<br />
with each other and discuss a variety of topics, ranging from technical questions to technology<br />
tips. You can log in or sign up at https://gtapforum.genetec.com.<br />
• Technical training. In a professional classroom environment or from the convenience of your own office,<br />
our qualified trainers can guide you through system design, installation, operation, and troubleshooting.<br />
Technical training services are offered for all products and for customers with a varied level of technical<br />
experience, and can be customized to meet your specific needs and objectives. For more information, go<br />
to http://www.genetec.com/Services.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version<br />
EN.500.001-V<strong>5.1</strong>.C2(1)<br />
iv
Contents<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> <strong>Release</strong> <strong>Notes</strong><br />
Product documentation . . . . . . . . . . . . . . . . . . iii<br />
Technical support . . . . . . . . . . . . . . . . . . . iv<br />
Chapter 1: <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> <strong>Release</strong> <strong>Notes</strong><br />
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> . . . . . . . . . . . . . 1<br />
<strong>Security</strong> Desk enhancements . . . . . . . . . . . . . . . 1<br />
Synergis access control enhancements . . . . . . . . . . . . . 1<br />
Omnicast video surveillance enhancements. . . . . . . . . . . . 1<br />
Arecont enhancements . . . . . . . . . . . . . . . . 2<br />
ATEME enhancements . . . . . . . . . . . . . . . . 2<br />
Axis enhancements . . . . . . . . . . . . . . . . . 2<br />
Basler enhancements . . . . . . . . . . . . . . . . 3<br />
Bosch enhancements . . . . . . . . . . . . . . . . 3<br />
Canon enhancements . . . . . . . . . . . . . . . . 3<br />
<strong>Genetec</strong> Protocol enhancements . . . . . . . . . . . . . 4<br />
Interlogix enhancements . . . . . . . . . . . . . . . 4<br />
Mavix enhancements . . . . . . . . . . . . . . . . 4<br />
Panasonic enhancements . . . . . . . . . . . . . . . 4<br />
Pelco enhancements . . . . . . . . . . . . . . . . 5<br />
Sanyo enhancements . . . . . . . . . . . . . . . . 5<br />
Sony enhancements . . . . . . . . . . . . . . . . 5<br />
Verint enhancements . . . . . . . . . . . . . . . . 5<br />
AutoVu LPR enhancements . . . . . . . . . . . . . . . 5<br />
New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> . . . . . . . . . 6<br />
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1 . . . . . . . . . . . . . 14<br />
<strong>Security</strong> Desk enhancements . . . . . . . . . . . . . . . 14<br />
Plugin enhancements . . . . . . . . . . . . . . . . . 14<br />
AutoVu LPR enhancements . . . . . . . . . . . . . . . 15<br />
New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1 . . . . . . . . . 15<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version<br />
EN.500.001-V<strong>5.1</strong>.C2(1)<br />
v
|<br />
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA . . . . . . . . . . . . . . 16<br />
General product enhancements . . . . . . . . . . . . . . . 16<br />
Config Tool enhancements . . . . . . . . . . . . . . . . 18<br />
<strong>Security</strong> Desk enhancements . . . . . . . . . . . . . . . 18<br />
Omnicast video surveillance enhancements . . . . . . . . . . . . 19<br />
Synergis access control enhancements . . . . . . . . . . . . . 20<br />
AutoVu LPR enhancements . . . . . . . . . . . . . . . . 21<br />
New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA . . . . . . . . . 21<br />
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong>. . . . . . . . . . . . . 25<br />
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1. . . . . . . . . . . . . 29<br />
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA . . . . . . . . . . . . . 31<br />
Known issues . . . . . . . . . . . . . . . . . . . . 34<br />
Limitations. . . . . . . . . . . . . . . . . . . . . 40<br />
System requirements . . . . . . . . . . . . . . . . . . 45<br />
Supported video units . . . . . . . . . . . . . . . . . . 46<br />
Supported HID units . . . . . . . . . . . . . . . . . . 47<br />
HID unit compatibility . . . . . . . . . . . . . . . . 47<br />
HID interface module program and EEPROM . . . . . . . . . . 47<br />
Supported intrusion detection units . . . . . . . . . . . . . . 48<br />
Supported Bosch intrusion detection devices . . . . . . . . . . . 48<br />
Supported Honeywell Galaxy intrusion detection devices . . . . . . . . 49<br />
Supported languages . . . . . . . . . . . . . . . . . . 50<br />
Upgrading from earlier versions of <strong>Security</strong> <strong>Center</strong> . . . . . . . . . . 51<br />
Upgrading from Synergis 2.1 . . . . . . . . . . . . . . . . 51<br />
Migrating from Omnicast . . . . . . . . . . . . . . . . . 51<br />
Migrating from AutoVu 4.3 . . . . . . . . . . . . . . . . 51<br />
<strong>Security</strong> <strong>Center</strong> compatibility . . . . . . . . . . . . . . . . 52<br />
<strong>Security</strong> <strong>Center</strong> backward compatibility . . . . . . . . . . . . . 53<br />
<strong>Security</strong> <strong>Center</strong> backward compatibility requirements . . . . . . . . . 53<br />
Backward compatibility between <strong>Security</strong> <strong>Center</strong> roles . . . . . . . . . 53<br />
Backward compatibility with <strong>Security</strong> Desk tasks . . . . . . . . . . 54<br />
Omnicast compatibility . . . . . . . . . . . . . . . . . 58<br />
Sharp model compatibility. . . . . . . . . . . . . . . . . 59<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version<br />
EN.500.001-V<strong>5.1</strong>.C2(1)<br />
vi
<strong>Security</strong> <strong>Center</strong> Mobile compatibility . . . . . . . . . . . . . . 60<br />
About the documentation in this release . . . . . . . . . . . . . 61<br />
Documents added . . . . . . . . . . . . . . . . . . 61<br />
Documentation languages . . . . . . . . . . . . . . . . 61<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version<br />
EN.500.001-V<strong>5.1</strong>.C2(1)<br />
vii
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> <strong>Release</strong> <strong>Notes</strong><br />
<strong>Security</strong> <strong>Center</strong> is the unified security platform that seamlessly blends <strong>Genetec</strong>'s IP security<br />
and safety systems within a single innovative solution. The systems unified under <strong>Security</strong><br />
<strong>Center</strong> include <strong>Genetec</strong>'s Omnicast IP video surveillance system, Synergis IP access control<br />
system, and AutoVu IP license plate recognition (LPR) system.<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> is a service release that improves the reliability and performance of<br />
<strong>Security</strong> <strong>Center</strong>. This document describes the release in detail, and provides late-breaking<br />
or other information that supplements the <strong>Genetec</strong> <strong>Security</strong> <strong>Center</strong> documentation.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version<br />
EN.500.001-V<strong>5.1</strong>.C2(1)<br />
viii
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
This section includes the following topics:<br />
• "<strong>Security</strong> Desk enhancements" on page 1<br />
• "Synergis access control enhancements" on page 1<br />
• "Omnicast video surveillance enhancements" on page 1<br />
• "AutoVu LPR enhancements" on page 5<br />
• "New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong>" on page 6<br />
<strong>Security</strong> Desk enhancements<br />
• Digital zoom presets. When applying digital zoom to a camera image in a <strong>Security</strong><br />
Desk tile, you can create presets for digital zoom positions. This feature is very useful<br />
when using a megapixel camera.<br />
Synergis access control enhancements<br />
• Export cardholder and visitor pictures. In the Cardholder management and Visitor<br />
managements tasks, you can export cardholder and visitor pictures to your computer in<br />
JPEG, PNG, or bitmap format.<br />
• HID VertX and Edge firmware compatibility. <strong>Security</strong> <strong>Center</strong> is now compatible with<br />
HID unit firmware version 2.2.7.149.<br />
Omnicast video surveillance enhancements<br />
• Camera tile option. There is a new video option in <strong>Security</strong> Desk called Camera tile,<br />
that allows you to change how cameras are shown in tiles. You can choose to display the<br />
full camera image, or to fill the tile with the image (crop the image). This feature is very<br />
useful when using a megapixel camera.<br />
• Audio mode option. There is a new video option in <strong>Security</strong> Desk called Audio mode,<br />
that allows you to select full-duplex or half-duplex audio mode. Full-duplex allows you<br />
to talk and listen at the same time. Half-duplex requires you to switch between talking<br />
and listening. Half-duplex mode is necessary when two units are connected, or when<br />
audio must be controlled through digital inputs.<br />
• IPv6 support. <strong>Security</strong> <strong>Center</strong> now supports the Internet Protocol version 6 (IPv6) for<br />
video streaming. This protocol uses 128-bit addresses, while IPv4 uses 32-bit addresses.<br />
Therefore, IPv6 allows for more devices and users on the Internet, and enhances data<br />
transmission between IP networks.<br />
• H.264 CABAC streaming. Software motion detection is now supported using H.264<br />
CABAC streaming.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 1<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
• H.264 motion detection enhancements. H.264 video streaming has been enhanced<br />
(for example, H.264 streams now support main and high video profiles, interlaced<br />
video, lossless video, and 8x8/4x4 block-size transform coding). To take advantage of<br />
these enhancements, you need to reconfigure the advanced motion detection settings<br />
for H.264 units already on your system if you are upgrading to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong>.<br />
For more information about how to configure the advanced motion detection settings,<br />
see “Advanced H.264 Motion Detection” in the <strong>Security</strong> <strong>Center</strong> Administrator Guide.<br />
• Audio out anti-jitter buffer. An audio out anti-jitter buffer is implemented for Axis,<br />
Sony, and Verint extensions in <strong>Security</strong> <strong>Center</strong>. With this feature, the Archiver buffers<br />
the audio packet before sending it to the unit's audio decoder, eliminating any jittering<br />
that may occur. For more information on enabling this feature, see the <strong>Security</strong> <strong>Center</strong><br />
Video Unit Configuration Guide.<br />
Arecont enhancements<br />
• New exposure settings. There are new exposure settings available for Arecont cameras<br />
in the Config Tool: Sharpness, exposure reference, illumination mode, blue, red, day/<br />
night settings, and low light modes.<br />
• Flicker control. The flicker control option is now supported for Arecont units, which<br />
prevents intermittent flashes of light caused by fluctuations in voltage.<br />
• Image rotation. Arecont camera orientation can now be changed in Config Tool.<br />
For more information about configuring these Arecont unit and camera settings, see the<br />
<strong>Security</strong> <strong>Center</strong> Video Unit Configuration Guide.<br />
ATEME enhancements<br />
• ATEME VSS-441-R4TE support. ATEME VSS-441-R4TE units are supported in<br />
<strong>Security</strong> <strong>Center</strong>. Additional configuration is required on the unit’s Web page before<br />
adding the unit in <strong>Security</strong> <strong>Center</strong>. For more information, see the <strong>Security</strong> <strong>Center</strong> Video<br />
Unit Configuration Guide.<br />
Axis enhancements<br />
• Profile selection. Axis H.264 cameras now support main and baseline profile selection.<br />
For more information, see the <strong>Security</strong> <strong>Center</strong> Video Unit Configuration Guide.<br />
• Edge storage 2.0 support. The edge storage 2.0 feature is now supported on Axis units<br />
with firmware 5.40.4 and later.<br />
• Video quality and resolution enhancements. In Video tab of Config Tool, the default<br />
Resolution for Axis H.264 cameras was changed to 2560x1920, and the default video<br />
Quality was changed to 70%.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 2<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Basler enhancements<br />
• Basler BIP2 unit integration improvements. Basler BIP2 units have been integrated<br />
to the Basler Driver under the Generic Plus extension. As a result of these enhancements,<br />
you can now specify the stream usage, adjust the frame rate, and configure the<br />
input/output pins for Basler BIP2 units in <strong>Security</strong> <strong>Center</strong>. Hardware motion detection<br />
is also supported.<br />
Additional configuration is required on the unit’s Web page before adding the unit in<br />
<strong>Security</strong> <strong>Center</strong>. For more information, see the <strong>Security</strong> <strong>Center</strong> Video Unit Configuration<br />
Guide.<br />
Bosch enhancements<br />
• Bosch MPEG-2 video unit support. MPEG-2 streaming is now supported on Bosch<br />
IP cameras and video encoders.<br />
• Firmware enhancements. Bosch firmware 5.0 and 5.5 are now supported in <strong>Security</strong><br />
<strong>Center</strong>.<br />
• AAC audio support. The AAC audio format is now supported on Bosch units with<br />
firmware 5.0 and later.<br />
• VRM version 2.2. Bosch VRM version 2.2 is now supported in <strong>Security</strong> <strong>Center</strong>.<br />
• Bit rate values increased. In the Video tab of Config Tool, the highest Bit rate slider<br />
value for Bosch cameras was changed to 10, 000 kbps, and the highest Maximum bit<br />
rate slider value was changed to 20, 000 kbps.<br />
• IVA people counter support. <strong>Security</strong> <strong>Center</strong> now supports the Bosch IVA (Intelligent<br />
Video Analytics) people counter feature. This feature allows you to configure your unit<br />
to send events to <strong>Security</strong> Desk when the people count changes for a specific zone. The<br />
events are then stored and can be queried. To use this feature, your Bosch unit must<br />
have the following:<br />
• IVA compatibility<br />
• IVA valid license<br />
• Firmware 5.50 or later<br />
For more information about configuring this feature, see the documentation for your<br />
Bosch IVA unit.<br />
Canon enhancements<br />
• Canon VB-C60 and VB-C500D support. Canon VB-C60 and VB-C500D units are<br />
now supported in <strong>Security</strong> <strong>Center</strong>. Additional configuration is required to use these<br />
units in <strong>Security</strong> <strong>Center</strong>, and to control the PTZ of VB-C60 units. For more information,<br />
see the <strong>Security</strong> <strong>Center</strong> Video Unit Configuration Guide.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 3<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
<strong>Genetec</strong> Protocol enhancements<br />
• AAC (Advanced Audio Coding) format support. The <strong>Genetec</strong> Protocol now supports<br />
the AAC format.<br />
Interlogix enhancements<br />
• VisioWave driver support. The Interlogix VisioWave driver, which can control multiple<br />
Interlogix VisioWave encoders, is now supported in <strong>Security</strong> <strong>Center</strong>. VisioWave<br />
encoders support PTZ controls and the Wavelet video format in <strong>Security</strong> <strong>Center</strong>. This<br />
integration also enables support for multiple PTZ motors in the Generic Plus extension.<br />
For more information about configuring Interlogix units controlled by the Visio-<br />
Wave driver, see the <strong>Security</strong> <strong>Center</strong> Video Unit Configuration Guide.<br />
• Interlogix unit support. Interlogix MPEG-4 units and DVMRe/Storesafe units are<br />
now supported in <strong>Security</strong> <strong>Center</strong>.<br />
Mavix enhancements<br />
• MediaRacer 150 support. <strong>Security</strong> <strong>Center</strong> now supports the Mavix MediaRacer 150.<br />
Additional configuration is required on the unit’s Web page before adding the unit in<br />
Omnicast. For more information, see the <strong>Security</strong> <strong>Center</strong> Video Unit Configuration<br />
Guide.<br />
Panasonic enhancements<br />
• Panasonic auto-pan feature. Panasonic WV-SW395 (DG-SW395) and WV-SW396<br />
(DG-SW396) units now support the auto-pan feature in <strong>Security</strong> Desk. For information<br />
about configuring this feature, see the <strong>Security</strong> <strong>Center</strong> Video Unit Configuration<br />
Guide.<br />
• Panasonic 3 megapixel camera support. Panasonic 3 megapixel cameras are now supported<br />
in <strong>Security</strong> <strong>Center</strong>, which can stream at a resolution of 3 Megapixels in H.264.<br />
To enable an image quality of 3 Megapixels, the 3 Megapixel mode must be configured<br />
on the unit’s Web page. For more information, see the <strong>Security</strong> <strong>Center</strong> Video Unit Configuration<br />
Guide.<br />
• PelcoD-Zoom only protocol. This protocol is now available in <strong>Security</strong> <strong>Center</strong> to support<br />
the Panasonic WV-CZ392 analog camera.<br />
• Cropping function. <strong>Security</strong> <strong>Center</strong> now supports the cropping function available on<br />
the following Panasonic units:<br />
• WV-SP508<br />
• WV-SP509<br />
• WV-SW558<br />
• WV-SW558<br />
The Panasonic cropping feature must be configured on the unit’s Web page. For more<br />
information, see your Panasonic unit’s documentation<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 4<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Pelco enhancements<br />
• Sarix H.264 multicast streaming. <strong>Security</strong> <strong>Center</strong> now supports H.264 multicast<br />
streaming on Sarix units with firmware 1.8.2 or later.<br />
Sanyo enhancements<br />
• Sanyo motion detection. Sanyo units now support software motion detection in <strong>Security</strong><br />
<strong>Center</strong>.<br />
Sony enhancements<br />
• Sony edge recording and trickling. Sony cameras with firmware 1.61 and later now<br />
support video trickling in <strong>Security</strong> <strong>Center</strong> through the Sony Edge storage feature. For<br />
more information about configuring this feature, see the <strong>Security</strong> <strong>Center</strong> Video Unit<br />
Configuration Guide.<br />
Verint enhancements<br />
• S1808e video signal status improvement. Signal recovered and signal lost events are<br />
now logged in <strong>Security</strong> <strong>Center</strong> for the S1808e encoder when the unit comes back<br />
online.<br />
• Verint firmware enhancements.<br />
AutoVu LPR enhancements<br />
• Firmware 2.2.5.284.100729 is now supported with Verint S1801 and S1802 encoders<br />
in <strong>Security</strong> <strong>Center</strong>.<br />
• Firmware 2.2.5.273.99788 is now supported with Verint S1808 and S1816 encoders<br />
in <strong>Security</strong> <strong>Center</strong>.<br />
• <strong>5.1</strong> <strong>SR2</strong> supports all AutoVu configurations. All four AutoVu LPR configurations are<br />
supported in <strong>5.1</strong> <strong>SR2</strong>:<br />
• Law Enforcement<br />
• City Parking Enforcement (with or without Wheel Imaging)<br />
• University Parking Enforcement<br />
• MLPI (Mobile License Plate Inventory).<br />
• Simplified AutoVu configuration. To simplify the configuration of an AutoVu system,<br />
many of the common AutoVu-related tasks in Config Tool are pre-configured based on<br />
your specific <strong>Security</strong> <strong>Center</strong> license.<br />
Here are some examples:<br />
• The LPR Manager root folder is automatically created on your computer.<br />
• The Config Tool user interface includes only the information you need for your particular<br />
configuration. For example, if you're a Law Enforcement user, you won't see<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 5<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
tabs or buttons related to City Parking Enforcement, such as Overtime rules, Permit<br />
Restrictions, and so on.<br />
• Several common New wanted categories are available: Amber, Stolen, Felon, Person<br />
of Interest, and BOLO (be on the lookout).<br />
• Several common hit reject reasons are available: Police vehicle, Duplicate, Already<br />
processed, Misread, Other.<br />
• An AutoVu user, user group, and privilege template are available.<br />
This simplified configuration will help you get an AutoVu system up and running faster<br />
and more efficiently than in previous versions.<br />
• Search feature added to the Hotlist and permit editor. Intended for hotlists and permit<br />
lists with 100,000 entries or less, you can now search for a full or partial license<br />
plate in the Hotlist and permit editor.<br />
• Force Patroller password change. You can force Patroller users to change their passwords<br />
when they first log on. This simplifies AutoVu configuration because you could<br />
set the same initial password for all Patroller users in a user group. When each user logs<br />
on to Patroller for the first time, Patroller will ask for a new personal password.<br />
• Increased database retention periods. You can set the LPR Manager's route, hit, read,<br />
and event retention periods to a maximum of 2000 days (5.4 years). In previous versions<br />
of <strong>Security</strong> <strong>Center</strong>, retention periods were limited to 999 days (2.7 years).<br />
• Native resolution of license plates in reports. When you run a Hits report in <strong>Security</strong><br />
Desk, the license plate image is now displayed in its native resolution. This results in a<br />
better quality image when you print the hit.<br />
• Hotlist matching supported for Japanese plates. AutoVu’s hotlist matching mechanism<br />
supports Japanese license plates. Japanese plates consist of four types of characters:<br />
small and large digits, Kanji, and Hiragana. The LPR context reads all characters,<br />
and matches small, large, and Hiragana characters to hotlists. This feature is available<br />
for both fixed and mobile applications.<br />
New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
The following video units are now supported in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong>. For each unit<br />
model, the Archiver extension and certification level is listed.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 6<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
NOTE Some of the supported video units require additional configuration before they can<br />
be added in <strong>Security</strong> <strong>Center</strong>, or for their unit features to work in <strong>Security</strong> <strong>Center</strong>. For more<br />
information about these configuration steps, see the <strong>Security</strong> <strong>Center</strong> Video Unit<br />
Configuration Guide. The <strong>latest</strong> version of this document is available at:<br />
http://downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<strong>SR2</strong>/<strong>Security</strong>_<strong>Center</strong>/<br />
EN.<strong>Security</strong>%20<strong>Center</strong>%20Video%20Unit%20Configuration%20Guide%20<strong>5.1</strong>%20<strong>SR2</strong>.pdf.<br />
Manufacturer Unit models Extension Certification<br />
ACTi<br />
KCM-7111<br />
KCM-7211<br />
KCM-7311<br />
KCM-3211<br />
KCM-3311<br />
KCM-3911<br />
KCM-5111<br />
KCM-5211<br />
KCM-5211E<br />
KCM-5311<br />
KCM-5311E<br />
KCM-5401<br />
KCM-5511<br />
ACTi<br />
Supported by design<br />
American<br />
Dynamics<br />
• Illustra 400 Box camera<br />
• Illustra 400 Fixed Dome<br />
• Illustra 600<br />
Generic Plus (ONVIF)<br />
Tested by Partner<br />
Arecont • AV1115<br />
• AV2125<br />
• AV10115<br />
• AV20185<br />
• AV20365<br />
• AV1125<br />
• AV1255<br />
• AV2115<br />
• AV2255<br />
• AV3255<br />
• AV5255<br />
• D4F-AV1115<br />
• D4S-AV1115<br />
• D4F-AV2115<br />
• D4S-AV2115<br />
Arecont<br />
Arecont<br />
Certified<br />
Supported by design<br />
ATEME VSS-441-R4TE Generic Plus Certified<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 7<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Manufacturer Unit models Extension Certification<br />
Axis<br />
M1143-L<br />
M1144-L<br />
M7010<br />
M7014<br />
P3353<br />
P3354<br />
P3363-V<br />
P3363-VE<br />
P3364-V<br />
P3364-VE<br />
P3367-V<br />
P3367-VE<br />
P5544<br />
P7210<br />
P7214<br />
P7224<br />
P8513<br />
P8514<br />
Q1604<br />
Q1604-E<br />
Q1602<br />
Q1602-E<br />
Q1922<br />
Q1922-E<br />
Q7424-R<br />
Axis<br />
Certified<br />
Basler<br />
BIP2 D1000c-dn<br />
BIP2 D1300c-dn<br />
BIP2 D1920c-dn<br />
Generic Plus<br />
Certified<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 8<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Manufacturer Unit models Extension Certification<br />
Bosch<br />
NBN-832<br />
VideoJet X20-XF-E<br />
VideoJet X40-XF-E<br />
Bosch<br />
Certified<br />
NBC-255-W<br />
NBC 265-W<br />
NDC-225-PI<br />
NDC-274-P<br />
NDN-822-P<br />
NDN-265-PIO<br />
NEI 30 IR<br />
NTC-255-PI<br />
NTC-265-PI<br />
MIC 550 IP<br />
REG 1.5 IP<br />
REG L2<br />
VIP X1 XF E<br />
Autodome Junior HD Fixed<br />
G5 AutoDome 700<br />
NDN-832<br />
VOT-320V<br />
Bosch<br />
Supported by design<br />
Canon<br />
VB-C60<br />
VB-C500D<br />
Generic<br />
Certified<br />
Dahua<br />
Technology<br />
IPC-HF3500<br />
IPC-HF3300<br />
IPC-HFW3300<br />
IPC-HFW3300C<br />
IPC-HDBW3300<br />
IPC-HDB3300<br />
IPC-HF3200<br />
IPC-HF3211<br />
IPC-HDB3200C<br />
IPC-HF3110<br />
IPC-HFW3110<br />
IPC-HDB3110<br />
IPC-HDBW3110<br />
IPC-HF3100<br />
IPC-HD2100<br />
IPC-HFW2100<br />
IPC-HF2100<br />
<strong>Genetec</strong><br />
Tested by partner<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 9<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Manufacturer Unit models Extension Certification<br />
FLIR (ONVIF) D-313<br />
D-324<br />
D-334<br />
D-348<br />
D-618<br />
D-645<br />
F-112<br />
F-117<br />
F-124<br />
F-304<br />
F-307<br />
F-313<br />
F-324<br />
F-334<br />
F-606<br />
F-610<br />
F-612<br />
F-618<br />
F-625<br />
F-645<br />
PT-112<br />
PT-117<br />
PT-124<br />
PT-304<br />
PT-307<br />
PT-313<br />
PT-324<br />
PT-348<br />
PT-606<br />
PT-610<br />
PT-612<br />
PT-618<br />
PT-625<br />
PT-645<br />
FLIR D-625<br />
F-348<br />
HRC-E<br />
HRC-S<br />
HRC-U<br />
HRC-X<br />
PT-334<br />
Generic Plus (ONVIF)<br />
Generic Plus (ONVIF)<br />
Supported by design<br />
Tested by partner<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 10<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Manufacturer Unit models Extension Certification<br />
HW Group<br />
HWg-Juno-008<br />
HWg-Juno-1200<br />
<strong>Genetec</strong><br />
Supported by design<br />
Interlogix VisioWave Discovery 300<br />
VisioWave Evolution<br />
HD2809<br />
DVMRe Triplex 10CT<br />
DVMRe Triplex 10CTII<br />
DVMRe Triplex 16CT<br />
DVMRe Triplex 16CTII<br />
StoreSafe Pro<br />
StoreSafe Pro II<br />
Legend IP<br />
SymDec1<br />
SymDec4<br />
SymDec16<br />
SymNet<br />
SymSafe Pro 4<br />
SymSafe Pro 8<br />
SymSafe Pro 16<br />
SymSafe 4<br />
SymSafe 8<br />
SymSafe 16<br />
SymVeo<br />
Generic Plus<br />
GE DVMRe<br />
GE MPEG-4<br />
Certified<br />
Certified<br />
Certified<br />
Mavix Media Racer 150 Generic Plus<br />
(Universal)<br />
Supported by design<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 11<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Manufacturer Unit models Extension Certification<br />
Panasonic<br />
BL-VT164<br />
WV-SF132<br />
WV-SF135<br />
WV-SF539<br />
WV-SW155<br />
WV-SW152<br />
WV-SW396<br />
WV-SW172<br />
WV-SW175<br />
WV-SW314<br />
WV-SW316<br />
WV-SW316L<br />
WV-SW559<br />
Panasonic<br />
Certified<br />
BB-HCM705<br />
BB-HCM735<br />
BB-HCM701<br />
BB-HCM715<br />
BB-SW175<br />
BB-SW172<br />
BB-ST165<br />
BB-ST162<br />
BB-SW174W<br />
DG-SF539<br />
DG-SP509<br />
DG -SW316<br />
DG -SW314<br />
DG-SW316L<br />
DG-SW559<br />
WV-SF538<br />
WV-SF548<br />
WV-SF549<br />
WV-SP508<br />
WV-SP509<br />
WV-ST162<br />
WV-ST165<br />
WV-SW174W<br />
WV-SW558<br />
DG-SF135<br />
DG-SW155<br />
DG-SW152<br />
WV-SC386<br />
Panasonic<br />
Supported by design<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 12<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Manufacturer Unit models Extension Certification<br />
Pelco Sarix ESTI3 series Pelco Certified<br />
Sarix TI3 series Pelco Supported by design<br />
Siqura C-60 <strong>Genetec</strong> Certified<br />
Sony<br />
SNC-EB520<br />
SNC-EM520<br />
SNC-EM521<br />
SNC-EP550<br />
SNC-ER550<br />
Sony<br />
Certified<br />
SNC-EP521<br />
SNC-ER521<br />
Sony<br />
Supported by design<br />
Vicon<br />
V960<br />
V961<br />
V962<br />
<strong>Genetec</strong><br />
Tested by Partner<br />
VideoIQ<br />
VIQ-E1050<br />
VIQ-HD-CRD250<br />
<strong>Genetec</strong><br />
Supported by design<br />
VIQ-CID100<br />
VIQ-CID116<br />
VIQ-CID150<br />
VIQ-CRD200<br />
VIQ-E1000<br />
VIQ-E1016<br />
VIQ-HD-CRD225<br />
VIQ-HD-CRD200<br />
<strong>Genetec</strong><br />
Tested by partner<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 13<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1<br />
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1<br />
This section includes the following topics:<br />
• "<strong>Security</strong> Desk enhancements" on page 14<br />
• "Plugin enhancements" on page 14<br />
• "AutoVu LPR enhancements" on page 15<br />
• "New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1" on page 15<br />
<strong>Security</strong> Desk enhancements<br />
Plugin enhancements<br />
• PTZ-in-tile enhancements. When using PTZ-in-tile with PTZ cameras that do not<br />
support Direct XYZ positioning, you can now click anywhere inside the tile to move<br />
the camera in that direction. Previously, you had to click the blue dot in the center of<br />
the tile, and then drag the camera to move it in that direction.<br />
• Video overlay in tiles. You can display or hide the video overlay controls in <strong>Security</strong><br />
Desk tiles. From the Visual options page in the Options dialog box, select or clear the<br />
Display overlay video controls option.<br />
• OnGuard plugin. <strong>Security</strong> <strong>Center</strong> now supports the OnGuard plugin, an access control<br />
plugin that allows OnGuard® access control system to be seamlessly integrated into<br />
<strong>Security</strong> <strong>Center</strong>. The OnGuard plugin allows you to:<br />
• Create links between OnGuard-controlled devices, door, and input points, and the<br />
cameras monitoring them in <strong>Security</strong> <strong>Center</strong>.<br />
• View live and playback video associated to OnGuard access control events.<br />
• Acknowledge OnGuard alarms in <strong>Security</strong> Desk.<br />
• Search for OnGuard access control event history.<br />
• Video Translator plugin. The Video Translator plugin 3.0 is designed for OnGuard ®<br />
access control systems. It allows <strong>Security</strong> <strong>Center</strong> cameras to be viewed from the System<br />
Administrator, Alarm Monitoring and Video Viewer OnGuard applications. The Video<br />
Translator plugin allows you to:<br />
• View live and archived <strong>Security</strong> <strong>Center</strong> video.<br />
• Control <strong>Security</strong> <strong>Center</strong> PTZ cameras.<br />
• Export <strong>Security</strong> <strong>Center</strong> G64 video files with watermarking.<br />
• Receive <strong>Security</strong> <strong>Center</strong> video events in OnGuard.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 14<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1<br />
AutoVu LPR enhancements<br />
• Tab delimiters. The TAB key can now be used as a delimiter for fields in hotlist text<br />
files.<br />
• New and enhanced contexts. License plate recognition is now available, or has been<br />
improved, for the following license plates:<br />
• New York. Improved reading rates for flat plates.<br />
• Vietnam. Single and double-line Vietnamese plates can now be read.<br />
New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1<br />
There are no new supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 15<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
This section includes the following topics:<br />
• "General product enhancements" on page 16<br />
• "Config Tool enhancements" on page 18<br />
• "<strong>Security</strong> Desk enhancements" on page 18<br />
• "Omnicast video surveillance enhancements" on page 19<br />
• "Synergis access control enhancements" on page 20<br />
• "AutoVu LPR enhancements" on page 21<br />
• "New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA" on page 21<br />
General product enhancements<br />
• Installer enhancements. Hotfixes for <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> and later can now be<br />
installed using a hotfix installer. Also, the <strong>Security</strong> <strong>Center</strong> installer now creates the necessary<br />
firewall rules for its applications.<br />
• Forward and backward compatibility. <strong>Security</strong> <strong>Center</strong> Directory can connect to different<br />
versions of <strong>Security</strong> <strong>Center</strong> client and server applications, making it easier to<br />
upgrade large systems. A difference of up to two minor versions forwards and two<br />
minor versions backwards is supported.<br />
• High Availability Directory. Includes the following features:<br />
• Directory failover. If a Directory server fails, a standby server can automatically<br />
replace it.<br />
• Load balancing. The Directory can be spread across multiple servers to share the<br />
workload.<br />
• View live and playback video even if you lose connection to the Directory.<br />
• Active Directory enhancements.<br />
• Support for multiple domains. <strong>Security</strong> <strong>Center</strong> can now connect to more than one<br />
Active Directory domain (designed to support up to 10).<br />
• Custom Field synchronization. You can now synchronize attributes from the Active<br />
Directory to custom fields in <strong>Security</strong> <strong>Center</strong>. This is supported for users, cardholders,<br />
user groups and cardholder groups.<br />
• Health monitoring. You can now monitor the health of your system using the Health<br />
Monitoring role. It includes the following features:<br />
• Monitors the health of the entire system.<br />
• Logs health events in the Windows Event Log that have been triggered by <strong>Security</strong><br />
<strong>Center</strong> services, roles, agents, units, and client applications.<br />
• Provides real time alerts as well as detailed historical reporting.<br />
• Calculates statistics within specified time frame (hours, days, months).<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 16<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
• Calculates availability for clients, server, and video/access/LPR units.<br />
• Receives events that are sent directly from various roles and entities.<br />
This features also allows you to view health events in the Health History report, and<br />
retrieve health events via the SDK.<br />
• Move units between manager roles. If you are using multiple manager roles spread<br />
across your network, you can now easily move units between those managers with the<br />
Move Unit tool.<br />
• AutoVu example. If you have a dedicated LPR Manager for each police station precinct<br />
in a city, and a particular patroller unit is transferred to another precinct, you<br />
can use the Move Unit tool to easily move the Patroller unit to the new LPR Manager<br />
without losing data.<br />
• Synergis example. After an office expansion you may want one Access Manager to<br />
control all access control units (door controllers) on one floor and another Access<br />
Manager to control all units on a different floor. You can use the Move Unit tool to<br />
move a door controller to the new Access Manager without losing data.<br />
• Plan Manager. Plan Manager is an advanced map-based interface for <strong>Security</strong> <strong>Center</strong>.<br />
It allows you to create interactive environments from maps or floor plans for easier<br />
monitoring and navigation. Live video, doors, alarms, inputs/outputs, PTZ motors, and<br />
more can be monitored and controlled from the Plan Manager interface in <strong>Security</strong><br />
Desk.<br />
• RF Code Asset Management plugin. <strong>Security</strong> <strong>Center</strong> now supports the RF Code Asset<br />
Management plugin, which enables you to do the following:<br />
• Synchronize RF Code assets with <strong>Security</strong> <strong>Center</strong> assets (a new entity).<br />
• Monitor asset-related events and activities live.<br />
• Synchronize RF Code alerts with <strong>Security</strong> <strong>Center</strong> alarms automatically.<br />
• Acknowledge alarms in <strong>Security</strong> <strong>Center</strong>, which will clear alerts in the RF Code solution.<br />
• View video tied to asset-related activity and alerts.<br />
• Perform real-time tracking of asset locations using the Asset Management Inventory<br />
reporting task.<br />
• View events associated to tracked assets using the Asset Activity reporting task.<br />
• Honeywell Galaxy panel integration. <strong>Security</strong> <strong>Center</strong> now supports the Honeywell<br />
Galaxy control panels, which enables you to do the following:<br />
• Map inputs and devices connected to the alarm panel to intrusion detection areas in<br />
<strong>Security</strong> <strong>Center</strong>.<br />
• Monitor the connection between the <strong>Security</strong> <strong>Center</strong> Server and the alarm panel<br />
using the heartbeat feature.<br />
• Create event-to-actions for events that are sent from the alarm panel.<br />
• Create custom events, which can be monitored in <strong>Security</strong> Desk.<br />
• Monitor intrusion detection area state changes in real time in <strong>Security</strong> Desk<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 17<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
• Receive events and alarms from the alarm panel, and monitor them in <strong>Security</strong><br />
Desk.<br />
• Arm and disarm the intrusion detection areas defined on your intrusion panels in<br />
<strong>Security</strong> Desk.<br />
• Receive live reports on input state changes in <strong>Security</strong> Desk.<br />
• Create reports on events received from the alarm panel.<br />
• Trigger intrusion alarms on intrusion detection areas or intrusion detection units in<br />
<strong>Security</strong> Desk.<br />
• Generate detailed activity reports on intrusion detection areas or intrusion detection<br />
units.<br />
• Language support. Hebrew, Hungarian, Polish, Thai, and Traditional Chinese are now<br />
supported in <strong>Security</strong> <strong>Center</strong>.<br />
Config Tool enhancements<br />
• Task-based interface. To improve usability and ensure consistency with <strong>Security</strong> Desk,<br />
the Config Tool is now task-based. It’s redesigned home page lists the available tasks,<br />
favorites, and more.<br />
• New tasks available. The following tasks are now available in the Config Tool: Role<br />
View, Network View, Logical View, System, <strong>Security</strong>, Access Control, and LPR.<br />
• <strong>Security</strong> Desk tasks are now available in Config Tool. Cardholder Management, Credential<br />
Management, and all Maintenance related tasks.<br />
• New reports available. Health Statistics, and Health History reports.<br />
<strong>Security</strong> Desk enhancements<br />
• New Home page. The <strong>Security</strong> Desk’s redesigned home page lists the available tasks<br />
and recently used tasks, and allows you to access your saved private and public tasks,<br />
the Tools menu, the About menu, and the Options dialog box.<br />
• Workspace layout enhancements. The dashboard is now located on the right hand<br />
side of the interface.Video timelines have been moved from the playback widget, to<br />
each display tile.<br />
• New reports available. Health statistics, Asset management and Forensic search<br />
reports.<br />
• Health warnings in notification tray. Health warnings now appear in the notification<br />
tray. If you double-click the icon, it opens the Health History report.<br />
• New custom field filters for reports. There is now a custom fields filter in the Cardholder<br />
configuration and Credential configuration reports.<br />
• Digital PTZ zoom support. In-tile digital zoom is now supported.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 18<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
• Event priority enhancements. Event priorities have been replaced by background colors<br />
that are visible the event list and display tiles. To easily distinguish critical events<br />
from less important events, and ensure that critical events stand out, you can assign different<br />
colors to different events.<br />
• Out of process media decoding. The media decoding process now can be executed<br />
outside of the application process, which increases the overall performance of the client<br />
applications.<br />
• Quick archives. When viewing live video, you can quickly play back recordings from<br />
the same camera by browsing date/time and thumbnail previews.<br />
• Two ways to send tasks. There are now two ways to send a task to other <strong>Security</strong> Desk<br />
applications:<br />
• Previous method: Right-click on a task tab to send the task to a user or monitor. A<br />
pop up message appears on the remote workstation asking if the recipient accepts<br />
the sent task.<br />
• New method: Send task is a system action which can be linked to an event (like<br />
alarm triggered), or executed manually through a hot action.<br />
This new method does not produce a dialog asking if the sent task is accepted,<br />
which is useful for video walls. This method also includes the opposite command,<br />
Clear tasks, which removes tasks from a remote workstation.<br />
• Snapshot manager. The Snapshot manager performs some of the tasks that used to be<br />
available from the camera widget, such as delete, rename, or print snapshots, or send<br />
the snapshots by email. The camera widget in <strong>Security</strong> Desk now only has the Save<br />
snapshot button.<br />
Omnicast video surveillance enhancements<br />
• Uninterrupted video streaming. Video streams displayed in the <strong>Security</strong> Desk remain<br />
available even if the Directory or other critical roles become unavailable.<br />
• Video trickling. Video stored on edge devices can be transferred on a schedule, on<br />
demand or by an event, to the <strong>Security</strong> <strong>Center</strong> Archiver.<br />
• Auxiliary Archiver. Cameras can be recorded in a remote location, at different qualities,<br />
and on different schedules than the main Archiver.<br />
• Forensic search task. Ability to perform forensic (video analytic) search using Bosch<br />
video units with edge recording capabilities and IVA enabled.<br />
• AAC audio codec (Axis). Advanced Audio Coding (AAC) audio type, which provides<br />
better audio quality, is now supported on select video units such as Axis.<br />
• Support for watermarking with Bosch VRM. Watermarking verification is now possible<br />
for video recorded by the Bosch VRM using an external tool.<br />
• Support for video file protection with Bosch VRM. Video files recorded on a Bosch<br />
VRM can be protected for an indefinite protection period in <strong>Security</strong> Desk.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 19<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
• Support for ACTi MJPEG and H.264 in full extension. ACTi MJPEG and H.264<br />
video units now benefit from the full ACTi extension capabilities.<br />
• Bosch maximum bit rate. A maximum bit rate value can now be applied in the video<br />
quality configuration page for Bosch video units.<br />
• Axis - disable Bonjour discovery option. The default Bonjour network discovery protocol<br />
can now be disabled if desired for Axis video units.<br />
• Archive viewing limitation now granular to the minute. Users can be limited from<br />
viewing video archives based on a time value of days/hours/minutes. For example, an<br />
operator can be limited to playback recordings created within the last 2 days, 12 hours<br />
and 30 minutes. Any recording older this value cannot be played back by the operator.<br />
• Motion detection configuration utility. The level of sensitivity for a camera’s motion<br />
detection configuration can now be set using an Auto calibrate utility.<br />
• Support for Sentry 360. Sentry 360 H.264 units are now supported in <strong>Security</strong> <strong>Center</strong>.<br />
Use <strong>Security</strong> <strong>Center</strong> features to dewarp the 360 degree view.<br />
Synergis access control enhancements<br />
IMPORTANT Synergis Web Client is no longer available as of <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA. It is<br />
replaced by <strong>Security</strong> <strong>Center</strong> Web Client. For more information, see "<strong>Security</strong> <strong>Center</strong> Mobile<br />
compatibility" on page 60.<br />
• Global Cardholder Management enhancements. The Cardholder Management task<br />
now allows you to do the following:<br />
• Cardholders, cardholder groups, credentials, custom fields, and badge templates can<br />
be synchronized between sites from a central location.<br />
• Changes to a remote site can be synchronized with the central site, and with other<br />
remote sites.<br />
• Cardholders added centrally can be synchronized to remote sites.<br />
• One card can be used for all sites within a multi-campus, geographically dispersed<br />
organization.<br />
• Synchronize Active Directory custom fields for cardholders. Active Directory custom<br />
fields can be synchronized to cardholder custom fields. This avoids the need to<br />
manage custom fields separately from Active Directory, and extends the synchronization<br />
capabilities of the feature.<br />
• HID unit synchronization enhancements. This feature includes the following:<br />
• Enhanced synchronization between units and the Access Manager.<br />
• A unit that gets disconnected from the network or from the Access Manager will no<br />
longer force a full synchronization.<br />
• PIN visibility. You can now view the PIN code digits in Config Tool and <strong>Security</strong> Desk.<br />
The Show PIN settings is available in the Cardholder management task.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 20<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
AutoVu LPR enhancements<br />
• Patroller and Sharp live updates. You can use <strong>Security</strong> <strong>Center</strong> Config Tool to update<br />
services and send hotfixes to Patroller units and Sharp cameras, as well as send new<br />
sound files to be used for Patroller hit alerts. Both fixed and mobile Sharp cameras can<br />
be updated, with mobile Sharps receiving the updates through Patroller. You can<br />
update individual Patroller and Sharp units or update all units and services simultaneously.<br />
• Health monitoring available for LPR. You can now use <strong>Security</strong> <strong>Center</strong>’s health monitoring<br />
feature to monitor LPR-related information. This allows you to detect health<br />
issues early enough to avoid potential issues in the future. Health monitoring also provides<br />
you with information to help identify the cause of various health problems so you<br />
can prevent them from occurring again.<br />
• Server-configured Patroller options. You can configure several options for individual<br />
Patroller units directly from <strong>Security</strong> <strong>Center</strong> Config Tool. You can also use the Copy<br />
configuration tool to easily copy these settings to any or all of your other Patroller units:<br />
• Sound management settings. Configure Patroller to play a sound when reading a<br />
plate and/or generating a hit, and choose whether sounds should be played even<br />
when Patroller is minimized.<br />
• Acknowledgment buffer settings. Specify a buffer restriction that limits how many<br />
hits can remain unacknowledged (not accepted or rejected) before Patroller starts<br />
automatically rejecting all subsequent hits. You can also choose (by priority) which<br />
hotlists should comply with this restriction.<br />
• Hotlist hit delay settings. Specify a hit delay that tells Patroller to disregard multiple<br />
hits on the same plate for the duration of the delay. For example, if you set a delay of<br />
10 minutes, no matter how many times Patroller reads the same plate during those<br />
10 minutes, it will generate only one hit (assuming the plate is on a hotlist).<br />
• AutoVu Patroller enhancements. For AutoVu Patroller enhancements, see the AutoVu<br />
Patroller <strong>Release</strong> <strong>Notes</strong>. The <strong>latest</strong> version of this document is available at: http://<br />
downloads.genetec.com/<strong>Security</strong><strong>Center</strong>/<strong>5.1</strong>/SR1/AutoVu/EN.AutoVu%20Patroller%20<strong>Release</strong>%20<strong>Notes</strong>%20<strong>5.1</strong>%20SR1.pdf.<br />
• AutoVu hardware enhancements. For AutoVu hardware enhancements, see the AutoVu<br />
Hardware <strong>Release</strong> <strong>Notes</strong>. The <strong>latest</strong> version of this document is available at: http://<br />
downloads.genetec.com/<strong>Security</strong><strong>Center</strong>/<strong>5.1</strong>/SR1/AutoVu/EN.AutoVu%20Hardware%20<strong>Release</strong>%20<strong>Notes</strong>%20<strong>5.1</strong>%20SR1pdf.<br />
New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
The following video units are now supported in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA. For each unit<br />
model, the Archiver extension and certification level is listed.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 21<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
NOTE Some of the supported video units require additional configuration before they can<br />
be added in <strong>Security</strong> <strong>Center</strong>, or for their unit features to work in <strong>Security</strong> <strong>Center</strong>. For more<br />
information about these configuration steps, see the <strong>Security</strong> <strong>Center</strong> Video Unit<br />
Configuration Guide. The <strong>latest</strong> version of this document is available at:<br />
http://downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<strong>SR2</strong>/<strong>Security</strong>_<strong>Center</strong>/<br />
EN.<strong>Security</strong>%20<strong>Center</strong>%20Video%20Unit%20Configuration%20Guide%20<strong>5.1</strong>%20<strong>SR2</strong>.pdf.<br />
Manufacturer Unit Models Extension Certification<br />
ACTi • TCD-2100<br />
• TCM-1511<br />
• TCM-3401<br />
• TCM-3411<br />
• TCM-3511<br />
• TCM-4201<br />
• TCM-5601<br />
• TCM-5611<br />
• TCM-7411<br />
• TCM-7811<br />
ACTi<br />
Supported by design<br />
• TCD-2500 ACTi Certified<br />
Arecont • D4F-AV3115<br />
• D4F-AV5115<br />
• D4S-AV3115<br />
• D4S-AV5115<br />
Axis • M3114-VE<br />
• M5013<br />
• M5014<br />
• P5512<br />
• P5512-E<br />
• P5522<br />
• P5522-E<br />
• Q6032<br />
• Q6035<br />
• Q6035-E<br />
• Q7414<br />
Arecont<br />
Axis<br />
Supported by design<br />
Certified<br />
Bosch • Divar 700 Generic Plus Certified<br />
Canon • VB-M40<br />
• VB-M600D<br />
• VB-M600VE<br />
• VB-M700F<br />
Generic Plus (ONVIF)<br />
Tested by partner<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 22<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
Manufacturer Unit Models Extension Certification<br />
CBC • ZN-C1<br />
• ZN-C1M<br />
• ZN-C2M<br />
• ZN-D1A<br />
• ZN-D1MAP<br />
• ZN-D2MAP<br />
• ZN-DT1A<br />
• ZN-DT1MA<br />
• ZN-DT2MA<br />
CISCO • CIVS-IPC-2421<br />
• CIVS-IPC-2521V<br />
<strong>Genetec</strong> Protocol<br />
Generic<br />
Tested by partner<br />
Certified<br />
• CIVS-IPC-5010 Pelco Certified<br />
• CIVS-IPC-2621V Generic Supported by design<br />
• CIVS-IPC-2930<br />
• CIVS-IPC-5011<br />
Pelco<br />
Supported by design<br />
GSG<br />
International<br />
• KLIS IPCAM-1M-SD<br />
• KLIS IPCAM-2M-SD-H<br />
• KLIS IPCAM-IR1<br />
• KLIS IPCAM-1M-SD<br />
<strong>Genetec</strong> Protocol<br />
Tested by partner<br />
IQinVision • IQ832N<br />
• IQA32N<br />
• IQA33N<br />
• IQA35N<br />
• IQD30S<br />
• IQD31S<br />
• IQD32S<br />
• IQM32N<br />
• IQ832S<br />
• IQA30N<br />
• IQA31N<br />
• IQM30N<br />
• IQM30S<br />
• IQM31N<br />
• IQM31S<br />
• IQM32S<br />
IQEye<br />
IQEye<br />
Certified<br />
Supported by design<br />
Moxa • VPort461 Generic Plus (ONVIF) Tested by partner<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 23<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
Manufacturer Unit Models Extension Certification<br />
Samsung<br />
(ONVIF)<br />
• SNO-5080R Generic Plus (ONVIF) Supported by design<br />
Sentry 360 • FS-IP5000<br />
• FS-IP10K<br />
• FS-IP3000<br />
• IS-IP300<br />
• IS-IP500<br />
• IS-IP10K<br />
Sony • SNC-EP520<br />
• SNC-EP580<br />
• SNC-ER520<br />
• SNC-ER580<br />
Visiowave • EVOLUTION HD<br />
• DISCOVERY 300<br />
Sentry 360<br />
Sentry 360<br />
Sony<br />
Generic Plus<br />
Certified<br />
Supported by design<br />
Certified<br />
Certified<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 24<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
The following software issues were resolved in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong>. Generic issues are<br />
categorized by solution. Unit specific issues are categorized by manufacturer and/or model.<br />
NOTE SD stands for <strong>Security</strong> Desk, and CT stands for Config Tool.<br />
Solution/Unit Issue Description<br />
All 51058 IPV6 is not supported.<br />
All 56928 Sometimes the event-to-actions list in the Action tab is not automatically updated.<br />
Workaround: Manually refresh the page by clicking another tab in General Settings, and<br />
then clicking the Actions tab.<br />
All 56965 <strong>Security</strong> <strong>Center</strong> stops responding when trying to run a backup on a folder that does not<br />
exist.<br />
All 57687 Federation: When generating an event report on a federation host with multiple federated<br />
systems having custom events defined, the event sources are sometimes mixed up.<br />
All 57799 SD: In Guard Tour mode, when “Tile only” view is selected, the dashboard may appear<br />
briefly.<br />
All 57908 SD: When multiple messages are received (via Send a message action) and not read, only<br />
the first one generates an alert in the notification tray and is logged.<br />
All 59249 Licensing: An unhandled exception occurs after applying a license.<br />
Workaround: Refresh the Server Admin page and reapply the license.<br />
All 59916 SD: The Alarms list in the Actions tab of the Monitoring task is not populated until a<br />
Trigger alarm Hot action is created.<br />
All 59968 SD: Email sent for an “Email report” hot action contains wrong report title.<br />
All 67289 A <strong>Security</strong> <strong>Center</strong> role group can support up to 50 <strong>Security</strong> <strong>Center</strong> Federation roles.<br />
All 69808 SD: Enabling the visual tracking option on a tile causes the Timeline to disappear.<br />
All 69330 SD: Repeatedly sending and clearing a saved task to a <strong>Security</strong> Desk workstation may<br />
cause it to crash.<br />
All 70946 CT: No option to delete offline main server entity from the Network view.<br />
All 71804 CT: Cannot remove an access control unit from the Public partition.<br />
All 73892 Web SDK does not work on 64-bit machines.<br />
All 74659 SD: Sending, clearing, and resending a same task within a same session causes <strong>Security</strong><br />
Desk to crash.<br />
All 59982 SD: Events filter does not work for Zone activities report.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 25<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Solution/Unit Issue Description<br />
All 78936 You cannot edit a Weekly schedule or add and Ordinal schedule when using the Chinese<br />
simplified version of <strong>Security</strong> <strong>Center</strong>.<br />
All 79823 SD: Importing and exporting joystick configurations between users may not work<br />
correctly.<br />
All 79824 CT: You cannot use the Copy Configuration tool to copy the configuration of an Active<br />
Directory User group to another User group.<br />
Access 57416 Move unit: Access control unit stays offline after moving it from one Access Manager to<br />
another.<br />
Workaround: Manually restart the Access Manager after moving the unit.<br />
Access 57748 Global Cardholder Management: Adding entities to a global partition on the sharing host<br />
while sharing guests are synchronizing with it might cause a synchronization error to be<br />
logged.<br />
Workaround: Repeat the synchronization manually.<br />
Access 58001 Cardholder Management: Cardholder search does not work in Cards view.<br />
Workaround: Use Details view instead.<br />
Access 58207 Cannot use the copy configuration tool to copy access rules.<br />
Access 59075 CT - VertX units: Cannot refresh or view current Analog 2 Digital (A/D) values, when<br />
Config Tool window is at its minimum size.<br />
Access 59077 CT - VertX units: After changing the Analog 2 Digital (A/D) input calibration value, the<br />
Refresh button becomes unavailable.<br />
Workaround: On the Properties page, click another input or output. The Refresh button<br />
reappears.<br />
Access 59965 The Area presence and People counting reports do not report on newly added access<br />
control units.<br />
Workaround: After adding an access control unit to an Access Manager, deactivate and<br />
reactivate the Access Manager, and then run the reports.<br />
Access 71515 SDK: Once the Expiration credential has been set to a specific date, it cannot be changed<br />
to "Never".<br />
Access 76680 Galaxy Panel: Tampering alarms are not reported.<br />
Access 79770 SD: If you use the Custom field "Date" as a filter when you run a cardholder report, you<br />
may receive an error.<br />
Access 79813 Galaxy Panel: There is no way to delete a zone created in <strong>Security</strong> <strong>Center</strong>.<br />
Access 79825 CT: When cropping a cardholder image, the image is not cropped correctly.<br />
Access 79811 RF IDeas: Reader reverts to default factory settings each time it connects to Config Tool.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 26<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Solution/Unit Issue Description<br />
Access 79835 When enrolling a Bosch intrusion panel, only Area 1 is configured properly. The other<br />
areas appear offline and no inputs are detected.<br />
Video 55909 Panasonic BB-HCM735: PTZ coordinates dialog box does not display Pan, Tilt, Zoom<br />
coordinates.<br />
Workaround: Using the PTZ widget, change the PTZ position. The PTZ dialog is updated<br />
and displays the PTZ coordinates.<br />
Video 57433 Auxiliary Archiver: No warning message appears when adding a network location that<br />
does not meet minimum space requirements.<br />
Video 57555 Archiver: When you move a unit to a new Archiver, the destination archiver does not<br />
automatically add the extension to support the camera.<br />
Video 57634 Export: When exporting a video sequence that straddles the recording schedules of<br />
multiple Archivers and Auxiliary Archivers, some segments of the selected video sequence<br />
might be missing from the export.<br />
Video 57915 Export: When exporting video with a specific playback source from the tile, the export<br />
dialog does not remember the selected playback source.<br />
Workaround: Select again the source from the export dialog box.<br />
Video 58556 SD: Using the direct XYZ positioning feature (cursor shown as a cross) to pan the camera<br />
in one direction will block when the camera reaches the limit of its pan-tilt range. The<br />
wrap around is not automatic.<br />
Workaround: Switch to normal pan-tilt-zoom (click and drag from the blue center dot) to<br />
position the camera to where you want it to point.<br />
Video 59679 Audio: No half-duplex option for microphones.<br />
New "Audio mode" options have been added for <strong>Security</strong> Desk under Video options,<br />
Advanced settings. You can now choose between full-duplex and half-duplex.<br />
Video 66543 Motion threshold cannot be specified in terms of motion blocks, making it harder to use<br />
than it was in Omnicast.<br />
Video 69340 SD: Exporting a G64 file to ASF may not work properly if the file contains audio.<br />
Video 69496 New edge capabilities added by firmware upgrade not detected by the Archiver.<br />
Video 73262 SD: Clicking the “Go to specific time” button in the camera widget causes <strong>Security</strong> Desk to<br />
crash if the user does not have the privilege to run Archives report.<br />
Now, if the user does not have the "Archives" privilege, the date and time widget appears<br />
instead of the "Video archives" dialog box.<br />
Video 73998 SD: Removing and viewing again the same camera in a tile may cause the microphone<br />
button to become disabled.<br />
Video 74212 SD: Reverse playback does not work on H.264 high resolution video stream.<br />
Video 74216 SD: Reverse playback does not work on H.264 high resolution video stream.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 27<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong><br />
Solution/Unit Issue Description<br />
Video 74663 SD: When viewing live video in the Timeline, you may see black gaps with a “Buffering<br />
0%” error.<br />
Video 76299 SD: Exporting video in ASF format with syntax errors in the folder path causes <strong>Security</strong><br />
Desk to crash.<br />
Video 78016 ioimage TRK100D/4000D and Samsung SPE-100: When playing back MPEG-4 video on<br />
the Timeline, the image may freeze.<br />
Video 79506 SD: You may receive an Out of memory error when repeatedly exporting video to the ASF<br />
format.<br />
Axis 63202 P8221: Microphone and speaker does not enroll properly in <strong>Security</strong> <strong>Center</strong>.<br />
Axis 74935 PTZ pattern does not work on cameras using AXIS (Guard Tour) PTZ protocol.<br />
Bosch 72204 Bosch: Auto discovery cannot be deactivated.<br />
Bosch 74131 Bosch Autodome 700 IP (IVA): PTZ pattern recording does not work.<br />
The firmware must be upgraded to version 5.50 on the Bosch unit as well.<br />
Bosch 76132 Bosch extension: Changes to Multicast period and Broadcast period are not saved unless<br />
other changes are made at the same time.<br />
Cisco 64428 Cisco CIVS-IPC-2521V: Unable to position the playback on the desired timestamp.<br />
Interlogix 79170 SymNet: The Video tab is blank in the Config Tool.<br />
Pelco 60666 Pelco NET5301T: Baud rate option 2400 not available.<br />
Samsung 68869 Samsung SPD SCC-641/643: PTZ zoom does not work.<br />
Sentry 360 60803 In the Config Tool Video tab, the M-JPEG tab is available, even though M-JPEG is not<br />
supported.<br />
Sentry 360 60818 Frame rate changes are not applied to the video stream.<br />
Sentry 360 60836 When using the dewarping feature in <strong>Security</strong> Desk, the zoomed 360 o image does not<br />
support pan/tilt hand grip manipulation.<br />
Sentry 360 60837 When using the dewarping feature in <strong>Security</strong> Desk, the image thumbnail does not exactly<br />
match what is shown in the zoomed image.<br />
Sentry 360 60838 When using the dewarping feature in <strong>Security</strong> Desk, you cannot navigate the zoomed<br />
image using your keyboard arrows.<br />
Verint 60862 Verint S1801e: Choppy audio playback in <strong>Security</strong> Desk.<br />
Verint 69414 Verint S1801e: PCM audio codec not supported.<br />
Verint 78737 Verint S1950e: Audio may not work in <strong>Security</strong> Desk after the unit goes offline<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 28<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1<br />
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1<br />
The following software issues were resolved in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1. Generic issues are<br />
categorized by solution. Unit specific issues are categorized by manufacturer and/or model.<br />
NOTE SD stands for <strong>Security</strong> Desk, and CT stands for Config Tool.<br />
Solution/Unit Issue Description<br />
All 54987 CT: If you create two custom data types with similar names in the System task, the data<br />
type does not appear when it is selected by a custom field.<br />
All 60932 CT: Entities created with a wrong relationship (for example, a door under a door or a zone<br />
under a door) are not displayed in the Logical view.<br />
All 62682 After upgrading from <strong>Security</strong> <strong>Center</strong> 5.0 SR1 to <strong>5.1</strong> GA, a new server is created. As a<br />
result, the existing server and all associated roles become inactive.<br />
Workaround: Assign the roles to the new server.<br />
All 67216 In <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA, you cannot log on to <strong>Security</strong> <strong>Center</strong> using supervised logon.<br />
All 67742 SD: Selecting Force Windows credentials in the General options page of the Options<br />
dialog box only applies for the current user, not the local computer.<br />
Workaround: Select the Force Windows credentials option for each user individually.<br />
All 68325 If the connection between the Directory and the database is lost, when the connection is<br />
restored you cannot trigger alarms until the Directory is manually restarted.<br />
All 68329 After upgrading to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA, the Media Router stops working.<br />
All 68342 After upgrading to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA, you cannot delete the Federation role.<br />
All 68411 After upgrading to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA, Config Tool and <strong>Security</strong> Desk option<br />
modifications are lost.<br />
All 68755 After upgrading to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA, you may not be able to log on to <strong>Security</strong><br />
<strong>Center</strong> using Windows credentials.<br />
LPR 66586 AutoVu LPR: If you install Patroller without odometry, MapInfo maps turn blank if you<br />
move them.<br />
Mobile 63624 The Mobile Client license count is incorrect in the License page if you are using backward<br />
compatibility.<br />
Mobile 68374 Video sent from the Mobile Server takes a long time to load.<br />
Video 64550 CT: When you click Add network location in Archiver role’s Resources tab, you cannot<br />
add a network drive.<br />
Video 64552 Licensing: The Number of cameras license option lists more cameras than are actually in<br />
the system.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 29<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> SR1<br />
Solution/Unit Issue Description<br />
Video 68324 You cannot control the PTZ of a remote <strong>Security</strong> Desk camera unless the PTZ camera is<br />
also added to your local <strong>Security</strong> Desk.<br />
Video 68327 After a Directory failover, one of your Auxiliary Archivers may not restart.<br />
Video 68334 SD: Exporting video with a multiple day time range may not work.<br />
Video 68343 If the server assigned to the Archiver role is an expansion server, the cameras managed by<br />
the Archiver may go offline.<br />
Video 68347 SD: If you click Go to specific time in the camera widget, the camera may not play video<br />
at the selected time.<br />
Video 68639 SD: To use PTZ-in-tile with PTZ cameras that do not support Direct XYZ positioning, you<br />
must click the blue dot in the middle of the tile, and then drag the camera to move it in<br />
that direction.<br />
Axis 62409 The camera image rotation resets every time you log on to <strong>Security</strong> <strong>Center</strong>.<br />
Bosch 68531 Video using MPEG-4 4CIF resolution does not stream properly in <strong>Security</strong> Desk because<br />
the video is automatically interlaced.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 30<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
The following software issues were resolved in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA. Generic issues are<br />
categorized by solution. Unit specific issues are categorized by manufacturer and/or model.<br />
NOTE SD stands for <strong>Security</strong> Desk, and CT stands for Config Tool.<br />
Solution/Unit Issue Description<br />
All 30056 After installing or upgrading a <strong>Security</strong> <strong>Center</strong> main server (with Directory role), the<br />
<strong>Genetec</strong> Server service must be restarted.<br />
All 40466 Usernames with character '@' or '\' in their name cannot log in.<br />
All 40392 <strong>Security</strong> Desk monitoring or reporting tasks display all report fields, even when those<br />
fields are not applicable to the product license.<br />
All 40382 “Send email” action sends email twice for certain events.<br />
All 41140 Discovery tool option is disabled if the license does not support Synergis.<br />
All 44483 Cannot activate <strong>Security</strong> <strong>Center</strong> 5.0 SR1 using web activation.<br />
All 47683 Only users with Administrator Privileges can view Investigation Reports.<br />
All 48728 SQL 2008 installation fails when installing <strong>Security</strong> <strong>Center</strong> on a main or expansion server<br />
on Windows 2003 64bit.<br />
All 49614 Unit Discovery and Unit Replacement Tools are unavailable.<br />
All 50137 In Public address field, cannot enter a hostname that starts with digit.<br />
All 54754 When modifying an event-to-action, the “Create and edit an action” dialog box may not<br />
display current settings for that action.<br />
Access 29984 The battery fail event is not reported on V100, V200, V300 interface panels. It is only<br />
reported on the V1000 master controller.<br />
Access 44384 Cannot configure an elevator with more than 10 floors.<br />
Access 49255 HID controller must be synchronized before it can be put in maintenance mode.<br />
Access 50452 The image appears stretched when taking a Snapshot for a cardholder picture from a<br />
Federated camera.<br />
Access 55862 Cardholder Management task labels are incorrect.<br />
Video 40396 Changing the discovery port on an Archiver for Bosch video hardware does not replace the<br />
original port, but rather adds a second discovery port. Consequently, the wrong video<br />
streams may be displayed and recorded.<br />
Video 40469 Deleting a camera from one archiver and adding it to another does not change its<br />
recording setting (Inherit from Archiver).<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 31<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
Solution/Unit Issue Description<br />
Video 40339 It may be possible to add more cameras than allowed by the system license.<br />
Video 40600 When attaching a PTZ camera to a door and assigning a PTZ preset, only the first seven<br />
presets are available.<br />
Video 49891 DVMRe images are upside down in <strong>Security</strong> Desk.<br />
Video 50871 Live video freezes when switching between cameras in <strong>Security</strong> Desk.<br />
Video 53551 Playback does not work properly when done from multiple networks.<br />
Video 53859 Omnicast Federation role may time out when “Signal lost” events occurs.<br />
Video 54019 If you are using two network interface cards (NICs) on your <strong>Security</strong> <strong>Center</strong> server (for<br />
example, if all your cameras are on one network and all your client workstations are on a<br />
different network), you may not be able to view live or playback video, and the cameras will<br />
show the message “Waiting for signal”.<br />
Video 54437 When displaying an HTML map in a bottom tile, and switching a camera in another tile to<br />
playback mode, the map overlaps the video thumbnails.<br />
Video 56398 Pelco9760 and Pelco KDB300 do not work in <strong>Security</strong> Desk.<br />
Video 57022 Video export missing first watermarked sequence.<br />
ACTi 1395 ACTi–CAM65xx/66xx: Some Dynacolor PTZ commands are not working (ex. Run a<br />
pattern).<br />
ACTi 45696 Motion off events are not generated when using Full Screen (Unit) motion detection on an<br />
ACM-5611 unit.<br />
Arecont 24690 When using an H.264 stream: The AV8185 and AV8365 units do not support Unicast TCP.<br />
Arecont 29424 Software motion detection is not supported on AV10005 units.<br />
Interlogix 49665 UVE-101, UVD-IP-EVRDNR-VA2, and UVD-IP-XP3DNR-VA2: Still frame alarms do not<br />
work.<br />
Panasonic 23952 Panasonic WV-SP102: 1280x960 and 1280x720 resolutions are visible in the Config Tool<br />
even though they are not supported by the unit.<br />
Panasonic 27480 DG-SC385: The connection type under the Specific settings tab is incorrect in some cases.<br />
Panasonic 45531 For some unit and firmware combinations, software motion detection does not analyze the<br />
bottom part (approx. 10%) of the video image in MPEG-4 streaming.<br />
Sanyo<br />
(ONVIF)<br />
Sanyo<br />
(ONVIF)<br />
29121 VCC-HD5400: After switching from 30 fps to a higher resolution, the frame rate cannot be<br />
reset to 30 fps.<br />
29244 VCC-HD4600: Pan/tilt commands have no effect on the unit.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 32<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Resolved issues in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA<br />
Solution/Unit Issue Description<br />
Sanyo<br />
(ONVIF)<br />
Sanyo<br />
(ONVIF)<br />
Sanyo<br />
(ONVIF)<br />
Sanyo<br />
(ONVIF)<br />
29475 VCC-HD4600, VCC-HD5400, and VCC-HD5600: When using H.264 streaming, RTSP<br />
over TCP, multiple unit lost/discovered events occur while performing a guard tour.<br />
49666 VDC-HD3500, VCC-HD5600: Sometimes the units cannot be added.<br />
49667 The first PTZ preset cannot be modified with the set/clear preset commands. The camera<br />
position can only be changed using the SetHomePosition command.<br />
49669 VCC-HD5400, VCC-HD5600: Presets do not work in Omnicast.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 33<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Known issues<br />
Known issues<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> includes the following known issues. Generic issues are categorized<br />
by solution. Unit specific issues are categorized by manufacturer and/or model.<br />
For a list of supported hardware known issues and limitations in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong>,<br />
see the GTAP Known Issues page, at https://gtap.genetec.com. You’ll need a username and<br />
password to log on to GTAP.<br />
NOTE SD stands for <strong>Security</strong> Desk, and CT stands for Config Tool.<br />
Solution/Unit Issue Description<br />
All 21823 CT: For languages written from right to left, such as Arabic and Persian, the user interface<br />
of some tools and configuration tabs in the Config Tool may not have been inverted.<br />
All 56399 CT: Deleting a unit does not remove the references to its devices in the configuration of<br />
other entities, such as zones.<br />
Workaround: Manually remove the references to devices of deleted units from other entity<br />
configurations.<br />
All 56972 CT: Deleting a role's database whose status is Not connected, may cause the role to go<br />
offline. To bring the role back online, you'll need to click Deactivate role and then Activate<br />
role.<br />
All 57800 SD/CT: Under Windows XP, the drop-down menu sometimes appears behind the window<br />
it belongs to.<br />
All 58186 SD/CT: Custom filter applied using the Search dialog box does not always display properly.<br />
Workaround: Select the control where the selection is supposed to appear and do a right<br />
mouse-click or press F5.<br />
All 59831 Information about query results greater than 500 appears as<br />
an error message (“error occurred while processing” or “Query<br />
failure”), leading the user to think an error occurred.<br />
This message should be displayed as an information message, not as an error message, since<br />
<strong>Security</strong> <strong>Center</strong> is letting the user know that the report is not displaying images in order to<br />
prevent timeout errors.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 34<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Known issues<br />
Solution/Unit Issue Description<br />
All 60026 When upgrading a secondary Archiver server, the Archiver role does not automatically fail<br />
back to the primary Archiver server, resulting in the loss of video recordings during the<br />
upgrade period.<br />
Workaround: Before you upgrade the secondary Archiver server, you'll need to stop the<br />
ArchiverDomain service on the secondary Archiver server.<br />
1 Upgrade the main server.<br />
The primary Archiver server continues to record video.<br />
2 Upgrade the primary Archiver server.<br />
The Archiver role fails over to the secondary Archiver server.<br />
3 On the secondary Archiver server, open the Server Admin console: from a web browser,<br />
type ///genetec/console#/Services.<br />
4 From the Service domains list, select ArchiverDomain, and then click X at the bottom<br />
of the list.<br />
The Archiver role fails back to the primary Archiver server.<br />
5 Upgrade the secondary Archiver server.<br />
All 61475 Zone: Config Tool does not prevent an input used for zone arming/disarming from being<br />
used as zone input, making it impossible for the zone to be armed on input change.<br />
All 62247 Server Admin: Illegal characters entered by mistake in the "<strong>Security</strong> <strong>Center</strong> Directory" field<br />
of an expansion server prevent the <strong>Genetec</strong> Server service from restarting.<br />
Workaround: Manually edit the file C:\Program Files\<strong>Genetec</strong> <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong>\ConfigurationFiles\<strong>Genetec</strong>Server.gconfig<br />
and change in the tag, the directory<br />
parameter to blank (directory=""), then manually start the <strong>Genetec</strong> Server service.<br />
All 64016 Health monitoring: No way to filter the Health history report based on a particular<br />
Directory (as Source entity).<br />
Workaround: Use the Directory source group instead. But all Directories will be listed, if<br />
there are many.<br />
All 64017 IPv6: After enabling IPv6 on your system, all network cards on the servers discovered prior<br />
to switching to IPv6 retain their names showing an IPv4 address, which could be<br />
misleading.<br />
All 64025 IPv6: Unable to connect to Server Admin with Config Tool (Network view > server entity)<br />
when IPv6 is enabled.<br />
Workaround: Use an external Web browser (IE9) instead.<br />
All 64178 Time zone : The option to “Display time based on each device’s time zone” is ignored by the<br />
Archives and Health history reports. This may cause you to miss certain expected events if<br />
your workstation and the devices being investigated are not in the same time zone.<br />
All 64516 Health monitoring: Not all health events, such as Archiving started and Database lost, are<br />
logged by the Health monitor.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 35<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Known issues<br />
Solution/Unit Issue Description<br />
All 67032 Health monitoring: Some health events are not logged, such as Directory started and<br />
Directory stopped unexpectedly, when the Directory database failover uses Mirroring.<br />
All 68656 SD/CT: Email report does not display the settings you configured in the Date and time<br />
options tab, instead it displays the date and time settings of the <strong>Genetec</strong> main server.<br />
All 73182 Server Admin: Invalid database names are not detected at creation time, leading to an<br />
invalid database to be created, which cannot be deleted from Sever Admin.<br />
Workaround: Use SQL Server Management Studio to manually delete the invalid database,<br />
then recreate a valid database with Server Admin.<br />
All 74270 CT: License usage count is not updated when units are added or removed from the system.<br />
Workaround: Restart Config Tool. Simply logging off and on is not enough.<br />
All 80865 CT: Language tool does not work properly for Simplified Chinese.<br />
Access 40220 SD: “Door locked” and “Door unlocked” events are not shown in the Door activity report.<br />
Access 40596 The limitations when triggering outputs in a zone are as follows:<br />
• The entry delay is applied for both the Normal-to-Active and Active-to-Normal zone<br />
state transitions.<br />
• When an Active-to-Normal zone state transition occurs, all corresponding event-toactions<br />
will launch immediately except for the trigger output, which will launch after<br />
entry delay expires.<br />
Access 59362 Cardholder Management: Cropping feature does not crop the area defined by the user.<br />
Access 59530 CT: Not all required fields for Honeywell intrusion detection units are validated by the<br />
entity creation wizard.<br />
Workaround: When creating a Honeywell intrusion detection unit, the Account number<br />
and the Remote user code must be numeric and not exceed 6 digits each.<br />
Access 60634 Global Cardholder Management: The first scheduled synchronization fails.<br />
Workaround: Perform a manual synchronization first. The following scheduled synchronizations<br />
will then run successfully.<br />
Access 77317 CT: While creating a new cardholder with the wizard, once the cardholder entity name is<br />
initialized, going back to change the first or last name does not automatically update the<br />
entity name.<br />
Video 52686 When a server is configured as a proxy (with a public address) on a network, all stream<br />
requests are redirected through it, even when the request is issued from inside the network.<br />
Workaround: To avoid having the proxy server becoming a bottleneck, create a dummy<br />
network entity and assign the proxy server to it.<br />
Video 57147 SD: Viewing multiple video streams federated from Omnicast 4.x in synchronized playback<br />
mode does not always work.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 36<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Known issues<br />
Solution/Unit Issue Description<br />
Video 57265 SD: When you move playback to the beginning of a sequence, audio may stop. To turn<br />
audio back on, click Listen twice.<br />
Video 57553 Auxiliary Archiver: when you deactivate and activate the role, a warning appears briefly on<br />
screen. This is a false-positive warning notification.<br />
Video 57829 SD: The playback timeline might not display correctly when switching between valid and<br />
invalid video sources.<br />
Workaround: Select the valid playback source a second time.<br />
Video 58555 CT: PTZ calibration for the direct XYZ positioning feature is very difficult because the<br />
specific field of view parameters are not supplied by default for the specific camera model.<br />
Video 58892 Video feed may flicker when changing the resolution.<br />
Video 64168 Move unit: When moving an edge recording camera from one Archiver to another, the<br />
trickling parameters are not deleted from the first Archiver.<br />
Video 64546 IPv6: After an Archiver failover or failback on a full IPv6 network, the video stream<br />
connections are not restored.<br />
Video 66950 Media Router: When IPv6 is enabled, all IPv4 video streams are ignored. Media Router<br />
does not support dual stack. When you decide to enable IPv6 on one server in your system,<br />
you must enable it on all servers in your system. A <strong>Security</strong> <strong>Center</strong> system using IPv6<br />
cannot receive the video from a federated system using IPv4.<br />
Video 67536 Migration tool: Steps that do not apply to certain scenarios are left empty by the Wizard<br />
instead of being skipped, such as the "Omnicast information" step when there is no<br />
Directory to migrate, which could be confusing to the user.<br />
Video 69274 SD: Audio volume cannot be changed on <strong>Security</strong> Desk when it comes from federated<br />
Omnicast cameras and decoded using out of process media components.<br />
Video 74109 CT: Changing the key frame interval on a H.264 camera from number of seconds per key<br />
frame to number of images per key frame may cause the video streaming to stop.<br />
Workaround: Change something else in the video quality and click Apply.<br />
Video 74163 CT: The key frame interval is not converted properly from number of images per key frame<br />
to number of seconds per key frame if the end result is less than a second.<br />
Workaround: Change the key frame interval to 2 seconds and back to 1 second.<br />
Video 76093 Audio playback is not always available at the time audio recording is started. The Archiver<br />
saves audio and video streams in video files (G64). If audio recording is enabled in the<br />
middle of a video file, audio playback will only be available at the start of the next video file.<br />
Video 76407 Some video stream statistics information overlayed on the video tile (CTRL+SHIFT+A) is<br />
not updated during playback. The Key frame interval is not updated at playback speed<br />
higher than 4x or -4x. The RTP packets lost/received are not updated during playback. The<br />
Network transport is not updated during playback.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 37<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Known issues<br />
Solution/Unit Issue Description<br />
Video 76946 Motion detection: On high resolution cameras, Config Tool does not display as many<br />
motion blocks as the Archiver is capable of detecting.<br />
Video 77127 Export: Folders are not created automatically if they do not exist.<br />
Workaround: Manually create the folder before the export.<br />
Video 77176 CPU usage is not shown correctly in the notification tray when <strong>Security</strong> Desk is overloaded<br />
(16 camera streams).<br />
Video 77179 Export: The Export video from all tiles command (CTRL+SHIFT+E) only exports the tiles<br />
showing playback video.<br />
Workaround: Use the Export video from selected tile command (CTRL+E) instead.<br />
Video 77312 SD: When the timeline is displayed in a tile, it may take up to 5 seconds for the information<br />
to be refreshed.<br />
Video 77316 Auxiliary Archiver: Switching the order of the archive storage disks does not take effect<br />
until the role is restarted.<br />
Video 77642 SD: The Listen button in the camera widget remains enabled when the playback speed is<br />
higher than 4x or -4x, eventhough the audio is automatically disabled.<br />
Video 77721 Edge playback: Audio playback is not supported on edge recording unit.<br />
Video 82517 Trickling: Video Trickling does not work correctly on Windows XP.<br />
HID 3461 V200/V300: Periodic output behavior does not always toggle properly. Recommendation:<br />
Set output transitions for a minimum duration of 5 seconds or more.<br />
HID 56493 HID VertX V1000: On the first attempt, <strong>Security</strong> <strong>Center</strong> may not be able to add a VertX<br />
V1000 unit (2.2.7.78). The first time you try to add a VertX V1000 (2.2.7.78) to <strong>Security</strong><br />
<strong>Center</strong>, an error appears. <strong>Security</strong> <strong>Center</strong> will then reboot the unit. After the unit is<br />
rebooted, the second time you try to add the unit, <strong>Security</strong> <strong>Center</strong> is able to add the unit to<br />
the system.<br />
HID 57112 Unit discovery does not show the new name you give to a unit (in the unit, Identities tab)<br />
until the unit is rebooted or its power is cycled.<br />
HID 57113 When a Door unlock schedule override is removed, there is a delay of 40 seconds before<br />
the door’s unit is fully programmed.<br />
Interlogix 69015 Interlogix: Configuring motion detection on Interlogix Legend IP cameras may cause the<br />
Config Tool to crash.<br />
Sentry 360 59245 Camera may stop responding and require a power cycle to come back online.<br />
Sentry 360 60643 Cameras using H.264 can produce large increases in bandwidth usage that result in video<br />
glitches.<br />
Workaround: Install camera on a Gigabit network.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 38<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Known issues<br />
Solution/Unit Issue Description<br />
Sentry 360 60839 When using the dewarping feature in <strong>Security</strong> Desk, if you zoom using your mouse wheel<br />
button, it zooms to the center of the image, not where your mouse is pointing.<br />
Sentry 360 60840 When using the dewarping feature in <strong>Security</strong> Desk, the overview image does not match<br />
the zoom regions.<br />
Sentry 360 60841 When using the dewarping feature in <strong>Security</strong> Desk, the overview image displays the first<br />
frame when the camera was dropped in the tile.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 39<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Limitations<br />
Limitations<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> includes the following known limitations. Generic limitations are<br />
categorized by solution. Unit specific limitations are categorized by manufacturer and/or<br />
model.<br />
For a list of supported hardware known issues and limitations in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong>,<br />
see the GTAP Known Issues page, at https://gtap.genetec.com. You’ll need a username and<br />
password to log on to GTAP.<br />
NOTE SD stands for <strong>Security</strong> Desk, and CT stands for Config Tool.<br />
Solution/Unit Issue Description<br />
All 10997 (Ref. 17369) Scheduled tasks with “On startup” recurrence property may not run on<br />
startup. Workaround: Limit the “On startup” tasks to “Execute a macro” actions.<br />
All 11280 The status of a device (camera or door) shown in a <strong>Security</strong> <strong>Center</strong> map is not updated on<br />
the map when the device goes temporarily offline (red) and back online.<br />
Workaround: Remove the map from the canvas and drag it back to the canvas.<br />
All 12224 Time zone abbreviations are not supported in the printed reports.<br />
All 13097 The Active Directory role may stop working after the Microsoft Active Directory domain<br />
controller is restarted.<br />
Workaround: Deactivate the role for at least 3 minutes and reactivate it.<br />
All 13616 Database backups cannot be purged when the database server is not on the same computer<br />
as the server role (<strong>Security</strong> <strong>Center</strong> Directory or Synergis Access Manager).<br />
All 22169 Server Admin cannot use the default HTTP port 80 on a Windows XP 32-bit machine if IIS<br />
service is installed. (Workaround modify port to use one other than port 80).<br />
All 24428 <strong>Security</strong> Desk keyboard shortcuts cannot be used (such as space to acknowledge an alarm)<br />
when the focus is on a tile displaying a map.<br />
Workaround: Use the command buttons found in the map instead.<br />
All 56703 SD: Not all query filters in reporting tasks are updated live when the system configuration<br />
changes, such as when new custom fields or custom events are added.<br />
Workaround: To view the new query filter options, delete the task and recreate it.<br />
All 70356 The Portable Archive Player cannot play back encrypted video.<br />
Access 16721 Modifying the members (doors, elevators, captive areas) of an area might disrupt the Time<br />
and attendance report of that area for the time range prior to the change.<br />
Workaround: Restoring the old membership settings also restores the old time and attendance<br />
values.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 40<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Limitations<br />
Solution/Unit Issue Description<br />
Access 19239 Elevator control – Configuring an exception to unlock schedule (controlled access) on a<br />
floor without a corresponding unlock schedule (free access) may cause the VertX controller<br />
to stop sending events to the Access Manager.<br />
Access 21998 PIN credential active state is ignored when used with a CARD & PIN reader. To support<br />
units that have a combination of normal readers and CARD & PIN readers, only the<br />
CARD's credential status is used.<br />
Access 37088 <strong>Security</strong> <strong>Center</strong> does not support Reactivation threshold settings for zones entities.<br />
Access 51996 When the association between a credential and a badge template is changed at a remote site<br />
(in a roaming environment), this change is not updated at the central site.<br />
Access 57615 Denying a Global Cardholder Synchronizer role the “Modify credential information”<br />
privilege does not prevent its users on the sharing site from changing the shared PIN<br />
credentials.<br />
Workaround: In the context of Global Cardholder Management, in order to prevent the<br />
sharing site users from modifying the shared PIN credentials, the Global Cardholder Synchronizer<br />
roles must be denied the “Add/delete credentials” privilege on the sharing host.<br />
Access 77794 Creating two Access Manager roles on the same host server is not supported and will<br />
generate a "Database service already exists" error. The error will persist even after you<br />
delete one of the roles.<br />
Intrusion 26345 Bosch GV2 alarm panel: If an intrusion area is not ready to be armed, the alarm panel will<br />
still accept the command to arm it. However, it will only be armed once the intrusion area<br />
is actually ready to be armed.<br />
LPR 15199 AutoVu LPR: Sharp units under Patrollers always appear as online in SD and CT, regardless<br />
of their real status, as long as the Patroller is connected to the LPR Manager external<br />
system.<br />
LPR 15676 AutoVu LPR: When configuring a permit restriction, it is not possible to define a time<br />
restriction that spans only one day.<br />
LPR 16619 AutoVu LPR: While parsing hotlist or permit data files, parsing errors such as the use of<br />
wrong delimiter characters, are not indicated.<br />
Workaround: Always double-check that the files are loaded correctly in the Patroller.<br />
LPR 17892 SD – Geographical map: Regions drawn on maps as filters for certain type of reports<br />
appear on top of the Bing map controls, blocking their access.<br />
Workaround: Move the map around or zoom in/out with the mouse wheel.<br />
LPR 18525 AutoVu LPR – SD: When the thumbnail LPR images are not shown in a LPR report (for<br />
queries returning more than 1000 rows), they are not displayed in the tiles either.<br />
Workaround: Click on the “Magnifying glass” button in the tile to display the LPR image.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 41<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Limitations<br />
Solution/Unit Issue Description<br />
LPR 19580 Inventory management task and Inventory report tasks in the <strong>Security</strong>Desk may use a lot of<br />
memory. To avoid performance issues while running a query on a large parking facility<br />
inventory (40K places or more), it is recommended to delete all tasks unrelated to MLPI<br />
from your task list before launching the query.<br />
LPR 20489 SD: The timestamp associated to a hit corresponds to the time the patrolling officer took<br />
action on the hit (Accepted, Rejected, or Not enforced), not the time the hit was raised.<br />
LPR 25725 LPR Manager database cleanup begins when the LPR Manager database table reaches<br />
20,000 reads. Previously, the LPR Manager database cleanup did not start until the database<br />
table reached 100,0000 reads. If using SQL 2008 Express, the database could not reach<br />
100,000 reads before reaching the 4 GB limit in SQL Express.<br />
LPR 26008 While upgrading <strong>Security</strong> <strong>Center</strong> from 4.0 to 5.0, the server and database used in 4.0 are<br />
not automatically reassigned to the LPR Manager role in 5.0.<br />
Workaround: You need to reassign the resources manually in the Config Tool.<br />
LPR 44225 SD: In an Inventory report, to permanently get rid of the unreconciled reads, you must<br />
delete them from the database, one at a time. Using the multiple selection only removes<br />
them from your current report.<br />
NOTE Deleting an unreconciled read from the database means you are deleting it from the<br />
offload file, so it will not reappear the next time you look for it in the Inventory report. The<br />
read remains available in the database other reads report.<br />
LPR 56903 In Config Tool, after moving a Patroller unit to another LPR Manager, it still appears under<br />
the previous LPR Manager.<br />
Workaround: Click Refresh in the Entity browser.<br />
LPR 57731 Moving a Patroller unit to a new LPR Manager requires additional setting changes in<br />
Patroller Config Tool. For more information, see “Move Patroller or LPR units betweenLPR<br />
Managers” in the AutoVu Handbook.<br />
Video 11998 Omnicast 4 alarm priorities are not converted when federated in the <strong>Security</strong> <strong>Center</strong>. All<br />
federated Omnicast alarms have a priority of 1.<br />
Workaround: Adjust the priorities of federated Omnicast alarms manually in the Config<br />
Tool.<br />
Video 12908 The nVidia video card may cause the <strong>Security</strong> Desk to stop working when hardware<br />
acceleration is turned on and set to “Full”.<br />
Workaround: Set hardware acceleration to “None”.<br />
Video 13195 If UltraVNC is installed on a computer, the <strong>Security</strong> Desk may be unable to display video.<br />
Workaround: Uninstall UltraVNC.<br />
Video 25318 Federated camera sequences does not show video from cameras that are blocked to any<br />
user on the remote system, regardless of the privileges of the user account used to connect<br />
to the federated Directory.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 42<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Limitations<br />
Solution/Unit Issue Description<br />
Video 25322 All cameras in a federated camera sequence are displayed on the federation host even<br />
though the user account used to connect to the federated Directory does not have access to<br />
all of them.<br />
Video 28991 SD: When displaying an HTML map in a tile while viewing video in the tile next to it, the<br />
map will overlap the video thumbnails.<br />
Video 40314 Alarm playback loop is permanently set in <strong>Security</strong> Desk.<br />
The alarm playback loop is set between the following time ranges:<br />
• Start time: Alarm trigger minus pre-trigger setting.<br />
• End time: Alarm trigger plus 10 seconds.<br />
Video 52172 When attempting to back up an Auxiliary Archiver that is installed on an expansion server<br />
to a file on that computer, you may receive an error because the SQL Server may not have<br />
permission to back up to that location.<br />
Workaround: Back up to a folder the SQL Server has access to.<br />
Video 58329 Backward compatibility: <strong>Security</strong> Desk 5.0 and earlier cannot play AAC audio coming<br />
from <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong>.<br />
Video 63409 Move unit: After moving a video unit, the unit is still shown under its old Archiver after it<br />
comes back online.<br />
Workaround: Manually refresh the entity tree after the unit comes back online.<br />
Video 63523 Move unit: Cannot view playback video from Auxiliary Archiver after moving a video unit<br />
from one Archiver role to another.<br />
Workaround: Restart <strong>Genetec</strong> Server service hosting the Auxiliary Archiver.<br />
Video 64274 Edge recording: Thumbnails are not available if the video is only recorded on the edge unit.<br />
Workaround: To see thumbnails in any kind of video reports (Bookmarks, Camera events,<br />
etc.), the video must be trickled to the Archiver.<br />
Video 78880 SD: When playing back Omnicast 4.8 federated video, the rewind speed starts at -10x<br />
instead of -1x.<br />
Video 81898 When you export a G64 file that contains audio to ASF, the audio quality is bad.<br />
Bosch 76282 Bosch MPEG2 units: G64-to-ASF conversion takes longer on <strong>Security</strong> <strong>Center</strong> than on<br />
Omnicast.<br />
HID 57114 AC fail inputs: If the VertX V1000 AC Fail input is used to monitor AC, then the AC Fail<br />
inputs on all interface modules (V100, V200, V300) controlled by the V1000 must only be<br />
used for monitoring AC. Similarly, if the V1000 AC Fail is used as a general purpose input,<br />
the AC Fail interface modules must only be used for general purpose inputs.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 43<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Limitations<br />
Solution/Unit Issue Description<br />
HID 57115 Battery fail inputs: If the VertX V1000 Battery Fail input is used to monitor battery failure,<br />
then the Battery Fail inputs on all interface modules (V100, V200, V300) controlled by the<br />
V1000 must only be used for monitoring battery failure. Similarly, if the V1000 Battery Fail<br />
is used as a general purpose input, the Battery Fail interface modules must only be used for<br />
general purpose inputs.<br />
HID 57116 The HID VertX V1000 inputs and outputs cannot be used for the following purposes:<br />
• A door REX, door sensor, door lock<br />
• Elevator control or floor tracking<br />
• Interlock, including the override or lockdown functions<br />
• Readerless door<br />
• IO linking (Zone)<br />
• Door buzzer<br />
HID 57118 The HID Edge device (EdgeReader or EdgePlus) can only be used to control a single door.<br />
You cannot use two HID Edge devices to configure a door with two readers. The supported<br />
configuration for an Edge device is a card-in /REX-out door.<br />
HID 57119 You must stop the Access Manager before initiating a unit swap operation in the Config<br />
Tool. Once the swap is completed, the Access Manager can be restarted.<br />
Panasonic 40143 GXE500: When configuring multiple MPEG-4 streams in Config Tool, the Quality settings<br />
of stream 2 overwrite the settings of stream 1.<br />
Panasonic 41847 WV-SW355: A frame rate of 30 fps in MPEG is not supported.<br />
Interlogix 68001 Interlogix DVMRe units: G64-to-ASF conversion takes longer on <strong>Security</strong> <strong>Center</strong> than on<br />
Omnicast.<br />
Sony 74587 Sony 5th generation video units: The resolution of the second stream cannot be higher<br />
than the resolution of the first stream.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 44<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
System requirements<br />
System requirements<br />
For system requirements, see the <strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide, available<br />
at: http://downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<strong>SR2</strong>/<strong>Security</strong>_<strong>Center</strong>/EN.<strong>Security</strong><br />
<strong>Center</strong> Installation and Upgrade Guide <strong>5.1</strong> <strong>SR2</strong>.pdf.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 45<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Supported video units<br />
Supported video units<br />
For details such as firmware and certification level of the video units supported by <strong>Security</strong><br />
<strong>Center</strong>, see the Supported Devices list on <strong>Genetec</strong>'s Technical Assistance Portal (GTAP), at<br />
https://gtap.genetec.com. You’ll need a username and password to log on to GTAP.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 46<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Supported HID units<br />
Supported HID units<br />
This section includes the following topics:<br />
• "HID unit compatibility" on page 47<br />
• "HID interface module program and EEPROM" on page 47<br />
HID unit compatibility<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> is compatible with the following HID unit firmware versions:<br />
HID VertX<br />
2.2.7.18<br />
2.2.7.39<br />
2.2.7.49.1<br />
2.2.7.70 a<br />
2.2.7.149<br />
HID EdgeReader / EdgePlus<br />
2.2.7.18<br />
2.2.7.39<br />
2.2.7.49.1<br />
2.2.7.70<br />
2.2.7.149<br />
a. Version 2.2.7.70 does not support elevator control and V1000<br />
with 12 to 16 interface modules connected. If these features are<br />
required, you’ll need to upgrade to 2.2.7.149.<br />
HID interface module program and EEPROM<br />
HID units should have the following Program and EEPROM firmware:<br />
HID interface unit Program EEPROM<br />
V100<br />
V2000 (has a V100 interface board built-in)<br />
EdgePlus/EdgeReader<br />
113 110<br />
V200 106 105<br />
V300 107 104<br />
For instructions on how to upgrade a unit’s firmware, see the <strong>Security</strong> <strong>Center</strong> Administrator<br />
Guide.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 47<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Supported intrusion detection units<br />
Supported intrusion detection units<br />
This section includes the following topics:<br />
• "Supported Bosch intrusion detection devices" on page 48<br />
• "Supported Honeywell Galaxy intrusion detection devices" on page 49<br />
Supported Bosch intrusion detection devices<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> supports the following Bosch GV2 and GV3 alarm panel devices.<br />
For each device, the corresponding firmware and certification level is listed.<br />
Model Device type Firmware Certification<br />
D7212GV2/GV3 Alarm panel GV2: ver.7.08<br />
GV3: ver. 8.04<br />
D7412GV2/GV3 Alarm panel GV2: ver.7.08<br />
GV3: ver. 8.04<br />
D9412GV2/GV3 Alarm panel GV2: ver.7.08<br />
GV3: ver. 8.04<br />
Supported by design<br />
Supported by design<br />
Certified<br />
D1255 Keypad Certified<br />
D125B Dual Class B Initiating Module Supported by design<br />
D8125 Addressable expansion module Certified<br />
D8128D Input expansion module Certified<br />
D8129 Octo-Relay module Supported by design<br />
D9127 POPIT modules Supported by design<br />
DS7432 Eight-input Remote Module Supported by design<br />
DS7457i<br />
Single Zone Multiplex Input<br />
module<br />
Supported by design<br />
DS7460i Dual-input module Supported by design<br />
DS7461i Single-input Multiplex module Supported by design<br />
DS7465i Input and Output Module Supported by design<br />
DX4010i RS-232 Serial Interface Module Supported by design<br />
DX4010V2 USB/Serial interface module Certified<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 48<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Supported intrusion detection units<br />
Model Device type Firmware Certification<br />
DX4020<br />
Ethernet Network Interface<br />
Module<br />
Certified<br />
Supported Honeywell Galaxy intrusion detection devices<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> supports the following Honeywell Galaxy Dimension control panel<br />
devices. For each device, the corresponding firmware and certification level is listed.<br />
Model Device type Firmware Certification<br />
GD-48 Control panel Version 6.7 and later Certified<br />
GD-96 Control panel Version 6.7 and later Supported by design<br />
GD-264 Control panel Version 6.7 and later Supported by design<br />
GD-520 Control panel Version 6.7 and later Certified<br />
A234 RS-232 Lead Kit Certified<br />
C072 Rio Expander module Certified<br />
CP037 Keypad Certified<br />
For more information on the known issues and limitations for Honeywell Galaxy<br />
Dimension control panel devices in this release, see the Honeywell Galaxy Control Panel<br />
Integration Plugin User Guide <strong>5.1</strong> GA.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 49<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Supported languages<br />
Supported languages<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> software is available in the following languages:<br />
• Arabic<br />
• Dutch<br />
• English<br />
• French<br />
• German<br />
• Hebrew<br />
• Hungarian<br />
• Italian<br />
• Japanese<br />
• Korean<br />
• Persian<br />
• Polish<br />
• Portuguese–Brazil<br />
• Spanish<br />
• Simplified Chinese and Traditional Chinese<br />
• Thai<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 50<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Upgrading from earlier versions of <strong>Security</strong> <strong>Center</strong><br />
Upgrading from earlier versions of <strong>Security</strong> <strong>Center</strong><br />
The following earlier versions of <strong>Security</strong> <strong>Center</strong> can be upgraded to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong><br />
<strong>SR2</strong>:<br />
• <strong>Security</strong> <strong>Center</strong> 3.0 GA /SR1<br />
• <strong>Security</strong> <strong>Center</strong> 4.0 GA /SR1<br />
• <strong>Security</strong> <strong>Center</strong> 5.0 GA /SR1<br />
• <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> GA /SR1<br />
Upgrading from Synergis 2.1<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> does not support upgrades from Synergis 2.1. You must first upgrade<br />
from Synergis 2.1 to <strong>Security</strong> <strong>Center</strong> 4.0 SR1, and then upgrade to the <strong>latest</strong> version of<br />
<strong>Security</strong> <strong>Center</strong>.<br />
For more information, see “Upgrading from Synergis 2.1” in the <strong>Security</strong> <strong>Center</strong> 4.0 SR1<br />
Installation and Upgrade Guide, available at: http://downloads.genetec.com/<br />
<strong>Security</strong><strong>Center</strong>/4.0/SR1/EN.<strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide 4.0 SR1.pdf<br />
Migrating from Omnicast<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> supports migrations from Omnicast 4.5 and later.<br />
For more information, see “Migrating from Omnicast 4.5 and later” in the <strong>Security</strong> <strong>Center</strong><br />
Installation and Upgrade Guide, see http://downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<br />
<strong>SR2</strong>/<strong>Security</strong>_<strong>Center</strong>/EN.<strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide <strong>5.1</strong> <strong>SR2</strong>.pdf.<br />
Migrating from AutoVu 4.3<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> does not support migrations from AutoVu 4.3. You must migrate<br />
AutoVu 4.3 data to <strong>Security</strong> <strong>Center</strong> 5.0 SR1 using the Data import tool.<br />
For more information, see “Migrating from AutoVu 4.3” in the <strong>Security</strong> <strong>Center</strong> 5.0 SR1<br />
Installation and Upgrade Guide, see http://downloads.genetec.com/<strong>Security</strong><strong>Center</strong>/5.0/<br />
SR1/<strong>Security</strong>_<strong>Center</strong>/EN.<strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide 5.0 SR1.pdf<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 51<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
<strong>Security</strong> <strong>Center</strong> compatibility<br />
<strong>Security</strong> <strong>Center</strong> compatibility<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> components are compatible with the following <strong>Security</strong> <strong>Center</strong><br />
components.<br />
NOTE Product release versions listed at the top of the table include all subsequent releases<br />
unless specified.<br />
<strong>Security</strong> <strong>Center</strong> Patroller Plate Reader Server<br />
5.0 <strong>5.1</strong> Federations 5.0 <strong>5.1</strong> 5.0 <strong>5.1</strong><br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> Yes a Yes a 4.0, 5.0 SR1, <strong>5.1</strong> Yes b Yes Yes b Yes<br />
Patroller <strong>5.1</strong> <strong>SR2</strong> No Yes NA NA NA No Yes<br />
Plate Reader Server <strong>5.1</strong><br />
<strong>SR2</strong><br />
Yes Yes NA No Yes NA NA<br />
a. See "<strong>Security</strong> <strong>Center</strong> backward compatibility" on page 53.<br />
b. Connects to <strong>5.1</strong> server with limited features.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 52<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
<strong>Security</strong> <strong>Center</strong> backward compatibility<br />
<strong>Security</strong> <strong>Center</strong> backward compatibility<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> is backward compatible with many <strong>Security</strong> <strong>Center</strong> 5.0 GA/ SR1<br />
components, allowing the system administrator to upgrade the system in stages.<br />
This section includes the following topics:<br />
• "<strong>Security</strong> <strong>Center</strong> backward compatibility requirements" on page 53<br />
• "Backward compatibility between <strong>Security</strong> <strong>Center</strong> roles" on page 53<br />
• "Backward compatibility with <strong>Security</strong> Desk tasks" on page 54<br />
<strong>Security</strong> <strong>Center</strong> backward compatibility requirements<br />
The requirements for <strong>Security</strong> <strong>Center</strong> backward compatibility are as follows:<br />
• Upgrading to <strong>latest</strong> version. If upgrading to the <strong>latest</strong> version (for example, from 5.0<br />
to <strong>5.1</strong>), then you must always upgrade the main server hosting the Directory role and<br />
Config Tool.<br />
• Upgrading to <strong>latest</strong> service release. If upgrading to the <strong>latest</strong> service release (for<br />
example, <strong>5.1</strong> GA to <strong>SR2</strong>) then you do not need to upgrade the main server hosting the<br />
Directory role and Config Tool.<br />
• Using new features. A <strong>Security</strong> <strong>Center</strong> server must be upgraded in order to use the<br />
new features introduced in version <strong>5.1</strong> <strong>SR2</strong>.<br />
• Role is assigned to multiple servers. If a role is assigned to multiple servers, such as in<br />
a failover configuration, all its servers must be running the same version of <strong>Security</strong><br />
<strong>Center</strong>.<br />
Backward compatibility between <strong>Security</strong> <strong>Center</strong> roles<br />
Each new release of <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> includes new role features that may or may not be<br />
compatible with earlier versions. The backward compatibility with <strong>Security</strong> <strong>Center</strong> roles is<br />
summarized in the following table.<br />
Role type Backward compatible to 5.0<br />
Media Router<br />
Access Manager<br />
Archiver<br />
Auxiliary Archiver<br />
No<br />
Yes<br />
Yes<br />
NA(only introduced in <strong>5.1</strong> GA)<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 53<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
<strong>Security</strong> <strong>Center</strong> backward compatibility<br />
Role type Backward compatible to 5.0<br />
Active Directory<br />
Intrusion Manager<br />
<strong>Security</strong> <strong>Center</strong> Federation<br />
Omnicast Federation<br />
Plugin Manager<br />
LPR Manager<br />
Point of Sale<br />
Directory Manager<br />
Health Monitor<br />
Global Cardholder<br />
Synchronizer<br />
Yes<br />
IMPORTANT Since the Active Directory role<br />
is a single instance role in 5.0, you need to<br />
upgrade the old server to <strong>5.1</strong> <strong>SR2</strong> before you<br />
can add additional instances of this role to<br />
your new system<br />
Yes<br />
Yes<br />
Yes<br />
No<br />
No<br />
No<br />
NA (only introduced in <strong>5.1</strong> GA)<br />
NA (only introduced in <strong>5.1</strong> GA)<br />
NA (only introduced in <strong>5.1</strong> GA)<br />
Backward compatibility with <strong>Security</strong> Desk tasks<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> backward compatibility with <strong>Security</strong> Desk 5.0 tasks is summarized<br />
in the following table.<br />
Task category<br />
Task type<br />
Backward compatibility to<br />
<strong>Security</strong> Desk 5.0<br />
Operation Monitoring a Yes<br />
Cardholder management<br />
Visitor management<br />
People counting<br />
Crendential management<br />
Hotlist and permit editor<br />
Inventory management<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
No<br />
No<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 54<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
<strong>Security</strong> <strong>Center</strong> backward compatibility<br />
Task category<br />
Task type<br />
Backward compatibility to<br />
<strong>Security</strong> Desk 5.0<br />
Investigation Incidents Yes<br />
Investigation<br />
/Access control<br />
Investigation<br />
/Asset management<br />
Investigation<br />
/Intrusion detection<br />
Zone activities<br />
Transactions<br />
Area activities<br />
Door activities<br />
Cardholder activities<br />
Visitor activities<br />
Area presence<br />
Time and attendance<br />
Credential activities<br />
Elevator activities<br />
Visit details<br />
Asset activities<br />
Asset inventory<br />
Intrusion detection area activities<br />
Intrusion detection unit events<br />
Yes<br />
No<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
No<br />
No<br />
Yes<br />
Yes<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 55<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
<strong>Security</strong> <strong>Center</strong> backward compatibility<br />
Task category<br />
Investigation<br />
/LPR<br />
Task type<br />
Hits<br />
Reads<br />
Backward compatibility to<br />
<strong>Security</strong> Desk 5.0<br />
No<br />
No<br />
Route playback<br />
No<br />
Inventory report<br />
No<br />
Daily usage per Patroller<br />
No<br />
Logons per Partroller<br />
No<br />
Reads/hits per day<br />
No<br />
Reads/hits per zone<br />
No<br />
Zone occupancy<br />
No<br />
Investigation Archives Yes<br />
/Video b Bookmarks<br />
Yes<br />
Motion search<br />
Camera events<br />
Forensic search<br />
Yes<br />
Yes<br />
NA<br />
Maintenance System status Yes<br />
Audit trails<br />
Activity trails<br />
Health history (5.0)<br />
Health history (<strong>5.1</strong>)<br />
Health statistics<br />
Yes<br />
Yes<br />
Yes – The <strong>Security</strong> Desk 5.0 Heath<br />
history task has been renamed to<br />
Access control health history.<br />
NA – The Health history is a new<br />
task.<br />
NA<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 56<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
<strong>Security</strong> <strong>Center</strong> backward compatibility<br />
Task category<br />
Maintenace<br />
/Access control<br />
Maintenance<br />
/Video<br />
Task type<br />
Access control unit events<br />
Cardholder access rights<br />
Door troubleshooter<br />
Access control unit configuration<br />
Access rule configuration<br />
Cardholder configuration<br />
Credential configuration<br />
IO configuration<br />
Archiver events<br />
Archiver storage details<br />
Backward compatibility to<br />
<strong>Security</strong> Desk 5.0<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Alarm management Alarm monitoring Yes – Moved to Operation tasks.<br />
Alarm report<br />
Yes – Moved to Investigation tasks.<br />
a. Includes live video and playback.<br />
b. These tasks are compatible with the 5.0 SR1 Hardware Integration Package 1 (build<br />
5.0.4792.165). This package is available on GTAP and instructions on how to install the<br />
package are available in the 5.0 SR1 Hardware Integration Package 1 <strong>Release</strong> <strong>Notes</strong>.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 57<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Omnicast compatibility<br />
Omnicast compatibility<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> is compatible with the following Omnicast components.<br />
Omnicast 4.x<br />
Archiver<br />
service<br />
without Archiver<br />
service<br />
more than 30<br />
cameras<br />
Omnicast<br />
federations<br />
<strong>Security</strong> <strong>Center</strong><br />
<strong>5.1</strong> <strong>SR2</strong><br />
No a<br />
Yes b<br />
No c<br />
4.6, 4.7, and<br />
4.8 d<br />
a. The <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> Archiver role and the Omnicast 4.x Archiver service cannot run<br />
on the same server.<br />
b. If the Archiver role is not running on the Omnicast server, then <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> can<br />
coexist on the same server as Omnicast.<br />
c. If Omnicast supports more than 30 cameras, it is best practice to host <strong>Security</strong> <strong>Center</strong><br />
and Omnicast on different computers.<br />
d. The <strong>Security</strong> <strong>Center</strong> Media Router cannot stream video from federated Omnicast systems.<br />
Video streams from federated Omnicast systems are streamed directly to the <strong>Security</strong><br />
Desk client using the Omnicast Compatibility Pack. This means that the <strong>Security</strong><br />
Desk client must be able to connect directly to the Omnicast server. For information<br />
about installing the Omnicast Compatibility Pack, see the <strong>Security</strong> <strong>Center</strong> Installation<br />
and Upgrade Guide, available at: http://downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<br />
<strong>SR2</strong>/<strong>Security</strong>_<strong>Center</strong>/EN.<strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide <strong>5.1</strong> <strong>SR2</strong>.pdf.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 58<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
Sharp model compatibility<br />
Sharp model compatibility<br />
Plate Reader Server <strong>5.1</strong> <strong>SR2</strong> is compatible with the following Sharp models and firmware.<br />
NOTE If your Sharp is running Plate Reader Server 5.0 or earlier you cannot push upgrades<br />
from <strong>Security</strong> <strong>Center</strong>. Instead, you'll need to run the Upgrade tool directly on the Sharp. For<br />
more information about upgrading Sharps, contact your <strong>Genetec</strong> representative.<br />
Sharp<br />
(1.5, 2.0)<br />
SharpEX<br />
(2.0)<br />
Sharp<br />
VGA<br />
SharpX<br />
SharpX<br />
VGA<br />
Plate Reader Server<br />
<strong>5.1</strong> <strong>SR2</strong><br />
Yes a<br />
Yes b<br />
Yes Yes Yes<br />
a. Sharp versions 1.5 and 2.0 with 512 MB of RAM do not support upgrading from <strong>Security</strong><br />
<strong>Center</strong> Config Tool. Instead, you'll need to run the Upgrade tool directly on the Sharp.<br />
For more information about upgrading Sharps, contact your <strong>Genetec</strong> representative.<br />
b. If you are using EX model Sharps with the Patroller, only one LPR camera can be used<br />
per unit.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 59<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
<strong>Security</strong> <strong>Center</strong> Mobile compatibility<br />
<strong>Security</strong> <strong>Center</strong> Mobile compatibility<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> is compatible with <strong>Security</strong> <strong>Center</strong> Mobile 3.0 GA.<br />
NOTE In <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong>, the Synergis Web Client is replaced by <strong>Security</strong> <strong>Center</strong><br />
Web Client, a client component of <strong>Security</strong> <strong>Center</strong> Mobile.<br />
For more information about <strong>Security</strong> <strong>Center</strong> Mobile, see the <strong>Security</strong> <strong>Center</strong> Mobile User<br />
Guide 3.0 GA, available at: http://downloads.genetec.com/Mobile/3.0/GA/EN.<strong>Security</strong><br />
<strong>Center</strong> Mobile User Guide 3.0 GA.pdf.<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 60<br />
EN.500.001-V<strong>5.1</strong>.C2(1)
About the documentation in this release<br />
About the documentation in this release<br />
Documents added<br />
This section describes the documents that were added, updated, or replaced in <strong>Security</strong><br />
<strong>Center</strong> <strong>5.1</strong><strong>SR2</strong>.<br />
This section includes the following topics:<br />
• "Documents added" on page 61<br />
• "Documentation languages" on page 61<br />
The following documents were added in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong><strong>SR2</strong>:<br />
• Getting Started with <strong>Security</strong> Desk User Guide. Task-oriented introduction to <strong>Security</strong><br />
Desk that uses real-world scenarios (viewing a camera, searching/exporting video,<br />
and managing alarms) to show new users how to use the basic product features. This<br />
guide was updated with access control features.<br />
• AutoVu Patroller City Parking Enforcement User Guide. Quick reference guides to<br />
using Patroller in City Parking Enforcement, and City Parking Enforcement with<br />
Wheel Imaging.<br />
• AutoVu Patroller University Parking Enforcement User Guide. Quick reference<br />
guides to using Patroller in University Parking Enforcement.<br />
Documentation languages<br />
<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>SR2</strong> documentation is available in the following languages:<br />
• All documentation is available in English.<br />
• The following documents are available in French:<br />
• <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong><br />
• AutoVu Patroller <strong>Release</strong> <strong>Notes</strong><br />
• AutoVu Hardware <strong>Release</strong> <strong>Notes</strong><br />
• AutoVu Patroller User Guides<br />
• AutoVu Handbook<br />
• <strong>Security</strong> Desk User Guide<br />
• <strong>Security</strong> <strong>Center</strong> Administrator Guide<br />
• The following documents are available in Spanish:<br />
• <strong>Security</strong> Desk User Guide<br />
• Getting Started with <strong>Security</strong> Desk<br />
genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>SR2</strong> | <strong>Download</strong> <strong>latest</strong> version 61<br />
EN.500.001-V<strong>5.1</strong>.C2(1)