29.10.2014 Views

Spinal Surgery, Cement Systems - Orthoworld

Spinal Surgery, Cement Systems - Orthoworld

Spinal Surgery, Cement Systems - Orthoworld

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PRODUCT NEWS AND LAUNCHES<br />

Locking Plate for Hallux Valgus<br />

Correction using Ludloff<br />

Osteotomy<br />

Globus Medical commenced global launch of the<br />

COALITION ACDF Spacer System, an integrated plate and<br />

spacer for use in anterior cervical discectomy and fusion. The<br />

COALITION technology combines a PEEK interbody spacer<br />

with a titanium alloy plate and two titanium alloy screws. The<br />

delivery system and two-screw design reduce procedural steps,<br />

minimize retraction and lag the spacer to the vertebral<br />

endplates to compressively load the fusion area.<br />

(Globus Medical, Inc., 6/2/09)<br />

SpineMatrix launched Lumbar Matrix Scan, a non-invasive<br />

diagnostic technology that uses bioelectric signals produced by<br />

muscles to accurately identify the source of low back pain.<br />

(SpineMatrix Inc., 6/10/09)<br />

HydroCision launched the SpineJet Percutaneous Access Set<br />

for use in herniated disc procedures. The system uses a high<br />

velocity water jet to cut and remove nucleus material under<br />

local anesthesia and on an outpatient basis.<br />

(HydroCision Inc., 6/15/09)<br />

The new Merete Ludloff plate allows the surgeon to obtain<br />

RIGID LOW PROFILE fixation for Hallux Valgus correction<br />

using the familiar Ludloff osteotomy technique. Previous fixation<br />

with only 2 screws required non-weightbearing post op<br />

care. The Merete Ludloff plate allows for angle stable fixation.<br />

The Merete Ludloff plate is a patented design with locking<br />

and non-locking holes. The straight section of the plate is<br />

placed dorsally on the metatarsal where the plate is fixed to<br />

the bone with two 3.0 mm non-locking cannulated screws.<br />

First screw located through the plate at the apex/rotation<br />

point of Ludloff cut and second non-locking screw is placed<br />

distal after cut completion and lateral rotation for correction.<br />

The screws can be angled up to 12° in the plate in order to run<br />

perpendicular to the osteotomy cut, compressing the osteotomy.<br />

Two locking screws 3.0 mm or 3.5 mm are inserted from<br />

the medial side to gain angle stable locking fixation of the<br />

osteotomy and to allow early weightbearing.<br />

• 3 low profile plate lengths are available (31 mm, 34 mm<br />

and 38 mm).<br />

• Plates and screws are manufactured from Titanium alloy<br />

Ti-6Al-4V.<br />

The patented Merete Ludloff plate has been developed in<br />

collaboration with Steven K. Neufeld, M.D., Orthopedic Foot<br />

and Ankle Center of Washington.<br />

Merete Medical GmbH<br />

Tel.: 49-30-77-99-80-149<br />

www.merete.de<br />

LifeModeler released LumbarSIM, an addition to its virtual<br />

prototyping software portfolio. LumbarSIM automatically<br />

creates a detailed lumbar spine model, separating it into<br />

individual vertebral segments and disc forces for use in preoperative<br />

planning for spinal fusion, discectomy and<br />

laminectomy. Reports generated by the software allow for<br />

incorporation of hypertext, plots, live video and model<br />

animation. The software’s operational characteristics are<br />

designed to mirror the workflow commonly found on a personal<br />

computer.<br />

(LifeModeler, Inc., 6/23/09)<br />

K2M launched CASPIAN, an all-inclusive system for rigid<br />

posterior fixation in the treatment of complex cervico-thoracic<br />

conditions. CASPIAN provides 2 different polyaxial screw<br />

options, the Mini DENALI® and Mini MESA®, for intraoperative<br />

flexibility. Mini MESA features K2M’s Zero-Torque<br />

Technology® which applies zero twisting forces to the spine<br />

when locking the system.<br />

(K2M, Inc., 6/30/09)<br />

ArthroCare launched the Opus® AutoCuff® Magnum M Suture<br />

Anchor. The device is designed to provide a simpler, faster and<br />

replicable process for performing arthroscopic rotator cuff repair.<br />

(ArthroCare Corp., 7/1/09)<br />

CONMED Linvatec launched the Linvatec Shoulder<br />

Restoration System (SRS) for rotator cuff repair. The SRS allows<br />

the surgeon to intra-operatively choose from multiple surgical<br />

techniques, including single row, double row and transosseous<br />

equivalent fixation. Elements include the PEEK-based<br />

CrossFT Fully Threaded and PopLok Knotless Suture<br />

Anchors and titanium Super Revo-FT and ThRevo-FT<br />

Fully Threaded Suture Anchors.<br />

(CONMED Corporation, 7/7/09)<br />

22 ORTHOPAEDIC PRODUCT NEWS • September/October 2009