MULTIPLE SPLIT TYPE AIR CONDITIONERS<br />

Series<br />

CM05EU4-E


High COP (energy consumption efficiency)<br />

Achieved Top class in the Industry<br />

Comparison of COP (energy consumption efficiency) <br />

COP<br />

4.0<br />

3.5<br />

3.0<br />

2.5<br />

2.0<br />

0<br />

2.58<br />

50%<br />

Energy<br />

saving<br />

Our equivalent<br />

product 10 years<br />

before<br />

3.39<br />

CITY MULTI<br />

14.5%<br />

Energy<br />

saving<br />

3.88<br />

Comparing to the current energy<br />

saving type,<br />

COP upgraded by about 15%!<br />

Comparing to our equivalent product<br />

10 years before,<br />

COP upgraded by about 50%!<br />

(10HP equivalent model)<br />

Inverter driven outdoor fan motor<br />

newly employed!<br />

R410A highly efficient inverter<br />

compressor employed!<br />

• Improvement of<br />

heat exchanger performance<br />

• Newly designed refrigerant circuit<br />

(low pressure loss)<br />

Resulting in Total Energy<br />

Conservation<br />

Heating operation range covers an outdoor<br />

temperature of down to -20˚C (wet bulb temperature)<br />

Operating range in<br />

cooling is from an<br />

outdoor temperature<br />

of -5˚C, while that in<br />

heating has<br />

expanded to an<br />

outdoor temperature<br />

of -20˚C!<br />

The operation range<br />

can now cover even<br />

cold regions.<br />

✻ -12˚C~15˚C for<br />

PUMY series.<br />

-20˚C<br />

✻<br />

Operable even in<br />

very cold regions<br />

Outdoor temperature<br />

(wet bulb temperature)<br />

Under cooling<br />

-5˚C<br />

Under heating<br />

15.5˚C<br />

Outdoor temperature<br />

(dry bulb temperature)<br />

-20 -10 0 10 20 30 40<br />

✻<br />

43˚C


High static pressure of 60Pa<br />

achieved, the industry top class*<br />

Flexibility in air conditioning design has been enlarged with a high static<br />

pressure of 60Pa.<br />

(except PUMY series)<br />

*Optional parts<br />

Facilitated connection<br />

of supply hood<br />

Outdoor unit packing<br />

without using wooden materials<br />

The use of wooden frame for the transport of the outdoor unit has been discontinued. The structure is so designed that the unit can be<br />

transported with a forklift not using wooden frames or pallets. This contributes in reducing waste and preserving the global environment.<br />

Eliminating wood consumption<br />

thanks to the wooden packing<br />

discontinued.<br />

Transportable by a forklift<br />

without using pallets.<br />

Night Mode Quiet<br />

operation can reduce<br />

sound level of 8dB!<br />

(10HP)<br />

CITYMULTI Series Night mode quiet<br />

operation can reduce sound level by<br />

sensing ambient temperature condition.<br />

57dB<br />

49dB<br />

(10HP)<br />

above<br />

30˚C<br />

below<br />

30˚C<br />

Front and rear double<br />

suction structure<br />

The front and rear double suction structure<br />

provides the smooth airflow to reduce the<br />

pressure loss, which results in low noise.<br />

Air passage and machine<br />

compartment separated<br />

The machine compartment is sealed up to<br />

attain the low noise level in all directions.<br />

(except PUMY series)<br />

“All<br />

Directions”<br />

*Needs to set night mode setting at the site.<br />

*Night mode could be turn off automatically due to ambient<br />

temperature and required capacity load condition.


Series provide<br />

for air conditioning comfort with<br />

MITSUBISHI ELECTRIC's<br />

leading edge technologies.<br />

Less cold draught,<br />

More comfort<br />

Only with<br />

MITSUBISHI<br />

ELECTRIC<br />

CITYMULTI Series can change the target evaporating<br />

temperature during cooling mode.<br />

Unit with higher off coil temperature can offer more comfort due<br />

less chance of cold draughts.<br />

Conventional Model CITYMULTI Series<br />

Cooling Operation<br />

Set Temperature<br />

of 14˚C<br />

(except PUMY series)<br />

By selecting a dip switch on the<br />

unit, a cooling operation set<br />

temperature of 14˚C is possible on<br />

the floor standing and ceiling<br />

concealed models. Suitable for<br />

lower set temperature applications<br />

like Gymnasiums etc,,,.<br />

Only with<br />

MITSUBISHI<br />

ELECTRIC


High-capacity<br />

reluctance DC motor<br />

drive compressor<br />

Motor efficiency greatly improved +<br />

Reduced suction refrigerant heating loss<br />

Anti-Corrosion<br />

Blue Fin as a<br />

Standard!<br />

CITYMULTI Series will<br />

have an Anti-Corrosion heat<br />

exchanger (Blue Fin) as a<br />

standard.<br />

Industry Top class<br />

Low Noise Design<br />

New Fan Design<br />

City Multi Y/R2 VRF systems led the introduction of larger single fan rotors<br />

some ten years ago and achieved substantially lower noise levels over<br />

multiple designs. Continuing development in the areas of blade shape and<br />

weight has achieved higher performance and lower noise level.<br />

Conventional model fan<br />

New model fan


Mitsubishi Electric<br />

City Multi<br />

Series<br />

– towards a new era of<br />

highly advanced air conditioning –<br />

As a market leading company,<br />

Mitsubishi Electric offers the<br />

"State of the Art" City Multi<br />

VRF<br />

system, adopting<br />

advanced refrigeration & control<br />

technology, thereby achieving<br />

high performance and ultimate<br />

design flexibility.<br />

1


Series Product Lineup<br />

New<br />

Outdoor Unit<br />

Air Cooled System<br />

4HP 5HP 6HP 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP<br />

Heat Pump<br />

Heat Recovery<br />

28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HP<br />

Heat Pump<br />

Water Cooled System<br />

8HP 10HP 16HP 20HP<br />

Heat Pump<br />

Heat Recovery<br />

PLFY-P VCM-E/VAM-E<br />

........p.27, 28 / 41, 42<br />

Indoor Unit<br />

PEFY-P VMH-E<br />

........p.35 / 51, 52<br />

PLFY-P VLMD-E<br />

........p.29 / 43, 44<br />

PMFY-P VBM-E<br />

........p.30 / 45<br />

PEFY-P VMR-E-L/R<br />

New ........p.31 / 46<br />

New<br />

PEFY-P VMS-E<br />

........p.32 / 47<br />

PEFY-P VML-E<br />

........p.33 / 48<br />

New<br />

PCFY-P VGM-E<br />

........p.36 / 53<br />

PKFY-P VAM-E/VGM-E<br />

/VFM-E<br />

........p.37 / 54, 55<br />

PFFY-P VKM-E<br />

........p.38 / 56<br />

PFFY-P VLEM-E/VLRM-E<br />

........p.39 / 57, 58<br />

PEFY-P VMM-E<br />

........p.34 / 49, 50<br />

PEFY-P VMH-E-F<br />

........p.40 / 59, 60<br />

Lossnay/OA Processing Units<br />

Air Conditioning MANAGEMENT SYSTEM<br />

2


FEATURES<br />

Effective space utilization thanks to a<br />

small installation space.<br />

The installation space of the outdoor unit has<br />

greatly been reduced. The reduction counts for<br />

about 33%* maximum comparing to our<br />

conventional CITY MULTI Series.*24·26HP outdoor units<br />

conventional CITY MULTI<br />

24<br />

26<br />

2990<br />

450<br />

840<br />

840<br />

450 450 33%<br />

1990<br />

HP<br />

5.20m 2 3.46m 2<br />

450<br />

reduction<br />

Effective utilization of vacant spaces<br />

The compact design<br />

and isolated installation<br />

of each unit allow<br />

utilization of vacant<br />

spaces effectively.<br />

Easy installation<br />

even in a<br />

narrow space<br />

Outdoor unit installation space (including service space)<br />

*Image of 28~32HP system<br />

4~6HP 8~14HP 16HP 18~26HP 28~32HP 34~50HP NEW<br />

1unit<br />

1unit<br />

1unit<br />

1unit<br />

2units<br />

2units<br />

Installation Space Air Cooled<br />

630<br />

10 950 10<br />

150<br />

330<br />

150<br />

1740<br />

990<br />

450<br />

840<br />

450<br />

1740<br />

1290<br />

450<br />

840<br />

450<br />

0.61m 2 1.72m 2 2.24m 2 3.46m 2 3.74(4.14)m 2<br />

1740<br />

1990<br />

450<br />

840<br />

450<br />

1390<br />

(1540)<br />

10 990 1690<br />

2690<br />

100<br />

(250)<br />

840<br />

450<br />

10<br />

1990 1990<br />

450<br />

840<br />

450<br />

6.94m 2<br />

8HP<br />

WY Series (Heat Pump)<br />

WR2 Series (Heat Recovery)<br />

10HP 16HP 20HP 8HP 10HP 16HP 20HP<br />

Water Cooled<br />

Installation Space<br />

(upside piping)<br />

550<br />

450<br />

550<br />

450<br />

550<br />

450<br />

990<br />

1,980<br />

990<br />

1,980<br />

0.99m 2 1.98m 2 0.99m 2 1.98m 2<br />

550<br />

450<br />

3<br />

Easy carrying-in by single package design<br />

Reduced carrying-in process thanks to the single package configuration<br />

For lifting up to building rooftop with a crane<br />

For field<br />

combining type<br />

As the lifting up and<br />

down operation is<br />

repeated frequently, the<br />

installation work longer.<br />

One<br />

shot<br />

The CITY MULTI<br />

(4~26HP) can be<br />

delivered in one go,<br />

thus allowing far<br />

speedier installation.


The World's First and Only "2-Pipe" Heat Recovery System<br />

The Innovative BC Controller Which Makes a 2-pipe System Possible<br />

BC Controller Operation<br />

R2 WR2<br />

Operation primarily for cooling<br />

Operation primarily for cooling<br />

Outdoor unit BC controller<br />

Switching valve Indoor unit<br />

4-way valve Check valve<br />

High<br />

pressure<br />

gas<br />

Heat<br />

exchanger<br />

Compressor<br />

Low pressure gas<br />

Low pressure pipe<br />

High<br />

pressure gas<br />

Fan Gas/liquid<br />

separator<br />

High pressure 2-phase<br />

High pressure pipe<br />

LEV<br />

Low pressure 2-phase<br />

High pressure liquid<br />

Cooling<br />

Cooling<br />

Cooling<br />

Heating<br />

Total heat recovery operation<br />

Total heat recovery operation<br />

Low pressure gas<br />

High pressure gas<br />

Low pressure gas<br />

Low pressure 2-phase<br />

High pressure liquid<br />

High pressure 2-phase<br />

Low pressure gas<br />

High<br />

pressure gas<br />

High<br />

pressure gas<br />

Heating<br />

Heating<br />

Low pressure gas<br />

Cooling<br />

Cooling<br />

Low pressure gas Low pressure 2-phase<br />

High pressure liquid<br />

R2 WR2<br />

Achieving smallest number<br />

of pipework connection<br />

thanks to 2-pipe system<br />

Comparison of piping connection =2 connections =3 connections<br />

City Multi R2/WR2 Total number of connections<br />

20<br />

Outdoor unit<br />

BC Controller<br />

Heat Recovery System can<br />

create maximum of 15HP<br />

capacity from 10HP unit!<br />

The waste heat recovery system in the refrigerant system increases the energysaving<br />

effect as the cooling and heating simultaneous operation is carried out.<br />

Indoor unit output<br />

A Heating 10HP, Cooling 5HP, Total 15HP<br />

B Heating 7.5HP, Cooling 7.5HP, Total 15HP<br />

Cooling 10HP<br />

C Cooling capacity of each indoor<br />

unit is approx. 10/15 of the rating.<br />

( )<br />

R2 WR2<br />

Outdoor unit<br />

input<br />

10HP Cooling 5HP: Waste heat utilized<br />

7.5HP Optimum operation pattern<br />

In the same mode, the<br />

10HP compressor capacity is the<br />

maximum output<br />

(in this case 10HP).<br />

Indoor unit<br />

Operation pattern of<br />

New City Multi R2 System<br />

15HP<br />

( )<br />

Total 15HP indoor<br />

unit is connected with<br />

10HP outdoor unit.<br />

The total number of connections for City Multi R2 is only<br />

68 when the 16 indoor units are installed.<br />

3-pipe type<br />

Outdoor unit<br />

Branch unit<br />

Indoor unit<br />

Number of branches<br />

4<br />

10<br />

16<br />

2-pipe type<br />

20<br />

44<br />

68<br />

Total number of connections<br />

58<br />

3-pipe type<br />

58<br />

154<br />

–<br />

The more frequently cooling and heating simultaneous<br />

operation is carried out, the higher the energy-saving effect is.<br />

COP in heat recovery operation<br />

Energy consumption efficiency (COP)<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

Heating indoor unit<br />

Cooling and heating<br />

simultaneous and primarily<br />

cooling operation<br />

10HP<br />

7.5HP<br />

5HP<br />

A Primarily heating operation<br />

5HP 7.5HP 10HP<br />

Cooling indoor unit<br />

Cooling and heating balance operation<br />

Cooling and heating<br />

simultaneous and primarily<br />

heating operation<br />

Cooling and heating non-simultaneous model<br />

B Total heat recovery operation<br />

15HP<br />

20 40 60 80 100 Heating<br />

ratio<br />

C<br />

R2 WR2<br />

4


FEATURES<br />

Downsizing of refrigerant<br />

piping connections<br />

By making the connection diameter of refrigerant piping<br />

(10HP system)<br />

smaller, the piping space can be minimized, and the ease of field<br />

installation. Workability upgraded and the piping materials reduced.<br />

Comparison of piping size (for 10HP system) List of major piping sizes<br />

Conventional type<br />

Gas<br />

piping<br />

φ28.58<br />

Liquid<br />

piping<br />

φ12.7<br />

CITY MULTI<br />

type<br />

Gas<br />

piping<br />

φ22.2<br />

Liquid<br />

piping<br />

φ9.52<br />

System capacity<br />

4~6HP system<br />

8HP system<br />

10/12HP system<br />

14HP system<br />

16HP system<br />

18~26HP system<br />

28~32HP system<br />

34~50HP system<br />

Gas piping : downed by 2 sizes<br />

Liquid piping : downed by 1 size<br />

Significant reduction of field piping connections<br />

The single package design eliminates the oil equalizing pipe and<br />

the piping between outdoor units, thus upgrading the reliability,<br />

reducing complexity and reducing the installation cost.<br />

Liquid piping<br />

φ9.52<br />

φ12.7<br />

φ15.88<br />

φ19.05<br />

Gas piping<br />

φ15.88<br />

φ19.05<br />

φ22.2<br />

φ28.58<br />

φ34.93<br />

φ41.28<br />

Eliminating the<br />

oil equalizing pipe<br />

(8~32HP)<br />

4~14HP 16HP 18~26HP 28~32HP 34~50HP NEW<br />

Oil equalizing<br />

pipe not<br />

required<br />

Liquid piping<br />

Gas<br />

piping<br />

Piping between<br />

units not<br />

required<br />

Liquid<br />

piping<br />

Gas piping<br />

Gas piping<br />

Liquid<br />

piping<br />

Oil equalizing<br />

pipe not<br />

required<br />

Oil equalizing<br />

piping<br />

Liquid<br />

piping<br />

Gas<br />

piping<br />

Connection spot : 2<br />

Connection spot : 6 Connection spot : 12<br />

*The actual product may differ from the photo.<br />

Upgrading reliability by minimizing the number<br />

of parts and providing back up function<br />

18~26HP 28~32HP 34~50HP NEW<br />

In case of one<br />

compressor fails,<br />

In case of one<br />

compressor fails,<br />

Alternate<br />

operation<br />

Facilitating<br />

maintenance work by<br />

minimizing the number<br />

of parts, and<br />

upgrading reliability by<br />

simplifying<br />

construction designed<br />

Compressor<br />

Compressor<br />

Compressor<br />

backup operation<br />

Compressor<br />

Compressor<br />

Compressor<br />

backup operation<br />

Backup<br />

operation<br />

In case of<br />

malfunction<br />

mulfunction<br />

5


Realizing refrigerant piping total length of<br />

400m* top class in industry *CITY MULTI R2 Series<br />

S Series (4~6HP)<br />

Refrigerant Piping Restrictions<br />

Total length........................................................<br />

Furthest length..................................................<br />

Furthest length after first branch.......................<br />

Top-bottom differentials between units<br />

Between indoor unit and outdoor unit<br />

(outdoor unit is upper)......................................<br />

Between indoor unit and outdoor unit<br />

(outdoor unit is lower)........................................<br />

Between indoor units.........................................<br />

120m or less<br />

80m or less<br />

30m or less<br />

30m or less<br />

20m or less<br />

12m or less<br />

Y Series (8~32HP)<br />

Refrigerant Piping Restrictions<br />

Total length........................................................<br />

Furthest length..................................................<br />

Furthest length [equivalent length]...................<br />

Furthest length after first branch.......................<br />

Top-bottom differentials between units<br />

Between indoor unit and outdoor unit<br />

(outdoor unit is upper)......................................<br />

300m or less<br />

150m or less<br />

175m or less<br />

40m or less<br />

50m or less<br />

Between indoor unit and outdoor unit<br />

(outdoor unit is lower)........................................ 40m or less*<br />

Between indoor units......................................... 15m or less<br />

* 4m or less in cooling at outdoor temperature 0˚C or lower.<br />

Y Series (34~50HP)<br />

Refrigerant Piping Restrictions<br />

Total length........................................................<br />

Furthest length..................................................<br />

Furthest length [equivalent length]...................<br />

Furthest length after first branch.......................<br />

Between Main and Sub outdoor unit.................<br />

Top-bottom differentials between units<br />

Between indoor unit and outdoor unit<br />

(outdoor unit is upper)......................................<br />

300m or less<br />

150m or less<br />

175m or less<br />

40m or less<br />

4m or less<br />

50m or less<br />

Between indoor unit and outdoor unit<br />

(outdoor unit is lower)........................................ 40m or less*<br />

Between indoor units......................................... 15m or less<br />

Between Main and Sub outdoor unit................. 0.1m or less<br />

* 4m or less in cooling at outdoor temperature 0˚C or lower.<br />

Y Series<br />

Top-bottom differential 50m<br />

Indoor unit<br />

Top-bottom differential 50m<br />

Outdoor unit<br />

Furthest piping length<br />

175m (equivalent length)<br />

(actual length 150m)<br />

between indoor units<br />

top-bottom differential<br />

15m<br />

Outdoor unit<br />

Furthest piping length<br />

175m (equivalent length)<br />

(actual length 150m)<br />

Indoor unit<br />

between indoor units<br />

top-bottom differential<br />

15m<br />

6


FEATURES<br />

Realizing refrigerant piping total length of<br />

400m* top class in industry *CITY MULTI R2 Series<br />

R2 Series (P200, P250, P300, P350 type)<br />

Refrigerant Piping Restrictions<br />

Total length............................................................ 300m or less (400m) *2<br />

Furthest length...................................................... 150m or less<br />

Furthest length [equivalent length]........................ 175m or less<br />

Difference between outdoor unit and<br />

BC controller unit................................................... 110m or less<br />

Difference between BC controller<br />

main-unit and furthest indoor unit....................... 40m or less *3<br />

Top-bottom differentials between units<br />

Between indoor unit and outdoor unit (outdoor unit is upper).... 50m or less<br />

Between indoor unit and outdoor unit (outdoor unit is lower)..... 40m or less<br />

Between indoor unit and BC controller................... 15m or less (10m) *1<br />

Between indoor units............................................. 15m or less (10m) *1<br />

*1. Value in ( ) is applied to the P200/P250 type indoor unit.<br />

*2. Please refer to 'refrigerant piping limits' (see the figure) in case of the total length is greater than 300m.<br />

*3. Please refer to 'Limits between BC controller - indoor unit' (see the figure) in case of the piping length between<br />

BC controller and furthest indoor unit is greater than 40m (except P250 indoor unit).<br />

*4. Do not use joint or header for P200/P250 type indoor unit.<br />

*5. Do not connect P200/P250 type indoor unit with the indoor unit of any other capacity at a same branch port.<br />

R2 Series<br />

P200, P250, P300, P350 types<br />

Difference of<br />

height 50m<br />

Between indoor unit and<br />

BC controller topbottom<br />

differential 15m<br />

Between indoor unit and<br />

BC controller<br />

top-bottom differential 15m<br />

Outdoor unit<br />

Furthest piping length<br />

175m (equivalent length)<br />

(actual length 150m)<br />

Between indoor units<br />

top-bottom<br />

differential 15m<br />

R2 Series (P200 ~ P650 type)<br />

Refrigerant Piping Restrictions<br />

Total length............................................................ 300m or less (400m) *1<br />

Furthest length...................................................... 150m or less<br />

Furthest length [equivalent length]........................ 175m or less<br />

Difference between outdoor unit and<br />

BC controller main-unit.......................................... 110m or less<br />

Difference between BC controller<br />

main-unit and furthest indoor unit.......................... 40m or less *2<br />

Top-bottom differentials between units<br />

Between indoor unit and outdoor unit [outdoor unit is upper].... 50m or less<br />

Between indoor unit and outdoor unit [outdoor unit is lower]..... 40m or less<br />

Between indoor unit and BC controller................... 15m or less<br />

Between indoor units............................................. 15m or less (10m)*3<br />

Between BC controller main-unit and sub-unit.............. 15m or less<br />

Between indoor unit (BC controller main-unit)<br />

and indoor unit (BC controller sub-unit)....................... 15m or less (10m)*3<br />

* If indoor units (over 16 branches) are connected, two BC controller units are required and there must be three pipes<br />

between BC controllers.<br />

*1. Please refer to 'refrigerant piping limits' (see the figure) in case of the total length is greater than 300m.<br />

*2. Please refer to 'Limits between BC controller - indoor unit' (see the figure) in case of the piping length between<br />

BC controller and furthest indoor unit is greater than 40m (except P250 indoor unit).<br />

*3. Value in ( ) is applied to the P200/P250 type indoor unit.<br />

*4. Do not use joint or header for P200/P250 type indoor unit.<br />

R2 Series<br />

P200 ~ P650 types<br />

Top-bottom<br />

differential 50m<br />

Between indoor unit and<br />

BC controller topbottom<br />

differential 15m<br />

Between indoor unit and<br />

BC controller<br />

top-bottom differential 15m<br />

Outdoor unit<br />

Furthest piping length<br />

175 m (equivalent length)<br />

(actual length 150 m)<br />

Between indoor units<br />

top-bottom<br />

differential 15m<br />

In case of a BC controller unit<br />

(16 branches or less)<br />

• Refrigerant Piping Limits<br />

400<br />

Main pipe and<br />

branch pipe: 2-pipe<br />

Outdoor unit<br />

Piping total lenght (m)<br />

350<br />

300<br />

250<br />

200<br />

30 40 50 60 70 80 90 100 110<br />

Distance between outdoor unit and BC Controller (m)<br />

• Limits between BC contoller - indoor unit<br />

Distance between BC controller (Main) -<br />

furthest indoor unit (m)<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

0 5 10 15<br />

Height differential between BC controller (Main) - furthest indoor unit (m)<br />

Top-bottom<br />

differential<br />

50m or less<br />

Between indoor<br />

units<br />

topbottom<br />

differential<br />

15m or less<br />

Distribution sub-control<br />

Maximum length between indoor unit and<br />

BC controller 40 m or less (2-pipe)<br />

Distribution<br />

control<br />

main-unit<br />

In case of two BC controller units<br />

(Over 16 branches)<br />

110 m or less between outdoor<br />

unit and BC controller (2-pipe)<br />

Three pipes between<br />

BC controllers<br />

Between distribution<br />

controls top-bottom<br />

differential 15m or less<br />

7


Series Product Lineup<br />

Wide variation of outdoor unit to adapt with various applications.<br />

Series<br />

S Series<br />

Type<br />

A<br />

Heat Pump<br />

4HP<br />

PUMY-P100YHM<br />

PUMY-P100VHM<br />

5HP<br />

PUMY-P125YHM<br />

PUMY-P125VHM<br />

6HP<br />

PUMY-P140YHM<br />

PUMY-P140VHM<br />

Series Type<br />

Y Series A<br />

Heat Pump<br />

Cooling Only<br />

R2 Series A Heat Recovery<br />

8HP<br />

PUHY-P200YGM-A<br />

PUY-P200YGM-A<br />

PURY-P200YGM-A<br />

10HP<br />

PUHY-P250YGM-A<br />

PUY-P250YGM-A<br />

PURY-P250YGM-A<br />

12HP<br />

PUHY-P300YGM-A<br />

PUY-P300YGM-A<br />

PURY-P300YGM-A<br />

14HP<br />

PUHY-P350YGM-A<br />

PUY-P350YGM-A<br />

PURY-P350YGM-A<br />

16HP<br />

PUHY-P400YGM-A<br />

–<br />

PURY-P400YGM-A<br />

Series<br />

Y Series<br />

R2 Series<br />

Type<br />

A<br />

A<br />

Heat Pump<br />

Heat Recovery<br />

18HP 20HP 22HP<br />

PUHY-P450YGM-A PUHY-P500YGM-A PUHY-P550YGM-A<br />

PURY-P450YGM-A PURY-P500YGM-A PURY-P550YGM-A<br />

24HP<br />

PUHY-P600YGM-A<br />

PURY-P600YGM-A<br />

26HP<br />

PUHY-P650YGM-A<br />

PURY-P650YGM-A<br />

Series<br />

Y Series<br />

Type<br />

A<br />

28HP 30HP 32HP<br />

Heat Pump PUHY-P700YSGM-A PUHY-P750YSGM-A PUHY-P800YSGM-A<br />

Series<br />

Y Series<br />

Type<br />

A<br />

Heat Pump<br />

34HP<br />

PUHY-P850YSGM-A<br />

36HP<br />

PUHY-P900YSGM-A<br />

38HP 40HP 42HP 44HP 46HP 48HP 50HP<br />

PUHY-P950YSGM-A PUHY-P1000YSGM-A PUHY-P1050YSGM-A PUHY-P1100YSGM-A PUHY-P1150YSGM-A PUHY-P1200YSGM-A PUHY-P1250YSGM-A<br />

Series Type<br />

WY Series W<br />

WR2 Series W<br />

Heat Pump<br />

Heat Recovery<br />

8HP 10HP 16HP 20HP<br />

PQHY-P200YGM-A PQHY-P250YGM-A PQHY-P400YSGM-A PQHY-P500YSGM-A<br />

PQRY-P200YGM-A PQRY-P250YGM-A PQRY-P400YSGM-A PQRY-P500YSGM-A<br />

Type: A =Air Cooled.<br />

W=Water Cooled.<br />

8


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

New<br />

S SERIES<br />

R410A<br />

<strong>Specifications</strong><br />

Model name<br />

Power source<br />

PUMY-P100YHM PUMY-P125YHM<br />

3-phase, 380-400-415V, 50Hz<br />

PUMY-P140YHM<br />

Cooling capacity<br />

(Nominal)<br />

Power input<br />

Current input<br />

COP<br />

*1<br />

*1<br />

*1<br />

*2<br />

kW<br />

kcal / h<br />

Btu / h<br />

kcal / h<br />

kW<br />

A<br />

11.2<br />

9,600<br />

38,200<br />

-<br />

3.30<br />

5.28-5.02-4.84<br />

3.39<br />

14.0<br />

12,000<br />

47,800<br />

12,500<br />

4.27<br />

6.83-6.49-6.26<br />

3.28<br />

15.5<br />

13,300<br />

52,900<br />

14,000<br />

5.32<br />

8.51-8.09-7.80<br />

2.91<br />

Temp. range of<br />

cooling<br />

Heating capacity<br />

(Nominal )<br />

Power input<br />

Current input<br />

COP<br />

Temp. range of Indoor temp.<br />

Heating Outdoor temp.<br />

Indoor unit Total capacity<br />

connectable Model / Quantity<br />

Noise level (measured in anechoic room)<br />

Diameter of Liquid<br />

refrigerant pipe Gas<br />

<strong>External</strong> finish<br />

<strong>External</strong> dimension H ✕ W ✕ D<br />

Net weight<br />

Heat exchanger<br />

Compressor Type<br />

Maker<br />

Starting method<br />

Motor output<br />

Case heater<br />

Standard<br />

attachment<br />

Optional parts<br />

Remark<br />

Indoor<br />

Outdoor<br />

*3<br />

*3<br />

*3<br />

W.B.<br />

D.B.<br />

kW<br />

kcal / h<br />

Btu / h<br />

kW<br />

A<br />

D.B.<br />

W.B.<br />

dB <br />

mm(in.)<br />

mm(in.)<br />

mm<br />

kg<br />

kW<br />

kW<br />

Lubricant ✕ original charge<br />

FAN<br />

Air flow rate m 3 / min<br />

<strong>External</strong> static press.<br />

Type ✕ Quantity<br />

Control, Driving mechanism<br />

Motor output kW<br />

HIC circuit (HIC: Heat Inter-Changer)<br />

Protection High pressure protection<br />

Inverter circuit (COMP. / FAN)<br />

Compressor<br />

Fan motor<br />

Defrosting method<br />

Refrigerant Type x original charge<br />

Control<br />

Document<br />

Accessory<br />

12.5<br />

10,800<br />

42,700<br />

3.63<br />

5.81-5.52-5.32<br />

3.44<br />

P20 ~ P125 / 1 ~ 6<br />

49/51<br />

Note:<br />

*1 Nominal cooling conditions<br />

Indoor: 27˚CDB/19˚CWB (81˚FDB/66˚FWB)<br />

Outdoor 35˚CDB (95˚FDB)<br />

Pipe length: 7.5m (24-9/16ft)<br />

Level difference: 0m (0ft)<br />

* Nominal condition *1, *3 are subject to JIS B8615-1<br />

* Due to continuing improvement, above specifications may be subject to change without notice.<br />

1.9<br />

-<br />

15 ~ 24˚C (59~75˚F)<br />

- 5 ~ 46˚C (23~115˚F)<br />

10 to 46˚C D.B.(50 to 115˚FD.B.) : in case of connecting PKFY-P20/P25 type indoor unit.<br />

16.0<br />

13,800<br />

54,600<br />

4.29<br />

6.87-6.52-6.29<br />

3.73<br />

15~27˚C (59~81˚F)<br />

-12~15˚C (10~59˚F)<br />

50 ~ 130% of outdoor unit capacity<br />

P20 ~ P140 / 1 ~ 8<br />

50/52<br />

φ9.52 (φ3/8" ) Flare<br />

φ15.88 (φ5/38" ) Flare<br />

Galvanized steel sheet<br />

<br />

1,350 ✕ 950 ✕ 330<br />

140<br />

Salt-resistant cross fin & copper tube<br />

Inverter scroll hermetic compressor<br />

Mitsubishi Electric Corporation<br />

Inverter<br />

2.4<br />

-<br />

MEL56 x 2.3 L<br />

100<br />

0 Pa<br />

Propeller fan ✕ 2<br />

DC-control, Direct-driven by motor<br />

0.06 x 2<br />

-<br />

High pressure sensor, High pressure switch 4.15 MPa<br />

Over-heat protection, Over-current protection<br />

Discharge thermo protection, Over-current protection<br />

Over-heat protection, Voltage protection<br />

Auto-defrost mode (Reversed refrigerant circle)<br />

R410A ✕ 8.5kg ( 19 lb)<br />

LEV circuit<br />

Installation Manual<br />

Grounded lead wire ✕ 2<br />

Joint: CMY-Y62G-F ; Header:CMY-Y64/68G-F<br />

18.0<br />

15,500<br />

61,400<br />

5.32<br />

8.51-8.09-7.80<br />

3.38<br />

P20 ~ P140 / 1 ~ 8<br />

51/53<br />

Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual.<br />

*2 Nominal cooling conditions<br />

*3 Nominal heating conditions<br />

27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 20˚CDB (68˚FDB)<br />

35˚CDB (95˚FDB)<br />

7˚CDB/6˚CWB<br />

5m (16-3/8ft)<br />

7.5m (24-9/16ft)<br />

0m (0ft)<br />

0m (0ft)<br />

2.9<br />

-<br />

Unit converter<br />

kcal= kW ✕ 860<br />

Btu/h= kW ✕ 3,412<br />

cfm= m 3 /min ✕ 35.31<br />

lb= kg/0.4536<br />

* The specification data is subject to rounding variation.<br />

9


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

New<br />

Model name<br />

Power source<br />

Cooling capacity<br />

(Nominal)<br />

Power input<br />

Current input<br />

COP<br />

Temp. range of Indoor<br />

cooling Outdoor<br />

Heating capacity<br />

(Nominal )<br />

S SERIES<br />

R410A<br />

Power input<br />

Current input<br />

COP<br />

Temp. range of Indoor temp.<br />

Heating Outdoor temp.<br />

Indoor unit Total capacity<br />

connectable Model / Quantity<br />

Noise level (measured in anechoic room)<br />

Diameter of Liquid<br />

refrigerant pipe Gas<br />

<strong>External</strong> finish<br />

<strong>External</strong> dimension H ✕ W ✕ D<br />

Net weight<br />

Heat exchanger<br />

Compressor Type<br />

Maker<br />

Starting method<br />

Motor output<br />

Case heater<br />

Standard<br />

attachment<br />

Optional parts<br />

Remark<br />

*1<br />

*1<br />

*1<br />

*2<br />

*3<br />

*3<br />

*3<br />

kW<br />

kcal / h<br />

Btu / h<br />

kcal / h<br />

kW<br />

A<br />

W.B.<br />

D.B.<br />

kW<br />

kcal / h<br />

Btu / h<br />

kW<br />

A<br />

D.B.<br />

W.B.<br />

dB <br />

mm(in.)<br />

mm(in.)<br />

mm<br />

kg<br />

kW<br />

kW<br />

Lubricant ✕ original charge<br />

FAN<br />

Air flow rate m 3 / min<br />

<strong>External</strong> static press.<br />

Type ✕ Quantity<br />

Control, Driving mechanism<br />

Motor output kW<br />

HIC circuit (HIC: Heat Inter-Changer)<br />

Protection High pressure protection<br />

Inverter circuit (COMP. / FAN)<br />

Compressor<br />

Fan motor<br />

Defrosting method<br />

Refrigerant Type x original charge<br />

Control<br />

Document<br />

Accessory<br />

Note:<br />

*1 Nominal cooling conditions<br />

Indoor: 27˚CDB/19˚CWB<br />

Outdoor 35˚CDB<br />

Pipe length: 10m<br />

Level difference: 0m (0ft)<br />

* Nominal condition *1, *3 are subject to JIS B8615-1<br />

* Due to continuing improvement, above specifications may be subject to change without notice.<br />

<strong>Specifications</strong><br />

PUMY-P100VHM<br />

PUMY-P125VHM<br />

PUMY-P140VHM<br />

11.2<br />

9,600<br />

38,200<br />

10,000<br />

3.34<br />

1-phase, 220-230-240V, 50Hz 220V,60Hz<br />

14.0<br />

12,000<br />

47,800<br />

12,500<br />

4.32<br />

15.5<br />

13,300<br />

52,900<br />

14,000<br />

5.35<br />

15.4/14.8/14.1 15.4<br />

20.0/19.1/18.3 20.0<br />

24.7/23.6/22.7 24.7<br />

3.35<br />

12.5<br />

10,800<br />

42,700<br />

3.66<br />

16.9/16.2/15.5 16.9<br />

3.24<br />

15 ~ 24˚C (59~75˚F)<br />

- 5 ~ 46˚C (23~115˚F)<br />

10 to 46˚C D.B.(50 to 115˚FD.B.) : in case of connecting PKFY-P20/P25 type indoor unit.<br />

16.0<br />

13,800<br />

54,600<br />

4.33<br />

20.0/19.1/18.3 20.0<br />

2.90<br />

18.0<br />

15,500<br />

61,400<br />

5.58<br />

25.8/24.7/23.6 25.8<br />

3.42<br />

P20 ~ P125 / 1 ~ 6<br />

49/51<br />

2.2<br />

-<br />

3.69<br />

15~27˚C (59~81˚F)<br />

-12~15˚C (10~59˚F)<br />

50 ~ 130% of outdoor unit capacity<br />

P20 ~ P140 / 1 ~ 8<br />

50/52<br />

φ9.52 (φ3/8" ) Liquid<br />

φ15.88 (φ5/38" ) Gas<br />

Galvanized steel sheet<br />

<br />

1,350 ✕ 950 ✕ 330<br />

127<br />

Salt-resistant cross fin & copper tube<br />

Inverter scroll hermetic compressor<br />

Mitsubishi Electric Corporation<br />

Inverter<br />

2.9<br />

-<br />

MEL56 x 2.3 L<br />

100<br />

0 Pa<br />

Propeller fan ✕ 2<br />

DC-control, Direct-driven by motor<br />

0.06 x 2<br />

-<br />

High pressure sensor, High pressure switch 4.15 MPa<br />

Over-heat protection, Over-current protection<br />

Discharge thermo protection, Over-current protection<br />

Over-heat protection, Voltage protection<br />

Auto-defrost mode (Reversed refrigerant circle)<br />

R410A ✕ 8.5kg ( 19 lb)<br />

LEV circuit<br />

Installation Manual<br />

Grounded lead wire ✕ 2<br />

Joint: CMY-Y62G-F ; Header:CMY-Y64/68G-F<br />

3.23<br />

51/53<br />

3.3<br />

-<br />

Only one indoor unit of Fresh Air type is connected with one outdoor unit.<br />

Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual.<br />

*2 Nominal cooling conditions *3 Nominal heating conditions<br />

27˚CDB/19.5˚CWB<br />

20˚CDB<br />

35˚CDB<br />

7˚CDB/6˚CWB<br />

5m<br />

10m<br />

0m (0ft)<br />

0m (0ft)<br />

Unit converter<br />

kcal= kW ✕ 860<br />

Btu/h= kW ✕ 3,412<br />

cfm= m 3 /min ✕ 35.31<br />

lb= kg/0.4536<br />

* The specification data is subject to rounding variation.<br />

10


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

New<br />

S SERIES<br />

R410A<br />

PUMY-P100,125,140YHM / PUMY-P100,125,140VHM<br />

<strong>External</strong> <strong>Dimensions</strong><br />

Unit : mm<br />

1 FREE SPACE (Around the unit) 2 SERVICE SPACE<br />

The diagram below shows a<br />

<strong>Dimensions</strong> of space needed<br />

basic example.<br />

for service access are<br />

Explantion of particular details are<br />

shown in the below diagram.<br />

given in the installation manuals etc.<br />

Over 10mm Over 10mm<br />

FREE<br />

Over 150mm<br />

Over 150mm<br />

Over<br />

10<br />

Service space Over<br />

500<br />

Over Over<br />

500 150<br />

Less than<br />

30<br />

3 FOUNDATION BOLTS<br />

Please secure the unit firmly<br />

with 4 foundation (M10) bolts.<br />

(Bolts and washers must be<br />

purchased locally.)<br />

<br />

FOUNDATION<br />

4 PIPING-WIRING DIRECTIONS<br />

Piping and wiring connections<br />

can be made from 4 directions:<br />

FRONT,Right,Rear and Below.<br />

Side Air Intake<br />

30 330<br />

Rear Air Intake<br />

2-U Shaped notched holes<br />

(Foundation Bolt M10)<br />

175 600<br />

175<br />

Installation Feet<br />

2-12 X 36 Oval holes<br />

(Foundation Bolt M10)<br />

Air Discharge<br />

70<br />

56<br />

37<br />

53 56<br />

28 370<br />

417<br />

42<br />

19<br />

Rear Air Intake<br />

Side Air Intake<br />

Handle for moving<br />

322<br />

950<br />

Ground for the power supply<br />

Terminal connection<br />

Left····· For the power supply<br />

Center·····For the transmission line<br />

( Right····· For concentration control )<br />

Ground for the transmission line<br />

Ground for concentration control<br />

Service panel<br />

Example of Notes<br />

Handle for moving<br />

Handle for moving<br />

Handle for moving<br />

1350<br />

635<br />

Handle for moving<br />

1 • • • Refrigerant GAS pipe connction ø15.88 (5/8")Flare<br />

2 • • • Refrigerant LIQUID pipe connection ø 9.52 (3/8")Flare<br />

✻1 • • • Indication of STOP VALVE connection location.<br />

920<br />

Air intake<br />

371<br />

1<br />

✻ 1423<br />

✻1507<br />

2<br />

Piping Knock-Out Hole Details<br />

23<br />

71<br />

Front piping cover<br />

Rear piping cover<br />

Power supply wiring hole<br />

(2-ø27Knock-Out)<br />

Front trunking hole<br />

40 45<br />

(Knock-Out)<br />

ø92<br />

Front piping hole<br />

(Knock-Out) 92<br />

65<br />

27 55<br />

23 73 63<br />

Power supply wiring hole<br />

Right piping hole (2-ø27Knock-Out)<br />

(Knock-Out)<br />

Right trunking hole<br />

(Knock-Out)<br />

75 40<br />

45<br />

19 55<br />

92<br />

65<br />

23 27 92<br />

73 63<br />

ø92<br />

23 73 63<br />

27<br />

55<br />

40<br />

ø92<br />

92<br />

Power supply wiring hole<br />

(2-ø27Knock-Out)<br />

Rear trunking hole<br />

(Knock-Out)<br />

Rear piping hole<br />

(Knock-Out)<br />

81 219<br />

30 220 145 145 145<br />

Drain hole<br />

5-ø33<br />

71<br />

Bottom piping hole<br />

(Knock-Out)<br />

11


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

Model name<br />

Capacity<br />

Power source<br />

Power input<br />

Current<br />

COP<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

Airflow rate<br />

Compressor Fan Protection<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Refrigerant piping diameter Gas side<br />

mm(in.) Liquid side<br />

Refrigerant type<br />

Noise level (dB) (A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

Indoor unit<br />

<strong>External</strong> dimension<br />

Temp. range of<br />

cooling<br />

Temp. range of<br />

heating<br />

Model name<br />

Capacity<br />

Power source<br />

Power input<br />

Current<br />

COP<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

Airflow rate<br />

Compressor Fan Protection<br />

mm(in.)<br />

Indoor<br />

Outdoor<br />

Indoor<br />

Outdoor<br />

kW (*1)<br />

kcal/h (*2)<br />

BTU/h (*1)<br />

kW<br />

A<br />

m 3 /min<br />

L/s<br />

cfm<br />

kg(lbs)<br />

Total capacity<br />

Model/Quantity<br />

Height (H)<br />

Width (W)<br />

Depth (D)<br />

W.B.<br />

D.B.<br />

D.B<br />

W.B.<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Refrigerant piping diameter Gas side<br />

mm(in.) Liquid side<br />

Refrigerant type<br />

Noise level (dB) (A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

Indoor unit<br />

<strong>External</strong> dimension<br />

Temp. range of<br />

cooling<br />

Temp. range of<br />

Y SERIES<br />

R410A<br />

mm(in.)<br />

Indoor<br />

Outdoor<br />

Indoor<br />

Outdoor<br />

kW (*1)<br />

kcal/h (*2)<br />

BTU/h (*1)<br />

kW<br />

A<br />

m 3 /min<br />

L/s<br />

cfm<br />

kg(lbs)<br />

Total capacity<br />

Model/Quantity<br />

Height (H)<br />

Width (W)<br />

Depth (D)<br />

W.B.<br />

D.B.<br />

D.B<br />

W.B.<br />

PUY-P200YGM-A<br />

Cooling<br />

22.4<br />

20,000<br />

76,400<br />

6.14<br />

10.3/9.8/9.4<br />

3.65<br />

<strong>Specifications</strong><br />

PUHY-P200YGM-A PUHY-P250YGM-A PUHY-P300YGM-A PUHY-P350YGM-A PUHY-P400YGM-A<br />

PUY-P250YGM-A PUY-P300YGM-A PUY-P350YGM-A<br />

Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating<br />

25.0<br />

28.0<br />

31.5<br />

33.5<br />

37.5<br />

40.0<br />

45.0<br />

45.0<br />

50.0<br />

–<br />

25,000<br />

–<br />

30,000<br />

–<br />

35,000<br />

–<br />

40,000<br />

–<br />

85,300 95,500 107,500<br />

136,500 153,500 153,500 170,600<br />

Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition.<br />

*1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

Pipe length: 7.5m(24-9/16Ft) Height difference: 0m<br />

PUHY-P200,250,300,350YGM-A<br />

PUY-P200,250,300,350YGM-A<br />

4.7<br />

5.98<br />

10.0/9.5/9.2<br />

4.18<br />

φ19.05(φ3/4") Brazed<br />

φ9.52(φ3/8") Flare<br />

56<br />

218(481)<br />

Models P20~P250/1~13<br />

Cooling<br />

50.0<br />

45,000<br />

170,600<br />

<strong>External</strong> <strong>Dimensions</strong><br />

114,300 128,000<br />

3N ~ 380/400/415V 50/60Hz<br />

7.72<br />

7.62<br />

9.57<br />

9.1<br />

11.39 11.02 13.42 12.43<br />

13.0/12.3/11.9 12.8/12.2/11.7 16.1/15.3/14.7 15.3/14.5/14.0 19.2/18.2/17.6 18.6/17.6/17.0 22.6/21.5/20.7 20.9/19.9/19.2<br />

3.63<br />

4.13<br />

3.50<br />

4.12<br />

3.51<br />

4.08<br />

3.35<br />

4.02<br />

Salt Ptotected Fin<br />

Inverter scroll hermetic compressor<br />

Inverter<br />

6.7<br />

8.0<br />

9.6<br />

9.7<br />

Propeller fan ✕ 1<br />

200<br />

3,333<br />

7,063<br />

0.38<br />

240<br />

4,000<br />

8,476<br />

0.64<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

φ22.2(φ7/8") Brazed<br />

φ28.58(φ1-1/8") Brazed<br />

φ9.52(φ3/8") Flare (φ12.7(φ1/2") for over 90m) φ9.52(φ3/8") Flare (φ12.7(φ1/2") for over 40m)<br />

R410A<br />

φ12.7(φ1/2") Flare<br />

φ12.7(φ1/2") Flare<br />

57<br />

59<br />

60<br />

61<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

233(514)<br />

233(514)<br />

50~130% of outdoor unit capacity<br />

233(514)<br />

275(607)<br />

Models P20~P250/1~16 Models P20~P250/1~19<br />

1840(72-1/2")<br />

Models P20~P250/1~20 Models P20~P250/1~22<br />

990(39")<br />

1290(50-13/16")<br />

840(33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

PUHY-P450YGM-A PUHY-P500YGM-A PUHY-P550YGM-A PUHY-P600YGM-A PUHY-P650YGM-A<br />

Heating Cooling Heating Cooling Heating Cooling Heating Cooling<br />

56.0<br />

56.0<br />

63.0<br />

63.0<br />

67.0<br />

67.4<br />

75.0<br />

73.0<br />

–<br />

50,000<br />

–<br />

55,000<br />

–<br />

60,000<br />

–<br />

65,000<br />

191,100 191,100 215,000<br />

230,000 255,900 249,100<br />

215,000 228,600<br />

3N ~ 380/400/415V 50/60Hz<br />

13.61 13.86 15.59 15.89 17.08 16.37 17.59 17.73<br />

22.9/21.8/21.0 23.3/22.2/21.4 26.3/25.0/24.0 26.8/25.4/24.5 28.8/27.3/26.4 27.6/26.2/25.3 29.6/28.2/27.1 29.9/28.4/27.4<br />

3.67<br />

4.04<br />

3.59<br />

3.96<br />

3.69<br />

4.09<br />

3.83<br />

4.23<br />

Salt Protected Fin<br />

Inverter scroll hermetic compressor + Scroll hermetic<br />

Inverter + Direct<br />

6.8 + 5.3<br />

8.2 + 5.3<br />

9.3 + 5.3<br />

Propeller fan ✕ 2<br />

10.1 + 5.3<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

φ28.58(φ1-1/8") Brazed<br />

φ15.88(φ5/8") Flare<br />

R410A<br />

60/61 (50Hz/60Hz) 61/62 (50Hz/60Hz)<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

455(1004)<br />

455(1004)<br />

455(1004)<br />

50~130% of outdoor unit capacity<br />

455(1004)<br />

Models P20~P250/1~24 Models P20~P250/1~24 Models P20~P250/1~24 Models P20~P250/1~32<br />

1840(72-1/2")<br />

1990(78-3/8")<br />

840(33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

Conn. pipe(Gas)<br />

200: ø19.05 <br />

250: ø22.2 <br />

300: ø22.2 <br />

350: ø28.58 <br />

A<br />

80<br />

494<br />

166<br />

Y<br />

Y<br />

ø27 Knockout hole<br />

<br />

20<br />

553<br />

*2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Pipe length: 5m(16-3/8Ft)<br />

Height difference: 0m<br />

16<br />

840<br />

845(mounting pitch)<br />

877<br />

19.65<br />

33.1/31.5/30.3<br />

3.72<br />

10.9 + 5.3<br />

Heating<br />

81.5<br />

–<br />

278,100<br />

19.82<br />

33.4/31.7/30.6<br />

4.11<br />

62/62.5 (50Hz/60Hz)<br />

455(1004)<br />

Models P20~P250/1~32<br />

*3 It is measured in anechoic room.<br />

Unit : mm<br />

57<br />

Conn. pipe(Liquid)<br />

200: ø9.52 <br />

250: ø9.52 <br />

300: ø9.52 <br />

350: ø12.7 <br />

70<br />

65 160<br />

ø62 Knockout hole<br />

2X2-14X20 0val hole<br />

768<br />

80<br />

<br />

(Mounting hole)<br />

Knockout hole<br />

Changeable to ø27,ø33 by using<br />

attached conduit mounting plate <br />

Air outlet<br />

Cross section X – X<br />

45<br />

900(mounting pitch)<br />

990<br />

Top view<br />

45<br />

265<br />

16<br />

Model<br />

200<br />

250<br />

300<br />

350<br />

A<br />

132<br />

136<br />

136<br />

146<br />

ø53<br />

<br />

• Refrigerant (Gas) conn. pipe......1 pc.<br />

(P200type:Packaged in the accessory kit)<br />

(P250,P300,P350type:Already installed on the unit)<br />

• Packing for conn. pipe................1 pc.<br />

(P200type:Not attached)<br />

(P250,P300,P350type:Attached near the ball valve)<br />

• Conduit mouting plate<br />

ø33, ø27..............................1 pc.Each<br />

• Tapping screw M4......................2 pcs.<br />

Note1.Use the opening at the bottom of the unit<br />

when running the power supply line from<br />

the front or from the side of the unit.<br />

Note2.Please refer to (2/2) for information<br />

regarding necessary spacing around the<br />

unit and foundation work.<br />

12 5<br />

Cross section Y – Y<br />

Air<br />

inlet<br />

90<br />

10<br />

37 117 117 37<br />

Left side view<br />

Air<br />

inlet<br />

ø27 Knockout hole<br />

135 <br />

80 40<br />

134 100<br />

280<br />

Knockout hole<br />

<br />

Knockout hole<br />

Service panel<br />

Refrig. service<br />

valve (Liquid)<br />

<br />

X<br />

44<br />

235<br />

150<br />

67 160<br />

100 83<br />

Knockout hole<br />

<br />

207 67<br />

valve(Gas)<br />

<br />

Front view<br />

X<br />

78<br />

11<br />

1575<br />

1840<br />

12


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

Y SERIES<br />

R410A<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PUHY-P400YGM-A<br />

644<br />

Unit : mm<br />

503<br />

145<br />

57 80<br />

166<br />

65 160<br />

1068<br />

80 ø62 Knockout hole<br />

<br />

Changeable to ø46,ø53 by using<br />

Conn. pipe(Gas)<br />

Cross section X – X attached conduit mounting plate <br />

ø28.58<br />

Conn. pipe(Liquid)<br />

Air outlet<br />

ø12.7<br />

265<br />

16<br />

Knockout hole<br />

<br />

Y<br />

Y<br />

ø27 Knockout hole<br />

<br />

840<br />

845(mounting pitch)<br />

877<br />

20<br />

70<br />

2X2-14X20 Oval hole<br />

(Mounting hole)<br />

45<br />

1200(mounting pitch)<br />

1290<br />

Top view<br />

45<br />

ø53<br />

16<br />

12 5<br />

Air<br />

inlet<br />

Cross section Y – Y<br />

<br />

• Refrigerant (Gas) conn. pipe......1 pc.<br />

(Already installed on the unit)<br />

• Packing for conn. pipe................1 pc.<br />

(Attached near the ball valve)<br />

• Conduit mouting plate<br />

ø53, ø46.............................1 pc.Each<br />

• Tapping screw M4.....................2 pcs.<br />

Note1.Use the opening at the bottom of the unit<br />

when running the power supply line from<br />

the front or from the side of the unit.<br />

Note2.Please refer to (2/2) for information<br />

regarding necessary spacing around the<br />

unit and foundation work.<br />

Air<br />

inlet<br />

10 89<br />

37<br />

115<br />

Left side view<br />

ø27 Knockout hole<br />

<br />

80 40<br />

100<br />

134<br />

280<br />

Knockout hole<br />

Service panel<br />

Refrig. service<br />

valve (Liquid)<br />

X<br />

44<br />

235<br />

150<br />

Knockout hole<br />

115 37 Refrig. service<br />

valve(Gas)<br />

<br />

100<br />

67 160<br />

83<br />

68 355<br />

Knockout hole<br />

<br />

Front view<br />

355 68<br />

X<br />

78<br />

11<br />

1575<br />

1840<br />

PUHY-P450,500,550,600,650YGM-A<br />

Knockout hole<br />

<br />

145<br />

80<br />

57<br />

Conn. pipe(Gas)<br />

ø28.58<br />

65 160<br />

494<br />

162<br />

768<br />

Conn. pipe(Liquid)<br />

ø15.88<br />

Y<br />

Y<br />

1000<br />

ø27 Knockout hole<br />

<br />

20<br />

70<br />

Y<br />

Y<br />

ø62 Knockout hole<br />

<br />

3X2-14X20 Oval hole<br />

80<br />

Changeable to ø46,ø53 by using<br />

(Mounting hole)<br />

attached conduit mounting plate <br />

Cross section X – X<br />

553<br />

45<br />

950(mounting pitch)<br />

1990<br />

Top view<br />

950(mounting pitch)<br />

840<br />

45<br />

16 845(mounting pitch) 16<br />

877<br />

Air outlet<br />

ø53<br />

265<br />

13<br />

12<br />

5<br />

Cross section Y – Y<br />

<br />

• Refrigerant (Gas) conn. pipe....1 pc.<br />

(Already installed on the unit)<br />

• Packing for conn. pipe......1 pc.<br />

(Attached near the ball valve)<br />

• Conduit mouting plate<br />

ø53, ø46......1 pc.Each<br />

• Tapping screw M4...2 pcs.<br />

Note1.Use the opening at the bottom of the unit<br />

when running the power supply line from<br />

the front or from the side of the unit.<br />

Note2.Please refer to (2/2) for information<br />

regarding necessary spacing around the<br />

unit and foundation work.<br />

Air<br />

inlet<br />

89<br />

10<br />

Air<br />

inlet<br />

ø27 Knockout hole<br />

<br />

80 40<br />

Knockout hole<br />

37 115 115 37 <br />

Left side view<br />

134 100<br />

280<br />

Knockout hole<br />

Service panel<br />

Refrig. service<br />

valve (Liquid)<br />

<br />

44<br />

235<br />

150<br />

X<br />

Refrig. service<br />

valve(Gas)<br />

<br />

67 160<br />

100 83<br />

Knockout hole<br />

68 205 <br />

205<br />

Front view<br />

68<br />

11 78<br />

1575<br />

X<br />

1840


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

Y SERIES<br />

R410A<br />

Model name<br />

Capacity<br />

kW (*1)<br />

kcal/h (*2)<br />

BTU/h (*1)<br />

Power source<br />

Power input<br />

kW<br />

Current<br />

A<br />

COP<br />

Composing unit model name<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

m 3 /min<br />

Airflow rate L/s<br />

cfm<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Gas side (main)(mm(in.))<br />

Gas side (between Comp unit and HEX unit)(mm(in.)<br />

Liquid side (main)(mm(in.))<br />

Liquid side (between Comp unit and HEX unit)(mm(in.))<br />

Refrigerant type<br />

Noise level (dB)<br />

Set<br />

(A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

kg(lbs)<br />

Total capacity<br />

Indoor unit<br />

Model/Quantity<br />

Height (H)<br />

<strong>External</strong> dimension<br />

Width (W)<br />

(mm(in.))<br />

Depth (D)<br />

Indoor W.B.<br />

Temp. range of cooling<br />

Outdoor D.B.<br />

Indoor D.B<br />

Temp. range of heating<br />

Outdoor W.B.<br />

Compressor Fan Protection<br />

Refrigerant<br />

piping diameter<br />

<strong>Specifications</strong><br />

PUHY-P700YSGM-A<br />

PUHY-P750YSGM-A<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

78.4<br />

70,000<br />

267,500<br />

21.7<br />

36.6/34.8/33.5<br />

3.61<br />

88.0<br />

–<br />

300,300<br />

3N ~ 380/400/415V 50/60Hz<br />

21.83<br />

84.0<br />

75,000<br />

286,600<br />

24.9<br />

36.8/35.0/33.7<br />

42.0/39.9/38.4<br />

4.03<br />

3.37<br />

94.5<br />

–<br />

322,400<br />

25.37<br />

42.8/40.6/39.2<br />

3.72<br />

PUHY-P700YGM-A (Compressor unit) PUHN-P01YGM-A (Heat exchanger unit) PUHY-P750YGM-A (Compressor unit) PUHN-P01YGM-A (Heat exchanger unit)<br />

Salt Protected Fin<br />

Inverter scroll hermetic compressor ✕ 2<br />

–<br />

Inverter<br />

–<br />

8.6 + 8.6<br />

–<br />

Propeller fan ✕ 1<br />

Propeller fan ✕ 1<br />

240<br />

240<br />

4,000<br />

4,000<br />

8,476<br />

8,476<br />

0.64<br />

0.64<br />

High pressure switch 4.15MPa (601 psi)<br />

–<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

R410A<br />

62<br />

–<br />

Thermal switch<br />

Inverter scroll hermetic compressor ✕ 2<br />

–<br />

Inverter<br />

–<br />

9.4 + 9.4<br />

–<br />

Propeller fan ✕ 1<br />

Propeller fan ✕ 1<br />

240<br />

240<br />

4,000<br />

4,000<br />

8,476<br />

8,476<br />

0.64<br />

0.64<br />

High pressure switch 4.15MPa (601 psi)<br />

–<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

–<br />

Over-heat protection/Thermal switch<br />

Thermal switch<br />

φ34.93(φ1-3/8") Brazed<br />

φ28.58(φ1-1/8") Flange / φ28.58(φ1-1/8") Brazed<br />

φ19.05(φ3/4") Brazed + Flare<br />

φ12.7(φ1/2") Flare / φ12.7(φ1/2") Brazed<br />

–<br />

R410A<br />

–<br />

63<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

430(948)<br />

155(342)<br />

430(948)<br />

155(342)<br />

50~130% of outdoor unit capacity<br />

Models P20~P250/1~34<br />

Models P20~P250/1~34<br />

1840(72-1/2")<br />

1690(66-9/16")<br />

990(39")<br />

1690(66-9/16")<br />

990(39")<br />

840(33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

Model name<br />

Capacity<br />

Compressor Fan Protection<br />

Refrigerant<br />

piping diameter<br />

kW (*1)<br />

kcal/h (*2)<br />

PUHY-P800YSGM-A<br />

Cooling<br />

Heating<br />

90.0<br />

100.0<br />

80,000<br />

–<br />

307,100<br />

341,200<br />

3N ~ 380/400/415V 50/60Hz<br />

26.75<br />

26.9<br />

45.1/42.9/41.3<br />

45.4/43.1/41.5<br />

3.36<br />

3.72<br />

PUHY-P800YGM-A (Compressor unit)<br />

PUHN-P01YGM-A (Heat exchanger unit)<br />

Salt Protected Fin<br />

Inverter scroll hermetic compressor ✕ 2<br />

–<br />

Inverter<br />

–<br />

10.1 + 10.1<br />

–<br />

Propeller fan ✕ 1<br />

Propeller fan ✕ 1<br />

240<br />

240<br />

4,000<br />

4,000<br />

8,476<br />

8,476<br />

0.64<br />

0.64<br />

High pressure switch 4.15MPa (601 psi)<br />

–<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

–<br />

Over-heat protection/Thermal switch<br />

Thermal switch<br />

φ34.93(φ1-3/8") Brazed<br />

φ28.58(φ1-1/8") Flange / φ28.58(φ1-1/8") Brazed<br />

φ19.05(φ3/4") Brazed + Flare<br />

φ12.7(φ1/2") Flare / φ12.7(φ1/2") Brazed<br />

R410A<br />

–<br />

64<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

430(948)<br />

155(342)<br />

50~130% of outdoor unit capacity<br />

Models P20~P250/1~34<br />

1840(72-1/2")<br />

1690(66-9/16")<br />

990(39")<br />

840(33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

BTU/h (*1)<br />

Power source<br />

Power input<br />

kW<br />

Current<br />

A<br />

COP<br />

Composing unit model name<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

m 3 /min<br />

Airflow rate L/s<br />

cfm<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Gas side (main)(mm(in.))<br />

Gas side (between Comp unit and HEX unit)(mm(in.)<br />

Liquid side (main)(mm(in.))<br />

Liquid side (between Comp unit and HEX unit)(mm(in.))<br />

Refrigerant type<br />

Noise level (dB)<br />

Set<br />

(A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

kg(lbs)<br />

Total capacity<br />

Indoor unit<br />

Model/Quantity<br />

Height (H)<br />

<strong>External</strong> dimension<br />

Width (W)<br />

(mm(in.))<br />

Depth (D)<br />

Indoor W.B.<br />

Temp. range of cooling<br />

Outdoor D.B.<br />

Indoor D.B<br />

Temp. range of heating<br />

Outdoor W.B.<br />

Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition.<br />

*1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

Pipe length: 7.5m(24-9/16Ft) Height difference: 0m<br />

*2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Pipe length: 5m(16-3/8Ft)<br />

Height difference: 0m<br />

*3 It is measured in anechoic room.<br />

14


3<br />

OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

Y SERIES<br />

R410A<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PUHY-P700,750,800YGM-A<br />

Knockout hole<br />

<br />

Refrig.service valve<br />

(Liquid pipe to HEX unit)<br />

ø12.7<br />

Refrig.service valve<br />

(Gas pipe to HEX unit)<br />

ø28.58<br />

161<br />

107<br />

Refrig.service valve<br />

(Gas pipe to indoor unit)<br />

Refrig.service valve<br />

(Liquid pipe to indoor unit)<br />

124<br />

159<br />

ø75 Knockout hole<br />

<br />

Changeable to ø62 by using<br />

attached conduit mounting plate<br />

<br />

ø27 Knockout hole<br />

<br />

Cross section X – X<br />

Air outlet<br />

3 X 2 – 14 X 20 Oval hole<br />

(Mounting hole)<br />

45<br />

800(mounting pitch)<br />

800(mounting pitch)<br />

1690<br />

Top view<br />

840<br />

45<br />

16 845(mounting pitch) 16<br />

877<br />

Unit : mm<br />

<br />

• Refrigerant conn. pipe with flange (to indoor unit:Gas)....1 pc.<br />

(Already installed on the unit)<br />

• Refrigerant conn. pipe with flange (to HEX unit:Gas).......1 pc.<br />

(Already installed on the unit)<br />

• Packing for conn. pipe with flange (to indoor unit:Gas)....1 pc.<br />

(Attached near ball valve)<br />

• Packing for conn. pipe with flange (to HEX unit:Gas)......1 pc.<br />

(Attached near ball valve)<br />

• Conduit mouting plate<br />

ø62...........................1 pc.<br />

• Tapping screw µ4.....2 pcs.<br />

Air<br />

inlet<br />

Air<br />

inlet<br />

Service panel<br />

Knockout hole<br />

265<br />

1840<br />

Note1.Use the opening at the bottom of the unit<br />

when running the power supply line from<br />

the front or from the side of the unit.<br />

Note2.Please refer to (2/2) for information<br />

regarding necessary space around the<br />

unit and foundation work.<br />

10 89<br />

135<br />

80<br />

40<br />

100<br />

134<br />

37 175<br />

175 37<br />

ø27 Knockout hole<br />

<br />

280<br />

Knockout hole<br />

<br />

Service panel<br />

12<br />

11<br />

241<br />

Knockout hole<br />

<br />

X<br />

117<br />

83<br />

254<br />

88<br />

Conn. pipe(Gas)<br />

ø34.93<br />

Conn. pipe(Liquid)<br />

ø19.05<br />

11 78<br />

1575<br />

X<br />

PUHN-P01YGM-A<br />

ø27hole+rubber bush<br />

<br />

(Bottom of controlbox)<br />

82<br />

120<br />

60 ø27hole+rubber bush<br />

<br />

(Bottom of controlbox)<br />

Cross section x-x<br />

Air outlet<br />

Left side view<br />

2x2-14x20 Oval hole<br />

45 900(mounting pitch) 45<br />

(Mounting hole)<br />

990<br />

Top view<br />

840<br />

16 845(mounting pitch) 16<br />

877<br />

Front view<br />

Note1.Use the opening at the bottom of the unit<br />

when running the power supply line from<br />

the front or from the side of the unit.<br />

Note2.Please refer to (2/2) for information<br />

regarding necessary space around the<br />

unit and foundation work.<br />

Air outlet<br />

265<br />

Air<br />

inlet<br />

Air<br />

inlet<br />

1575<br />

1840<br />

Air<br />

inlet<br />

Air<br />

inlet<br />

Refrig. service valve x<br />

(Gas pipe to compressor unit)<br />

ø28.58<br />

70<br />

45<br />

x<br />

50<br />

Knockout hole<br />

<br />

40<br />

80<br />

PUHY-P700,750,800YSGM-A<br />

10 90<br />

37 117 Air 117 37<br />

inlet<br />

Left side view<br />

877<br />

Refrig. service valve<br />

(Liquid pipe to compressor unit)<br />

ø12.7<br />

67<br />

207<br />

80<br />

Knockout hole 207 67<br />

<br />

Front view<br />

11 78<br />

165<br />

250<br />

2690<br />

115<br />

134<br />

157<br />

Air<br />

inlet<br />

Right side view<br />

840<br />

Air outlet<br />

990 10<br />

1690<br />

HEX unit<br />

Compressor unit<br />

Air<br />

inlet<br />

Air<br />

inlet<br />

1575 265<br />

1840<br />

Gas pipe used to connect<br />

compressor unit and HEX unit<br />

Conn.pipe(Gas)<br />

ø34.93<br />

Conn.pipe(Liquid)<br />

ø19.05<br />

15<br />

Left side view<br />

Liquid pipe used to connect<br />

compressor unit and HEX unit<br />

Front view


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

Model name<br />

Capacity (*1)<br />

Current input A<br />

COP<br />

Power source<br />

Composing unit model name<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

m 3/min<br />

Airflow rate<br />

L/s<br />

cfm<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Compressor Fan Protection<br />

Refrigerant<br />

piping diameter<br />

Gas side (main)(mm(in.))<br />

Gas side (between unit and distributor)(mm(in.))<br />

Liquid side (main)(mm(in.))<br />

Liquid side (between unit and distributor)(mm(in.))<br />

Oil balance pipe(mm(in.))<br />

Refrigerant type<br />

Noise level (dB)<br />

(A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

Indoor unit<br />

Power input<br />

<strong>External</strong> dimension<br />

(mm(in.))<br />

Temp. range of cooling<br />

Temp. range of heating<br />

Model name<br />

Capacity (*1)<br />

Set<br />

kW<br />

Btu/h(*1)<br />

kcal/h(*2)<br />

kW<br />

kg (lbs.)<br />

Total capacity<br />

Model / Quantity<br />

Height (H)<br />

Width (W)<br />

Depth (D)<br />

Indoor W.B.<br />

Outdoor D.B.<br />

Indoor D.B.<br />

Outdoor W.B.<br />

Current input A<br />

COP<br />

Power source<br />

Composing unit model name<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

m 3/min<br />

Airflow rate<br />

L/s<br />

cfm<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Compressor Fan Protection<br />

Refrigerant<br />

piping diameter<br />

Gas side (main)(mm(in.))<br />

Gas side (between unit and distributor)(mm(in.))<br />

Liquid side (main)(mm(in.))<br />

Liquid side (between unit and distributor)(mm(in.))<br />

Oil balance pipe(mm(in.))<br />

Refrigerant type<br />

Noise level (dB)<br />

(A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

Indoor unit<br />

<strong>External</strong> dimension<br />

(mm(in.))<br />

Temp. range of cooling<br />

Temp. range of heating<br />

Note:<br />

Y SERIES<br />

Power input<br />

R410A<br />

Set<br />

kW<br />

Btu/h(*1)<br />

kcal/h(*2)<br />

kW<br />

kg (lbs.)<br />

Total capacity<br />

Model / Quantity<br />

Height (H)<br />

Width (W)<br />

Depth (D)<br />

Indoor W.B.<br />

Outdoor D.B.<br />

Indoor D.B.<br />

Outdoor W.B.<br />

Cooling<br />

96.0<br />

327,500<br />

85,000<br />

25.28<br />

42.6/40.5/39.0<br />

3.80<br />

PUHY-P850YSGM-A<br />

Heating<br />

108.0<br />

368,500<br />

–<br />

27.47<br />

46.3/44.0/42.4<br />

3.93<br />

<strong>Specifications</strong><br />

Cooling<br />

101.0<br />

344,600<br />

90,000<br />

26.71<br />

45.0/42.8/41.2<br />

3.78<br />

PUHY-P900YSGM-A<br />

Heating<br />

113.0<br />

385,500<br />

–<br />

29.10<br />

49.1/46.6/44.9<br />

3.88<br />

3-phase 4-wire 380/400/415V 50/60Hz<br />

PUHY-P450YMM-A PUHY-P400YSM-A PUHY-P500YMM-A PUHY-P400YSM-A<br />

Salt-resistant cross fin & copper tube<br />

Inverter scroll hermetic comp. + Scroll hermetic comp.<br />

Inverter + Direct<br />

9.4 + 5.3 / 8.5 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

8.5 + 5.3 / 8.5 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

10.3 + 5.3 / 9.6 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

φ41.28(φ1-5/8") Brazed<br />

φ28.58(φ1-1/8") Brazed<br />

φ19.05(φ3/4") Brazed<br />

φ15.88(φ5/8") Flare<br />

φ9.52(φ3/8") Flare<br />

R410A<br />

63/64 63/64<br />

8.5 + 5.3 / 8.5 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

Cooling<br />

108.0<br />

368,500<br />

95,000<br />

29.23<br />

49.3/46.8/45.1<br />

3.69<br />

PUHY-P550YMM-A<br />

11.2 + 5.3 / 10.9 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

PUHY-P950YSGM-A<br />

Heating<br />

119.5<br />

407,700<br />

–<br />

30.42<br />

51.3/48.7/47.0<br />

3.93<br />

PUHY-P400YSM-A<br />

8.5 + 5.3 / 8.5 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

458 (1010) 460 (1015) 458 (1010) 460 (1015) 458 (1010) 460 (1015)<br />

50~130% of outdoor unit capacity<br />

P20~P250 / 1~42<br />

1840 (72-1/2")<br />

1990 (78-3/8")<br />

840 (33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

Cooling<br />

113.0<br />

385,500<br />

100,000<br />

31.11<br />

52.5/49.8/48.0<br />

3.63<br />

PUHY-P1000YSGM-A<br />

Heating<br />

127.0<br />

433,300<br />

–<br />

32.68<br />

55.1/52.4/50.5<br />

3.89<br />

Cooling<br />

118.0<br />

402,600<br />

105,000<br />

33.48<br />

56.5/53.6/51.7<br />

3.52<br />

PUHY-P1050YSGM-A<br />

63/64<br />

Heating<br />

132.0<br />

450,300<br />

–<br />

34.24<br />

57.8/54.9/52.9<br />

3.86<br />

3-phase 4-wire 380/400/415V 50/60Hz<br />

PUHY-P600YMM-A PUHY-P400YSM-A PUHY-P650YMM-A PUHY-P400YSM-A<br />

Salt-resistant cross fin & copper tube<br />

Inverter scroll hermetic comp. + Scroll hermetic comp.<br />

Inverter + Direct<br />

11.6 + 5.3 / 11.6 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

8.5 + 5.3 / 8.5 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

φ41.28(φ1-5/8") Brazed<br />

φ28.58(φ1-1/8") Brazed<br />

φ19.05(φ3/4") Brazed<br />

φ15.88(φ5/8") Flare<br />

φ9.52(φ3/8") Flare<br />

R410A<br />

11.6 + 5.3 / 11.6 + 5.3<br />

8.5 + 5.3 / 8.5 + 5.3<br />

Propeller fan ✕ 2<br />

Propeller fan ✕ 2<br />

400<br />

400<br />

6,667<br />

6,667<br />

14,126<br />

14,126<br />

0.38 ✕ 2<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

63/64 63.5/64.5<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

458 (1010) 460 (1015) 458 (1010) 460 (1015)<br />

50~130% of outdoor unit capacity<br />

P20~P250 / 1~42<br />

1840 (72-1/2")<br />

1990 (78-3/8")<br />

840 (33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

1. Cooling/heating capacity indicates the maximum value at operation under the following condition.<br />

*1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

Pipe length: 7.5m(24-9/16Ft) Height difference: 0m<br />

*2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Pipe length: 5m(16-3/8Ft)<br />

Height difference: 0m<br />

*3 It is measured in anechoic room.<br />

16


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

Y SERIES<br />

R410A<br />

Model name<br />

Capacity (*1)<br />

Current input A<br />

COP<br />

Power source<br />

Composing unit model name<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

m 3/min<br />

Airflow rate<br />

L/s<br />

cfm<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Compressor Fan Protection<br />

Refrigerant<br />

piping diameter<br />

Gas side (main)(mm(in.))<br />

Gas side (between unit and distributor)(mm(in.))<br />

Liquid side (main)(mm(in.))<br />

Liquid side (between unit and distributor)(mm(in.))<br />

Oil balance pipe(mm(in.))<br />

Refrigerant type<br />

Noise level (dB)<br />

(A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

Indoor unit<br />

Power input<br />

<strong>External</strong> dimension<br />

(mm(in.))<br />

Temp. range of cooling<br />

Temp. range of heating<br />

Set<br />

kW<br />

Btu/h(*1)<br />

kcal/h(*2)<br />

kW<br />

kg (lbs.)<br />

Total capacity<br />

Model / Quantity<br />

Height (H)<br />

Width (W)<br />

Depth (D)<br />

Indoor W.B.<br />

Outdoor D.B.<br />

Indoor D.B.<br />

Outdoor W.B.<br />

Cooling<br />

124.0<br />

423,000<br />

110,000<br />

36.39<br />

61.4/58.3/56.2<br />

3.41<br />

PUHY-P1100YSGM-A<br />

<strong>Specifications</strong><br />

Heating<br />

140.0<br />

477,600<br />

–<br />

36.93<br />

62.3/59.2/57.0<br />

3.79<br />

Cooling<br />

130.0<br />

443,500<br />

115,000<br />

39.96<br />

67.4/64.0/61.7<br />

3.25<br />

PUHY-P1150YSGM-A<br />

Heating<br />

145.0<br />

494,700<br />

–<br />

38.46<br />

64.9/61.6/59.4<br />

3.77<br />

3-phase 4-wire 380/400/415V 50/60Hz<br />

PUHY-P450YMM-A PUHY-P650YSM-A PUHY-P500YMM-A PUHY-P650YSM-A<br />

Salt-resistant cross fin & copper tube<br />

Inverter scroll hermetic comp. + Scroll hermetic comp.<br />

Inverter + Direct<br />

9.4 + 5.3 / 8.5 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

11.6 + 5.3 / 11.6 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

φ41.28(φ1-5/8") Brazed<br />

φ28.58(φ1-1/8") Brazed<br />

φ19.05(φ3/4") Brazed<br />

φ15.88(φ5/8") Flare<br />

φ9.52(φ3/8") Flare<br />

R410A<br />

10.3 + 5.3 / 9.6 + 5.3<br />

11.6 + 5.3 / 11.6 + 5.3<br />

Propeller fan ✕ 2<br />

Propeller fan ✕ 2<br />

400<br />

400<br />

6,667<br />

6,667<br />

14,126<br />

14,126<br />

0.38 ✕ 2<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

64/65 64/65<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

458 (1010) 460 (1015) 458 (1010) 460 (1015)<br />

50~130% of outdoor unit capacity<br />

P20~P250 / 1~42<br />

1840 (72-1/2")<br />

1990 (78-3/8")<br />

840 (33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

Model name<br />

Capacity (*1)<br />

Current input A<br />

COP<br />

Power source<br />

Composing unit model name<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

m 3/min<br />

Airflow rate<br />

L/s<br />

cfm<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Compressor Fan Protection<br />

Refrigerant<br />

piping diameter<br />

Gas side (main)(mm(in.))<br />

Gas side (between unit and distributor)(mm(in.))<br />

Liquid side (main)(mm(in.))<br />

Liquid side (between unit and distributor)(mm(in.))<br />

Oil balance pipe(mm(in.))<br />

Refrigerant type<br />

Noise level (dB)<br />

(A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

Indoor unit<br />

Power input<br />

<strong>External</strong> dimension<br />

(mm(in.))<br />

Temp. range of cooling<br />

Temp. range of heating<br />

Note:<br />

Set<br />

kW<br />

Btu/h(*1)<br />

kcal/h(*2)<br />

kW<br />

kg (lbs.)<br />

Total capacity<br />

Model / Quantity<br />

Height (H)<br />

Width (W)<br />

Depth (D)<br />

Indoor W.B.<br />

Outdoor D.B.<br />

Indoor D.B.<br />

Outdoor W.B.<br />

Cooling<br />

136.0<br />

464,000<br />

120,000<br />

44.40<br />

74.9/71.2/68.6<br />

3.06<br />

PUHY-P1200YSGM-A<br />

Heating<br />

150.0<br />

511,700<br />

–<br />

39.73<br />

67.0/63.7/61.4<br />

3.78<br />

Cooling<br />

140.0<br />

477,600<br />

125,000<br />

47.56<br />

80.2/76.2/73.5<br />

2.94<br />

PUHY-P1250YSGM-A<br />

Heating<br />

156.5<br />

533,900<br />

–<br />

42.63<br />

71.9/68.3/65.8<br />

3.67<br />

3-phase 4-wire 380/400/415V 50/60Hz<br />

PUHY-P550YMM-A PUHY-P650YSM-A PUHY-P600YMM-A PUHY-P650YSM-A<br />

Salt-resistant cross fin & copper tube<br />

Inverter scroll hermetic comp. + Scroll hermetic comp.<br />

Inverter + Direct<br />

11.2 + 5.3 / 10.9 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

11.6 + 5.3 / 11.6 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

φ41.28(φ1-5/8") Brazed<br />

φ28.58(φ1-1/8") Brazed<br />

φ19.05(φ3/4") Brazed<br />

φ15.88(φ5/8") Flare<br />

φ9.52(φ3/8") Flare<br />

R410A<br />

11.6 + 5.3 / 11.6 + 5.3<br />

11.6 + 5.3 / 11.6 + 5.3<br />

Propeller fan ✕ 2<br />

Propeller fan ✕ 2<br />

400<br />

400<br />

6,667<br />

6,667<br />

14,126<br />

14,126<br />

0.38 ✕ 2<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

64/65 65/65.5<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

458 (1010) 460 (1015) 458 (1010) 460 (1015)<br />

50~130% of outdoor unit capacity<br />

P20~P250 / 1~42<br />

1840 (72-1/2")<br />

1990 (78-3/8")<br />

840 (33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

1. Cooling/heating capacity indicates the maximum value at operation under the following condition.<br />

*1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

Pipe length: 7.5m(24-9/16Ft) Height difference: 0m<br />

*2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Pipe length: 5m(16-3/8Ft)<br />

Height difference: 0m<br />

*3 It is measured in anechoic room.<br />

17


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

Y SERIES<br />

R410A<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PUHY-P450,500,550,<br />

600,650YMM-A<br />

Refrig.service valve<br />

<br />

Refrig.service valve<br />

<br />

Knockout hole<br />

<br />

494<br />

Y<br />

Y<br />

1000<br />

Y<br />

ø27 Knockout hole<br />

<br />

Y<br />

553<br />

840<br />

845(mounting pitch) 16<br />

877<br />

145<br />

57 80<br />

76<br />

Conn. pipe<br />

<br />

ø28.58<br />

65 160<br />

768<br />

70 20<br />

ø62 Knockout hole<br />

80 <br />

Changeable to ø46,ø53 by using attached<br />

conduit mounting plate <br />

Cross section X–X<br />

Air outlet<br />

45<br />

950(mounting pitch)<br />

3✕2–14✕20 Oval hole<br />

(Mounting hole)<br />

1990<br />

Top view<br />

950(mounting pitch) 45<br />

ø53<br />

16<br />

265<br />

12 5<br />

Cross section Y–Y<br />

Air<br />

inlet<br />

<br />

• Refrigerant(Gas) conn.pipe....1pc.<br />

(Already installed on the unit)<br />

• Packing for conn.pipe....1pc.<br />

(Attached near the ball valve)<br />

• Conduit mounting plate<br />

ø53, ø46...1pc.Each<br />

• Tapping screw M4....2pcs.<br />

Note1.Use the opening at the bottom of the unit<br />

when running the power supply line from<br />

the front or from the side of the unit.<br />

Note2.Please refer to (2/2) for information<br />

regarding necessary spacing around the<br />

unit and foundation work.<br />

Note3.This unit is used in combination with<br />

a sub unit.(Refer to Drawing No.W656886<br />

Outline Drawing of Outdoor Unit set)<br />

10 89<br />

Air<br />

inlet<br />

37<br />

115<br />

Left side view<br />

ø27 Knockout hole<br />

<br />

80 40<br />

115<br />

37<br />

100<br />

134<br />

280<br />

Knockout hole<br />

<br />

Knockout hole<br />

Knockout hole<br />

<br />

235<br />

217<br />

194<br />

Refrig.service valve<br />

<br />

Service panel<br />

Refrig.service valve<br />

<br />

163<br />

X<br />

67 160<br />

100<br />

Service valve<br />

Conn. pipe <br />

68 205 ø15.88 ø9.52<br />

205 68<br />

285<br />

48<br />

Front view<br />

78<br />

11<br />

1575<br />

X<br />

1840<br />

PUHY-P450,650YSM-A<br />

Refrig.service valve<br />

<br />

Refrig.service valve<br />

<br />

Knockout hole<br />

<br />

494<br />

Y<br />

Y<br />

1000<br />

Y<br />

ø27 Knockout hole<br />

<br />

Y<br />

553<br />

840<br />

845(mounting pitch) 16<br />

877<br />

57 80<br />

92<br />

76<br />

65 160<br />

768<br />

70 20<br />

ø62 Knockout hole<br />

80 <br />

Changeable to ø46,ø53 by using attached<br />

conduit mounting plate <br />

Cross section X–X<br />

Air outlet<br />

45<br />

950(mounting pitch)<br />

3✕2–14✕20 Oval hole<br />

(Mounting hole)<br />

1990<br />

Top view<br />

950(mounting pitch) 45<br />

16<br />

ø53<br />

265<br />

12 5<br />

Cross section Y–Y<br />

<br />

• Gas distributor....1pc.<br />

(Already installed on the unit)<br />

• Liquid distributor....1pc.<br />

• Packing for conn. pipe....1pc.<br />

(Attached near the gas distributor)<br />

• Conduit mounting plate<br />

ø53, ø46....1pc.Each<br />

• Tapping screw M4....2pcs.<br />

• Conn. pipe(Gas)....2pcs.<br />

Note1.Use the opening at the bottom of the unit<br />

when running the power supply line from<br />

the front or from the side of the unit.<br />

Note2.Please refer to (2/2) for information<br />

regarding necessary spacing around the<br />

unit and foundation work.<br />

Note3.This unit is used in combination with<br />

a main unit.(Refer to Drawing No.W656886<br />

Outline Drawing of Outdoor Unit set)<br />

10 89<br />

Air<br />

inlet<br />

37<br />

115<br />

Left side view<br />

ø27 Knockout hole<br />

<br />

80 40<br />

115<br />

Air<br />

inlet<br />

37<br />

100<br />

134<br />

280<br />

Knockout hole<br />

<br />

Knockout hole<br />

Service panel<br />

Conn.pipe <br />

ø41.28<br />

Conn.pipe<br />

<br />

ø28.58<br />

45<br />

245<br />

235<br />

217<br />

Knockout hole<br />

<br />

X<br />

163<br />

67<br />

100<br />

68<br />

205<br />

285<br />

62<br />

160<br />

48<br />

Service valve<br />

ø9.52<br />

Conn.pipe<br />

ø15.88<br />

Front view<br />

205 68<br />

11 78<br />

1575<br />

X<br />

1840<br />

PUHY-P850,900,950,<br />

1000,1050,1100,1150,<br />

1200,1250YSGM-A<br />

877<br />

840<br />

Air outlet<br />

1990<br />

Main unit<br />

10<br />

1990<br />

Sub unit<br />

Air<br />

inlet<br />

Air<br />

inlet<br />

Distributor(Gas)<br />

f<br />

Left side view<br />

d<br />

c<br />

PUHY-P850YSGM-A PUHY-P900YSGM-A PUHY-P950YSGM-A PUHY-P1000YSGM-A PUHY-P1050YSGM-A PUHY-P1100YSGM-A PUHY-P1150YSGM-A PUHY-P1200YSGM-A PUHY-P1250YSGM-A<br />

Main unit<br />

PUHY-P450YMM-A PUHY-P500YMM-A PUHY-P550YMM-A PUHY-P600YMM-A PUHY-P650YMM-A PUHY-P450YMM-A PUHY-P500YMM-A PUHY-P550YMM-A PUHY-P600YMM-A<br />

Sub unit<br />

PUHY-P400YSM-A<br />

PUHY-P650YSM-A<br />

Indoor units~ Liquid a<br />

ø19.05<br />

Distributor Gas b<br />

ø41.28<br />

Distributor~ Liquid c<br />

ø15.88<br />

Main unit Gas d<br />

ø28.58<br />

Distributor~ Liquid e<br />

ø15.88<br />

Sub unit Gas f<br />

ø28.58<br />

Oil balance pipe g<br />

ø9.52<br />

b a<br />

Indoor units<br />

g<br />

e<br />

Distributor(Liquid)<br />

Note1.Pipe size is as show in the table on the left.<br />

Front view<br />

18


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

R2 SERIES<br />

R410A<br />

Model name<br />

Capacity<br />

Power source<br />

Power input<br />

Current<br />

COP<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

Airflow rate<br />

Compressor Fan Protection device<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Refrigerant piping diameter Gas side<br />

(mm(in.)) Liquid side<br />

Refrigerant type<br />

Noise level (dB) (A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

Indoor unit<br />

<strong>External</strong> dimension<br />

Temp. range of<br />

cooling<br />

Temp. range of<br />

heating<br />

(mm(in.))<br />

Indoor<br />

Outdoor<br />

Indoor<br />

Outdoor<br />

kW (*1)<br />

kcal/h (*2)<br />

BTU/h (*1)<br />

kW<br />

A<br />

m3/min<br />

L/s<br />

cfm<br />

kg (lbs)<br />

Total capacity<br />

Model/Quantity<br />

Height (H)<br />

Width (W)<br />

Depth (D)<br />

W.B.<br />

D.B.<br />

D.B<br />

W.B.<br />

Cooling<br />

22.4<br />

20,000<br />

76,400<br />

6.14<br />

10.3/9.8/9.4<br />

3.65<br />

4.7<br />

φ19.05(φ3/4") brazed<br />

φ15.88(φ5/8") brazed<br />

56<br />

236(521)<br />

Models P20~P250/1~15<br />

<strong>Specifications</strong><br />

PURY-P200YGM-A PURY-P250YGM-A PURY-P300YGM-A PURY-P350YGM-A PURY-P400YGM-A<br />

Heating Cooling Heating Cooling Heating Cooling Heating Cooling<br />

25.0<br />

28.0<br />

31.5<br />

33.5<br />

37.5<br />

40.0<br />

45.0<br />

45.0<br />

–<br />

25,000<br />

–<br />

30,000<br />

–<br />

35,000<br />

–<br />

40,000<br />

85,300 95,500 107,500<br />

136,500 153,500 153,500<br />

5.98<br />

10.0/9.5/9.2<br />

4.18<br />

114,300 128,000<br />

3N ~ 380/400/415V 50/60Hz<br />

Heating<br />

50.0<br />

–<br />

170,600<br />

7.72<br />

7.62<br />

9.57<br />

9.1<br />

11.39<br />

11.02<br />

13.42<br />

12.43<br />

13.0/12.3/11.9 12.8/12.2/11.7 16.1/15.3/14.7 15.3/14.5/14.0 19.2/18.2/17.6 18.6/17.6/17.0 22.6/21.5/20.7 20.9/19.9/19.2<br />

3.63<br />

4.13<br />

3.50<br />

4.12<br />

3.51<br />

4.08<br />

3.35<br />

4.02<br />

Salt Protected Fin<br />

Inverter scroll hermetic compressor<br />

Inverter<br />

6.7<br />

8.0<br />

Propeller fan ✕ 1<br />

9.6<br />

9.7<br />

200<br />

3,333<br />

7,063<br />

0.38<br />

240<br />

4,000<br />

8,476<br />

0.64<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

φ22.2(φ7/8") brazed<br />

φ28.58(φ1-1/8") brazed<br />

φ19.05(φ3/4") brazed<br />

φ22.2(φ7/8") brazed<br />

R410A<br />

57<br />

59<br />

60<br />

61<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

251(554)<br />

251(554)<br />

50~150% of outdoor unit capacity<br />

251(554)<br />

291(642)<br />

Models P20~P250/1~16 Models P20~P250/1~16<br />

1840(72-1/2")<br />

Models P20~P250/1~20 Models P20~P250/1~24<br />

990(39")<br />

1290(50-13/16")<br />

840(33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

Model name<br />

Capacity<br />

Power source<br />

Power input<br />

Current<br />

COP<br />

Heat exchanger type<br />

Type<br />

Starting method<br />

Motor output (kW)<br />

Type ✕ Quantity<br />

Airflow rate<br />

Compressor Fan Protection device<br />

Motor output (kW)<br />

High pressure protection<br />

Inverter circuit<br />

Compressor/fan<br />

Refrigerant piping diameter Gas side<br />

(mm(in.)) Liquid side<br />

Refrigerant type<br />

Noise level (dB) (A-characteristic value) (*3)<br />

<strong>External</strong> finish<br />

Net weight<br />

Indoor unit<br />

<strong>External</strong> dimension<br />

Temp. range of<br />

cooling<br />

Temp. range of<br />

heating<br />

(mm(in.))<br />

Indoor<br />

Outdoor<br />

Indoor<br />

Outdoor<br />

kW (*1)<br />

kcal/h (*2)<br />

BTU/h (*1)<br />

kW<br />

A<br />

m3/min<br />

L/s<br />

cfm<br />

kg (lbs)<br />

Total capacity<br />

Model/Quantity<br />

Height (H)<br />

Width (W)<br />

Depth (D)<br />

W.B.<br />

D.B.<br />

D.B<br />

W.B.<br />

PURY-P450YGM-A PURY-P500YGM-A PURY-P550YGM-A PURY-P600YGM-A PURY-P650YGM-A<br />

Heating Cooling Heating Cooling Heating Cooling Heating Cooling<br />

56.0<br />

56.0<br />

63.0<br />

63.0<br />

67.0<br />

67.4<br />

75.0<br />

73.0<br />

–<br />

50,000<br />

–<br />

55,000<br />

–<br />

60,000<br />

–<br />

65,000<br />

191,100 191,100 215,000<br />

230,000 255,900 249,100<br />

Cooling<br />

50.0<br />

45,000<br />

170,600<br />

215,000 228,600<br />

3N ~ 380/400/415V 50/60Hz<br />

13.61<br />

13.86<br />

15.59<br />

15.89<br />

17.08<br />

16.37<br />

17.59<br />

17.73<br />

22.9/21.8/21.0 23.3/22.2/21.4 26.3/25.0/24.0 26.8/25.4/24.5 28.8/27.3/26.4 27.6/26.2/25.3 29.6/28.2/27.1 29.9/28.4/27.4<br />

3.67<br />

4.04<br />

3.59<br />

3.96<br />

3.69<br />

4.09<br />

3.83<br />

4.23<br />

Salt Protected Fin<br />

Inverter scroll hermetic compressor<br />

Inverter<br />

6.8 + 5.3<br />

Propeller fan ✕ 1<br />

8.2 + 5.3<br />

9.3 + 5.3<br />

Propeller fan ✕ 2<br />

400<br />

10.1 + 5.3<br />

6,667<br />

14,126<br />

0.38 ✕ 2<br />

High pressure switch 4.15MPa (601 psi)<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

Over-heat protection/Thermal switch<br />

φ28.58(φ1-1/8") brazed<br />

φ22.2(φ7/8") brazed<br />

φ28.58(φ1-1/8") brazed<br />

R410A<br />

60/61 (50Hz/60Hz) 61/62 (50Hz/60Hz)<br />

Pre-coated galvanized sheets + powder coating (for-BS type) <br />

481(1061)<br />

481(1061)<br />

481(1061)<br />

50~150% of outdoor unit capacity<br />

481(1061)<br />

Models P20~P250/1~24 Models P20~P250/1~24 Models P20~P250/1~24 Models P20~P250/1~32<br />

1840(72-1/2")<br />

1990(78-3/8")<br />

840(33-1/8")<br />

15~24˚C (59~75˚F)<br />

-5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors)<br />

15~27˚C (59~81˚F)<br />

-20~15.5˚C (-4~60˚F)<br />

Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition.<br />

*1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

Pipe length: 7.5m(24-9/16Ft) Height difference: 0m<br />

PURY-P200,250,300,350YGM-A<br />

Conn. pipe<br />

(low pressure)<br />

200:ø19.05<br />

250:ø22.2 <br />

300:ø22.2 <br />

350:ø28.58<br />

Conn. pipe<br />

(high pressure)<br />

A<br />

57 80<br />

200:ø15.88<br />

250:ø19.05<br />

300:ø19.05<br />

350:ø19.05<br />

65 160<br />

494<br />

B<br />

768<br />

Y<br />

Y<br />

Knockout hole<br />

<br />

Cross section X–X<br />

80<br />

<strong>External</strong> <strong>Dimensions</strong><br />

ø27 Knockout hole<br />

<br />

70 20<br />

553<br />

ø62 Knockout hole <br />

Changeable to ø27,ø33 by using<br />

attached conduit mounting plate <br />

Air outlet<br />

*2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB<br />

Pipe length: 5m(16-3/8Ft)<br />

Height difference: 0m<br />

2X2-14X20 0val hole<br />

45 900(bolt hole) 45<br />

990<br />

Plane view<br />

16<br />

840<br />

16 845(bolt hole)<br />

877<br />

19.65<br />

33.1/31.5/30.3<br />

3.72<br />

10.9 + 5.3<br />

Heating<br />

81.5<br />

–<br />

278,100<br />

19.82<br />

33.4/31.7/30.6<br />

4.11<br />

62/62.5 (50Hz/60Hz)<br />

481(1061)<br />

Models P20~P250/1~32<br />

*3 It is measured in anechoic room.<br />

Unit : mm<br />

265<br />

Model A B<br />

200 145 115<br />

250 135 120<br />

300 135 120<br />

350 145 120<br />

ø53<br />

19<br />

12 5<br />

Cross section Y–Y<br />

[Accessories]<br />

• Refrigerant (high pressure) conn. pipe..............1pc.<br />

• Refrigerant (low pressure) conn. pipe................1pc.<br />

(The connecting pipe has been fixed with the unit)<br />

• Packing for conn. low pressure pipe..................1pc.<br />

(Attached near the ball valve)<br />

• Conduit mouting plate<br />

ø33, ø27............................Each 1pc.<br />

• Tapping screw M4.....................1pcs.<br />

Air<br />

inlet<br />

10 90<br />

37<br />

117<br />

Left side view<br />

ø27 Knockout hole<br />

<br />

80 40<br />

117<br />

Air<br />

inlet<br />

134 100<br />

280<br />

Knockout hole<br />

Service panel<br />

Refrig. service<br />

valve (high pressure)<br />

67 160<br />

<br />

X<br />

15<br />

235<br />

184<br />

Refrig. service<br />

100<br />

valve(low pressure)<br />

37<br />

<br />

Knockout hole<br />

<br />

67<br />

83<br />

207<br />

Knockout hole<br />

<br />

Front view<br />

207<br />

67<br />

X<br />

78<br />

11<br />

1575<br />

1840


OUTDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

R2 SERIES<br />

R410A<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PURY-P400YGM-A<br />

644<br />

Unit : mm<br />

81<br />

1200(bolt hole) 45<br />

1290<br />

Plane view<br />

840<br />

16 845(bolt hole)<br />

877<br />

15<br />

184<br />

494<br />

1000<br />

553<br />

840<br />

845(bolt hole) 16<br />

877<br />

145<br />

57 80<br />

Conn. pipe<br />

(low pressure)<br />

ø28.58<br />

65 160<br />

145<br />

768<br />

Conn. pipe<br />

(high pressure)<br />

450:ø22.2 <br />

500:ø22.2 <br />

550:ø28.58<br />

600:ø28.58<br />

650:ø28.58<br />

70 20<br />

3X2-14X20 Oval hole<br />

45<br />

950(bolt hole)<br />

1990<br />

Plane view<br />

950(bolt hole) 45<br />

ø53<br />

16<br />

Knockout hole<br />

<br />

145<br />

80<br />

57<br />

Conn. pipe<br />

(low pressure)<br />

ø28.58<br />

65 160<br />

1068<br />

Cross section X–X<br />

Conn. pipe<br />

(high pressure)<br />

ø22.2 <br />

Y<br />

Y<br />

80<br />

70 20<br />

ø27 Knockout hole<br />

<br />

503<br />

ø62 Knockout hole<br />

<br />

Changeable to ø46,ø53 by using<br />

attached conduit mounting plate <br />

Air outlet<br />

2X2-14X20 Oval hole<br />

45<br />

12<br />

5<br />

ø53<br />

Cross section Y–Y<br />

[Accessories]<br />

• Refrigerant (high pressure) conn. pipe........... 1pc.<br />

(The connecting pipe has been fixed with the unit)<br />

• Refrigerant (low pressure) conn. pipe............. 1pc.<br />

(The connecting pipe has been fixed with the unit)<br />

• Packing for conn. high pressure pipe.............. 1pc.<br />

(Attached near the ball valve)<br />

• Packing for conn. low pressure pipe............... 1pc.<br />

(Attached near the ball valve)<br />

• Conduit mouting plate<br />

ø53, ø46................... Each 1pc.<br />

• Tapping screw M4............ 2pcs.<br />

Air<br />

inlet<br />

89<br />

10<br />

135<br />

40<br />

37 115 115 37<br />

Left side view<br />

80<br />

Air<br />

inlet<br />

ø27 Knockout hole<br />

<br />

134 100<br />

280<br />

Knockout hole<br />

Service panel<br />

Refrig. service<br />

valve (high pressure)<br />

<br />

235<br />

Refrig. service<br />

valve(low pressure)<br />

<br />

Knockout hole<br />

<br />

X<br />

100<br />

67 160<br />

68<br />

83<br />

355<br />

Knockout hole<br />

<br />

Front view<br />

355<br />

68<br />

X<br />

11 78<br />

1575 265<br />

1840<br />

PURY-P450,500,550,600,650YGM-A<br />

Knockout hole<br />

<br />

Y<br />

Y<br />

ø27 Knockout hole<br />

<br />

Y<br />

Y<br />

ø62 Knockout hole<br />

<br />

80<br />

Changeable to ø46,ø53 by using<br />

attached conduit mounting plate <br />

Cross section X–X<br />

Air outlet<br />

16<br />

265<br />

12 5<br />

Cross section Y–Y<br />

[Accessories]<br />

• Refrigerant (high pressure) conn. pipe.......... 1 pc.<br />

(The connecting pipe has been fixed with the unit)<br />

• Refrigerant (low pressure) conn. pipe............ 1 pc.<br />

(The connecting pipe has been fixed with the unit)<br />

• Packing for conn. high pressure pipe............. 1 pc.<br />

(Attached near the ball valve)<br />

• Packing for conn. low pressure pipe.............. 1 pc.<br />

(Attached near the ball valve)<br />

• Conduit mouting plate<br />

ø53, ø46..................... Each 1 pc.<br />

• Tapping screw M4.............. 2 pcs.<br />

Air<br />

inlet<br />

10 89<br />

37<br />

115<br />

Left side view<br />

135<br />

80 40<br />

115<br />

Air<br />

inlet<br />

ø27 Knockout hole<br />

<br />

100<br />

134<br />

280<br />

Knockout hole<br />

Service panel<br />

Refrig. service<br />

valve (high pressure)<br />

<br />

Knockout hole X<br />

<br />

235<br />

44<br />

150<br />

67 160<br />

Refrig. service<br />

valve(low pressure) 100 90<br />

37<br />

<br />

Knockout hole<br />

68 205 290 260<br />

260 290 205 68<br />

<br />

Front view<br />

78<br />

11<br />

1575<br />

X<br />

1840<br />

20


HEAT SOURCE UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

WY SERIES<br />

R410A<br />

Model name<br />

Capacity<br />

Power source<br />

Power input<br />

Current<br />

COP<br />

Compressor<br />

Heat<br />

exchanger<br />

Type<br />

Motor output<br />

Type<br />

Water volume in the coil<br />

Circulating Volume<br />

water<br />

Pressure drop<br />

Refrigerant<br />

<strong>External</strong> finish<br />

Height(H)<br />

<strong>External</strong> dimension Width(W)<br />

Depth(D)<br />

Protection<br />

devices<br />

High pressure protection<br />

Compressor<br />

Inverter<br />

Gas/Liquid<br />

Total capacity<br />

Model / Quantity<br />

Refrigerant piping diameter<br />

Indoor<br />

unit<br />

Noise level<br />

Net weight<br />

Operating temperature range<br />

kW<br />

BTU/h<br />

kW<br />

A<br />

kW<br />

R<br />

m3/h<br />

cfh<br />

kPa<br />

mm(in.)<br />

dB<br />

kg(lbs.)<br />

PQHY-P200YGM-A<br />

Cooling<br />

22.4<br />

76,400<br />

4.79<br />

8.0/7.6/7.4<br />

4.68<br />

107,500 153,500<br />

3N~380/400/415V 50/60Hz<br />

Inverter scroll hermetic compressor<br />

Galvanized sheets<br />

1,800(70-7/ 8")<br />

990(39") 1,980(78")<br />

550(21-11/ 16")<br />

High pressure switch 4.15 MPa (601psi)<br />

Over-heat protection<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

ø9.52 flare / ø19.05 Flange ø9.52 flare /ø22.2 Flange ø12.7 flare / ø28.58 Flange ø15.88 flare / ø28.58 Flange<br />

50%~130% of heat sourse unit capacity<br />

Indoor:15˚CWB~24˚CWB<br />

Water :10˚C~45˚C<br />

5.0<br />

Double coil<br />

9.5<br />

4.56<br />

161<br />

16.5<br />

R410A<br />

Heating<br />

25.0<br />

85,300<br />

4.69<br />

7.9/7.5/7.2<br />

5.33<br />

Model P20~250/1~13<br />

46<br />

272(600)<br />

Indoor:15˚CDB~27CDB<br />

Water :10˚C~45˚C<br />

<strong>Specifications</strong><br />

PQHY-P250YGM-A<br />

Cooling<br />

28.0<br />

95,500<br />

5.95<br />

10.0/9.5/9.1<br />

4.71<br />

Indoor:15˚CWB~24˚CWB<br />

Water :10˚C~45˚C<br />

6.0<br />

Double coil<br />

10.5<br />

5.76<br />

203<br />

19.5<br />

R410A<br />

Heating<br />

31.5<br />

5.80<br />

9.7/9.3/8.9<br />

5.43<br />

Model P20~250/1~16<br />

47<br />

275(607)<br />

Note: 1.Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling Indoor:27˚C(80.6˚F)DB/19˚CWB<br />

Water temperature: 30˚C(80˚F)<br />

Heating Indoor:20˚C(68˚F)DB<br />

Water temperature:20˚C(68˚F)<br />

Pipe length:7.5m(24-9/16Ft) Height difference:0m<br />

2.The ambient temperature of heat source unit has to be kept below 40˚C(104˚F)(dry bulb).<br />

The ambient relative humidity of heat source unit has to be kept below 80%.<br />

3.This unit can not be installed in the outdoor.(No protection against the weather.)<br />

4.It is measured in anechoic room.<br />

5.When the total capacity of indoor units exceeds 130% of heat source units capacity,<br />

the operating temperature range of circulating water is 15˚C(59˚F)~45˚C(113˚F)<br />

Indoor:15˚CDB~27˚CDB<br />

Water :10˚C~45˚C<br />

PQHY-P400YSGM-A<br />

Cooling<br />

45.0<br />

11.35<br />

19.1/18.2/17.5<br />

3.96<br />

Indoor:15˚CWB~24˚CWB<br />

Water :10˚C~45˚C<br />

9.7<br />

Double coil<br />

17.5<br />

9.12<br />

322<br />

16.5<br />

R410A<br />

Heating<br />

50.0<br />

170,600<br />

11.01<br />

18.5/17.6/17.0<br />

4.54<br />

Model P20~250/1~22<br />

50<br />

208+244(459+538)<br />

Indoor:15˚CDB~27˚CDB<br />

Water :10˚C~45˚C<br />

PQHY-P500YSGM-A<br />

Cooling<br />

56.0<br />

191,100<br />

15.06<br />

25.4/24.2/23.3<br />

3.72<br />

Indoor:15˚CWB~24˚CWB<br />

Water :10˚C~45˚C<br />

11.6<br />

Double coil<br />

19.5<br />

11.52<br />

407<br />

19.5<br />

R410A<br />

Heating<br />

63.0<br />

215,000<br />

13.60<br />

22.9/21.8/21.0<br />

4.63<br />

Model P20~250/1~24<br />

53<br />

208+248(459+547)<br />

Indoor:15˚CDB~27˚CDB<br />

Water :10˚C~45˚C<br />

PQHY-P200,P250YGM-A<br />

ø38 Knockout hole<br />

<br />

Water outlet<br />

(PT1 1/2 screw)<br />

ø62 Knockout hole<br />

<br />

924<br />

415<br />

255<br />

140<br />

126<br />

94<br />

50<br />

ø38 Knockout hole<br />

<br />

Water inlet<br />

(PT1 1/2 screw)<br />

ø40 <br />

126<br />

95<br />

ø27 Knockout hole<br />

<br />

1397<br />

1497<br />

1579<br />

415<br />

255<br />

1598<br />

1626<br />

A<br />

B<br />

<strong>External</strong> <strong>Dimensions</strong><br />

990<br />

45 900(mounting pitch)<br />

45<br />

Note 1<br />

Water inlet<br />

(PT1 1/2 screw)<br />

495<br />

Note 1<br />

Water outlet<br />

(PT1 1/2 screw)<br />

256 ø70<br />

154<br />

123<br />

ø38 Knockout hole<br />

206<br />

<br />

318<br />

ø27 Knockout hole<br />

568 <br />

Plane view<br />

69<br />

Conn. pipe<br />

200:ø9.52<br />

250:ø9.52<br />

Conn. pipe<br />

200:ø19.05<br />

250:ø22.2<br />

Refrig. service valve<br />

Refrig. service valve<br />

Knockout hole<br />

Drain<br />

(PT1 screw)<br />

2X2-14X20 Oval hole<br />

(mounting hole)<br />

550<br />

570(mounting pitch)<br />

602<br />

16<br />

1590<br />

1772<br />

(1800)<br />

939<br />

879<br />

108<br />

78<br />

ø27 Knockout hole<br />

<br />

ø38 Knockout hole<br />

<br />

Piping space<br />

(left side pipe)<br />

Piping space<br />

(left side pipe)<br />

400<br />

Fig. A<br />

Note 2<br />

Drain(PT1 screw)<br />

Plane view<br />

Service space<br />

(front side)<br />

Front view<br />

400 600<br />

Piping space<br />

(upside pipe)<br />

21<br />

[Accessories]<br />

• Refrigerant conn. pipe........... 1pc.<br />

• Packing for conn. pipe.................... 1pc.<br />

(Attached near the ball valve)<br />

• Bushing......................................... 2pcs.<br />

495<br />

Model A B<br />

Left side view Front view Right side view Rear view<br />

P200 1346 1289<br />

P250 1346 1299<br />

127<br />

182<br />

Note 1. At the time of product shipment, the front side piping specification serves as the local drainage connection. When connecting on the rear side, please remove the rear side plug<br />

sealing corks, and attach to a front side. Ensure there is no leak after the attachment has been fitted.<br />

2. Take notice of service space as Fig. A (In case of single setting, 600mm or more of back space as front space makes easier access when servicing the unit from the rear side.)<br />

3. In case the temperature around the heat source unit has possibility to drop under 0°C, be careful for the following point to prevent the pipe burst by the water pipe freeze-up.<br />

• Circulate the water all the time even if the heat source unit is not in operation.<br />

• Drain the water from inside of the heat source unit when the heat source unit will not operate for a long term.


HEAT SOURCE UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

WY SERIES<br />

R410A<br />

PQHY-P400,P500YSGM-A<br />

<strong>External</strong> <strong>Dimensions</strong><br />

2X2-14X20 Oval hole<br />

(mounting hole)<br />

418<br />

272<br />

126<br />

990<br />

45 900(mounting pitch)<br />

Water inlet<br />

(PT2 screw)<br />

1990<br />

10<br />

990<br />

900(mounting pitch)<br />

Water outlet<br />

(PT2 screw)<br />

69<br />

154<br />

45<br />

2X2-14X20 Oval hole<br />

(mounting hole)<br />

550<br />

570(mounting pitch)<br />

602<br />

Piping space<br />

(left side pipe)<br />

400<br />

Plane view<br />

Service space<br />

(front side)<br />

Piping space<br />

(upside pipe)<br />

600<br />

400<br />

418<br />

ø70<br />

143<br />

233<br />

ø56<br />

<br />

719<br />

318<br />

Plane view<br />

568<br />

16<br />

ø38 Knockout hole<br />

<br />

ø27 Knockout hole<br />

<br />

Front view<br />

Piping space<br />

(left side pipe)<br />

Fig. A<br />

272<br />

Water outlet<br />

(PT2 screw)<br />

Water inlet<br />

(PT2 screw)<br />

76<br />

131<br />

1599<br />

(1800)<br />

Heat exchanger unit<br />

Conn. pipe<br />

P400:ø28.58<br />

P500:ø28.58<br />

Conn. pipe<br />

P400:ø12.7<br />

P500:ø15.88<br />

Refrig. service valve<br />

<br />

Compressor unit<br />

Knockout hole<br />

1590<br />

1772<br />

78<br />

108<br />

ø27 Knockout hole<br />

<br />

Knockout hole<br />

<br />

126<br />

660<br />

950<br />

624<br />

585<br />

Refrig. service<br />

valve<br />

Drain<br />

(PT1 screw)<br />

127<br />

182<br />

939<br />

879<br />

ø38 Knockout hole<br />

<br />

Left side view<br />

[Accessories]<br />

• Refrigerant conn.pipe.............................................. 1pc.<br />

(The connecting pipe is fixed with the unit)<br />

• Refrigerant conn.pipe........................................... 1pc.<br />

(Packaged in the accessory kit)<br />

• Refrigerant conn.pipe between HEX unit and Compressor unit<br />

ø9.52................................................................................ 2pcs.<br />

(Packaged in the accessory kit)<br />

ø19.05.............................................................................. 2pcs.<br />

(Packaged in the accessory kit)<br />

ø25.4................................................................................ 2pcs.<br />

(Packaged in the accessory kit : HEX unit)<br />

(The connecting pipe is fixed with the unit : Compressor unit)<br />

• Packing for conn.pipe....................................................... 4pcs.<br />

(Attached near the ball valve)<br />

• Bushing............................................................................. 6pcs.<br />

• Extension code for water heat source............................... 1set<br />

Drain<br />

(PT1 screw)<br />

Front view<br />

Locally piping<br />

ø9.52 <br />

ø19.05 <br />

ø25.4 <br />

Conn.pipe between HEX unit<br />

and Compressor unit<br />

(Extension code for water heat source)<br />

Control signal wire<br />

<br />

Right side view<br />

Note 1. At the time of product shipment, the front side piping specification serves as the local drainage connection. When connecting on the rear side, please remove the rear side plug sealing corks, and attach to a front side. Ensure<br />

there is no leak after the attachment has been fitted.<br />

2. Take notice of service space as Fig. A (In case of single setting, 600mm or more of back space as front space makes easier access when servicing the unit from the rear side.)<br />

3. In case the temperature around the heat source unit has possibility to drop under 0°C, be careful for the following point to prevent the pipe burst by the water pipe freeze-up.<br />

• Circulate the water all the time even if the heat source unit is not in operation.<br />

• Drain the water from inside of the heat source unit when the heat source unit will not operate for a long term.<br />

4. Use the extension code for water heat source (option) to take space (more than 2m) between HEX unit Compressor unit.<br />

22


HEAT SOURCE UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

WR2 SERIES<br />

Model name<br />

Capacity<br />

Power source<br />

Power input<br />

Current<br />

COP<br />

Compressor<br />

Heat<br />

exchanger<br />

R410A<br />

Type<br />

Motor output<br />

Type<br />

Water volume in the coil<br />

Circulating Volume<br />

water<br />

Pressure drop<br />

Refrigerant<br />

<strong>External</strong> finish<br />

Height(H)<br />

<strong>External</strong> dimension Width(W)<br />

Depth(D)<br />

Protection<br />

devices<br />

High pressure protection<br />

Compressor<br />

Inverter<br />

gas / Liquid<br />

Refrigerant piping diameter<br />

indoor Total capacity<br />

unit Model / Quantity<br />

Noise level<br />

Net weight<br />

Operating temperature range<br />

kW<br />

BTU/h<br />

kW<br />

A<br />

kW<br />

R<br />

m3/h<br />

cfh<br />

kPa<br />

mm(in.)<br />

dB<br />

kg(lbs)<br />

PQRY-P200,P250YGM-A<br />

PQRY-P200YGM-A<br />

Cooling<br />

22.4<br />

76,400<br />

4.79<br />

8.0/7.6/7.4<br />

4.68<br />

5.0<br />

Double coil<br />

9.5<br />

4.56<br />

161<br />

16.5<br />

R410A<br />

Heating<br />

25.0<br />

85,300<br />

4.69<br />

7.9/7.5/7.2<br />

5.33<br />

<strong>Specifications</strong><br />

107,500 153,500<br />

3N~380/400/415V 50/60Hz<br />

Inverter scroll hermetic compressor<br />

Galvanized sheets<br />

1,800(70-7/ 8 ")<br />

990(39") 1,980(78")<br />

550(21-11/ 16 ")<br />

High pressure switch 4.15 MPa (601psi)<br />

Over-heat protection<br />

Over-voltage and over-current protection for AC bus, Over-heat protection<br />

ø15.88 flare / ø19.05 Flange ø19.05 flare /ø22.2 Flange ø22.2 flare / ø28.58 Flange ø22.2 flare / ø28.58 Flange<br />

50%~150% of heat sourse unit capacity<br />

Model P20~250/1~15<br />

46<br />

263(580)<br />

Indoor:15˚CWB~24˚CWB<br />

Water :10˚C~45˚C<br />

Indoor:15˚CDB~27CDB<br />

Water :10˚C~45˚C<br />

PQRY-P250YGM-A<br />

Cooling<br />

28.0<br />

95,500<br />

5.95<br />

10.0/9.5/9.1<br />

4.71<br />

Indoor:15˚CWB~24˚CWB<br />

Water :10˚C~45˚C<br />

6.0<br />

Double coil<br />

10.5<br />

5.76<br />

203<br />

19.5<br />

R410A<br />

Heating<br />

31.5<br />

5.8<br />

9.7/9.3/8.9<br />

5.43<br />

Model P20~250/1~19<br />

47<br />

266(587)<br />

Note: 1.Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling Indoor:27˚C(80.6˚F)DB/19˚CWB<br />

Water temperature: 30˚C(80˚F)<br />

Heating Indoor:20˚C(68˚F)DB<br />

Water temperature:20˚C(68˚F)<br />

Pipe length:7.5m(24-9/16Ft) Height difference:0m<br />

2.The ambient temperature of heat source unit has to be kept below 40˚C(104˚F)(dry bulb).<br />

The ambient relative humidity of heat source unit has to be kept below 80%.<br />

ø38 Knockout hole<br />

<br />

Water outlet<br />

(PT1 1/2 screw)<br />

ø62 Knockout hole<br />

<br />

924<br />

415<br />

255<br />

140<br />

126<br />

94<br />

50<br />

ø38 Knockout hole<br />

<br />

Water inlet<br />

(PT1 1/2 screw)<br />

1397<br />

1497<br />

1579<br />

415<br />

255<br />

1598<br />

1626<br />

ø40 <br />

126<br />

95<br />

ø27 Knockout hole<br />

<br />

A<br />

B<br />

256<br />

495<br />

123<br />

206<br />

318<br />

568<br />

69<br />

Indoor:15˚CDB~27˚CDB<br />

Water :10˚C~45˚C<br />

<strong>External</strong> <strong>Dimensions</strong><br />

990<br />

45 900(mounting pitch)<br />

45<br />

Note 1 Water inlet<br />

(PT1 1/2 screw)<br />

Note 1 Water outlet<br />

(PT1 1/2 screw)<br />

ø70<br />

154<br />

550<br />

570(mounting pitch)<br />

602<br />

ø38 Knockout hole<br />

<br />

ø27 Knockout hole<br />

<br />

Plane view<br />

Conn. pipe<br />

200:ø15.88<br />

250:ø19.05<br />

Conn. pipe<br />

200:ø19.05<br />

250:ø22.2 <br />

Refrig. service valve<br />

<br />

Refrig. service valve<br />

<br />

Knockout hole<br />

Drain<br />

(PT1 screw)<br />

16<br />

1590<br />

1772<br />

(1800)<br />

PQRY-P400YSGM-A<br />

Cooling<br />

45.0<br />

11.35<br />

19.1/18.2/17.5<br />

3.96<br />

Indoor:15˚CWB~24˚CWB<br />

Water :10˚C~45˚C<br />

9.7<br />

Double coil<br />

17.5<br />

9.12<br />

322<br />

16.5<br />

R410A<br />

Heating<br />

50.0<br />

170,600<br />

11.01<br />

18.5/17.6/17.0<br />

4.54<br />

Model P20~250/1~24<br />

50<br />

208+232(459+512)<br />

Indoor:15˚CDB~27˚CDB<br />

Water :10˚C~45˚C<br />

PQRY-P500YSGM-A<br />

Cooling<br />

56.0<br />

191,100<br />

15.06<br />

25.4/24.2/23.3<br />

3.72<br />

Indoor:15˚CWB~24˚CWB<br />

Water :10˚C~45˚C<br />

11.6<br />

Double coil<br />

19.5<br />

11.52<br />

407<br />

19.5<br />

R410A<br />

Heating<br />

63.0<br />

215,000<br />

13.6<br />

22.9/21.8/21.0<br />

4.63<br />

Model P20~250/1~24<br />

53<br />

208+236(459+521)<br />

Indoor:15˚CDB~27˚CDB<br />

Water :10˚C~45˚C<br />

3.This unit can not be installed in the outdoor.(No protection against the weather.)<br />

4.It is measured in anechoic room.<br />

5.When the total capacity of indoor units exceeds 130% of heat source units capacity,<br />

the operating temperature range of circulating water is 15˚C(59˚F)~45˚C(113˚F)<br />

2X2-14X20 Oval hole<br />

(mounting hole)<br />

939<br />

879<br />

ø27 Knockout hole<br />

<br />

78<br />

ø38 Knockout hole<br />

<br />

Piping space<br />

(left side pipe)<br />

Piping space<br />

(left side pipe)<br />

400<br />

Plane view<br />

Service space<br />

(front side)<br />

Front view<br />

Fig. A<br />

Note 2<br />

Drain(PT1 screw)<br />

400 600<br />

Piping space<br />

(upside pipe)<br />

23<br />

[Accessories]<br />

• Refrigerant conn. pipe.......... 1pc.<br />

(The connecting pipe is fixed with the unit)<br />

• Refrigerant conn. pipe......... 1pc.<br />

(Packaged in the accsessory kit)<br />

• Packing for conn. pipe.................................... 1pc.<br />

(Attached near the ball valve)<br />

• Bushing......................................................... 2pcs.<br />

495<br />

Model A B<br />

Left side view Front view Right side view Rear view<br />

P200 1347 1289<br />

P250 1342 1299<br />

127<br />

182<br />

Note 1. At the time of product shipment, the front side piping specification serves as the local drainage connection. When connecting on the rear side, please remove the rear side plug<br />

sealing corks, and attach to a front side. Ensure there is no leak after the attachment has been fitted.<br />

2. Take notice of service space as Fig. A (In case of single setting, 600mm or more of back space as front space makes easier access when servicing the unit from the rear side.)<br />

3. In case the temperature around the heat source unit has possibility to drop under 0°C, be careful for the following point to prevent the pipe burst by the water pipe freeze-up.<br />

• Circulate the water all the time even if the heat source unit is not in operation.<br />

• Drain the water from inside of the heat source unit when the heat source unit will not operate for a long term.


HEAT SOURCE UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

WR2 SERIES<br />

R410A<br />

PQRY-P400,P500YSGM-A<br />

<strong>External</strong> <strong>Dimensions</strong><br />

126<br />

990<br />

45 900(mounting pitch)<br />

Water inlet<br />

2X2-14X20 Oval hole (PT2 screw)<br />

(mounting hole)<br />

418<br />

272<br />

1990<br />

10<br />

990<br />

900(mounting pitch)<br />

Water outlet<br />

(PT2 screw)<br />

69<br />

154<br />

45<br />

2X2-14X20 Oval hole<br />

(mounting hole)<br />

550<br />

570(mounting pitch)<br />

602<br />

Piping space<br />

(left side pipe)<br />

Plane view<br />

Service space<br />

(front side)<br />

Piping space<br />

400<br />

(upside pipe)<br />

600<br />

400<br />

418<br />

ø70<br />

143<br />

233<br />

ø56<br />

<br />

719<br />

318<br />

Plane view<br />

568<br />

16<br />

ø38 Knockout hole<br />

<br />

ø27 Knockout hole<br />

<br />

Front view<br />

Piping space<br />

(left side pipe)<br />

Fig. A<br />

272<br />

Water outlet<br />

(PT2 screw)<br />

Water inlet<br />

(PT2 screw)<br />

76<br />

131<br />

1599<br />

(1800)<br />

Heat exchanger unit<br />

Conn. pipe<br />

ø28.58<br />

Conn. pipe<br />

<br />

ø22.2<br />

Refrig.<br />

service valve<br />

<br />

Compressor unit<br />

Knockout hole<br />

1590<br />

1772<br />

78<br />

108<br />

ø27 Knockout hole<br />

<br />

Knockout hole<br />

<br />

126<br />

Left side view<br />

[Accessories]<br />

• Refrigerant conn.pipe....................................................... 2pcs.<br />

(The connecting pipe is fixed with the unit)<br />

• Refrigerant conn.pipe between HEX unit and Compressor unit<br />

ø9.52................................................................................ 2pcs.<br />

(Packaged in the accessory kit)<br />

ø19.05.............................................................................. 2pcs.<br />

(Packaged in the accessory kit)<br />

ø25.4................................................................................ 2pcs.<br />

(Packaged in the accessory kit : HEX unit)<br />

(The connecting pipe is fixed with the unit : Compressor unit)<br />

• Packing for conn.pipe....................................................... 4pcs.<br />

(Attached near the ball valve)<br />

• Bushing............................................................................ 2pcs.<br />

• Extension code for water heat source............................... 1set<br />

660<br />

950<br />

648<br />

585<br />

Refrig.<br />

service<br />

valve<br />

<br />

Drain<br />

(PT1 screw)<br />

Front view<br />

Locally piping<br />

ø9.52 <br />

ø19.05 <br />

ø25.4 <br />

Drain<br />

(PT1 screw)<br />

127<br />

182<br />

Conn.pipe between HEX unit<br />

and Compressor unit<br />

(Extension code for water heat source)<br />

Control signal wire<br />

<br />

939<br />

879<br />

Right side view<br />

ø38 Knockout hole<br />

<br />

Note 1. At the time of product shipment, the front side piping specification serves as the local drainage connection. When connecting on the rear side, please remove the rear side plug sealing corks, and attach to a front side. Ensure<br />

there is no leak after the attachment has been fitted.<br />

2. Take notice of service space as Fig. A (In case of single setting, 600mm or more of back space as front space makes easier access when servicing the unit from the rear side.)<br />

3. In case the temperature around the heat source unit has possibility to drop under 0°C, be careful for the following point to prevent the pipe burst by the water pipe freeze-up.<br />

• Circulate the water all the time even if the heat source unit is not in operation.<br />

• Drain the water from inside of the heat source unit when the heat source unit will not operate for a long term.<br />

4. Use the extension code for water heat source (option) to take space (more than 2m) between HEX unit and Compressor unit.<br />

24


BC CONTROLLER<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

BC Controller for<br />

R2/WR2 SERIES<br />

R410A<br />

CMB-P-V-G<br />

CMB-P-V-GA<br />

CMB-P-V-GB<br />

Model name<br />

Number of branch<br />

Power source<br />

Power input<br />

Current<br />

<strong>External</strong> finish<br />

Indoor unit capacity<br />

connectable to 1 branch *<br />

Conncctable Outdoor unit<br />

Height<br />

Width<br />

Depth<br />

Refrigerant<br />

piping<br />

diameter<br />

Drain pipe<br />

Net weight<br />

Accessories<br />

To outdoor<br />

unit<br />

To indoor<br />

unit<br />

To another<br />

BC controller<br />

50Hz<br />

kW<br />

60Hz<br />

A<br />

50Hz<br />

60Hz<br />

mm<br />

mm<br />

mm<br />

High pressure<br />

pipe<br />

Low pressure<br />

pipe<br />

Liquid pipe<br />

Gas pipe<br />

Low press gas<br />

pipe<br />

High press gas<br />

pipe<br />

Liquid pipe<br />

Cooling<br />

heating<br />

Cooling<br />

heating<br />

Cooling<br />

heating<br />

Cooling<br />

heating<br />

<strong>Specifications</strong><br />

CMB-P-V-GB<br />

CMB-P104V-G CMB-P105V-G CMB-P106V-G CMB-P108V-G CMB-P1010V-G CMB-P1013V-G CMB-P1016V-G CMB-P108V-GA CMB-P1010V-GA CMB-P1013V-GA CMB-P1016V-GA CMB-P104V-GB CMB-P108V-GB<br />

4 5 6 8 10 13 16 8 10 13 16 4 8<br />

~220/230/240V 50Hz/60Hz<br />

~220/230/240V 50Hz/60Hz<br />

0.067/0.076/0.085 0.082/0.093/0.104 0.097/0.110/0.123 0.127/0.144/0.161 0.156/0.177/0.198 0.201/0.288/0.255 0.246/0.279/0.312 0.127/0.144/0.161 0.156/0.177/0.198 0.201/0.228/0.255 0.246/0.279/0.312 0.060/0.068/0.076 0.119/0.135/0.151<br />

0.030/0.034/0.038 0.038/0.043/0.048 0.045/0.051/0.057 0.060/0.068/0.076 0.075/0.085/0.095 0.097/0.110/0.123 0.119/0.135/0.151 0.060/0.068/0.076 0.075/0.085/0.095 0.097/0.110/0.123 0.119/0.135/0.151 0.030/0.034/0.038 0.060/0.068/0.076<br />

0.054/0.061/0.067 0.066/0.074/0.082 0.078/0.088/0.097 0.102/0.115/0.127 0.126/0.141/0.156 0.162/0.182/0.201 0.198/0.222/0.246 0.102/0.115/0.127 0.126/0.141/0.156 0.162/0.182/0.201 0.198/0.222/0.246 0.048/0.054/0.060 0.096/0.108/0.119<br />

0.024/0.027/0.030<br />

0.31/0.34/0.36<br />

0.14/0.15/0.16<br />

0.25/0.27/0.28<br />

0.11/0.12/0.13<br />

0.030/0.034/0.038<br />

0.38/0.41/0.44<br />

0.18/0.19/0.20<br />

0.30/0.33/0.35<br />

0.14/0.15/0.16<br />

0.036/0.041/0.045<br />

0.45/0.48/0.52<br />

0.21/0.23/0.24<br />

0.36/0.39/0.41<br />

0.17/0.18/0.19<br />

0.048/0.054/0.060<br />

0.58/0.63/0.68<br />

0.28/0.30/0.32<br />

0.47/0.50/0.53<br />

0.22/0.24/0.25<br />

0.060/0.068/0.075<br />

0.71/0.77/0.83<br />

0.35/0.37/0.40<br />

0.58/0.62/0.65<br />

0.28/0.30/0.32<br />

Galvanizing<br />

Model P140 or smaller<br />

PURY-P200, 250, 300, 350YGM-A<br />

284<br />

648<br />

432<br />

For P200 type: ø15.88 Brazed<br />

For P250, P300, P350 type: ø19.05 Brazed<br />

For P200 type: ø19.05 Brazed<br />

For P250, P300 type: ø22.2 Brazed<br />

For P350 type: ø28.58 Brazed<br />

ø9.52 Flare<br />

(ø6.35 with attached reducer used, ø12.7 with optional joint pipe used)<br />

ø15.88 Flare<br />

(ø12.7 with attached reducer used, ø19.05 with optional joint pipe used)<br />

•Drain connection pipe (with flexible hose and insulation)<br />

•Reducer<br />

1098<br />

Galvanizing<br />

Model P140 or smaller<br />

PURY-P200~650YGM-A *2<br />

289<br />

1110<br />

520<br />

For P200 type: ø15.88 Brazed<br />

For P250, P300, P350 type: ø19.05 Brazed<br />

For P400 to P500 type: ø22.22 Brazed<br />

For P550 to P650 type: ø28.58 Brazed<br />

For P200 type: ø19.05 Brazed<br />

For P250, P300 type: ø22.2 Brazed<br />

For P350 to P650 type: ø28.58 Brazed<br />

ø9.52 Flare<br />

CMB-P108V~P1016V-GA<br />

284<br />

648<br />

432<br />

(ø6.35 with attached reducer used, ø12.7 with optional joint pipe used)<br />

ø15.88 Flare<br />

(ø12.7 with attached reducer used, ø19.05 with optional joint pipe used)<br />

For total capacity below P200 type: ø19.05 Brazed<br />

-<br />

For total capacity below P201 to P300 type: ø22.2 Brazed<br />

For total capacity below P301 to P350 type: ø28.58 Brazed<br />

For total capacity below P200 type: ø15.88 Brazed<br />

-<br />

For total capacity below P201 to P350 type: ø19.05 Brazed<br />

For total capacity below P300 type: ø9.52 Brazed<br />

-<br />

For total capacity below P301 to P350 type: ø12.7 Brazed<br />

VP-25<br />

VP-25<br />

24 27 29 34 39 47 54 44 49 57 64 22 32<br />

*1 Use optional joint pipe combining 2-branch when the total unit capacity exceeds P140.<br />

Use the reducer (standard accessory) when the indoor unit Model P50 or smaller is connected.<br />

CMB-P104,105,106,108,<br />

1010,1013V-G<br />

Drain piping<br />

VP-25 connection<br />

181<br />

64<br />

130<br />

Connnection pipe of outdoor unit<br />

(High pressure)<br />

200: ø15.88 (with accessory)<br />

250, 300, 350: ø19.05<br />

103<br />

64<br />

23<br />

248<br />

Connection pipe of outdoor unit (Low pressure)<br />

200: ø219.05 (with accessory)<br />

250, 300: ø22.2<br />

350: ø28.58 (with accessory)<br />

284<br />

255<br />

128<br />

X<br />

58<br />

27<br />

Y<br />

200<br />

70<br />

<br />

• Refrigerant conn. pipe (Large, Small).....2pc<br />

• Refrigerant conn. pipe............................1pc<br />

• Reducer (Large, Small)..................Quantity for all connection<br />

• Drain hose (VP-25 connection)..........................................1pc<br />

• Pipe cover for drain hose...................................................1pc<br />

• Hose band..........................................................................1pc<br />

• Tie band.............................................................................1pc<br />

Band (accessory)<br />

Drain hose (Accessory)<br />

ø31<br />

Detail of X section<br />

76 60XC=D<br />

60<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16<br />

A<br />

B (Lifting bolt pitch)<br />

30<br />

12<br />

Control box<br />

14<br />

Detail of Y section<br />

0.078/0.088/0.097<br />

0.92/1.00/1.07<br />

0.45/0.48/0.52<br />

0.74/0.80/0.84<br />

0.36/0.39/0.41<br />

<strong>External</strong> <strong>Dimensions</strong><br />

Note 1. Suspesion bolt (ø10), washer (M10) and<br />

nut (M10) prepare in the field.<br />

2. Take notice of service space as follows;<br />

(Please give attention not to occupy service<br />

space by letting ducts and pipes through)<br />

In the following, Access door in service space<br />

is a door for service. There fore, another door<br />

is necessary to unload products.<br />

CMB-P104V-G<br />

CMB-P105V-G<br />

CMB-P106V-G<br />

CMB-P108V-G<br />

CMB-P1010V-G<br />

CMB-P1013V-G<br />

CMB-P1016V-G<br />

70<br />

298 (Lifting bolt pitch)<br />

362<br />

Connection pipe of<br />

indoor unit (Liquid)<br />

ø9.52 (Flare)<br />

(200)<br />

Connection pipe of<br />

indoor unit (Gas)<br />

ø15.88 (Flare)<br />

Service<br />

space<br />

A<br />

648<br />

1098<br />

B<br />

702<br />

1152<br />

Access door<br />

450<br />

C<br />

3<br />

4<br />

5<br />

7<br />

9<br />

12<br />

15<br />

200<br />

180<br />

240<br />

300<br />

420<br />

540<br />

720<br />

900<br />

250<br />

D<br />

(700)<br />

0.096/0.108/0.119<br />

1.12/1.22/1.30<br />

0.55/0.59/0.63<br />

0.90/0.97/1.03<br />

0.44/0.47/0.50<br />

0.048/0.054/0.060<br />

0.58/0.63/0.68<br />

0.28/0.30/0.32<br />

0.47/0.50/0.53<br />

0.22/0.24/0.25<br />

0.060/0.068/0.075<br />

0.71/0.77/0.83<br />

0.35/0.37/0.40<br />

0.58/0.62/0.65<br />

0.28/0.30/0.32<br />

0.078/0.088/0.097<br />

0.92/1.00/1.07<br />

0.45/0.48/0.52<br />

0.74/0.80/0.84<br />

0.36/0.39/0.41<br />

0.096/0.108/0.119<br />

1.12/1.22/1.30<br />

0.55/0.59/0.63<br />

0.90/0.97/1.03<br />

0.44/0.47/0.50<br />

0.024/0.027/0.030<br />

0.28/0.30/0.32<br />

0.14/0.15/0.16<br />

0.22/0.24/0.25<br />

0.11/0.12/0.13<br />

0.048/0.054/0.060<br />

0.55/0.59/0.63<br />

0.28/0.30/0.32<br />

0.44/0.47/0.50<br />

0.22/0.24/0.25<br />

•Drain connection pipe (with flexible hose and insulation)<br />

•Reducer<br />

*2 Additional pipework is needed to connect with P300 type or lower outdoor unit.<br />

ø31<br />

Connnection pipe of<br />

MASTER BC CONTROLLER (High pressure)<br />

Total capacity of indoor unit.<br />

For 200 or less: ø15.88<br />

(with accessory)<br />

For 201 or over: ø19.05<br />

Drain piping<br />

VP-25 connection<br />

CMB-P104,108V-GB<br />

Band (accessory)<br />

Drain hose (Accessory)<br />

181<br />

Connnection pipe of<br />

MASTER BC CONTROLLER<br />

(Low pressure)<br />

Total capacity of indoor unit.<br />

For 200 or less: ø19.05<br />

(with accessory)<br />

From 201 to 300: ø22.2<br />

For 301 or over: ø28.58<br />

(with accessory)<br />

Detail of X section<br />

64<br />

130<br />

<br />

• Reducer.....Quantity for all connections<br />

• Drain hose (VP-25 connection).......1pc<br />

• Pipe cover for drain hose.................1pc<br />

• Hose band.......................................1pc<br />

• Tie band...........................................2pc<br />

64<br />

45<br />

103<br />

169<br />

23<br />

284<br />

255<br />

248<br />

30<br />

128<br />

12<br />

X<br />

58<br />

27<br />

Y<br />

14<br />

Detail of Y section<br />

Connnection pipe of<br />

MASTER BC CONTROLLER (Liquid)<br />

Total capacity of indoor unit.<br />

For 300 or less: ø9.52<br />

For 301 or over: ø12.7 (with accessory)<br />

70<br />

76<br />

60<br />

Control box<br />

648<br />

702 (Lifting bolt pitch)<br />

60XA=B<br />

1 2 3 4 5 6 7 8<br />

A B<br />

CMB-P104V-GB 3 180<br />

CMB-P108V-GB 7 420<br />

298 (Lifting bolt pitch)<br />

70<br />

362<br />

(200)<br />

Connection pipe of<br />

indoor unit (Liquid)<br />

ø9.52 (Flare)<br />

Unit : mm<br />

Note 1. Suspesion bolt (ø10), washer (M10)<br />

and nut (M10) prepare in the field.<br />

2. Take notice of service space as follows;<br />

(Please give attention not to occupy service<br />

space by letting ducts and pipes through)<br />

In the following, Access door in service<br />

space is a door for service. There fore, another<br />

door is necessary to unload products.<br />

3. Can't use singleness.<br />

(MASTER BC CONTROLLER is necessary.)<br />

Access door<br />

450<br />

Service space<br />

200<br />

(700)<br />

250<br />

CMB-P108,1010,1013,1016V-GA<br />

Drain piping<br />

VP-25 connection<br />

333<br />

64<br />

64 103<br />

268<br />

Connnection pipe of<br />

outdoor unit (High pressure)<br />

For P200 type: ø15.88 Brazed<br />

For P250, P300 type: ø19.05 Brazed<br />

For P350 type: ø22.22 Brazed<br />

For P400 to P650 type: ø28.58 Brazed<br />

Y<br />

X<br />

Band (accessory)<br />

Drain hose (Accessory)<br />

1110<br />

130 23<br />

ø31<br />

Detail of X section<br />

Control box<br />

30<br />

12<br />

450 70<br />

14<br />

Detail of Y section<br />

388 (Lifting bolt pitch)<br />

268<br />

210<br />

103<br />

66<br />

128<br />

74<br />

200<br />

Connection pipe of<br />

SUB BC CONTROLLER (High pressure)<br />

Total capacity of indoor unit<br />

For 200 or less: ø15.88 (with accessory)<br />

For 201 or over: ø19.05<br />

Connection pipe of<br />

SUB BC CONTROLLER (Liquid)<br />

Total capacity of indoor unit<br />

For 300 or less: ø9.52<br />

For 301 or over: ø12.7 (with accessory)<br />

Connection pipe of<br />

SUB BC CONTROLLER (Low pressure)<br />

Total capacity of indoor unit<br />

For 200 or less: ø19.05 (with accessory)<br />

From 201 to 300: ø22.2<br />

For 301 or over: ø28.58 (with accessory)<br />

Connection pipe of<br />

indoor unit (Gas)<br />

ø15.88 (Flare)<br />

<br />

• Refrigerant conn. pipe...............1pc<br />

• Refrigerant conn. pipe..............1pc<br />

• Reducer (Large, Small).....Quantity for all connection<br />

• Drain hose (VP-25 connection)............................1pc<br />

• Hose band............................................................1pc<br />

• Tie band...............................................................1pc<br />

Note 1. Suspesion bolt (ø10), washer (M10) and nut (M10) prepare<br />

in the field.<br />

2. Take notice of service space as follows:<br />

(Please give attention not to occupy service space by letting<br />

ducts and pipes through)<br />

In the following, Access door in service space is a door for<br />

service. There fore, another door is necessary to unload products.<br />

3. Please take space to connect SUB BC CONTROLLER.<br />

25<br />

Connection pipe of outdoor unit<br />

(Low pressure)<br />

For P200 type: ø19.05 Brazed<br />

For P250, P300 type: ø22.2 Brazed<br />

For P350 type: ø28.58 Brazed<br />

For P400 to P650 type: ø28.58 Brazed<br />

289<br />

260<br />

128<br />

74<br />

27<br />

90 76<br />

60<br />

1 2<br />

70<br />

3<br />

4<br />

5<br />

1164 (Lifting bolt pitch)<br />

60XA=B<br />

6 7 8 9 10 11 12 13 14 15 16<br />

Connection pipe of indoor unit (Liquid)<br />

ø9.52 (Flare)<br />

70<br />

Connection pipe of<br />

indoor unit (Gas)<br />

Service<br />

space<br />

Access door<br />

450<br />

200<br />

200<br />

250<br />

700<br />

CMB-P108V-GA<br />

CMB-P1010V-GA<br />

CMB-P1013V-GA<br />

CMB-P1016V-GA<br />

A<br />

7<br />

9<br />

12<br />

15<br />

B<br />

420<br />

540<br />

720<br />

900<br />

200<br />

ø15.88 (Flare)<br />

200


Wide selection of indoor units<br />

Ceiling cassette (4way air flow)<br />

PLFY-P VCM-E<br />

PLFY-P VAM-E<br />

Ceiling suspended<br />

Model<br />

Capacity<br />

P20 P25 P32 P40 P50 P63 P80 P100 P125<br />

2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 9.0kW 11.2kW 14.0kW<br />

PCFY-P VGM-E<br />

Model P40 P63 P100 P125<br />

Capacity 4.5kW 7.1kW 11.2kW 14.0kW<br />

Ceiling cassette (2way air flow)<br />

PLFY-P VLMD-E<br />

Wall mounted<br />

PKFY-P VAM-E<br />

PKFY-P VGM-E<br />

PKFY-P VFM-E<br />

Model<br />

P20 P25 P32 P40 P50 P63 P71 P80 P100 P125<br />

Model<br />

P20 P25 P32<br />

P40<br />

P50<br />

P63<br />

P100<br />

Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 8.0kW 9.0kW 11.2kW 14.0kW<br />

Capacity<br />

2.2kW 2.8kW 3.6kW<br />

4.5kW<br />

5.6kW<br />

7.1kW<br />

11.2kW<br />

Ceiling cassette (1way air flow)<br />

Floor standing<br />

New<br />

PFFY-P VLEM-E<br />

PFFY-P VKM-E<br />

PMFY-P VBM-E<br />

PFFY-P VLRM-E<br />

Model<br />

P20 P25 P32 P40<br />

Model<br />

P20 P25 P32 P40<br />

P50<br />

P63<br />

Capacity<br />

2.2kW 2.8kW 3.6kW 4.5kW<br />

Capacity<br />

2.2kW 2.8kW 3.6kW 4.5kW<br />

5.6kW<br />

7.1kW<br />

Ceiling concealed<br />

New<br />

Fresh Air Intake<br />

PEFY-P VMH-E-F<br />

PEFY-P VMR-E-L/R<br />

PEFY-P VMH-E<br />

PEFY-P VMM-E<br />

PEFY-P VML-E<br />

New<br />

PEFY-P VMS-E<br />

Model P20 P25 P32 P40 P50 P63 P71 P80 P100 P125 P140 P200<br />

P250<br />

Model<br />

P80<br />

P140<br />

P200<br />

P250<br />

Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 8.0kW 9.0kW 11.2kW 14.0kW 16.0kW 22.4kW 28.0kW<br />

Capacity<br />

9.0kW<br />

16.0kW<br />

22.4kW<br />

28.0kW<br />

26


INDOOR UNIT<br />

Ceiling cassette type<br />

4-way airflow<br />

PLFY-P VCM-E/VAM-E<br />

PLFY-P VCM-E<br />

PLFY-P VAM-E<br />

VCM<br />

VAM<br />

The new compact cassette VCM is suitable for 2x2 ceiling!<br />

compact body to match with<br />

2feets (600mm) x 2feets (600mm)<br />

ceiling design (VCM)<br />

570mm<br />

570mm<br />

Easy Installation<br />

Superb Features<br />

Only two panel sizes–perfectly suited to<br />

various installation configurations<br />

Only two panel sizes are available,650mm(25-<br />

5/8in.) for the compact VCM and 950mm(37-<br />

7/16in.) for the power cassette VAM. The VCM is<br />

lightweight min.15kg(34lbs)(P20/P25)<br />

PLFY-VCM Type<br />

PLFY-VAM Type<br />

Drain water pipe lifted to 850mm(33- 1 /2in.)<br />

(power cassette VAM)<br />

The drain piping of the VAM can be<br />

positioned anywhere up to 850mm(33- 1 /2in.)<br />

from the ceiling's surface, allowing greater<br />

freedom with long cross-piping and more<br />

versatility with piping layouts<br />

(VCM: 500mm(19- 11 /16in.)).<br />

850mm<br />

(33- 1 /2in.)<br />

First in the industry to offer 72 airflow<br />

patterns (power cassette VAM)<br />

The 72 different airflow patterns provide the<br />

best solution for varying room layouts and<br />

air-conditioning requirements. For extra<br />

versatility, you can also select from two-,<br />

three- or four-way outlets. What's more, the<br />

addition of separate motors to the individual<br />

vanes enables manual control that-together<br />

with remote control vane settings-make<br />

possible highly customized and flexible<br />

airflow patterns.<br />

650mm<br />

(25- 5 /8in.)<br />

950mm<br />

(37- 7 /16in.)<br />

4-, 3-, or 2-<br />

way outlet<br />

selection<br />

Unit height of only 208mm* 1 great for<br />

low-ceiling space situations<br />

The new compact cassette VCM has a unit<br />

height of only 208mm *1 , to realize neat<br />

installation in low-ceiling situations with very<br />

limited space.<br />

*:8- 1 /4in<br />

(compact cassette VCM)<br />

Only<br />

208mm*!<br />

Handy corner-pocket design simplifies maintenance<br />

and installation (power cassette VAM)<br />

By using the handy corner pockets equipped<br />

on four corners of the grille, maintenance<br />

work such as drain pan cleaning and height<br />

adjustment can be accomplished without<br />

removing the grille. It is also easier to adjust<br />

the ceiling height of the indoor unit during<br />

installation.<br />

Fixed airflow<br />

direction per<br />

vane<br />

Motor<br />

for the<br />

vane<br />

72 airflow patterns<br />

*Optional air outlet shutter plate is<br />

necessary for two-or three-way airflow<br />

settings. The noise level may increase<br />

during two-or three-way airflow setup.<br />

*For VCM model, 2 or 3 way airflow is<br />

not available.<br />

27


INDOOR UNIT<br />

Ceiling cassette type<br />

4-way airflow<br />

PLFY-P VCM-E<br />

PLFY-P VAM-E<br />

Superb Features<br />

Outstanding <strong>Specifications</strong><br />

For Retail Outlets<br />

(Power cassette VAM)<br />

These units are ideal for maintaining constant<br />

temperatures in environments that have<br />

equipment such as refrigerate showcases.<br />

Individual vane angle adjustment enables<br />

precise airflow control to specific areas of the<br />

store to reduce unnecessary air conditioning<br />

of areas such as refrigerated showcases.<br />

Remote control setting for two directions<br />

Fixed vane for two directions<br />

Smudge-free airflow prevents soiling of the<br />

ceiling surface (power cassette VAM )<br />

Mitsubishi Electric has developed a new airflow<br />

control mechanism where a projection inside the<br />

air passage distributes air evenly over the vane's<br />

upper and lower surface while two additional<br />

projections at the air outlet's exit adjust the angle<br />

of the airflow. This helps to prevent indoor air<br />

from rising, stopping it from hitting the surface<br />

of the ceiling to reduce the likelihood of soiling<br />

from smudging and condensation.<br />

Wide-flow air outlet delivers<br />

a comforting breeze (VAM)<br />

The airflow of the VAM power cassette is<br />

powerful enough to warm atrium-type<br />

ceilings up to 4.2 meter(13- 13 /16Ft) in height.<br />

4-way high ceiling 2 (VAM)<br />

4.2m<br />

(13- 13 /16Ft)<br />

4-way standard (VAM)<br />

3.2m<br />

(10- 1 /2Ft)<br />

Fixed<br />

Fixed<br />

Smudging and the new<br />

airflow control mechanism<br />

3.6m<br />

(11- 13 /16Ft)<br />

Outside<br />

Inside<br />

3-way standard (VAM)<br />

Fixed<br />

Refrigerated<br />

showcase not<br />

affected by air<br />

conditioning<br />

Fixed<br />

Top or bottom<br />

airflow setting via<br />

remote controller<br />

Compatible with both round and square<br />

ducts (power cassette VAM)<br />

For easy connection to branch ducts,<br />

knockout holes are designed to fit both round<br />

and square ducts. Matching the shape of the<br />

duct fringe provides more flexibility during<br />

installation.<br />

Connecting to round ducts<br />

1<br />

2 3<br />

Grille<br />

Wider airflow setting<br />

reduces annoying drafts<br />

30° horizontal<br />

position<br />

70° vertical<br />

position<br />

3<br />

1<br />

A projection is created on the outside, where the airflow is<br />

fastest. This diverts the airflow and distributes it evenly<br />

over the upper and lower surfaces of the Vane.<br />

The air outlet exit also has projections to prevent air from rising<br />

within the room and stopping it from hitting the ceiling.<br />

30°<br />

70°<br />

2<br />

Vane<br />

Smudging:<br />

When cooled air is<br />

expelled horizontally, it<br />

tends to cling to the<br />

surface of the ceiling. This<br />

cools the surface down<br />

and causes condensation,<br />

which attracts dust from<br />

the room's interior to soil<br />

the ceiling's surface.<br />

Bristle-free vane can be cleaned simply<br />

(power cassette VAM )<br />

The unique suction mechanism prevents indoor<br />

air from rising to eliminate condensation on the<br />

vane and make bristles unnecessary.<br />

<strong>Specifications</strong> according to ceiling height and number of vents<br />

4-way<br />

3-way<br />

2-way<br />

During operation<br />

Power Cassette VAM<br />

Standard High ceiling 1 High ceiling 2<br />

3.2<br />

3.6<br />

4.0<br />

3.6<br />

4.0<br />

4.2<br />

4.2<br />

4.2<br />

---<br />

*VCM:2.7m(standard/4way only)<br />

Functional and appealing vane shutter<br />

(power cassette VAM)<br />

When the air conditioner is not operating, the<br />

vane shutter closes automatically to conceal<br />

the air outlet and create an aesthetically<br />

appealing flat surface.*<br />

*This feature will not activate when the vane is set at<br />

fixed position.<br />

When turned off<br />

150mm(5- 15 /16in.) diameter cutout<br />

Connecting to rectangular ducts<br />

Direct intake of fresh exterior air<br />

(power cassette VAM &compact cassette VCM)<br />

Indoor air quality is significantly enhanced by<br />

the direct intake of fresh exterior air. An<br />

optional multi-function casement is also<br />

available (only for VAM) for the intake of a<br />

larger volume of air.<br />

350mm(13- 13 /16in.)~100mm(3- 15 /16in.) cutout<br />

28


INDOOR UNIT<br />

Ceiling cassette type<br />

2-way airflow<br />

(drain-up mechanism is built in)<br />

PLFY-P VLMD-E<br />

PLFY-P VLMD-E<br />

Slim body of 290 mm* height. (*11- 7 /16in.)<br />

Slim body - only 290mm height<br />

The slimline body is highly suitable for installation in narrow ceiling<br />

spaces and for replacing obsolete air-conditioning equipment in older<br />

buildings. The main unit is only 290mm* height.<br />

290mm*<br />

(*: 11- 7 /16in.)<br />

Equipped with drain water lift-up<br />

mechanism as standard<br />

Terminal block on outside of main unit<br />

makes wiring easier<br />

The drain can be positioned anywhere up to 600mm* from the<br />

ceiling's surface, providing greater freedom with long cross-piping<br />

and allowing more versatility with piping layouts.(*: 23- 5 /8in.)<br />

Main unit height - 290mm(11- 7 /16in.)<br />

Drain height<br />

max. 593mm(23- 3 /8in.)<br />

Newly designed decorative panel with air flow<br />

switching and swing functions as a standard feature<br />

Ceiling surface<br />

593<br />

(unit: mm)<br />

Compact unit and low noise level attained!<br />

Fresh air directly taken in<br />

Fresh air can be taken in to the main unit directly (optional accessories<br />

needed.<br />

29


INDOOR UNIT<br />

Ceiling cassette type<br />

1-way airflow<br />

PMFY-P VBM-E<br />

PMFY-P VBM-E<br />

Compact and lightweight body perfect for<br />

limited ceiling space applications.<br />

Compact size for smooth<br />

installation and maintenance<br />

Unit body size has been standardized for all<br />

models at 854mm for easier installation. Body<br />

weight is also only 14kg for the main unit and<br />

3kg for the panel, making this unit one of the<br />

lightest in the industry.<br />

Quiet operation<br />

Newly developed airflow control technology<br />

reduces noise level to only 27dB (P20VBM)<br />

for industry-leading quiet operation.<br />

Drain lift-up mechanism<br />

The drain can be positioned anywhere up to 600mm* from the ceiling's surface.(*: 23- 5 /8in.)<br />

max.<br />

600*<br />

230<br />

(9- 11 /16)<br />

PMFY-VBM<br />

max.<br />

402<br />

(15- 7 /8)<br />

198<br />

(7- 13 /16)<br />

unit: mm(in.)<br />

30


INDOOR UNIT<br />

Ceiling concealed<br />

type<br />

PEFY-P VMR-E-L/R<br />

New<br />

PEFY-P VMR-E-L/R<br />

Problem solver for residential hotels, museums, libraries,<br />

or hospitals where low noise is especially a must!<br />

Inlet<br />

Card Key<br />

Switch<br />

Noise measurement point<br />

Noise measurement point<br />

*According to the data measured in Mitsubishi Electric laboratory<br />

Operable by card key switch<br />

Ultra low noise<br />

Prepared a contact for a card key. It’s possible<br />

to operate / stop by taking a card key in and<br />

out.<br />

Enables to install for symmetric<br />

design room<br />

Both of Left piping / Right piping, control<br />

box, are available.<br />

It's selectable for layout of each room.<br />

Plus easy maintenance from the access door<br />

in the prefabricated bath.<br />

*Seen from an anterior view, the pipe and<br />

control box are on the right side of –R type.<br />

Realizing the low level noise that is NC21 around a bed and N22 around a desk when the high<br />

notch.<br />

It contributes to create a quiet indoor environment.<br />

*Outlet is elbow-constructed using a glass wool duct.<br />

The noise level is changed by the room size or the setting condition of the unit.<br />

Energy-saving by prevention of forgetting the switch off<br />

Compact & Simple operation remote controller is available.<br />

*This remote controller can operate only start / stop, Indoor temperature control and wind speed<br />

control. Centralized remote controller must be used together.<br />

Enables a prevention to forget the switch in a vacant room off by the centralized remote<br />

controller like G-50.<br />

31


INDOOR UNIT<br />

Ceiling concealed<br />

type<br />

PEFY-P VMS-E<br />

New<br />

PEFY-P VMS-E<br />

Increased design flexibility for the places where low noise<br />

operation is especially needed from an ultra thin body.<br />

Changeable static pressure<br />

(4 stage 5-15-35-50Pa)<br />

Ultra low height unit with 200mm high<br />

Can be installed easily in tight spaces, such as ceiling cavities or drop-ceilings.<br />

Changeable air flow rate<br />

(3 stage low-middle-high)<br />

Drain lift-up pump is attached<br />

as standard.<br />

Filter is attached as standard.<br />

More than 20mm<br />

More than 20mm<br />

Ceiling surface Access door<br />

Make the access door at the appointed position properly<br />

for service maintenance.<br />

unit: mm<br />

Reduced noise thanks to the use of newly designed centrifugal fan and coil<br />

Noise level table (Standard static pressure)<br />

Noise<br />

Level<br />

Capacity<br />

High<br />

Fan<br />

Speed<br />

Mid<br />

Low<br />

P20<br />

27<br />

25<br />

22<br />

P25<br />

27<br />

25<br />

22<br />

dB(A)<br />

P32<br />

30<br />

28<br />

25<br />

32


INDOOR UNIT<br />

Ceiling concealed<br />

type<br />

PEFY-P VML-E<br />

PEFY-P VML-E<br />

Increased design flexibility for hotel and residential use.<br />

Low static pressure (5Pa) meets<br />

an application requiring direct air flow<br />

Changeable air flow rate<br />

(3 stage low-middle-high)<br />

Low height unit with 225mm* high<br />

Can be installed easily in tight spaces, such as ceiling cavities or drop-ceilings.<br />

Notes: Drain lift-up pump not applicable.<br />

Service space:500(19- 11 /16) or more Hole pitch 100(3- 15 /16) or more<br />

*: 8- 7 /8in.<br />

Flexible installation by rear<br />

or bottom return air inlet.<br />

245(9- 11 /16)+Drain<br />

covering<br />

configuration<br />

height<br />

225<br />

(8- 7 /8)<br />

20( 13 /16) or more<br />

30(1- 3 /16)<br />

Filter is attached as standard.<br />

Access door<br />

20/25/32 Model<br />

unit: mm(in.)<br />

Reduced noise thanks to the use of<br />

newly designed centrifugal fan<br />

Noise level table (Standard static pressure 220V)<br />

Noise<br />

Level<br />

Capacity<br />

High<br />

Fan<br />

Speed<br />

Mid<br />

Low<br />

P20<br />

36<br />

29<br />

25<br />

P25<br />

36<br />

29<br />

25<br />

dB(A)<br />

P32<br />

40<br />

29<br />

25<br />

Note: In the case of bottom inlet, the operating noise is<br />

louder than in the case of rear inlet.<br />

Drainage lines may be connected<br />

on either the right or left side.<br />

Perfect for use in hotels and other places<br />

where line placement is a problem.<br />

33


INDOOR UNIT<br />

Ceiling concealed<br />

type<br />

PEFY-P VMM-E<br />

PEFY-P VMM-E<br />

Achieving creative air conditioning design<br />

through a rich array of system materials.<br />

Flexible installation for a variety of layouts<br />

Long room<br />

L-shaped rooms<br />

Room with fixed<br />

ceiling fixtures<br />

Air outlet side compatible<br />

with a variety of ducts (optional)<br />

Multiple installation patterns for assorted applications and locations<br />

Bottom intake (directly attached to panel)<br />

Bottom intake (using canvas duct)<br />

Adjustable setting of external static pressure to meet<br />

system configuration and installation conditions<br />

Maintenance panel<br />

with air intake<br />

Static pressure settings can be increased to<br />

adjust to all kinds of ducts as well as<br />

functional upgrade option (high performance<br />

filter etc). An increase from the standard 50Pa<br />

to 130* Pa is possible to cope with various<br />

layout configurations.<br />

*For P100~P125.<br />

All-duct system<br />

Square duct flange<br />

Ceiling chamber system (2)<br />

Maintenance panel<br />

A bottom intake can<br />

also be used<br />

Ceiling chamber system (1)<br />

Hanging ceiling installation<br />

Maintenance panel<br />

A rear intake can<br />

also be used<br />

Square duct flange<br />

Slim 295mm main unit with optional drain up<br />

mechanism ensures up to 600 mm of lift<br />

System ceiling<br />

Max.<br />

600<br />

Max.<br />

416<br />

184<br />

295<br />

34


INDOOR UNIT<br />

Ceiling concealed<br />

type<br />

PEFY-P VMH-E<br />

PEFY-P VMH-E<br />

Increased design flexibility from sufficient external static pressure<br />

allow authentic duct air- conditioning with an elegant interior layout.<br />

<strong>External</strong><br />

static<br />

pressure<br />

(Pa)<br />

Maximum external static pressure 200Pa<br />

The additional external static pressure capacity provides flexibility for<br />

duct extension, branching and air outlet configuration.<br />

220V<br />

230/240V<br />

380V<br />

400/415V<br />

P40 P50 P63 P71 P80 P100 P125 P140 P200 P250<br />

50/100/200<br />

100/150/200<br />

110/220<br />

130/260<br />

Reduced noise thanks to the use of<br />

newly designed centrifugal fan<br />

One-side maintenance<br />

All maintenance to the unit, including<br />

fan inspection and fan motor removal,<br />

can be conducted from the inspection<br />

opening on one side.<br />

Drain up mechanism (option) ensures<br />

up to 550mm* of lift<br />

*: 21- 11 /16in.<br />

The introduction of an upper drain mechanism allows the drain<br />

connection to be raised as high as 550mm*, allowing more freedom in<br />

piping layout design and reducing horizontal piping requirements.<br />

Noise level table (Standard static pressure 220V)<br />

dB(A)<br />

Noise<br />

Level<br />

Capacity<br />

Fan<br />

Speed<br />

High<br />

Low<br />

P40<br />

34<br />

27<br />

P50<br />

34<br />

27<br />

P63<br />

38<br />

32<br />

P71<br />

39<br />

32<br />

P80<br />

41<br />

35<br />

P100<br />

42<br />

34<br />

P125<br />

42<br />

34<br />

P140<br />

42<br />

34<br />

MAX.<br />

550mm<br />

(21- 11 /16in.)<br />

222mm<br />

(8- 3 /4in.)<br />

328mm<br />

(12- 15 /16in.)<br />

35


INDOOR UNIT<br />

Ceiling suspended<br />

type<br />

PCFY-P VGM-E<br />

PCFY-P VGM-E<br />

Designed for ultra-quiet operation and easy maintenance,<br />

provides exceptionally comfortable air-conditioning.<br />

Extra slim, extra stylish<br />

Seek and slim with stylishly curved lines, the PCFY series blends right<br />

into any interior. It also features a single air outlet which allows the<br />

auto vane to act as a shutter when the unit is turned off.<br />

Keeps airflow at optimum level<br />

according to ceiling height<br />

The most suitable airflow can be selected for ceilings up to 3.5m high,<br />

enhancing air-conditioning efficiency and comfort.<br />

Standard<br />

High ceiling<br />

Ceiling height 2.7m(8- 7 /8Ft) 3.5m(11- 1 /2Ft)<br />

Greatly simplified installation<br />

Auto vane distributes air evenly<br />

The new direct suspension system eliminates the task of removing the<br />

attachment fixture from the main unit, greatly shortening installation<br />

time.<br />

The auto vane swings up and down automatically to distribute air more<br />

evenly to every corner of the room.<br />

Direct suspension with attachment fixture attached<br />

1. Leave attachment fixture<br />

attached to main unit.<br />

2. Suspend the attachment<br />

fixture from the suspension bolts.<br />

3. Simply tighten the nuts<br />

to secure the unit.<br />

Ceiling surface<br />

Suspension<br />

bolts<br />

Attachment<br />

fixture<br />

Auto vane<br />

Air outlet<br />

Swing<br />

*A one-touch suspension is also available: simply suspend<br />

the main unit from the attachment fitting after securing<br />

the latter to the ceiling.<br />

Drain piping can be connected in one of two<br />

directions, to the left or the right of the unit<br />

36


INDOOR UNIT<br />

Wall mounted<br />

type<br />

PKFY-P VAM-E<br />

PKFY-P VGM-E<br />

PKFY-P VFM-E<br />

PKFY-P VAM<br />

PKFY-P VFM<br />

PKFY-P VGM<br />

PKFY-P VAM-E<br />

PKFY-P VGM-E<br />

PKFY-P VFM-E<br />

Elegant Design and Compact <strong>Dimensions</strong> Ideal for Offices,<br />

Stores and Residential Uses.<br />

Capacity range<br />

Capacity P20 P25 P32 P40 P50<br />

VAM<br />

VGM<br />

VFM<br />

P63 P100<br />

Compact design with 990mm* width<br />

(PKFY-P VGM)<br />

Width reduced by 20% to a compact<br />

990mm*. *: 39in.<br />

Extra compactness has been achieved thanks<br />

to a 20%(260mm(10- 1 /4in.))<br />

reduction in which compared with previous<br />

models.<br />

Compact 295mm(11- 5 /8in.) high body fits<br />

snugly in even limited spaces (PKFY-P VAM)<br />

In room air conditioning style, the grille<br />

opens out allowing the filter to be removed.<br />

The filter and open grille can therefore be<br />

thoroughly and easily cleaned.<br />

Quiet operation (PKFY-P VGM)<br />

Among the quietest in the industry<br />

Airflow passage configuration that assures quiet operations<br />

1. The unit incorporates a randon pitch cycling fan. By changing fan<br />

intervals reduction in airflow. Optimal design of the airflow passage<br />

gives a shorted fan diameter and allows a highly compact installation.<br />

2. Thanks to a highly practical casing configuration, airflow<br />

generated by the fan is distributed uniformly.<br />

3. Due to careful positioning of the vertical vane axis, air is blown<br />

evenly from the fan. This prevents mixing with secondary air,<br />

and also suppresses condensation.<br />

Front grille opens out - easy filter cleaning (PKFY-P VGM)<br />

3<br />

Front grille<br />

opens out<br />

1<br />

2<br />

Lightweight 8.5kg(20lbs) unit easy to<br />

transport and install (PKFY-P VAM)<br />

Front power supply box for easier<br />

wiring even after installation<br />

5-way piping provides more flexibility<br />

in selecting installation sites<br />

37<br />

Auto-flap shutter enhances<br />

good looks<br />

The front power supply box allows electrical<br />

wiring work to be done after the indoor unit<br />

has been installed. For easier installation, all<br />

the screws required for securing the indoor<br />

unit to the wall are accessible from the front<br />

of the unit.<br />

All piping including drainage can be<br />

connected from the rear, right, base, and left<br />

of the unit, providing much greater flexibility<br />

out piping and selecting installation site.


INDOOR UNIT<br />

Floor standing<br />

type<br />

PFFY-P VKM-E<br />

New<br />

PFFY-P VKM-E<br />

For living rooms, bed rooms, or offices where a sophisticated<br />

design is required. The latest Mitsubishi innovation – floor-standing<br />

air-conditioner sophisticated in design, rich in function.<br />

Quiet Operation<br />

Mitsubishi Electric air conditioners have<br />

always been some of the quietest model<br />

available in the market. Our new floorstanding<br />

models are no exception.<br />

It can create a silent and comfortable space<br />

where the occupants would not even<br />

recognize the existence<br />

of air conditioner<br />

operation.<br />

✻2.5kw class<br />

ONLY<br />

27dB<br />

Noise level<br />

Subway car<br />

interior<br />

Quiet passenger<br />

car interior<br />

(40km/h)<br />

Library interior<br />

Human<br />

Sound of hearing limits<br />

rustling leaves (Extremely quiet)<br />

80dB<br />

60dB<br />

40dB<br />

%@*<br />

JDA<br />

GKEAJAIJ<br />

10dB<br />

Sophisticated Design<br />

From Mitsubishi<br />

Electric, an<br />

innovative new floorstanding<br />

airconditioner.<br />

Our<br />

pleasing mix of<br />

streamlined form and<br />

diversified function.<br />

Engineered to keep<br />

room walls free,<br />

furnish comfy cooling<br />

in summer, toasty heating in winter.<br />

Deluxe look in<br />

“Glossy Pure White” color<br />

Sleek louvers look just like<br />

flat panels<br />

Smart upper/lower air outlets<br />

close when switched off<br />

The “Glossy Pure White” colour ensures a deluxe look, the perfect<br />

match for any room. Both upper and lower air outlets remain closed<br />

when switched OFF, in a smart and striking image.<br />

A superb new air-conditioner from Mitsubishi, providing a handsome<br />

fit for your own distinctive interior.<br />

Optimum Air Distribution<br />

Comfy room temperatures are realized by the optimum, powerful and<br />

efficient air distribution through upper and lower air outlets.<br />

The upper vane angle is remote controllable, with 5 air flow direction<br />

levels (+Swing and Auto modes) and 4 wind power levels (+Auto<br />

mode).<br />

By setting the vane angle almost vertical, annoying direct wind can be<br />

avoided for your better comfort.<br />

The unit body is slim and<br />

trim, the essence in<br />

compact. An ideal size for<br />

living rooms, bedrooms,<br />

attics and more.<br />

The removable and<br />

washable front panel makes<br />

cleaning a snap.<br />

Slim but Mighty<br />

700mm<br />

Easy and regular cleaning allows your air-conditioner stay beautiful<br />

while keeping its energy-efficient operation always possible.<br />

600mm<br />

200<br />

mm<br />

The air from both upper and lower air<br />

outlets is optimally controlled and distributed<br />

evenly to every corner of the room.<br />

In heating mode, the warm air is smartly<br />

controlled to stay at the floor level: Your<br />

feet do not feel chilled any more!<br />

14 16 18 20 22 24 26 ˚C<br />

38


INDOOR UNIT<br />

Floor standing<br />

type<br />

PFFY-P VLEM-E<br />

PFFY-P VLEM-E<br />

Floor mounted lowboy type<br />

effective in perimeter zone.<br />

Standardized design with mild lines.<br />

Supports various types of spaces from<br />

office buildings and shop buildings to<br />

hospitals.<br />

Water vapor permeable film humidifier<br />

can be installed.<br />

Remote control can be installed onto<br />

the main unit.<br />

Compact unit for easy air<br />

conditioning in perimeter zone.<br />

The compact body of 220mm(7- 7 /8in.) in<br />

depth can be easily installed in the perimeter<br />

zone for effective air conditioning in the<br />

perimeter zone.<br />

Electronics dry function<br />

dehumidify refreshingly.<br />

Optimum dehumidification depending on<br />

indoor temperature to prevent over-cooling.<br />

Refreshing dehumidification can be attained.<br />

INDOOR UNIT<br />

Floor mounted<br />

concealed type<br />

PFFY-P VLRM-E<br />

PFFY-P VLRM-E<br />

Neatly installed with pericover concealed.<br />

Easy installation in perimeter zone.<br />

Compact unit for easy air conditioning in perimeter zone.<br />

The body is concealed in the pericover to pursue harmony with the interior.<br />

The compact body of 220mm(7- 7 /8in.) in depth can be easily installed in the perimeter zone.<br />

Electronics dry function dehumidify refreshingly to prevent over-cooling.<br />

Optimum dehumidification depending on indoor temperature to prevent over-cooling. Refreshing<br />

dehumidification can be attained.<br />

39


INDOOR UNIT<br />

Fresh Air<br />

Intake Type<br />

PEFY-P VMH-E-F<br />

PEFY-P VMH-E-F<br />

Fresh Air can be taken in with temperature control.<br />

Ideal for Offices, Stores and Restaurant.<br />

The Fresh Air intake indoor unit<br />

can be installed in any place.<br />

* Limits of capacity connectable to outdoor unit<br />

Max. 110% of outdoor unit capacity, excepting heating at outdoor temperature of less than -5˚C(23˚F) (100%).<br />

The Fresh Air intake indoor unit can take<br />

fresh outdoor air into any building in any<br />

place at any time.<br />

Office, Lobby, Workshop,<br />

Rest room, nursery home,<br />

Smoking corner,<br />

Kitchen in restaurant<br />

Example<br />

1. Nurcery home<br />

Fresh Air intake<br />

indoor unit<br />

Private room<br />

Ventilating fan<br />

Passage<br />

Air flow<br />

Private room<br />

Ventilating fan<br />

2. Workshop<br />

Exhaust<br />

air<br />

Fresh air<br />

Polluted air<br />

Workshop<br />

Office<br />

Fresh Air intake<br />

indoor unit<br />

Installing fresh Air intake indoor unit (Image)<br />

Fresh Air intake indoor unit<br />

Exhaust<br />

air<br />

EA<br />

Supply air<br />

Fresh<br />

air<br />

OA<br />

< Note><br />

Fan remains of in operation during Thermo-OFF. Using this model with other<br />

type of indoor unit is recommended for Cold Draft prevention because Cold Draft<br />

might occur by using only this model that takes in fresh air.<br />

40


0<br />

INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PLFY-P VCM-E<br />

For 50Hz<br />

Area only<br />

Power source<br />

❇ 1<br />

Cooling capacity<br />

❇ 1<br />

❇ 1<br />

Heating capacity<br />

❇ 1<br />

Power<br />

Cooling<br />

consumption Heating<br />

Cooling<br />

Current<br />

Heating<br />

<strong>External</strong> finish(Munsel No.)<br />

Height<br />

Dimension ❇ 2 Width<br />

Depth<br />

Net weight ❇ 2<br />

Heat exchanger<br />

Type<br />

Fan<br />

Motor<br />

Airflow rate ❇ 2<br />

(Low-Mid-High)<br />

<strong>External</strong> static<br />

pressure<br />

Type<br />

Output<br />

Air filter<br />

Refrigerant<br />

pipe diameter<br />

Gas(Flare)<br />

Liquid(Flare)<br />

Drain pipe diameter<br />

Noise level (Lo-Mid-Hi) ❇2 ❇3<br />

kW<br />

Btu/h<br />

kW<br />

Btu/h<br />

kW<br />

kW<br />

A<br />

A<br />

mm(in.)<br />

mm(in.)<br />

mm(in.)<br />

kg(lbs.)<br />

m 3 /min<br />

L/s<br />

cfm<br />

Pa<br />

kW<br />

mm(in)<br />

mm(in)<br />

dB(A)<br />

<strong>Specifications</strong><br />

PLFY-P20VCM-E PLFY-P25VCM-E PLFY-P32VCM-E PLFY-P40VCM-E<br />

~ (Single phase), 220-230-240V 50Hz<br />

2.2<br />

2.8<br />

3.6<br />

4.5<br />

7,500 9,600 12,300 15,400<br />

2.5<br />

3,2<br />

4.0<br />

5.0<br />

8,500 10,900 13,600 17,100<br />

0.05<br />

0.05<br />

0.23<br />

0.23<br />

0.05<br />

0.05<br />

0.23<br />

0.23<br />

0.06<br />

0.06<br />

0.28<br />

0.28<br />

0.06<br />

0.06<br />

0.28<br />

0.28<br />

Unit: Galvanized sheets with gray heat insulation, Panel: Munsell 0.70Y 8.59/0.97<br />

Unit: 208(8-1/ 4 "), Panel: 20(13/ 16 ")<br />

Unit: 570(22-1/ 2 "), Panel: 650(25-5/ 8 ")<br />

Unit: 570(22-1/ 2 "), Panel: 650(25-5/ 8 ")<br />

Unit: 15.5(35) Unit: 15.5(35) Unit: 17(38) Unit: 17(38)<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Turbo fan × 1<br />

8-9-10 8-9-10 8-9-11 8-9-11<br />

133-150-167 133-150-167 133-150-183 133-150-183<br />

283-318-353 283-318-353 283-318-388 283-318-388<br />

<strong>External</strong> <strong>Dimensions</strong><br />

0 (direct blow)<br />

Single phase induction motor<br />

0.011 0.015 0.020 0.020<br />

PP Honey comb<br />

ø 12.7(1/ 2 ")<br />

ø 6.35(1/ 4 ")<br />

O.D. ø32(1-1/ 4 ") O.D. ø32(1-1/ 4 ") O.D. ø32(1-1/ 4 ") O.D. ø32(1-1/ 4 ")<br />

28-31-35 28-31-37 29-33-38 30-34-39<br />

Note: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇2 <strong>External</strong> dimension/ net weight are shown in , and airflow rate/noise level are in (low-middle2-middle1-high).<br />

❇3 It is measured in anechoic room.<br />

PLFY-P20,25,32,40VCM-E<br />

Unit : mm<br />

15~37<br />

Fresh air intake<br />

Ceiling hole<br />

576~620<br />

420<br />

Suspension bolt pitch<br />

530<br />

Suspension bolt pitch<br />

570<br />

335<br />

570<br />

Detail drawing of fresh air intake hole<br />

ø100 25<br />

ø73.4<br />

3-ø2.8hole<br />

Cut out hole<br />

Burring hole<br />

15~37<br />

199<br />

Drain pipe<br />

352<br />

VP-25 connection<br />

335<br />

(O.D.ø32)<br />

15~37 576~620 Ceiling hole<br />

15~37<br />

Wiring entry<br />

2<br />

17 202<br />

230<br />

Suspension bolt M10 or W3/8<br />

1<br />

Ceiling surface<br />

55 35<br />

Terminal block Grille<br />

650<br />

301<br />

Air outlet hole<br />

V/M<br />

Brand label<br />

Grille<br />

Drain hole<br />

V/M<br />

Auto vane<br />

301<br />

Air outlet hole<br />

Air intake hole<br />

118<br />

120˚<br />

120˚<br />

Suspension bolt lower edge<br />

650<br />

377<br />

48<br />

121<br />

93<br />

66<br />

193<br />

208<br />

235<br />

182<br />

87<br />

57<br />

56<br />

38~58<br />

31<br />

Ceiling surface<br />

27 +5<br />

20<br />

Models<br />

1<br />

2<br />

41<br />

V/M<br />

35 55<br />

377<br />

Air intake hole<br />

V/M<br />

Air intake grille<br />

Vane motor<br />

PLFY-P20VCM-E<br />

PLFY-P25VCM-E<br />

PLFY-P32VCM-E<br />

PLFY-P40VCM-E<br />

Refrigerant pipe<br />

(6.35mm dia.)<br />

flared connection<br />

1/4F<br />

Refrigerant pipe<br />

(12.7mm dia.)<br />

flared connection<br />

1/2F


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PLFY-P VAM-E<br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

Power<br />

consumption<br />

Current<br />

❇1<br />

❇1<br />

❇2<br />

❇2<br />

❇1<br />

❇1<br />

❇1<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

<strong>External</strong> finish(Munsel No.)<br />

Dimension H x W x D ❇ 3<br />

Net weight ❇ 3<br />

Heat exchanger<br />

Type<br />

Fan<br />

Airflow rate ❇ 3<br />

(Low-Mid2-Mid1-High)<br />

<strong>External</strong> static<br />

pressure<br />

Type<br />

Motor<br />

Output<br />

Air filter<br />

Refrigerant<br />

pipe diameter<br />

Gas<br />

(Flare)<br />

Liquid<br />

(Flare)<br />

Drain pipe diameter<br />

Noise level (Lo-Mid2-Mid1-Hi) ❇3 ❇4<br />

kW<br />

BTU/h<br />

kW<br />

kcal/h<br />

kW<br />

kcal/h<br />

BTU/h<br />

kW<br />

kW<br />

A<br />

A<br />

mm<br />

in.<br />

kg(lbs.)<br />

m 3 /min<br />

L/s<br />

cfm<br />

Pa<br />

kW<br />

mm(in.)<br />

mm(in.)<br />

dB(A)<br />

PLFY-P32,40,50,63,80,100,125VAM-E<br />

<strong>Specifications</strong><br />

PLFY-P32VAM-E PLFY-P40VAM-E PLFY-P50VAM-E PLFY-P63VAM-E<br />

~ 220-240V 50Hz / ~ 220V 60Hz<br />

3.6 4.5 5.6 7.1<br />

12,300<br />

15,400 19,100 24,200<br />

3.7<br />

4.7 5.8<br />

7.3<br />

3,150 4,000 5,000 6,300<br />

4.0 5.0 6.3 8.0<br />

3,400<br />

4,300 5,400 6,900<br />

13,600<br />

17,100 21,500 27,300<br />

0.12<br />

0.12<br />

0.59<br />

0.59<br />

Note: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27 ˚C(80.6˚F) DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F))<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F))<br />

❇ 3 <strong>External</strong> dimension/ net weight are shown in , and airflow rate/noise level are in (low-middle2-middle1-high).<br />

❇ 4 It is measured in anechoic room.<br />

0.14<br />

0.14<br />

0.68<br />

0.68<br />

0.16<br />

0.16<br />

0.78<br />

0.78<br />

Panel : 0.70Y 8.59/0.97<br />

258x 840 x 840<br />

298(30) x 840(950) x 840(950)<br />

10-3/16"


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PLFY-P VLMD-E<br />

Power source<br />

❇ 1<br />

❇ 1<br />

Cooling capacity<br />

❇ 2<br />

❇ 2<br />

❇ 1<br />

Heating capacity<br />

❇ 1<br />

❇ 1<br />

Power<br />

Cooling<br />

consumption Heating<br />

Cooling<br />

Current<br />

Heating<br />

<strong>External</strong> finish(Munsel No.)<br />

Dimension H x W x D ❇ 3<br />

Net weight<br />

❇ 3<br />

Heat exchanger<br />

Type<br />

Fan<br />

Motor<br />

Air filter<br />

Airflow rate (Lo-Mid-Hi)<br />

<strong>External</strong> static pressure<br />

Type<br />

Output<br />

kW<br />

BTU/h<br />

kW<br />

kcal/h<br />

kW<br />

kcal/h<br />

BTU/h<br />

kW<br />

kW<br />

A<br />

A<br />

mm<br />

in.<br />

kg(lbs.)<br />

m 3 /min<br />

L/s<br />

cfm<br />

Pa<br />

kW<br />

<strong>Specifications</strong><br />

PLFY-P20VLMD-E PLFY-P25VLMD-E PLFY-P32VLMD-E PLFY-P40VLMD-E<br />

~ 220-240V 50Hz / ~ 220-230V 60Hz<br />

2.2<br />

2.8<br />

3.6<br />

4.5<br />

7,500 9,600 12,300<br />

15,400<br />

2.3 2.9 3.7<br />

4.7<br />

2,000<br />

2,500<br />

3,150<br />

4,000<br />

2.5<br />

3.2<br />

4.0<br />

5.0<br />

2,200 2,800 3,400<br />

4,300<br />

8,500 10,900 13,600<br />

17,100<br />

0.072 / 0.075<br />

0.065 / 0.069<br />

0.36 / 0.37<br />

0.30 / 0.32<br />

0.072 / 0.075<br />

0.065 / 0.069<br />

0.36 / 0.37<br />

0.30 / 0.32<br />

0.072 / 0.075<br />

0.065 / 0.069<br />

0.36 / 0.37<br />

0.30 / 0.32<br />

0.081 / 0.085<br />

0.074 / 0.079<br />

0.40 / 0.42<br />

0.34 / 0.37<br />

Unit: Galvanizing Decoration Panel: ABS (0.7Y 8.59/0.97) Service Panel: Galvanizing (0.7Y 8.59/0.97)<br />

290 x 776 x 634<br />

11- 7 /16"< 13 /16"> x30- 9 /16"


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PLFY-P VLMD-E<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E<br />

Unit : mm<br />

Note: 1.Use M10 screw for the lifing bolt (field supply).<br />

2.It is available to connect the branch duct on right and left side both.<br />

3.On Model :50, 100, you would use flare nut packed with the Indoor<br />

Unit, when connnecting the Outdoor Unit for R407C, R22.<br />

4.In order to increase the strength of the flare nut, the size of some<br />

of them has been increased.<br />

H<br />

240 197<br />

190 222 4-ø2.9 Mounting hole<br />

45 216<br />

73 202<br />

48<br />

70 146<br />

<br />

Model Gas pipe:LP ø12.7<br />

20·25·32·40 Liquid pipe:HP ø6.35<br />

574<br />

507<br />

634<br />

670<br />

Model Gas pipe:LP ø12.7<br />

50 ø15.88<br />

Liquid pipe:HP ø6.35<br />

ø9.52<br />

Model Gas pipe:LP ø15.88<br />

63·80 Liquid pipe:HP ø9.52<br />

Model Gas pipe:LP ø15.88<br />

100 ø19.05<br />

Liquid pipe:HP ø9.52<br />

Drain hose VP-25 (accessory)<br />

48<br />

108<br />

Branch duct Fx110 knock out hole<br />

(both side)(Note:2)<br />

D(Lifting Bolt Pitch)<br />

B<br />

D(Lifting bolt pitch)<br />

C<br />

F<br />

108<br />

G-ø2.9 Mounting hole<br />

221<br />

Control box<br />

E<br />

3<br />

Terminal bed(Power source)<br />

Terminal bed(Transmission)<br />

Terminal box<br />

68<br />

574 (Lifting Bolt Pitch)<br />

634<br />

497<br />

70<br />

146<br />

68<br />

2<br />

1<br />

45<br />

110<br />

159<br />

266<br />

122<br />

190<br />

290<br />

More Than 350<br />

60<br />

52<br />

34<br />

20 B<br />

20<br />

20<br />

670<br />

20<br />

20<br />

Fresh air intake 240x45 knock out hole<br />

Drain hole<br />

Water filling port<br />

Air filter<br />

Standard center panel<br />

A<br />

300mm or less<br />

Model<br />

PLFY-P20VLMD-E<br />

PLFY-P25VLMD-E<br />

PLFY-P32VLMD-E<br />

PLFY-P40VLMD-E<br />

PLFY-P50VLMD-E<br />

PLFY-P63VLMD-E<br />

PLFY-P80VLMD-E<br />

PLFY-P100VLMD-E<br />

CMP-40VLW-B 1080 1040 776 824 388<br />

CMP-63VLW-B<br />

A<br />

B<br />

C<br />

1250 1210 946<br />

D<br />

994<br />

E<br />

473<br />

F<br />

217.5✕2<br />

=435<br />

188.5✕4<br />

CMP-100VLW-B 1750 1710 1446 1494 723<br />

=754<br />

10<br />

G H(Liquid) H(Gas)<br />

6<br />

17<br />

22<br />

22<br />

27<br />

29<br />

36<br />

710<br />

583mmMAX<br />

3<br />

170mm ± 5mm(Actual Length)<br />

PLFY-P125VLMD-E<br />

48<br />

574<br />

48<br />

Fresh air intake ø150 knock out hole<br />

303<br />

107 1756<br />

1970<br />

127<br />

1756(Lifting bolt pitch)<br />

1708<br />

45˚<br />

856<br />

107<br />

Branch duct ø200 knock out hole (both side)<br />

127<br />

606<br />

670<br />

1<br />

2<br />

3<br />

Terminal bed<br />

(Transmission)<br />

Terminal bed<br />

(Power source)<br />

Note: 1.Use M10 screw for the lifting bolt (field supply).<br />

2.On this model, you would use flare nut packed<br />

with the Indoor Unit, when connnecting the<br />

Outdoor Unit for R407C, R22.<br />

3.In order to increase the strength of theflare nut,<br />

the size of some of them has been increased.<br />

Model<br />

PLFY-P125VLMD-E<br />

38<br />

A(Liquid) A(Gas)<br />

22 36<br />

<br />

Gas pipe:LP ø15.88<br />

ø19.05<br />

Liquid pipe:HP ø9.52<br />

Drain hose VP-25 (accessory)<br />

Water filling port<br />

68 574(Lifting bolt pitch) 68<br />

606<br />

476<br />

70 178<br />

106<br />

3 1<br />

2<br />

A<br />

ø172<br />

90˚<br />

90˚<br />

4-ø2.9Mounting hole<br />

181<br />

20<br />

145<br />

90˚<br />

ø224<br />

1970(Ceiling opening)<br />

Control box<br />

4-ø2.8Mounting hole<br />

20<br />

235<br />

Terminal box<br />

Air filter<br />

222<br />

70 333<br />

20 670(Ceiling opening) 20<br />

155<br />

192<br />

255<br />

290<br />

Drain hole<br />

45<br />

20 338~353<br />

More than 350<br />

2010<br />

300mm or less<br />

170mm±5mm(Actual length)<br />

710<br />

600mm Max<br />

3<br />

Standard center panel<br />

(CMP-125VLW-B)<br />

44


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PMFY-P VBM-E<br />

<strong>Specifications</strong><br />

PMFY-P20VBM-E PMFY-P25VBM-E PMFY-P32VBM-E PMFY-P40VBM-E<br />

Power source<br />

~220-240V 50Hz / ~ 220V 60Hz<br />

❇1 kW<br />

2.2 2.8 3.6<br />

4.5<br />

Cooling capacity<br />

❇1 BTU/h<br />

7,500 9,600 12,300<br />

15,400<br />

❇2 kW<br />

2.3 2.9 3.7<br />

4.7<br />

❇2 kcal/h<br />

2,000 2,500 3,150 4,000<br />

❇1 kW<br />

2.5 3.2 4.0<br />

5.0<br />

Heating capacity<br />

❇1 kcal/h<br />

2,200 2,800 3,400<br />

4,300<br />

❇1 BTU/h<br />

8,500 10,900 13,600<br />

17,100<br />

Power consumption<br />

Cooling kW<br />

0.042<br />

0.044<br />

0.054<br />

Heating kW<br />

0.042<br />

0.044<br />

0.054<br />

Current<br />

Cooling A<br />

0.20<br />

0.21<br />

0.26<br />

Heating A<br />

0.20<br />

0.21<br />

0.26<br />

<strong>External</strong> finish<br />

Panel : 0.98Y8.99/0.63<br />

Dimension H x W x D ❇ 3<br />

mm(in.) 230 x 812 x 395 (9- 1 /16"


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

New<br />

PEFY-P VMR-E-L/R<br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

Power consumption<br />

Current<br />

<strong>External</strong> finish<br />

Drain pipe diameter<br />

Noise level<br />

(Low-Mid2-Mid1-High)<br />

❇ 4<br />

Note:<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Dimension H x W x D<br />

Net weight ❇ 3<br />

Heat exchanger<br />

Type<br />

Airflow rate<br />

(Low-Mid-High)<br />

Fan<br />

<strong>External</strong> static pressure<br />

Type<br />

Motor<br />

Output<br />

Air filter<br />

Refrigerant<br />

pipe diameter<br />

❇ 3<br />

Gas(Flare)<br />

Liquid(Flare)<br />

mm(in.)<br />

kg(lbs.)<br />

m 3 /min<br />

Pa<br />

kW<br />

mm(in.)<br />

mm(in.)<br />

<strong>Specifications</strong><br />

PEFY-P20VMR-E-L/R PEFY-P25VMR-E-L/R PEFY-P32VMR-E-L/R<br />

1-phase 220/230/240 V 50Hz 220/230V 60Hz<br />

❇1 kW<br />

2.2 2.8 3.6<br />

❇1 BTU/h<br />

7,500 9,600 12,300<br />

❇2 kW<br />

2.3 2.9 3.7<br />

❇2 kcal/h<br />

2,000 2,500 3,150<br />

❇1 kW<br />

2.5 3.2 4.0<br />

❇1 kcal/h<br />

2,200 2,800 3,400<br />

❇1 BTU/h<br />

8,500 10,900 13,600<br />

kW<br />

0.06/0.06<br />

0.06/0.06<br />

0.07/0.08<br />

kW<br />

0.06/0.06<br />

0.06/0.06<br />

0.07/0.08<br />

A<br />

0.29/0.29<br />

0.29/0.29<br />

0.34/0.38<br />

A<br />

0.29/0.29<br />

0.34/0.38<br />

220V<br />

20-25-30 20-25-33<br />

230V dB(A)<br />

21-26-32 21-26-35<br />

240V 22-27-30<br />

22-27-33<br />

❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling: Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB<br />

Heating: Indoor 20˚C (68˚F) DB, Outdoor 7˚C (45˚F)DB/6˚C (43˚F) WB<br />

❇2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F))<br />

<strong>External</strong> <strong>Dimensions</strong><br />

0.29/0.29<br />

Galvanized<br />

292 x 640 x 580<br />

18 (40)<br />

Cross fin (Aluminum fin and copper tube)<br />

Sirocco fan ✕ 1<br />

4.8-5.8-7.9 4.8-5.8-9.3<br />

5<br />

1-phase induction motor<br />

0.018<br />

PP Honeycomb fabric (washable)<br />

ø 6.35( 1/4")<br />

ø 12.7(1/2")<br />

O.D. 26(1-1/32)<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F))<br />

❇3 The external static pressure is set to 100Pa (at 220V) / 150Pa (at 230, 240V) at factory shipment.<br />

❇4 Measured in anechoic room. Noise levels of the unit with a rear air inlet. (Noise levels are higher for the unit with a<br />

bottom air inlet.)<br />

0.023<br />

PEFY-P20,25,32VMR-E-L/R<br />

Right side<br />

Unit : mm<br />

Air filter<br />

630<br />

300 (In case of bottom inlet) 23<br />

584 (Suspension bolt pitch)<br />

292 (In case of rear inlet)<br />

80 530<br />

50 or below<br />

Rear<br />

air inlet<br />

Suspension bolt hole<br />

Suspension bolt outlet<br />

(Note 1)<br />

Rear<br />

air inlet<br />

Terminal bed (Power source)<br />

Terminal bed (M-Net Transmission)<br />

Control box<br />

439 (Suspension bolt pitch) 105<br />

580 (In case of rear inlet)<br />

570 (In case of bottom inlet)<br />

2<br />

1<br />

3<br />

Bottom plate 113<br />

148<br />

Bottom air inlet<br />

2x10-ø3<br />

Air outlet<br />

2x2-ø3<br />

50x9=450<br />

480<br />

622<br />

50<br />

15<br />

62 25<br />

100<br />

Left side<br />

30<br />

15<br />

50 25<br />

100 28<br />

275<br />

250<br />

Note 1. Use M10 screw for the suspension bolt (field supply).<br />

50mm or below of clearance between the Indoor unit top and the end of the<br />

suspension bolt will make maintenance of the Indoor heat exchanger easier.<br />

2. Access door of 450mm x 450mm at the ceiling under the drain pan should be<br />

designed for heat exchanger cleaning and maintenance.<br />

3. This drawing shows the left piping specification. The symmetry shows the<br />

right piping specification.<br />

Model name: PEFY-P20 · 25 · 32VMR-E-L<br />

PEFY-P20 · 25 · 32VMR-E-R<br />

4. Period cleaning of drain pan will prevent water overflowing.<br />

Gradient piping design is needed for water draining.<br />

5. The inlet direction can be changed between rear inlet and bottom inlet.<br />

Keep the inlet space between the ceiling and the unit in case of bottom<br />

inlet.<br />

Required space for service and maintenance<br />

(Note 2)<br />

300<br />

25<br />

450 50~150<br />

450<br />

500<br />

50~150<br />

Make the access door at the appointed position properly<br />

for service maintenance.<br />

Access door<br />

Ceiling surface<br />

More than 20mm<br />

More than 20mm<br />

Drain pan<br />

Hose band<br />

Insulation material<br />

Adhesion<br />

Rigid vinyl drain pipe<br />

<br />

Insulation material<br />

or drain pan<br />

Urethane foam<br />

150<br />

Do not leave space.<br />

Drain hose (accessory)<br />

Refrigerant pipe (gas) brazed<br />

Refrigerant pipe (liquid) brazed<br />

Drain pipe connection diameter<br />

ø12.7·································➀<br />

ø6.35·································➁<br />

VP20(dia. 26mm) ·············➂<br />

46


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

New<br />

PEFY-P VMS-E<br />

Power source<br />

Cooling capacity<br />

❇1<br />

Heating capacity<br />

❇1<br />

Power input<br />

Current<br />

Temperature set range Remote controller<br />

Fan ❇2 Type x Quantity<br />

<strong>External</strong> static press<br />

Motor type<br />

Motor output<br />

Airflow rate(Low-Mid-High)<br />

<strong>External</strong> finish<br />

<strong>External</strong> dimension<br />

H x W x D<br />

Net weight<br />

Refrigerant piping Liquid R410A<br />

diameter<br />

R407C,R22<br />

Gas<br />

Drain piping diameter<br />

Noise level (Low-Mid-High)<br />

(mesured in anechoic room)<br />

Air filter<br />

Connectable outdoor unit<br />

Heat exchanger<br />

R410A<br />

R407C,R22<br />

kW<br />

kW<br />

kW<br />

A<br />

˚C(˚F)<br />

Pa<br />

kW<br />

m 3 /min<br />

mm<br />

In.<br />

kg<br />

mm(in.)<br />

mm(in.)<br />

mm(in.)<br />

mm(in.)<br />

mm(in.)<br />

dB<br />

<strong>Specifications</strong><br />

PEFY-P20VMS-E PEFY-P25VMS-E PEFY-P32VMS-E PEFY-P40VMS-E PEFY-P50VMS-E PEFY-P63VMS-E<br />

1-phase 220-240V 50Hz 1-phase 220-230V 60Hz<br />

2.2<br />

2.8<br />

3.6<br />

4.5<br />

5.6<br />

7.1<br />

2.5<br />

3.2<br />

4.0<br />

5.0<br />

6.3<br />

8.0<br />

0.08 0.06<br />

0.39 0.28<br />

19 to 30 (67 to 86) 17 to 28 (63 to 83)<br />

0.08<br />

0.39<br />

19 to 30 (67 to 86)<br />

0.06<br />

0.28<br />

17 to 28 (63 to 83)<br />

0.09<br />

0.44<br />

19 to 30 (67 to 86)<br />

0.07<br />

0.33<br />

17 to 28 (63 to 83)<br />

0.11<br />

0.53<br />

19 to 30 (67 to 86)<br />

Note: ❇ 1.Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Indoor : 27˚CD.B./19˚CW.B. (81˚FD.B. / 66˚FW.B.) Outdoor : 35˚CD.B. (95˚FD.B. )<br />

Indoor : 20˚CD.B. (68˚FD.B.) Outdoor : 7˚CD.B. / 6˚CW.B. (45˚FD.B. / 43˚FW.B.)<br />

Pipe length : 7.5m (24-9/16ft) Height difference : 0m (0ft)<br />

❇ 2.The external static pressure is set to 15 Pa at factory shipment.<br />

6-7-8<br />

22-25-27<br />

0.09<br />

0.42<br />

17 to 28 (63 to 83)<br />

Sirocco fan x 3<br />

5-15-35-50<br />

DC brushless motor<br />

0.096<br />

7.5-8.5-10<br />

8-9.5-11<br />

Galvanized<br />

200 x 900 x 700<br />

7-7/8 x 35-7/16 x 27-9/16<br />

23 24<br />

ø6.35(ø1/4) Brazed<br />

ø6.35(ø1/4) Brazed<br />

ø12.7(ø1/2) Brazed<br />

ø12.7(ø1/2) Brazed<br />

25-28-30<br />

O.D. 32(1-9/32)<br />

28-30-33<br />

PP Honeycomb fabric (washable)<br />

R410A, R407C, R22 CITY MULTI<br />

Cross fin(Aluminium fin and copper tube)<br />

0.13<br />

0.63<br />

19 to 30 (67 to 86)<br />

0.11<br />

0.52<br />

17 to 28 (63 to 83)<br />

9.5-11-13<br />

ø6.35(ø1/4) Brazed<br />

ø9.52(ø3/8) Brazed<br />

ø12.7(ø1/2) Brazed<br />

ø15.88(ø5/8) Brazed<br />

30-32-35<br />

0.14<br />

0.68<br />

19 to 30 (67 to 86)<br />

0.12<br />

0.57<br />

17 to 28 (63 to 83)<br />

Sirocco fan x 4<br />

12-14-16.5<br />

200 x 1100 x 700<br />

7-7/8 x 43-5/16 x 27-9/16<br />

28<br />

ø9.52(ø3/8) Brazed<br />

ø9.52(ø3/8) Brazed<br />

ø15.88(ø5/8) Brazed<br />

ø15.88(ø5/8) Brazed<br />

30-33-36<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P20,25,32,40,50,63VMS-E<br />

Unit : mm<br />

15<br />

20<br />

12<br />

157.5<br />

37 100<br />

37<br />

20 157.5<br />

12 37 100<br />

37<br />

25<br />

57<br />

2 X E-ø2.9<br />

2 Refrigerant piping<br />

brazing connection (liquid)<br />

D (Duct)<br />

30 100 X (E-1)=F<br />

100<br />

20<br />

Air<br />

outlet<br />

100<br />

150(Duct) 23<br />

100 25<br />

10<br />

49<br />

23<br />

10<br />

270<br />

625(Suspension bolt pitch)<br />

700<br />

677<br />

Drain pipe<br />

(O.D.ø32)<br />

Drainpump<br />

Air<br />

inlet<br />

20-ø2.9<br />

Air filter<br />

Suspension bolt hole<br />

4-14 X 30 Slot<br />

Knockout hole ø27<br />

(Power source wiring)<br />

Control box<br />

48<br />

A<br />

90<br />

102<br />

170<br />

B (Suspension bolt pitch)<br />

C<br />

23<br />

200<br />

20<br />

860<br />

12 88<br />

100 X 7=700<br />

88<br />

100<br />

Knockout hole ø27<br />

(Transmission wiring)<br />

1060<br />

88<br />

100 X 9=900<br />

88<br />

100<br />

20<br />

12<br />

24-ø2.9<br />

Model:P63(Note3)<br />

Air filter<br />

Air filter<br />

50<br />

More than 20mm<br />

More than 20mm<br />

50<br />

G 450<br />

Note2<br />

50~150<br />

175mm +- 5 mm<br />

(Actual length)<br />

Less than 300mm<br />

777<br />

450<br />

More than 300<br />

Access door<br />

Required space for service and maintenance<br />

Ceiling surface<br />

Access door<br />

Make the access door at the appointed position properly<br />

for service maintenance.<br />

Drain hose (I.D.ø32)<br />

<br />

Less than 550mm<br />

2 X 2-ø2.9<br />

116 70<br />

1 Refrigerant piping<br />

270<br />

Drain pipe(O.D.ø32)<br />

brazing connection (gas)<br />

(Spontaneous draining)<br />

Model<br />

A B C D<br />

PEFY-P20,25,32,40VMS-E<br />

PEFY-P50VMS-E<br />

PEFY-P63VMS-E<br />

900<br />

1100<br />

952<br />

1152<br />

998<br />

1198<br />

860<br />

1060<br />

E<br />

9<br />

11<br />

Terminal bed(Power source)<br />

Terminal bed(Transmission)<br />

F<br />

800<br />

G<br />

1000<br />

1000 1200<br />

1Gas pipe 2 Liquid pipe<br />

ø12.7 ø6.35<br />

✻1<br />

✻2<br />

ø12.7<br />

ø15.88<br />

ø15.88<br />

✻1<br />

✻2<br />

ø6.35<br />

ø9.52<br />

ø9.52<br />

Note 1. Use M10 screw for the Suspension bolt (field supply).<br />

2. Keep the service space for the maintenance at<br />

the bottom.<br />

3. This chart indicates for PEFY-P20~50VMS-E models,<br />

which has 3 fans. PEFY-P63VMS-E model have 4 fans.<br />

4. In case of the inlet duct is used,remove the air filter(supply with<br />

the unit), then install the filter(field supply) at suction side.<br />

✻1 : R410A outdoor unit<br />

✻2 : R407C,R22 outdoor unit<br />

47


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P VML-E<br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

Power consumption<br />

(50/60Hz)<br />

Current<br />

<strong>External</strong> finish<br />

Dimension H x W x D<br />

Net weight<br />

Heat exchanger<br />

Fan<br />

Motor<br />

Air filter<br />

Type<br />

Airflow rate<br />

(Lo-Mid-Hi)<br />

<strong>External</strong> static pressure<br />

Type<br />

Output<br />

Refrigerant<br />

pipe diameter<br />

Drain pipe diameter<br />

Noise level (Lo-Mid-Hi)<br />

Note:<br />

PEFY-P20,25,32VML-E<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

❇1<br />

❇1<br />

❇2<br />

❇2<br />

❇1<br />

❇1<br />

❇1<br />

Gas(Brazing)<br />

Liquid(Brazing)<br />

kW<br />

BTU/h<br />

kW<br />

kcal/h<br />

kW<br />

kcal/h<br />

BTU/h<br />

kW<br />

kW<br />

A<br />

A<br />

mm(in.)<br />

kg(lbs.)<br />

m 3 /min<br />

L/s<br />

cfm<br />

Pa<br />

kW<br />

mm(in.)<br />

mm(in.)<br />

<strong>Specifications</strong><br />

❇5 dB(A)<br />

❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚(44.6˚F)CDB/6˚C(42.8˚F)WB<br />

❇ 2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(42.8˚F)DB (WR2: water 30˚C(80˚F))<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F))<br />

❇ 3 The external static pressure is set to 100Pa (at 220V) /150Pa (at 230, 240V) at factory shipment.<br />

❇ 4 The value are that at 240V.<br />

❇ 5 It is measured in anechoic room.<br />

The part air intake duct is attached. (✻3)<br />

(When the air intake duct is used)<br />

PEFY-P20VML-E PEFY-P25VML-E PEFY-P32VML-E<br />

~ 220-240V 50Hz / 60Hz<br />

2.2 2.8 3.6<br />

7,500 9,600 12,300<br />

2.3 2.9 3.7<br />

2,000 2,500 3,150<br />

2.5 3.2 4.0<br />

2,200 2,800 3,400<br />

8,500 10,900 13,600<br />

0.05/0.06<br />

0.07/0.09<br />

0.05/0.06<br />

0.07/0.09<br />

0.24/0.28<br />

0.32/0.42<br />

0.24/0.28<br />

0.32/0.42<br />

Galvanizing<br />

225 x 720 x 550 (8- 7 /8" x 28- 3 /8" x 21- 11 /16")<br />

18 (40)<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Sirocco fan ✕ 1<br />

4.8-5.8-7.9 4.8-5.8-9.5<br />

80-97-132 80-97-158<br />

170-205-279 170-205-335<br />

5<br />

Single phase induction motor<br />

0.023 0.032<br />

PP Honeycomb fabric (washable)<br />

ø 12.7( 1 /2")<br />

ø 6.35( 1 /4")<br />

R1 (<strong>External</strong> thread)<br />

25-29-36 25-29-40<br />

<strong>External</strong> <strong>Dimensions</strong><br />

Unit : mm<br />

Air filter<br />

710<br />

23 664 (Lifting bolt pitch)<br />

80<br />

610<br />

Air inlet<br />

Lifting bolt<br />

Control box<br />

459 (Lifting bolt pitch)<br />

550 (✻1)<br />

510<br />

2 1 148<br />

80<br />

30<br />

15<br />

55<br />

2✕3-ø3<br />

13.5<br />

14<br />

12-ø3<br />

Air outlet<br />

15<br />

14<br />

16 50<br />

50✕11=550<br />

720<br />

582<br />

42.5<br />

65.5<br />

204.5<br />

Bottom plate<br />

Note 1.Use M10 screw for the lifting bolt (field supply).<br />

2.Keep the service space for the maintenance<br />

from the bottom when the heat exchanger is<br />

cleaned.<br />

3.The direction of air intake can be changed from<br />

the bottom to the rear by attaching the bottom<br />

plate to the air intake side.<br />

4.Drain Pan is changeable from right and left.<br />

5.The dimension is changed, in case the optional<br />

long-life filter is attached.<br />

RearAir-Intake spec.:Depth is increased by<br />

30mm(✻1)<br />

BottomAir-Intake spec.:Height is increased<br />

by 30mm(✻2)<br />

Refrigerant piping brazing connection<br />

(gas ø12.7 copper tube):LP ··· 1<br />

Refrigerant piping brazing connection<br />

(liquid ø6.35 copper tube):HP ··· 2<br />

Drain piping connection R1 (<strong>External</strong> thread) ··· 3<br />

540<br />

In case of rear inlet<br />

Air inlet<br />

50<br />

50<br />

127<br />

225 (✻2)<br />

In case of bottom inlet<br />

Air filter<br />

Terminal bed<br />

(Power source)<br />

Terminal bed<br />

(Transmission)<br />

3<br />

Bottom plate<br />

113<br />

Air filter<br />

Air inlet<br />

48


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P VMM-E<br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

Power consumption<br />

(50Hz)<br />

Current<br />

<strong>External</strong> finish<br />

Dimension H x W x D<br />

Net weight<br />

Heat exchanger<br />

Type<br />

Fan<br />

Airflow rate<br />

(Lo-Mid-Hi)<br />

❇ 1<br />

❇ 1<br />

❇ 2<br />

❇ 2<br />

❇ 1<br />

❇ 1<br />

❇ 1<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

<strong>External</strong> static pressure<br />

Type<br />

Motor<br />

Output<br />

Air filter<br />

Gas<br />

Refrigerant (Flare)<br />

pipe diameter Liquid<br />

(Flare)<br />

Drain pipe diameter<br />

Noise level (Lo-Mid-Hi) ❇ 3<br />

kW<br />

BTU/h<br />

kW<br />

kcal/h<br />

kW<br />

kcal/h<br />

BTU/h<br />

kW<br />

kW<br />

A<br />

A<br />

mm(in.)<br />

kg(lbs.)<br />

m 3 /min<br />

L/s<br />

cfm<br />

Pa<br />

kW<br />

mm(in.)<br />

mm(in.)<br />

dB(A)<br />

6.0-7.2-8.5<br />

<strong>Specifications</strong><br />

PEFY-P20VMM-E PEFY-P25VMM-E PEFY-P32VMM-E PEFY-P40VMM-E<br />

~220-240V 50Hz<br />

2.2 2.8<br />

3.6<br />

4.5<br />

7,500 9,600 12,300<br />

15,400<br />

2.3 2.9 3.7<br />

4.7<br />

2,000 2,500 3,150<br />

4,000<br />

2.5 3.2 4.0<br />

5.0<br />

2,200 2,800 3,400<br />

4,300<br />

8,500 10,900 13,600<br />

17,100<br />

0.15<br />

0.17<br />

0.19<br />

0.15<br />

0.17<br />

0.19<br />

0.73<br />

0.81<br />

0.92<br />

0.73<br />

0.81<br />

0.92<br />

295 x 815 x 700<br />

(11- 5 /8 "x 32- 1 /8" x 27- 9 /16")<br />

27(60)<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Sirocco fan✕ 1 Sirocco fan✕ 2<br />

100-120-142 125-150-175 167-200-233 200-242-283 225-270-317<br />

212-254-300 265-318-371 353-424-494 424-512-600 477-572-671<br />

30/50/100<br />

Single phase induction motor<br />

0.075<br />

0.078<br />

PP Honeycomb fabric (washable)<br />

27-30-32<br />

ø 12.7( 1 /2")<br />

ø 6.35( 1 /4")<br />

7.5-9.0-10.5<br />

10.0-12.0-14.0<br />

R1 (<strong>External</strong> thread)<br />

28-32-35 31-34-37<br />

PEFY-P50VMM-E<br />

PEFY-P63VMM-E<br />

5.6<br />

7.1<br />

19,100 24,200<br />

5.8 7.3<br />

5,000 6,300<br />

6.3<br />

8.0<br />

5,400 6,900<br />

21,500 27,300<br />

0.20<br />

0.22<br />

0.20<br />

0.22<br />

0.98<br />

1.07<br />

0.98<br />

1.07<br />

Galvanizing<br />

295 x 935 x 700<br />

295 x 1,175 x 700<br />

(11- 5 /8" x 36- 13 /16" x 27- 9 /16") (11- 5 /8" x 46- 5 /16" x 27- 9 /16")<br />

33(73) 42(93)<br />

12.0-14.5-17.0<br />

ø 12.7( 1 /2")[R410A]<br />

ø 15.88( 5 /8")[R22,R407C]<br />

ø 6.35( 1 /4")[R410A]<br />

ø 9.52( 3 /8")[R22,R407C]<br />

31-35-38<br />

13.5-16.2-19.0<br />

ø 15.88( 5 /8")<br />

ø 9.52( 3 /8")<br />

49<br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

Power consumption<br />

(50Hz)<br />

Current<br />

<strong>External</strong> finish<br />

Dimension H x W x D<br />

Net weight<br />

Heat exchanger<br />

Type<br />

Fan<br />

Airflow rate<br />

(Lo-Hi)<br />

❇ 1<br />

❇ 1<br />

❇ 2<br />

❇ 2<br />

❇ 1<br />

❇ 1<br />

❇ 1<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

<strong>External</strong> static pressure<br />

Type<br />

Motor<br />

Output<br />

Air filter<br />

Gas<br />

Refrigerant (Flare)<br />

pipe diameter Liquid<br />

(Flare)<br />

kW<br />

BTU/h<br />

kW<br />

kcal/h<br />

kW<br />

kcal/h<br />

BTU/h<br />

kW<br />

kW<br />

A<br />

A<br />

mm(in.)<br />

PEFY-P71VMM-E PEFY-P80VMM-E PEFY-P100VMM-E<br />

~220-240V 50Hz<br />

PEFY-P125VMM-E PEFY-P140VMM-E<br />

8.0<br />

27,300<br />

9.0<br />

30,700<br />

11.2<br />

38,200<br />

14.0<br />

47,800<br />

16.0<br />

54,600<br />

8.3<br />

9.3<br />

11.6 14.5 16.3<br />

7,100<br />

8,000<br />

10,000<br />

12,500<br />

14,000<br />

9.0<br />

10.0<br />

12.5<br />

16.0<br />

18.0<br />

7,700<br />

8,600<br />

10,800 13,800 15,500<br />

30,700<br />

34,100<br />

42,700 54,600 61,400<br />

0.25<br />

0.29<br />

0.40<br />

0.42<br />

0.25<br />

0.29<br />

0.40<br />

0.42<br />

1.15<br />

1.34<br />

1.90<br />

1.95<br />

1.15<br />

1.34<br />

1.90<br />

1.95<br />

Galvanizing<br />

295 x 1,175 x 700<br />

325 x 1,415 x 740 325 x 1,715 x 740<br />

(11-5/8" x 46-5/16" x 27-9/16") (12-13/16" x 55-3/4" x 29-3/16") (12-13/16" x 67-9/16" x 29-3/16")<br />

kg(lbs.)<br />

42(93)<br />

62(137) 65(144) 70(155)<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Sirocco fan✕2<br />

m 3 /min<br />

L/s<br />

cfm<br />

14.5-18.0-21.0<br />

242-300-350<br />

512-636-742<br />

23.0-33.0<br />

383-550<br />

812-1165<br />

28.0-40.0<br />

467-667<br />

989-1413<br />

29.5-42.0<br />

492-700<br />

1042-1483<br />

Pa 30/50/100<br />

50/130<br />

Single phase induction motor<br />

kW<br />

0.078<br />

0.200<br />

PP Honeycomb fabric (washable)<br />

0.280<br />

mm(in.)<br />

mm(in.)<br />

ø 15.88(5/8")<br />

ø 15.88(5/8") [R410A]<br />

ø 19.05(3/4") [R22,R407C]<br />

ø 9.52 (3/8")<br />

Drain pipe diameter<br />

R1 (<strong>External</strong> thread)<br />

Noise level (Lo-Mid-Hi) ❇ 3 dB(A) 32-36-39<br />

40-44 42-45 42-45<br />

Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇ 2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F))<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇ 3 It is measured in anechoic room.<br />

(WR2: water 20˚C(68˚F))


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P VMM-E<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P20,25,32,40,50,63,71,80VMM-E<br />

Unit : mm<br />

Note: 1. On Model :50, you would use flare nut packed<br />

with the Indoor Unit, when connnecting the<br />

Outdoor Unit for R407C, R22.<br />

2. In order to increase the strength<br />

of the flare nut, the size of some<br />

of them has been increased.<br />

1 Refrigerant piping flare connection (liquid øF copper tube):HP<br />

2 Refrigerant piping flare connection (gas øG copper tube) :LP<br />

3 Drain R1(<strong>External</strong> thread)<br />

4 Electrical parts box<br />

5 Drain Pump (Option)<br />

Set<br />

6 Drain Pipe (Option)···Flexible joint VP-25(I.D.ø32)<br />

7 Filter<br />

Model A B C D E<br />

P20,25,32 652 245 - 710 684<br />

P40 772 305 - 830 804<br />

P50 772 305 - 830 804<br />

P63,71,80 1012 280 290 1070 1044<br />

In case of rear inlet<br />

3.5<br />

21<br />

✻1<br />

✻2<br />

H<br />

F G<br />

6.35 12.7<br />

6.35 12.7<br />

6.35 ✻1 12.7<br />

9.52 ✻2 15.88<br />

9.52 15.88<br />

H(Liquid)<br />

17<br />

17<br />

✻1<br />

✻2<br />

450<br />

H(Gas)<br />

27<br />

27<br />

22 ✻1 29<br />

22 ✻2 29<br />

22 29<br />

50˜150 29<br />

30 640 30<br />

44 75<br />

4<br />

61 227 10<br />

243<br />

10<br />

1 2 6<br />

35<br />

13<br />

81<br />

A<br />

E 13<br />

10<br />

24<br />

Service space:500mm or more<br />

450<br />

Access door<br />

365˜465<br />

159<br />

18<br />

197<br />

55<br />

81<br />

A<br />

C B 81<br />

C<br />

D<br />

B<br />

81<br />

10-ø3(P20/25/32/40/50)<br />

12-ø3(P63/71/80)<br />

10<br />

10<br />

30<br />

Lifting bolt hole<br />

355<br />

56<br />

(14X22)<br />

10-ø3(P20/25/32/40/50)<br />

12-ø3(P63/71/80)<br />

Air inlet<br />

7<br />

288<br />

256<br />

40<br />

176<br />

282<br />

109<br />

179<br />

Air outlet<br />

45 80<br />

277<br />

85<br />

5<br />

3.5<br />

Keep duct-work length 850mm or more.<br />

Be sure to apply the air filter (field supply) near the air inlet grille.<br />

3<br />

In case of bottom inlet<br />

7<br />

Air outlet<br />

10-ø3(P20/25/32/40/50)<br />

12-ø3(P63/71/80)<br />

15<br />

40<br />

176<br />

256<br />

Air inlet<br />

10<br />

81<br />

C<br />

A<br />

B<br />

81<br />

PEFY-P100,125,140VMM-E<br />

Note: 1. On this model, you would use flare nut packed<br />

with the Indoor Unit, when connnecting the<br />

Outdoor Unit for R407C, R22.<br />

2. In order to increase the strength<br />

of the flare nut, the size of some<br />

of them has been increased.<br />

H<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

Refrigerant piping flare connection<br />

(liquid ø9.52 copper tube):HP<br />

Refrigerant piping flare connection<br />

(gas ø15.88 copper tube):LP<br />

ø19.05<br />

Drain 25A (male screw)<br />

Electrical parts box<br />

Drain Pump (Option)<br />

Drain Pipe (Option)···Flexible joint VP25(I.D. ø32)<br />

Filter<br />

Model A B C D E<br />

P100·125 1252 360 370 1310 1284<br />

P140 1552 460 470 1610 1584<br />

In case of rear inlet<br />

Air inlet<br />

25<br />

3 319 3<br />

279<br />

181 40<br />

30<br />

Keep duct-work length 850mm or more.<br />

7<br />

282<br />

Set<br />

F(Liquid) F(Gas)<br />

22 36<br />

22 36<br />

680<br />

53 169<br />

Be sure to apply the air filter (field supply) near the air inlet grille.<br />

450<br />

30<br />

10<br />

35<br />

20<br />

140<br />

210<br />

Service space:500mm or more<br />

450<br />

50˜150 29<br />

Access door<br />

365˜465<br />

122<br />

113<br />

307<br />

45<br />

323<br />

308<br />

4 1 2<br />

6<br />

Air outlet<br />

44<br />

5<br />

197<br />

243<br />

3<br />

55<br />

10<br />

13<br />

75<br />

81<br />

81<br />

A<br />

C B 81<br />

C B 81<br />

A<br />

10<br />

10<br />

E 13<br />

D<br />

12-ø3<br />

30<br />

Lifting bolt hole<br />

(14X22)<br />

375<br />

80<br />

12-ø3<br />

In case of bottom inlet<br />

7<br />

282<br />

Air outlet<br />

12-ø3<br />

30<br />

15<br />

40 181<br />

279<br />

Air inlet<br />

10<br />

81<br />

C B 81<br />

A<br />

50


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P VMH-E<br />

Power source<br />

❇ 1<br />

❇ 1<br />

Cooling capacity<br />

❇ 2<br />

❇ 2<br />

❇ 1<br />

Heating capacity ❇ 1<br />

❇ 1<br />

Power consumption Cooling<br />

(50/60Hz) Heating<br />

Cooling<br />

Current<br />

Heating<br />

<strong>External</strong> finish<br />

Dimension H x W x D<br />

Net weight<br />

Heat exchanger<br />

Type<br />

Airflow rate<br />

Fan (Lo-Hi)<br />

<strong>External</strong> static 220V<br />

pressure ❇3 230, 240V<br />

Type<br />

Motor<br />

Output ❇ 4<br />

Air filter (option)<br />

Gas<br />

Refrigerant (Flare)<br />

pipe diameter Liquid<br />

(Flare)<br />

Drain pipe diameter<br />

Noise level (Lo-Hi) 220V<br />

❇ 5 230, 240V<br />

mm<br />

in.<br />

kg(lbs.)<br />

m 3 /min<br />

L/s<br />

cfm<br />

Pa<br />

Pa<br />

<strong>Specifications</strong><br />

PEFY-P40VMH-E PEFY-P50VMH-E PEFY-P63VMH-E PEFY-P71VMH-E PEFY-P80VMH-E PEFY-P100VMH-E PEFY-P125VMH-E PEFY-P140VMH-E<br />

~ 220-240V 50Hz /60Hz<br />

kW 4.5<br />

5.6<br />

7.1<br />

8.0<br />

9.0<br />

11.2<br />

14.0<br />

16.0<br />

BTU/h 15,400 19,100 24,200 27,300 30,700 38,200 47,800 54,600<br />

kW 4.7 5.8<br />

7.3 8.3<br />

9.3 11.6<br />

14.5 16.3<br />

kcal/h 4,000 5,000<br />

6,300<br />

7,100<br />

8,000 10,000 12,500 14,000<br />

kW 5.0<br />

6.3<br />

8.0<br />

9.0<br />

10.0<br />

12.5<br />

16.0<br />

18.0<br />

kcal/h 4,300 5,400 6,900 7,700<br />

8,600 10,800 13,800 15,500<br />

BTU/h 17,100 21,500 27,300 30,700 34,100 42,700 54,600 61,400<br />

kW<br />

0.19/0.23<br />

0.24/0.30 0.26/0.33 0.32/0.40<br />

0.48/0.58<br />

0.48/0.59<br />

kW<br />

0.19/0.23<br />

0.24/0.30 0.26/0.33 0.32/0.40<br />

0.48/0.58<br />

0.48/0.59<br />

A<br />

0.88/1.06<br />

1.12/1.38 1.20/1.51 1.47/1.83<br />

2.34/2.66<br />

2.35/2.70<br />

A<br />

0.88/1.06<br />

1.12/1.38<br />

2.34/2.66<br />

2.35/2.70<br />

kW<br />

mm(in.)<br />

mm(in.)<br />

dB(A)<br />

dB(A)<br />

1.20/1.51 1.47/1.83<br />

Galvanizing<br />

380 x 750 x 900<br />

15" x 29-9/16" x 35-7/16"<br />

380 x 1,000 x 900<br />

15" x 39-3/8" x 35-7/16"<br />

380 x 1,200 x 900<br />

15" x 47-1/4" x 35-7/16"<br />

44(98)<br />

45(100)<br />

50(111)<br />

70(155)<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Sirocco fan✕ 1<br />

Sirocco fan✕ 2<br />

10.0-14.0<br />

13.5-19.0 15.5-22.0 18.0-25.0<br />

26.5-38.0<br />

28.0-40.0<br />

167-233<br />

225-317 258-367 300-417<br />

442-633<br />

467-667<br />

353-494<br />

477-671 547-777 636-883<br />

936-1342<br />

989-1413<br />

50/100/200<br />

100/150/200<br />

Single phase induction motor<br />

0.08<br />

0.12 0.14<br />

0.18<br />

0.26<br />

Synthethic fiber unwoven cloth filter(long life)<br />

ø 12.7 (1/2")<br />

ø 12.7 (1/2") [R410A]<br />

15.88(5/8")<br />

ø 15.88 (5/8") [R410A]<br />

ø 15.88 (5/8") [R22,R407C]<br />

ø<br />

ø 19.05 (3/4") [R22,R407C]<br />

ø 6.35 (1/4")<br />

ø 6.35(1/4") [R410A]<br />

ø 9.52 (3/8")[R22,R407C]<br />

ø 9.52(3/8")<br />

32 (1-1/4 inch)<br />

32 (1-1/4 inch)<br />

27-34<br />

32-38<br />

32-39<br />

35-41<br />

34-42<br />

31-37<br />

36-41<br />

35-41<br />

38-43<br />

38-44<br />

Note: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F))<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F))<br />

❇3 The external static pressure is set to 100Pa (at 220V) /150Pa (at 230, 240V) at factory shipment.<br />

❇4 The value are that at 240V.<br />

❇5 It is measured in anechoic room.<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P40,50,63,71,80, 100,125,140VMH-E<br />

Unit : mm<br />

G-ø3<br />

J-ø3<br />

D<br />

C<br />

70<br />

50x(G-1)=H<br />

F<br />

41<br />

Air inlet<br />

10<br />

Air outlet<br />

15<br />

50<br />

80 50 50x(J-1)=K<br />

B (Lifting bolt pitch)<br />

A<br />

E<br />

Less than 550 mm<br />

Less than 300mm 170mm±5mm<br />

(Actual length)<br />

3<br />

Model:40~80 (Note3)<br />

340<br />

Lifting bolt 383<br />

814 (Lifting bolt pitch)<br />

904<br />

900<br />

3<br />

60<br />

23<br />

250<br />

When installing the drain water lifting-up mech(option).<br />

51<br />

340<br />

45 50x5=250<br />

50<br />

24<br />

847<br />

10<br />

Drain hole<br />

Control box<br />

(option)<br />

2<br />

Terminal bed<br />

1<br />

(Power source)<br />

92<br />

Terminal box Terminal bed<br />

(Transmission)<br />

Keep duct-work length 850mm or more.<br />

Drain hole<br />

17<br />

30<br />

200<br />

343<br />

387<br />

29<br />

15<br />

41 25 50 50 50 50<br />

130 77<br />

328<br />

94<br />

250<br />

380<br />

Model A B C D E<br />

P40VMH-E 800 754 680 600 550<br />

P50VMH-E 800 754 680 600 550<br />

P63VMH-E 800 754 680 600 550<br />

P71·80VMH-E 1050 1004 930 850 800<br />

P100·125<br />

1250 1204 1130 1050 1000<br />

·140VMH-E<br />

F<br />

50<br />

50<br />

50<br />

25<br />

25<br />

G<br />

11<br />

11<br />

11<br />

17<br />

21<br />

✻1 ø12.7 ✻1 ø6.35<br />

780<br />

✻2 ø15.88 ✻2 ø9.52<br />

780 ø15.88 ø9.52<br />

1030 ø15.88 ø9.52<br />

✻1 ø15.88 ✻1 ø9.52<br />

1230<br />

✻2 ø19.05 ✻2 ø9.52<br />

✻1 22 ✻1 29<br />

✻2 22 ✻2 29<br />

22 29<br />

22 29<br />

✻1 22 ✻1 36<br />

✻2 22 ✻2 36<br />

✻1:R410A outdoor unit<br />

✻2:R407C,R22 outdoor unit<br />

Note : 1. Use M10 screw for the lifting bolt (field supply).<br />

2. Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned.<br />

3. This chart indicates for PEFY-P100·125·140VMH-E models, which have 2 fans.<br />

PEFY-P40·50·63·71·80 models have 1 fan.<br />

4. Make sure to install the air filter(field supply) on the air intake side.<br />

In case field supplied air filter is used, attach it where the filter service is easily done.<br />

5.On Model :50, 100, 125, 140, you would use flare nut packed with the Indoor Unit,<br />

when connnecting the Outdoor Unit for R407C, R22.<br />

6.In order to increase the strength of the flare nut, the size of some of them has been increased.<br />

P<br />

Refrigerant piping flare connection (gas M copper tube) : LP ··· ➀<br />

Refrigerant piping flare connection (liquid N copper tube) : HP ··· ➁<br />

Drain hose 32mm(1-1/4inch) (accessory) ··· ➂<br />

H<br />

500<br />

500<br />

500<br />

800<br />

1000<br />

J<br />

10<br />

10<br />

10<br />

15<br />

19<br />

K<br />

450<br />

450<br />

450<br />

700<br />

900<br />

L<br />

780<br />

M<br />

ø12.7<br />

N<br />

ø6.35<br />

P(Liquid)<br />

17<br />

P(Gas)<br />

27


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P VMH-E<br />

<strong>Specifications</strong><br />

PEFY-P200VMH-E<br />

PEFY-P250VMH-E<br />

Power source<br />

3N ~ 380-415V 50Hz / 60Hz<br />

❇ 1 kW<br />

22.4<br />

28.0<br />

Cooling capacity<br />

❇ 1 BTU/h<br />

76,400<br />

95,500<br />

❇ 2 kW<br />

23.3<br />

29.1<br />

❇ 2 kcal/h<br />

20,000<br />

25,000<br />

❇ 1 kW<br />

25.0<br />

31.5<br />

Heating capacity<br />

❇ 1 kcal/h<br />

21,500<br />

27,100<br />

❇ 1 BTU/h<br />

85,300<br />

107,500<br />

Power consumption Cooling<br />

kW<br />

0.99/1.14<br />

1.23/1.41<br />

(50/60Hz)<br />

Heating<br />

kW<br />

0.99/1.14<br />

1.23/1.41<br />

Cooling<br />

A<br />

1.62/1.86<br />

2.0/2.3<br />

Current<br />

Heating<br />

A<br />

1.62/1.86<br />

2.0/2.3<br />

<strong>External</strong> finish<br />

Dimension H x W x D mm(in.)<br />

Galvanizing<br />

470 x 1,250 x 1,120 (18-9/ 16 " x 49-1/ 4 " x 44-1/ 8 ")<br />

Net weight<br />

kg(lbs.)<br />

100 (221)<br />

Heat exchanger<br />

Type<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Sirocco fan ✕ 2<br />

m 3 /min<br />

58.0<br />

72.0<br />

Fan<br />

Airflow rate<br />

L/s<br />

967<br />

1200<br />

cfm<br />

2048<br />

2543<br />

<strong>External</strong> static 380V<br />

Pa<br />

110/220<br />

pressure ❇ 5 400, 415V Pa<br />

130/260<br />

Motor<br />

Type<br />

3-phase induction motor<br />

Output<br />

❇6 kW<br />

0.76<br />

1.08<br />

Air filter (option)<br />

Synthethic fiber unwoven cloth filter(long life)<br />

Gas<br />

mm(in.)<br />

ø 19.05 (3/ 4 ") [R410A]<br />

ø 22.2 (7/ 8 ") [R410A]<br />

Refrigerant<br />

(Brazing)<br />

ø 25.4 (1") [R22,R407C]<br />

ø 28.58 (1-1/ 8 ") [R22,R407C]<br />

pipe diameter<br />

Liquid mm(in.)<br />

ø 9.52 (3/ 8 ") (R410A)<br />

(Brazing)<br />

ø 12.7 (1/ 2 ") (R22,R407C)<br />

Drain pipe diameter<br />

32 (1-1/4 inch)<br />

380V<br />

Noise level<br />

dB(A)<br />

42(110Pa)/45(220Pa)<br />

50(110Pa)/52(220Pa)<br />

❇ 7<br />

400, 415V dB(A)<br />

44(130Pa)/47(260Pa)<br />

52(130Pa)/54(260Pa)<br />

Note: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. ❇3 The external static pressure is set to 100Pa (at 220V) /150Pa (at 230, 240V) at factory shipment.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F))<br />

❇4 The value are that at 240V.<br />

❇5 The external static pressure is set to 110Pa (at 380V) /130Pa (at 400, 415V) at factory shipment.<br />

❇6 The value are that at 415V.<br />

❇7 It is measured in anechoic room.<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F))<br />

PEFY-P200, 250VMH-E<br />

<strong>External</strong> <strong>Dimensions</strong><br />

Unit : mm<br />

1100<br />

420<br />

1250<br />

102 25<br />

50x21=1050<br />

Lifting bolt<br />

22-ø3<br />

Air inlet<br />

10<br />

21-ø3<br />

Air outlet<br />

15<br />

3<br />

100 50<br />

50x20=1000<br />

23 1326 (Lifting bolt pitch)<br />

1372<br />

1034 (Lifting bolt pitch) 60 340<br />

1124<br />

1100<br />

Note : 1. Use M10 screw for the lifting bolt<br />

(field supply).<br />

2. Keep the service space for the<br />

maintenance from the bottom when<br />

the heat exchanger is cleaned.<br />

3. Make sure to install the air filter(field<br />

supply)on the air intake side.<br />

In case field supplied air filter is<br />

used, attach it where the filter<br />

service is easily done.<br />

4.On this model, you would use pipe<br />

packed with the Indoor Unit, when<br />

connnecting the Outdoor Unit for<br />

R407C, R22.<br />

Model A B<br />

P200VMH-E<br />

P250VMH-E<br />

✻1<br />

✻2<br />

✻1<br />

✻2<br />

ø19.05<br />

ø25.4<br />

ø22.2<br />

ø28.58<br />

✻1<br />

✻2<br />

✻1<br />

✻2<br />

ø9.52<br />

ø12.7<br />

ø9.52<br />

ø12.7<br />

✻1:R410A outdoor unit<br />

✻2:R407C,R22 outdoor unit<br />

Refrigerant piping brazing connection<br />

(gas A copper tube) : LP ····➀<br />

Refrigerant piping brazing connection<br />

(liquid B copper tube) : HP ····➁<br />

Drain hose 32mm(1-1/4inch)<br />

(accessory) ····➂<br />

1120<br />

24<br />

10<br />

1067<br />

Drain hole<br />

(option)<br />

29<br />

15<br />

Control box<br />

20<br />

420<br />

35 50x7= 350<br />

Keep duct-work length 850mm or more.<br />

Terminal bed<br />

(Power source)<br />

Terminal bed<br />

(Transmission)<br />

Drain hole<br />

30<br />

2 1<br />

95 249<br />

422<br />

489<br />

41<br />

164<br />

44<br />

327<br />

20 50x6= 300<br />

105<br />

340<br />

470<br />

Less than 550mm<br />

Less than 300mm<br />

170mm±5mm<br />

(Actual Length)<br />

3<br />

When installing the drain water lifting-up mech(option).<br />

52


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PCFY-P VGM-E<br />

mm(in.)<br />

mm(in.)<br />

<strong>Specifications</strong><br />

PCFY-P40VGM-E PCFY-P63VGM-E PCFY-P100VGM-E PCFY-P125VGM-E<br />

Power source<br />

~ 220-240V 50Hz / ~220V 60Hz<br />

❇ 1 kW<br />

4.5<br />

7.1<br />

11.2<br />

14.0<br />

Cooling capacity<br />

❇ 1 BTU/h<br />

15,400<br />

24,200<br />

38,200<br />

47,800<br />

❇ 2 kW<br />

4.7<br />

7.3 11.6<br />

14.5<br />

❇ 2 kcal/h<br />

4,000<br />

6,300<br />

10,000<br />

12,500<br />

❇ 1 kW<br />

5.0<br />

8.0<br />

12.5<br />

16.0<br />

Heating capacity<br />

❇ 1 kcal/h<br />

4,300<br />

6,900<br />

10,800<br />

13,800<br />

❇ 1 BTU/h<br />

17,100<br />

27,300<br />

42,700<br />

54,600<br />

Power<br />

Cooling kW<br />

0.10<br />

0.13<br />

0.16<br />

0.24<br />

consumption<br />

Heating kW<br />

0.10<br />

0.13<br />

0.16<br />

0.24<br />

Current<br />

<strong>External</strong> finish(Munsel No.)<br />

0.70Y 8.59/0.97<br />

Cooling<br />

A<br />

0.46<br />

0.60<br />

0.73<br />

1.10<br />

Heating<br />

A<br />

0.46<br />

0.60<br />

0.73<br />

1.10<br />

Dimension H x W x D mm 210 x 1,000 x 680 210 x 1,310 x 680 270 x 1,310 x 680 270 x 1,620 x 680<br />

in. 8- 5 / 16 " x 39- 3 / 8 " x 26- 13 / 16 " 8- 5 / 16 " x 51- 5 / 8 " x 26- 13 / 16 " 10- 11 / 16 " x 51- 5 / 8 " x 26- 13 / 16 " 10- 11 / 16 " x 63- 13 / 16 " x 26- 13 / 16 "<br />

Net weight<br />

kg(lbs.)<br />

27(60)<br />

34(75)<br />

37(82)<br />

43(95)<br />

Heat exchanger<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Type<br />

Sirocco fan✕ 2 Sirocco fan✕ 3 Sirocco fan✕ 4<br />

Fan<br />

❇3 m 3 /min 8-10-11-12 12-14-16-18 18-20-23-25 26-28-32-35<br />

Airflow rate<br />

(Lo-Mid2-Mid1-Hi)<br />

L/s 133-167-183-200 200-233-267-300 300-333-383-417 433-467-533-583<br />

cfm 253-353-388-424 424-494-565-636 636-706-812-883 918-989-1130-1236<br />

<strong>External</strong> staticpressure<br />

Pa<br />

0<br />

Motor<br />

Type<br />

Single phase induction motor<br />

Output<br />

kW<br />

0.054<br />

0.070<br />

0.090<br />

0.150<br />

Air filter<br />

Refrigerant<br />

pipe diameter<br />

Gas(Flare)<br />

Liquid(Flare)<br />

Drain pipe diameter<br />

Noise level (Lo-Mid2-Mid1-Hi) ❇3 ❇4<br />

Note:<br />

dB(A)<br />

ø 12.7( 1 / 2 ")<br />

ø 6.35( 1 / 4 ")<br />

29-33-36-38<br />

❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C (80˚F))<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C (68˚F))<br />

❇3 airflw rate/noise level are shown in (low-middle 2-middle 1-high).<br />

❇4 It is measured in anechoic room.<br />

PP Honeycomb (long life)<br />

ø15.88( 5 / 8 ") ø 15.88( 5 / 8 ") / ø 19.05( 3 / 4 ") (Compatible)<br />

ø 9.52( 3 / 8 ")<br />

I.D. ø26 (VP-25)<br />

32-34-37-39<br />

36-38-41-43<br />

37-39-42-44<br />

PCFY-P40,63,100,125VGM-E<br />

<strong>External</strong> <strong>Dimensions</strong><br />

Unit : mm<br />

150 18<br />

140 70<br />

80<br />

320<br />

Model Liquid Gas<br />

40 ø6.35 ø12.7<br />

63 ø9.52 ø15.88<br />

100,125 ø9.52<br />

ø15.88(R410A)<br />

ø 19.05(R407C,R22)<br />

E<br />

(Suspension bolt pitch)<br />

Electrical box<br />

70<br />

D<br />

16<br />

87<br />

229<br />

Air outlet<br />

506 56<br />

680<br />

81 96<br />

G<br />

F<br />

H<br />

B<br />

A<br />

182<br />

I<br />

J<br />

High press.<br />

Low press.<br />

(Drainage)<br />

254<br />

Air intake<br />

C<br />

161<br />

90<br />

Model A B C D E F G H I J<br />

PCFY -P40VGM-E 1,000 904 918 983 933 210 180 157 201 241<br />

PCFY -P63VGM-E 1,310 1,214 1,228 1,290 1,240 210 180 157 201 241<br />

PCFY -P100VGM-E 1,310 1,214 1,228 1,290 1,240 270 207 217 198 245<br />

PCFY -P125VGM-E 1,620 1,524 1,535 1,600 1,547 270 207 217 198 245<br />

53


MITSUBISHI<br />

PKFY-VAM<br />

MITSUBISHI ELECTRIC<br />

INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PKFY-P VAM-E<br />

PKFY-P VGM-E<br />

<strong>Specifications</strong><br />

PKFY-P20VAM-E PKFY-P25VAM-E PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E<br />

Power source<br />

~ 220-240V 50Hz ~ 220V 60Hz<br />

❇ 1 kW<br />

2.2 2.8 3.6 4.5<br />

5.6<br />

Cooling capacity<br />

❇ 1 BTU/h<br />

7,500 9,600 12,300<br />

15,400 19,100<br />

❇ 2 kW<br />

2.3 2.9 3.7<br />

4.7<br />

5.8<br />

❇ 2 kcal/h<br />

2,000 2,500 3,150 4,000<br />

5,000<br />

❇ 1 kW<br />

2.5 3.2 4.0 5.0<br />

6.3<br />

Heating capacity<br />

❇ 1 kcal/h<br />

2,200 2,800 3,400<br />

4,300 5,400<br />

❇ 1 BTU/h<br />

8,500 10,900 13,600<br />

17,100 21,500<br />

Power<br />

Cooling kW<br />

0.04<br />

0.07<br />

consumption Heating kW<br />

0.04<br />

0.07<br />

Current<br />

Cooling A<br />

0.20<br />

0.32<br />

Heating A<br />

0.20<br />

0.32<br />

<strong>External</strong> finish(Munsel<br />

Dimension H x W x D<br />

No.)<br />

mm(in.) 295 x 815 x 158 (11-5/ 8 " x 32-1/ 8 " x 6-1/ 4 ")<br />

Plastic 2.60Y 8.66/0.69<br />

Plastic 0.70Y 8.59/0.97<br />

340 x 990 x 235 (13-7/ 16 " x 39" x 6-5/ 16 ")<br />

white<br />

Net weight<br />

kg(lbs.)<br />

8.5(19)<br />

16(36)<br />

Heat exchanger<br />

Type<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Line flow fan ✕ 1<br />

Fan<br />

❇ 3 m 3 /min<br />

Airflow rate<br />

4.9-5.2-5.6-5.9<br />

8-9.5-10.5-11.5<br />

9-10-11-12<br />

(Lo-Mid2-Mid1-Hi)<br />

L/s<br />

82-87-93-98<br />

133-158-175-192<br />

150-167-183-200<br />

cfm<br />

173-184-198-208<br />

283-335-371-406<br />

318-353-388-424<br />

<strong>External</strong> static pressure Pa<br />

0<br />

Motor<br />

Type<br />

Single phase induction motor<br />

Output<br />

kW<br />

0.017<br />

0.030<br />

Air filter<br />

PP Honeycomb (long life)<br />

Gas<br />

mm(in.)<br />

ø 12.7(1/2")<br />

ø 12.7(1/ 2 ") / ø 15.88(5/ 8 ")<br />

Refrigerant<br />

(Flare)<br />

(Compatible)<br />

pipe diameter Liquid<br />

mm(in.)<br />

ø 6.35(1/4")<br />

ø 6.35(1/4") / ø 9.52(3/8")<br />

(Flare)<br />

(Compatible)<br />

Drain pipe diameter<br />

I.D. ø16 (VP-16)<br />

I.D. ø20 (VP-20)<br />

Noise level (Lo-Mid2-Mid1-Hi) ❇3 ❇4 dB(A)<br />

32-33-35-36<br />

33-36-38-41<br />

34-37-40-43<br />

Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇ 2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F))<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F))<br />

❇ 3 Airflow rate/noise level are in (low-middle2-middle1-high).<br />

❇ 4 It is measured in anechoic room.<br />

<strong>External</strong> <strong>Dimensions</strong><br />

295<br />

PKFY-P20, 25VAM-E<br />

783<br />

815<br />

21.5 247.5 Intake dimensions<br />

2.5 60 150<br />

13<br />

630 Intake dimensions 146<br />

695 Outlet dimensions<br />

60<br />

13 25.5<br />

Intake dimensions<br />

Remote control<br />

terminal plate<br />

Power terminal plate<br />

Adress board<br />

PKFY-P32,40,50VGM-E<br />

70 21 245<br />

Left side<br />

60<br />

Knock out hole for<br />

left piping<br />

Refrigerant pipe.<br />

Drain pipe.Wiring hole.<br />

340<br />

53<br />

79<br />

Front view<br />

Lower side<br />

12-Louvers (manual)<br />

715 Air intake<br />

225<br />

340 Air intake 80 280 Air intake<br />

233<br />

990<br />

Auto vane<br />

705 Air outlet<br />

235<br />

160 40<br />

Air intake<br />

198<br />

Right side<br />

235<br />

70 21 245<br />

Address board<br />

Knock out hole for under piping<br />

Refrigerant piping.Drain pipe.<br />

Wiring hole<br />

60<br />

Less than 15<br />

Unit : mm<br />

Knock out hole for<br />

right piping<br />

Refrigerant pipe.<br />

Drain pipe.<br />

Wiring hole<br />

660 (Total length of drain piping 760) 110<br />

80<br />

60<br />

450 Gas pipe<br />

520 Liquid pipe<br />

116<br />

50<br />

400<br />

395<br />

190<br />

70 35<br />

Outlet<br />

angle<br />

Intake<br />

direction<br />

17˚<br />

37.4<br />

Outlet<br />

direction<br />

The address board is protected by<br />

a plastic cover.<br />

Remove the cover with a screwdriver<br />

(one screw) to set the board.<br />

158<br />

5<br />

Installation board<br />

Liquid pipe ø6.35<br />

Gas pipe ø12.7<br />

70.3<br />

Address board<br />

Outlet<br />

dimensions Terminal plate<br />

Rotary switch (pair No.)<br />

Rotary switch (own address)<br />

(Left side piping<br />

35 installation)<br />

Drain pipe (O.D. ø20)<br />

Front view(to open the grille)<br />

Filter grip<br />

Liquid pipe<br />

Gas pipe<br />

700 (Flexible hose total length 800)<br />

153<br />

Model<br />

32,40<br />

50<br />

481 54<br />

549 86<br />

Service panel<br />

(Power supply access)<br />

Terminal block for<br />

remote control<br />

Terminal block for<br />

power supply<br />

(Right side piping<br />

installation)<br />

Liquid pipe Gas pipe<br />

ø6.35 ø12.7<br />

ø 6.35(R410A) ø 12.7(R410A)<br />

ø9.52(R407C,R22) ø15.88(R407C,R22)<br />

31 280<br />

Dip switch (switches functions)<br />

54


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PKFY-P VFM-E<br />

Power source<br />

Cooling capacity<br />

❇ 1<br />

❇ 1<br />

kW<br />

BTU/h<br />

❇ 2 kcal/h<br />

Heating capacity<br />

❇ 1 kW<br />

❇ 1 BTU/h<br />

Power<br />

Cooling kW<br />

consumption Heating kW<br />

Current<br />

Cooling A<br />

Heating A<br />

<strong>External</strong> finish(Munsel No.)<br />

Dimension<br />

Net weight<br />

Height<br />

Width<br />

Depth<br />

mm(in.)<br />

mm(in.)<br />

mm(in.)<br />

kg(lbs.)<br />

Heat exchanger<br />

Type<br />

Airflow rate ❇ 3<br />

Fan (Lo-Hi)<br />

<strong>External</strong> static pressure<br />

m 3 /min<br />

Pa<br />

Motor<br />

Air filter<br />

Type<br />

Output<br />

Refrigerant<br />

pipe diameter<br />

Gas<br />

(Flare)<br />

Liquid<br />

(Flare)<br />

kW<br />

mm(in.)<br />

mm(in.)<br />

<strong>Specifications</strong><br />

PKFY-P63VFM-E<br />

7.1<br />

24,200<br />

6,300<br />

8.0<br />

27,300<br />

0.12<br />

0.12<br />

0.55<br />

0.55<br />

340(13- 3 /8)<br />

1,400(55- 1 /8)<br />

235(9- 1 /4)<br />

24(53)<br />

Drain pipe diameter<br />

I.D. ø20 (VP-20)<br />

Noise level (Lo-Hi) ❇3 ❇4 dB(A)<br />

39-45<br />

Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition.<br />

❇1 Cooling Indoor: 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB, Outdoor: 35˚C(95˚F)DB<br />

Heating Indoor: 20˚C(68˚F)DB, Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇2 Cooling Indoor: 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB, Outdoor: 35˚C(95˚F)DB<br />

❇3 Airflow rate/noise level are in (low-high).<br />

❇4 It is measured in anechoic room.<br />

15-20<br />

0.040<br />

ø15.88( 5 /8)<br />

<strong>External</strong> <strong>Dimensions</strong><br />

220-230-240V 50Hz / 220V 60Hz<br />

Plastic, white : <br />

Cross fin (Aluminum plate fin and copper tube)<br />

Line flow fan ✕ 2<br />

0<br />

Single phase induction motor<br />

PP Honeycomb (antibacterial)<br />

ø9.52( 3 /8)<br />

PKFY-P100VFM-E<br />

11.2<br />

38,200<br />

10,000<br />

12.5<br />

42,700<br />

0.14<br />

0.14<br />

0.64<br />

0.64<br />

340(13- 3 /8)<br />

1,680(66- 1 /8)<br />

235(9- 1 /4)<br />

28(62)<br />

Top<br />

PKFY-P63VFM-E PKFY-P100VFM-E Unit : mm<br />

235 45 235 45 235 45<br />

235<br />

13 62.5<br />

235 45 235 45 235 45<br />

22-28<br />

0.070<br />

ø15.88( 5 /8) / ø19.05( 3 /4)<br />

235<br />

41-46<br />

45<br />

235<br />

62.5<br />

13<br />

Left side<br />

1400<br />

1090 Air intake<br />

235<br />

Left side<br />

Front<br />

1680<br />

1370 (Air intake)<br />

Knock out hole<br />

for right piping<br />

Right side<br />

235<br />

A<br />

340<br />

197<br />

C<br />

A<br />

340<br />

197<br />

C<br />

Knock out hole<br />

for left piping<br />

2<br />

42<br />

58<br />

Less than 15<br />

Bolt<br />

Knock out hole<br />

for left piping<br />

2<br />

42<br />

58<br />

Less than 15<br />

Bolt<br />

Drain hose for<br />

left-hand side piping<br />

25<br />

Drain hose<br />

Drain hose 1<br />

55(Gas pipe)<br />

107<br />

120(Liquid pipe)<br />

111<br />

1110 (Drain hose)<br />

183<br />

Lower side louvers(manual)<br />

Auto vanes<br />

1120<br />

240<br />

552Air outlet<br />

552Air outlet<br />

25<br />

Drain hose for<br />

left-hand side piping<br />

Drain hose 1<br />

1110 (Drain hose)<br />

Lower side<br />

1400<br />

694 Air outlet<br />

694 Air outlet<br />

55 (Gas pipe)<br />

120(Liquid pipe) 102<br />

183<br />

111<br />

240<br />

Under panel(Removable at<br />

left-hand side piping)<br />

Knock out hole for under-piping<br />

Refrigerant pipe .Drain pipe<br />

B<br />

louvers(manual) B<br />

Under panel(Removable at<br />

left-hand side piping)<br />

Auto vanes<br />

Knock out hole for under-piping<br />

Refrigerant pipe .Drain pipe<br />

Knock out hole for wiring<br />

B C<br />

A<br />

30<br />

30<br />

Knock out hole for wiring<br />

A<br />

B<br />

C<br />

30 30<br />

55<br />

100<br />

4 39<br />

37<br />

74<br />

Wall fixture<br />

66-ø6 hole<br />

for tapping<br />

screw<br />

32-ø12 hole<br />

for bolt<br />

37<br />

65<br />

39<br />

100<br />

39<br />

98 32 74 37<br />

Drainage range on<br />

left hand side<br />

Drainage range on<br />

Unit center<br />

right-hand side<br />

990<br />

245<br />

455<br />

10X91=(910) 285<br />

900<br />

19<br />

18 18<br />

91<br />

4<br />

184 10<br />

30 30<br />

80 29<br />

60 280<br />

225 240 180 280 314<br />

610 90 Rear piping hole<br />

12-ø6 hole<br />

for tapping screw Range for left rear piping hole<br />

30<br />

100<br />

4 39<br />

37<br />

74<br />

Unit out line<br />

Wall fixture<br />

84-ø6 hole 18 18<br />

for tapping<br />

screw<br />

41-ø12 hole<br />

for bolt<br />

Drainage range on<br />

left hand side<br />

Range for left rear piping hole<br />

39<br />

98<br />

295 225<br />

32<br />

65<br />

37<br />

74 37<br />

Unit center<br />

1270<br />

13X91=(1183)<br />

39<br />

100<br />

4<br />

900<br />

Drainage range on<br />

right-hand side<br />

595<br />

91<br />

245<br />

285<br />

19<br />

10<br />

30<br />

29<br />

30 184<br />

30<br />

80<br />

60 280<br />

240 180 280 314<br />

750<br />

90 Rear piping hole<br />

12-ø6 hole<br />

for tapping screw<br />

Range for left rear piping hole


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

New<br />

PFFY-P VKM-E<br />

<strong>Specifications</strong><br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

Power<br />

consumption<br />

Current<br />

Dimension<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Height<br />

Width<br />

Depth<br />

❇1<br />

❇1<br />

kW<br />

kW<br />

kW<br />

kW<br />

A<br />

A<br />

mm<br />

mm<br />

mm<br />

PFFY-P20VKM-E<br />

2.2<br />

2.5<br />

0.025<br />

0.025<br />

0.20<br />

0.20<br />

600<br />

700<br />

200<br />

PFFY-P25VKM-E PFFY-P32VKM-E<br />

1-phase 220-240V 50Hz<br />

2.8<br />

3.6<br />

3.2<br />

4.0<br />

0.025<br />

0.025<br />

0.025<br />

0.025<br />

0.20<br />

0.20<br />

0.20<br />

0.20<br />

600<br />

600<br />

700<br />

700<br />

200<br />

200<br />

PFFY-P40VKM-E<br />

4.5<br />

5.0<br />

0.028<br />

0.028<br />

0.24<br />

0.24<br />

600<br />

700<br />

200<br />

Weight<br />

kg<br />

15<br />

15<br />

15<br />

15<br />

Heat exchanger<br />

Type<br />

Airflow rate<br />

Fan (Low-Mid-High-SHi)<br />

<strong>External</strong> static<br />

pressure<br />

❇2<br />

m 3 /min<br />

Pa<br />

5.9-6.8-7.6-8.7<br />

Cross fin (Alminium plate fin and copper tube)<br />

Line flow fan ✕ 2<br />

6.1-7.0-8.0-9.1<br />

6.1-7.0-8.0-9.1<br />

0<br />

8.0-9.0-9.5-10.7<br />

Motor Type<br />

Output<br />

Air filter<br />

Refrigerant<br />

Gas(Flare)<br />

pipe diameter<br />

Liquid(Flare)<br />

Noise level(Low-Mid-High-SHi) ❇2 ❇3<br />

kW<br />

mm<br />

mm<br />

dB(A)<br />

27-31-34-37<br />

DC motor<br />

0.03 ✕ 2<br />

PP honeycomb fabric (Catechin Filter)<br />

12.7<br />

6.35<br />

28-32-35-38<br />

28-32-35-38<br />

35-38-42-44<br />

Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition.<br />

❇1 Cooling Indoor: 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB, Outdoor: 35˚C(95˚F)DB<br />

Heating Indoor: 20˚C(68˚F)DB, Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇2 Airflow rate/noise level are in (Low-Mid-High-SHi).<br />

❇3 It is measured in anechoic room.<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PFFY-P20,25,32,40VKM-E<br />

Unit : mm<br />

4- 6 Hole<br />

131 131<br />

7<br />

Installation plate<br />

46.5<br />

More than<br />

100mm<br />

700<br />

607<br />

46.5<br />

12 200<br />

Air out<br />

Indoor unit<br />

12<br />

363<br />

210 333<br />

593<br />

More than<br />

100mm<br />

More than<br />

100mm<br />

600<br />

Air in<br />

118<br />

96<br />

Gas pipe<br />

12.7(flared)1/2<br />

Liquid pipe<br />

6.35(flared)1/4<br />

337<br />

337<br />

11<br />

Air out<br />

125<br />

60<br />

19<br />

12<br />

60<br />

54<br />

508<br />

137<br />

110<br />

45<br />

35<br />

123<br />

drain<br />

12<br />

60<br />

128<br />

60<br />

19 60<br />

125<br />

165<br />

72<br />

147<br />

205<br />

155 454<br />

60<br />

80<br />

56


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PFFY-P VLEM-E<br />

PFFY-P VLRM-E<br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

kW<br />

BTU/h<br />

kW<br />

kcal/h<br />

kW<br />

kcal/h<br />

BTU/h<br />

kW<br />

<strong>Specifications</strong><br />

PFFY-P20VLEM-E PFFY-P25VLEM-E PFFY-P32VLEM-E PFFY-P40VLEM-E PFFY-P50VLEM-E PFFY-P63VLEM-E<br />

~ 220-240V 50Hz / ~ 208-230V 60Hz<br />

2.2<br />

2.8 3.6 4.5 5.6<br />

7.1<br />

7,500 9,600 12,300 15,400 19,100 24,200<br />

2.3 2.9 3.7<br />

4.7 5.8<br />

7.3<br />

2,000 2,500 3,150 4,000 5,000<br />

6,300<br />

2.5<br />

3.2 4.0 5.0 6.3<br />

8.0<br />

2,200 2,800 3,400<br />

4,300 5,400 6,900<br />

8,500 10,900 13,600 17,100 21,500 27,300<br />

❇ 1<br />

Power<br />

Cooling<br />

0.04 / 0.06<br />

0.06 / 0.07 0.065 / 0.075 0.085 / 0.09 0.1 / 0.11<br />

consumption Heating kW<br />

0.04 / 0.06<br />

0.06 / 0.07 0.065 / 0.075 0.085 / 0.09 0.1 / 0.11<br />

Current<br />

Cooling A<br />

0.19 / 0.25<br />

0.29 / 0.30 0.32 / 0.33 0.40 / 0.41 0.46 / 0.47<br />

Heating A<br />

0.19 / 0.25<br />

0.29 / 0.30 0.32 / 0.33 0.40 / 0.41 0.46 / 0.47<br />

<strong>External</strong> finish(Munsel No.)<br />

Acrylic paint (5Y 8/1)<br />

Dimension H x W x D mm<br />

630 x 1,050 x 220<br />

630 x 1,170 x 220 630 x 1,410 x 220<br />

Net weight<br />

in. 24-13/ 16 " x 41-3/ 8 " x 8-11/ 16 " 24-13/ 16 " x 46-1/ 8 " x 8-11/ 16 " 24-13/ 16 " x 55-9/ 16 " x 8-11/ 16 "<br />

kg(lbs.)<br />

23(51) 25(56) 26(58) 30(67) 32(71)<br />

Heat exchanger<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Type<br />

Sirocco fan✕ 1<br />

Sirocco fan✕ 2<br />

❇ 3 m 3 /min<br />

7.0-9.0 9.0-11.0 12.0-14.0 12.0-15.5<br />

Fan<br />

Airflow rate<br />

(Low-High)<br />

<strong>External</strong> static<br />

pressure<br />

Type<br />

Motor<br />

Output<br />

Air filter<br />

Refrigerant<br />

pipe diameter<br />

❇ 1<br />

❇ 1<br />

❇ 2<br />

❇ 2<br />

❇ 1<br />

❇ 1<br />

Gas<br />

(Flare)<br />

Liquid<br />

(Flare)<br />

Drain pipe diameter<br />

Noise level (Low-High) ❇3 ❇4 ❇5<br />

L/s<br />

cfm<br />

Pa<br />

kW<br />

mm(in.)<br />

mm(in.)<br />

dB(A)<br />

5.5-6.5<br />

92-108<br />

194-230<br />

117-150<br />

247-318<br />

150-183<br />

318-388<br />

200-233<br />

424-494<br />

Single phase induction motor<br />

0.015 0.018 0.030<br />

0.035<br />

PP Honeycomb fabric (washable)<br />

ø 12.7 (1/ 2 ")<br />

ø 12.7 (1/ 2 ") [R410A]<br />

ø 15.88 (5/ 8 ") [R22,R407C]<br />

ø 6.35 (1/ 4 ")<br />

ø 6.35 (1/ 4 ") [R410A]<br />

ø 9.52 (3/ 8 ") [R22,R407C]<br />

Accessary hose ø 27 (top end : ø 20)<br />

34-40 35-40 38-43<br />

0<br />

200-258<br />

424-547<br />

0.063<br />

ø 15.88 (5/ 8 ")<br />

ø 9.52 (3/ 8 ")<br />

40-46<br />

57<br />

PFFY-P20VLRM-E PFFY-P25VLRM-E PFFY-P32VLRM-E PFFY-P40VLRM-E PFFY-P50VLRM-E PFFY-P63VLRM-E<br />

Power source<br />

~ 220-240V 50Hz / ~ 208-230V 60Hz<br />

❇ 1 kW<br />

2.2<br />

2.8 3.6 4.5 5.6<br />

7.1<br />

Cooling capacity<br />

❇ 1 BTU/h 7,500 9,600 12,300 15,400 19,100 24,200<br />

❇ 2 kW<br />

2.3 2.9 3.7<br />

4.7 5.8<br />

7.3<br />

❇ 2<br />

❇ 1<br />

kcal/h<br />

kW<br />

2,000<br />

2.5<br />

2,500<br />

3.2<br />

3,150<br />

4.0<br />

4,000<br />

5.0<br />

5,000<br />

6.3<br />

6,300<br />

8.0<br />

Heating capacity ❇ 1 kcal/h 2,200 2,800 3,400<br />

4,300 5,400 6,900<br />

❇ 1 BTU/h 8,500 10,900 13,600 17,100 21,500 27,300<br />

Power<br />

Cooling kW<br />

0.04 / 0.06<br />

0.06 / 0.07 0.065 / 0.075 0.085 / 0.09 0.1 / 0.11<br />

consumption Heating kW<br />

0.04 / 0.06<br />

0.06 / 0.07 0.065 / 0.075 0.085 / 0.09 0.1 / 0.11<br />

Current<br />

Cooling A<br />

0.19 / 0.25<br />

0.29 / 0.30 0.32 / 0.33 0.40 / 0.41 0.46 / 0.47<br />

Heating A<br />

0.19 / 0.25<br />

0.29 / 0.30 0.32 / 0.33 0.40 / 0.41 0.46 / 0.47<br />

<strong>External</strong> finish(Munsel No.)<br />

Galvanizing<br />

Dimension H x W x D mm<br />

639 x 886 x 220<br />

639 x 1,006 x 220 639 x 1,246 x 220<br />

Net weight<br />

in. 25-3/ 16 " x 34-15/ 16 " x 8-11/ 16 " 25-3/ 16 " x 39-5/ 8 " x 8-11/ 16 " 25-3/ 16 " x 49-1/ 16 " x 8-11/ 16 "<br />

kg(lbs.)<br />

18.5(41) 20(45) 21(47) 25(56) 27(60)<br />

Heat exchanger<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Type<br />

Sirocco fan✕ 1<br />

Sirocco fan✕ 2<br />

❇ 3 m 3 /min<br />

5.5-6.5<br />

7.0-9.0 9.0-11.0 12.0-14.0 12.0-15.5<br />

Airflow rate<br />

Fan (Low-High)<br />

L/s<br />

92-108<br />

117-150 150-183 200-233 200-258<br />

cfm<br />

194-230<br />

247-318 318-388 424-494 424-547<br />

<strong>External</strong> static<br />

pressure<br />

Pa<br />

0<br />

Motor<br />

Type<br />

Single phase induction motor<br />

Output<br />

kW<br />

0.015 0.018 0.030 0.035<br />

0.063<br />

Air filter<br />

PP Honeycomb fabric (washable)<br />

mm(in.)<br />

ø 12.7 (1/ 2 ")<br />

ø 12.7 (1/ 2 ") [R410A]<br />

ø 15.88 (5/ 8 ")[R22,R407C]<br />

ø 15.88 (5/ 8 ")<br />

Refrigerant<br />

pipe diameter<br />

Gas<br />

(Flare)<br />

Liquid<br />

(Flare)<br />

Drain pipe diameter<br />

Noise level (Low-High) ❇3 ❇4 ❇5<br />

mm(in.)<br />

dB(A)<br />

ø 6.35 (1/ 4 ")<br />

ø 6.35 (1/ 4 ") [R410A]<br />

ø 9.52 (3/ 8 ") [R22,R407C]<br />

Accessary hose ø 27 (top end : ø 20)<br />

34-40 35-40 38-43<br />

Note: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB<br />

Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB<br />

❇2 Cooling capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F))<br />

Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F))<br />

❇ 3 Air flow rate/noise level are in ( Low-High)<br />

❇ 4 Measured point : 1m51m, Power supply : AC240V/50Hz<br />

·1dB(A) lower at AC230V/50Hz<br />

·2dB(A) lower at AC220V/50Hz<br />

·3dB(A) lower at 1.5m✕1.5m point<br />

❇ 5 It is measured in anechoic room.<br />

ø 9.52 (3/ 8 ")<br />

40-46


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PFFY-P VLEM-E<br />

PFFY-P VLRM-E<br />

<strong>External</strong> <strong>Dimensions</strong><br />

PFFY-P20,25,32,40,50,63VLEM-E<br />

Note: 1. On Model :50, you would use flare nut<br />

packed with the Indoor Unit, when<br />

connnecting the Outdoor Unit for R407C,<br />

R22.<br />

2. In order to increase the strength of the flare<br />

nut, the size of some of them has been<br />

G<br />

(60)<br />

40 120<br />

Air supply grille<br />

Unit : mm<br />

Remote controller<br />

can be built-in.<br />

(Program timer can not be<br />

built-in together)<br />

Air outlet<br />

C<br />

A<br />

220<br />

80<br />

B<br />

170<br />

50<br />

100<br />

35<br />

35<br />

20<br />

Refrigerant piping flare<br />

connection(Gas) E : LP<br />

Refrigeant piping flare<br />

connection(Liquid) F : HP<br />

Drain pan<br />

Strainer<br />

78<br />

15<br />

15<br />

160<br />

310 108<br />

2 ✕ 2-12 ✕16<br />

Wall mounting hole<br />

Note: 1. On Model :50, you would use flare nut packed with the Indoor<br />

Unit, when connnecting the Outdoor Unit for R407C, R22.<br />

2. In order to increase the strength of the flare nut, the size of<br />

some of them has been increased.<br />

J<br />

B<br />

132 15<br />

Air outlet<br />

A<br />

167<br />

2- ø 4.7<br />

Duct mounting hole<br />

220<br />

98 30<br />

49<br />

35<br />

8<br />

Refrigerant piping flare<br />

connection(Gas) G : LP<br />

Refrigeant piping flare<br />

connection(Liquid) H : HP<br />

Drain pan<br />

Strainer<br />

2 ✕ F - ø 4.7<br />

Duct mounting hole<br />

80<br />

2 ✕ 2 - 12 ✕ 16<br />

Wall mounting hole<br />

310 90<br />

300<br />

400<br />

Hose(accessory)<br />

OD ø 27(TOP ø 20)<br />

170<br />

639<br />

630<br />

430<br />

Level adjusting screw<br />

4 pcs.(attached)<br />

Air<br />

inlet<br />

90<br />

( 75 ) 500<br />

6<br />

Hose(accessory)<br />

OD ø 27(TOP ø 20)<br />

10<br />

220<br />

45<br />

Air filter<br />

D<br />

220<br />

170 300<br />

10<br />

<strong>Dimensions</strong><br />

Model A B C D E(Gas) F(Liquid)<br />

PFFY-P20VLEM-E 1050 640 600 610 ø12.7 ø6.35<br />

PFFY-P25VLEM-E 1050<br />

PFFY-P32VLEM-E 1170<br />

640<br />

760<br />

600<br />

720<br />

610<br />

730<br />

ø12.7<br />

ø12.7<br />

ø6.35<br />

ø6.35<br />

PFFY-P40VLEM-E 1170 760 720 730 ø12.7 ø6.35<br />

PFFY-P50VLEM-E 1410 1000 960<br />

✻1 ø12.7 ✻1 ø6.35<br />

970<br />

✻2 ø15.88 ✻2 ø9.52<br />

PFFY-P63VLEM-E 1410 1000 960 970 ø15.88 ø9.52<br />

G(Liquid)<br />

17<br />

✻1<br />

✻2<br />

17<br />

17<br />

17<br />

22<br />

22<br />

22<br />

G(Gas)<br />

27<br />

✻1<br />

✻2<br />

27<br />

27<br />

27<br />

29<br />

29<br />

29<br />

183.5 21<br />

25<br />

170<br />

Piping<br />

space<br />

✻1:R410A outdoor unit<br />

✻2:R407C,R22 outdoor unit<br />

B<br />

2-12 ✕16<br />

Floor mounting hole<br />

106<br />

PFFY-P20,25,32,40,50,63VLRM-E<br />

50<br />

84<br />

100<br />

10<br />

29<br />

120<br />

C<br />

E<br />

430<br />

Level adjusting screw<br />

4 pcs.(attached)<br />

Air<br />

inlet<br />

<strong>Dimensions</strong><br />

Model A B C D E F G(Gas) H(Liquid)<br />

PFFY-P20VLRM-E 886 640 572 610 360 4 ø12.7 ø6.35<br />

PFFY-P25VLRM-E 886 640 572 610 360 4 ø12.7 ø6.35<br />

PFFY-P32VLRM-E 1006 760 692 730 480 5 ø12.7 ø6.35<br />

PFFY-P40VLRM-E 1006 760 692 730 480 5 ø12.7 ø6.35<br />

PFFY-P50VLRM-E 1246 1000 932 970 720<br />

✻1 ø12.7 ✻1 ø6.35<br />

7<br />

✻2 ø15.88 ✻2 ø9.52<br />

PFFY-P63VLRM-E 1246 1000 932 970 720 7 ø15.88 ø9.52<br />

✻1:R410A outdoor unit<br />

✻2:R407C,R22 outdoor unit<br />

90<br />

9<br />

( 75 )<br />

J(Liquid) J(Gas)<br />

17 27<br />

17<br />

17<br />

17<br />

27<br />

27<br />

27<br />

✻1<br />

✻2<br />

22<br />

22<br />

✻1<br />

✻2<br />

29<br />

29<br />

22 29<br />

Air filter<br />

15<br />

45<br />

76 D<br />

B<br />

15<br />

2-12 ✕ 16<br />

Floor mounting hole<br />

106<br />

58


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P VMH-E-F<br />

(Fresh Air Intake Type)<br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

Power consumption<br />

(50/60Hz)<br />

Current<br />

<strong>External</strong> finish<br />

Dimension<br />

Net weight<br />

Heat exchanger<br />

Type<br />

Airflow rate<br />

Fan<br />

Motor<br />

<strong>External</strong><br />

static<br />

pressure<br />

(Low/Mid/High)<br />

Type<br />

Output<br />

❇1<br />

❇1<br />

❇1<br />

❇1<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Height<br />

Width<br />

Depth<br />

208V<br />

220V<br />

230V<br />

240V<br />

Heat pump models<br />

Cooling only<br />

110%(100% in case of heating below-5˚C(23˚F) 110%<br />

PEFY-P80, 140VMH-E-F<br />

kW<br />

BTU/h<br />

kW<br />

BTU/h<br />

kW<br />

kW<br />

A<br />

A<br />

mm(in.)<br />

mm(in.)<br />

mm(in.)<br />

kg(lbs.)<br />

m 3 /min<br />

L/s<br />

cfm<br />

Pa<br />

Pa<br />

Pa<br />

Pa<br />

kW<br />

<strong>Specifications</strong><br />

PEFY-P80VMH-E-F<br />

PEFY-P140VMH-E-F<br />

~ 220-240V 50Hz / ~ 208-230V 60Hz<br />

9.0 16.0<br />

30,700<br />

8.5<br />

54,600<br />

15.1<br />

29,000<br />

51,500<br />

0.16/0.21<br />

0.29/0.33<br />

0.16/0.21<br />

0.29/0.33<br />

0.67/0.91<br />

1.24/1.48<br />

0.67/0.91<br />

1.24/1.48<br />

Galvanizing<br />

380(15")<br />

1000(39-3/ 8 ") 1200(47- 1 / 4 ")<br />

900(35- 7 / 16 ")<br />

50(111") 70(155")<br />

Cross fin (Aluminum plate fin and copper tube)<br />

Sirocco fan✕ 1<br />

Sirocco fan✕ 2<br />

9.0<br />

18.0<br />

150<br />

300<br />

18<br />

636<br />

35/85/170 35/85/170<br />

40/115/190 50/115/190<br />

50/130/210 60/130/220<br />

80/170/220 100/170/240<br />

Single phase induction motor<br />

0.09 0.14<br />

Synthetic fiber unwoven cloth filter(long life)<br />

ø 15.88 (5/ 8 ") [R410A] / 19.05 (3/ 4 ") [R22,R407C]<br />

Air filter (option)<br />

Refrigerant<br />

Gas(Flare) mm(in.)<br />

ø 15.88( 5 / 8 ")<br />

pipe diameter<br />

Liquid(Flare) mm(in.)<br />

ø 9.52(3/ 8 ")<br />

Drain pipe diameter<br />

32 (1-1/4 inch)<br />

208, 220V dB(A)<br />

27/38/43<br />

Noise level<br />

❇2<br />

230, 240V dB(A)<br />

33/43/45<br />

Note: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.<br />

Cooling : Indoor 33˚C(91.4˚F)DB/28˚C(82.4˚F)WB,Outdoor 33˚C(91.4˚F)DB<br />

Heating : Indoor 0˚C(32˚F)DB/-2.9˚C(26.8˚F)WB,Outdoor 0˚C(32˚F)DB/-2.9˚C(26.8˚F)WB<br />

❇2 It is measured in anechoic room.<br />

a ). The cooling and heating capacities are the maximum capacities that were obtained by operating in the above air conditions and with a refrigerant pipe of about 7.5m(24- 5 / 8 Ft).<br />

b ). The actual capacity characteristics vary with the combination of indoor and outdoor units. See the technical information.<br />

c ). The operating noise is the data that was obtained by measuring it 1.5m(4-15/ 16 Ft) from the bottom of the unit in an anechoic room. (Noise meter A-scale value)<br />

d ). The figure of Electrical characteristic indicates at 220V and at middle external static pressure.<br />

e ). When the 100% fresh air indoor units are connected, the maximum connectable indoor units to 1 outdoor unit are as follows.<br />

f ). Operational temp range is cooling : from 21˚C(61.8˚F)DB/15.5˚C (59.9˚F)WB to 43˚C(109.4˚F)DB/35˚C(95˚F)WB.<br />

Heating : from -10˚C(14˚F)DB to 20˚C(68˚F)DB<br />

✻Thermo off (Fan) operation automatically starts either when temperature is lower than 21˚C(69.8˚F)DB in cooling mode or when the temperature exceeds 20˚C(68˚F)DB in heating mode.<br />

g).As the room temp is sensed by the thermo in the remote controller or the one in the room, be sure to use ether remote controller or room thermo.<br />

h).Dry mode is Not available. Fan mode operation during the thermo off in Cooling/Heating mode.<br />

i ). The fan would temporarily stops either with R2/WR2 system or in defrost.<br />

j ). In any case, the air flow rate should be kept lower than 110% of the above chart.Please see “ Fan curves “ for the details.<br />

k).When this unit is used as sole A/C system, be careful about the dew in air outlet grilles in cooling mode.<br />

l).Un-conditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation. Please be careful when positioning indoor unit air outlet grilles, ie take the necessary precautions for cold air, and also<br />

insulate rooms for dew condensation prevention as required.<br />

m). Air filter must be installed in the air intake side.The filter should be attached where easy maintenance is possible in case of usage of field supply filters.<br />

n). Long life filter cannot be used together with Hi-efficiency filter.<br />

<strong>External</strong> <strong>Dimensions</strong><br />

28/38/43<br />

34/43/45<br />

Required space for service and maintenance<br />

Unit : mm<br />

625<br />

G-ø3<br />

J-ø3<br />

100~200<br />

700<br />

150~200<br />

450<br />

Access door<br />

450<br />

50<br />

50<br />

L<br />

Note2<br />

D<br />

C<br />

50x(G-1)=H<br />

Air inlet<br />

Air outlet<br />

50x(J-1)=K<br />

B (Lifting bolt pitch)<br />

A<br />

E<br />

Access door Ceiling surface<br />

Make the access door at the appointed position<br />

properly for service maintenance.<br />

More than 20mm<br />

More than 20mm<br />

50<br />

50<br />

Less than 300mm<br />

170mm±5mm (Actual length)<br />

41 F<br />

10<br />

15<br />

80<br />

70<br />

Model:80(Note3)<br />

340<br />

Lifting bolt<br />

383<br />

814 (Lifting bolt pitch)<br />

904<br />

3<br />

60<br />

23<br />

250<br />

Less than 550mm<br />

3<br />

59<br />

900<br />

24<br />

847<br />

10<br />

Drain hole<br />

Control box (option)<br />

2<br />

Terminal bed<br />

1<br />

(Power source)<br />

92 200<br />

Terminal box Terminal bed<br />

343<br />

(Transmission)<br />

Keep duct-work length 850mm or more.<br />

387<br />

Drain hole<br />

17 340<br />

45 50x5=250<br />

50<br />

30<br />

29<br />

15<br />

50 50 50 50<br />

77<br />

328<br />

250<br />

380<br />

41 25<br />

130<br />

94<br />

Model<br />

PEFY-P80VMH-E-F<br />

PEFY-P140VMH-E-F<br />

A<br />

1050<br />

1250<br />

B<br />

1004<br />

1204<br />

Note<br />

When installing the drain<br />

water lifting-up mech(option).<br />

1.Use M10 screw for the lifting bolt (field supply).<br />

2.Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned.<br />

3.This chart indicates for PEFY-P140VMH-E-F models, which have 2 fans.<br />

PEFY-P80VMH-E-F model has 1 fan.<br />

4.Make sure to install the air filter(field supply) on the air intake side.<br />

In case field supplied air filter is used, attach it where the filter service is easily done.<br />

5.On Model :140, you would use flare nut packed with the Indoor Unit,<br />

when connnecting the Outdoor Unit for R407C, R22.<br />

6.In order to increase the strength of the flare nut,<br />

P<br />

the size of some of them has been increased.<br />

Refrigerant piping flare connection(gas M copper tube):LP ······ ➀<br />

Refrigerant piping flare connection(liquid N copper tube):HP ······ ➁<br />

Drain hose 32mm(1-1/4inch) (accessory) ······ ➂<br />

C D E F G H J K L M N P(Liquid) P(Gas)<br />

930 850 800 25 17 800 15 700 1030 ø15.88 ø9.52 22 29<br />

✻1 ø15.88<br />

✻1:R410A outdoor unit<br />

1130 1050 1000 25 21 1000 19 900 1230<br />

ø9.52 22 36<br />

✻2 ø19.05<br />

✻2:R407C,R22 outdoor unit


INDOOR UNIT<br />

<strong>Specifications</strong> & <strong>External</strong> <strong>Dimensions</strong><br />

PEFY-P VMH-E-F<br />

(Fresh Air Intake Type)<br />

Power source<br />

Cooling capacity<br />

Heating capacity<br />

Power consumption<br />

(50/60Hz)<br />

Current<br />

<strong>External</strong> finish<br />

Dimension<br />

Net weight<br />

Heat exchanger<br />

Type<br />

Airflow rate<br />

Fan<br />

<strong>External</strong><br />

static<br />

pressure<br />

Type<br />

Motor<br />

Output<br />

Air filter (option)<br />

Refrigerant<br />

pipe diameter<br />

Drain pipe diameter<br />

Noise level<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Height<br />

Width<br />

Depth<br />

380V<br />

400V<br />

415V<br />

Gas<br />

(Flare)<br />

Liquid<br />

(Flare)<br />

380V<br />

400V<br />

415V<br />

PEFY-P200, 250VMH-E-F<br />

kW<br />

BTU/h<br />

kW<br />

BTU/h<br />

kW<br />

kW<br />

A<br />

A<br />

mm(in.)<br />

mm(in.)<br />

mm(in.)<br />

kg(lbs.)<br />

m 3 /min<br />

L/s<br />

cfm<br />

Pa<br />

Pa<br />

Pa<br />

kW<br />

mm(in.)<br />

mm(in.)<br />

dB(A)<br />

dB(A)<br />

dB(A)<br />

<strong>Specifications</strong><br />

PEFY-P200VMH-E-F<br />

PEFY-P250 VMH-E-F<br />

3N~ 380-415V 50Hz / 60Hz<br />

22.4 28.0<br />

76,400 95,500<br />

21.2<br />

26.5<br />

72,300 90,400<br />

0.34/0.42<br />

0.39/0.50<br />

0.34/0.42<br />

0.39/0.50<br />

0.58/0.74<br />

0.68/0.86<br />

0.58/0.74<br />

0.68/0.86<br />

Galvanized<br />

470 (18-9/16")<br />

1250 (49-1/4")<br />

1120 (44-1/8")<br />

100 (221")<br />

Cross fin<br />

Sirocco fan ✕ 2<br />

28<br />

35<br />

467<br />

583<br />

989<br />

1236<br />

140/200 110/190<br />

150/210 120/200<br />

160/220 130/210<br />

3-phase induction motor<br />

0.20 0.23<br />

Synthetic fiber unmoven cloth filter (long life type)<br />

ø 19.05 ( 3 /4") [R410A]<br />

ø 22.2 ( 7 /8") [R410A]<br />

ø 25.4 (1") [R22,R407C]<br />

ø 28.58 (1- 1 /8") [R22,R407C]<br />

ø9.52 (3/8") [R410A]<br />

ø9.52 ( 3/8") [R410A]<br />

ø 12.7 (1/2") [R22,R407C]<br />

ø 12.7 (1/2") [R22,R407C]<br />

Unit drain pipe I.D 32 (1-1/4 inch)<br />

39/42<br />

40/44<br />

40/43<br />

40/45<br />

40/44<br />

41/46<br />

Note: 1. The cooling amd heating capacites are the maximum capacites that were obitained by operating in the above air conditions and with a refrigerant pipe of about 7.5m.<br />

2 .The actual capacity characteristics vary with the combination of indoor and outdoor units. See the technical infomation.<br />

3 .The operating noise is the data that was obitained by measuring it 1.5m from the the bottom of the unit in an anechoic room. (Noise meter A-scale value)<br />

4 .The figure of Electrical characteristic , indicates at 220 Pa setting at 415V.<br />

5 . When the 100% fresh air indoor units are connected, the maximum connectable indoor units to 1 outdoor unit are as follows.<br />

Heat pump models<br />

Cooling only<br />

110%(100% in case of heating below-5˚C(23˚F)) 110%<br />

6. Operational temp range is Cooling:from 21˚C(69.8˚F)DB/15.5˚C(59.9˚F)WB to 43˚C(109.4˚F)DB/35˚C(95˚F)WB<br />

Heating: from -10˚C(14˚F)DB to 20˚C(68˚F)DB.<br />

❇ Thermo off(Fan) operation automatically starts either when temperature is lower than 21˚C(69.8˚F)DB in cooling mode or when the temperature exceeds 20˚C(68˚F)DB in heating mode.<br />

7. As the room temp in sensed by the thermo in the remote controller or the one in the room, be sure to use either remote controller or room thermo.<br />

8. Autochangeover function or Dry mode is NOT available. Fan mode operation during the thermo off in Cooling/Heating mode.<br />

9. The fan would temporaly stops either with R2/WR2 system or in defrost.<br />

10. In any case, the air flow rate should be kept lower than 110% of the above chart. Please see "Fan curves" for the details.<br />

11. When this nit is used as sole A/C system, be careful about the dew in air outlet grilles in cooling mode.<br />

12. Un-conditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation.<br />

Please be careful when positioning indoor unit air outlet grilles, ie take the necessary precautions for cold air, and also insulate rooms for dew condensation prevention as required.<br />

13. Air filter must be installed in the air intake side. The filter should be attached where easy maintenance in possible in case of usage of fild supply filters.<br />

22-ø3<br />

<strong>External</strong> <strong>Dimensions</strong><br />

22-ø3<br />

Required space for service and maintenance<br />

Unit : mm<br />

730<br />

1100<br />

1250<br />

50x21=1050<br />

Air outlet<br />

Air outlet<br />

50x20=1000<br />

1326(Lifting bolt pitch)<br />

1372<br />

1100<br />

200~300<br />

800<br />

150~200<br />

450<br />

Access door<br />

450<br />

50<br />

50<br />

1350<br />

Note2<br />

More than 20<br />

25<br />

102<br />

10<br />

15<br />

50<br />

100<br />

Access door Ceiling surface<br />

Make the access door at the appointed position properly maintenance.<br />

More than 20<br />

420<br />

Lifting bolt<br />

4-14X30<br />

420<br />

50x7=350<br />

20<br />

35<br />

24<br />

10<br />

Keep duct-work length 850mm or more.<br />

Control box<br />

Terminal bed<br />

(Power source)<br />

Terminal bed<br />

(Transmission)<br />

170 - + 5<br />

30<br />

78<br />

3<br />

1034(Lifting bolt pitch) 60 340<br />

1124<br />

1120<br />

1067<br />

29<br />

15<br />

Drain hole<br />

(option)<br />

Drain hole<br />

2 1<br />

95 249<br />

422<br />

489<br />

44<br />

327<br />

50x6=300<br />

340<br />

470<br />

41<br />

164<br />

23<br />

20<br />

105<br />

Less than 550<br />

When installing the drain water lifting-up<br />

Less than 300<br />

170mm+5mm (Actual length)<br />

Refrigerant piping brazing connection(gas A copper tube):LP ······ ➀<br />

Refrigerant piping brazing connection(liquid B copper tube):HP ······ ➁<br />

Drain hose 32mm(1-1/4inch) (accessory) ······ ➂<br />

3<br />

Model A B<br />

PEFY-P200VMH-E-F ✻1 ø19.05 ✻1 ø9.52<br />

✻2 ø25.4 ✻2 ø12.7<br />

PEFY-P250VMH-E-F ✻1 ø22.2 ✻1 ø9.52<br />

✻2 ø28.58 ✻2 ø12.7<br />

✻1:R410A outdoor unit ✻2:The other outdoor unit<br />

Note 1. Use M10 screw for the lifting bolt (field supply).<br />

2.Keep the service space for maintenance from<br />

the bottom<br />

when the heat exchanger is cleaned.<br />

3.Make sure to install the air filter (field supply) on<br />

the air intake side.<br />

In case field supplied air filter is used, attach it<br />

where the filter service is easily done.<br />

4.On this model, you would use pipe<br />

packed with the Indoor Unit, when connnecting<br />

the Outdoor Unit for R407C, R22.<br />

60


0<br />

Fresh cool air(outdoor)<br />

5.2<br />

Stale hot air (exhaust)<br />

The Ventilation System for Enhanced Air Quality - Lossnay<br />

Combine with Lossnay Ventilation System Enhanced Air Quality.<br />

Unified Control System Allows Greater Design Freedom.<br />

Heat-Exchange Efficiency Obtainable Only with Lossnay.<br />

The secret to the unmatched comfort provided Lossnay core is the crossflow,<br />

plate-fin structure off the heat-exchange unit. A diaphragm made of a<br />

specially processed paper fully separates inducted and exhausted air<br />

supplies, ensuring that only fresh air is introduced to the indoor environment.<br />

The superior heat-transfer and moisture permeability of the special paper<br />

assure highly effective total heat exchange (temperature and humidity) when<br />

inducted ? and exhausted air supplies cross in the Lossnay core.<br />

20<br />

Stale warm air (indoor air)<br />

Lossnay Element<br />

Construction & Principle<br />

Stale air exhaust<br />

(dirty indoor air)<br />

EA<br />

Outdoors<br />

Fresh air exhaust<br />

(fresh heating / cooling air)<br />

SA<br />

Indoors<br />

14.8<br />

Fresh warm air (indoor supply air)<br />

OA<br />

Fresh air induction<br />

(fresh air)<br />

RA<br />

Stale air induction<br />

(dirty heating / cooling air)<br />

LGH-15RX4<br />

LGH-25RX4<br />

LGH-35RX4<br />

LGH-50RX4<br />

LGH-65RX4<br />

LGH-80RX4<br />

LGH-100RX4<br />

LGH-150RX4<br />

LGH-200RX4<br />

[150m 3 /h Single phase 220-240V 50/60Hz]<br />

[250m 3 /h Single phase 220-240V 50/60Hz]<br />

[350m 3 /h Single phase 220-240V 50/60Hz]<br />

[500m 3 /h Single phase 220-240V 50/60Hz]<br />

[650m 3 /h Single phase 220-240V 50/60Hz]<br />

[800m 3 /h Single phase 220-240V 50/60Hz]<br />

[1000m 3 /h Single phase 220-240V 50/60Hz]<br />

[1500m 3 /h Single phase 220-240V 50/60Hz]<br />

[2000m 3 /h Single phase 220-240V 50/60Hz]<br />

OA Processing Units<br />

Ideal Indoor-Air Quality — For Your Comfort and Health<br />

The OA (outdoor-air) Processing Unit creates an optimum indoor-air environment at an unparalleled rate of cost efficiency providing substantial<br />

energy savings. Forced air ventilating and humidifying functions unique to this system keep indoor-air fresh and free of contaminants preventing<br />

“sick building syndrome” and the spread of airborne viruses such as the flu. Another novel feature of the OA Processing Unit is the “Lossnay<br />

core,” a heat-exchange unit that functions to transfer heat efficiently, cutting ventilation load by as much as 70%. This special combination of<br />

functionality<br />

and performance designed to ensure users ample comfort and year-round health cannot be found anywhere else on the market.<br />

EA (Exhaust air)<br />

Heat from the indoor air (both sensible<br />

and latent) is recovered by the Lossnay<br />

OA (Outdoor air)<br />

Core and vented outside by the<br />

Fresh, outdoor-air in a quantity exhaust fan.<br />

required for ventilation is drawn<br />

in by the supply fan.<br />

The exhaust fan<br />

High efficiency filters (Option)<br />

The supply fan<br />

OA Processing Units<br />

61<br />

Heat recovery unit<br />

(Lossnay Core)<br />

Temperature and humidity are<br />

exchanged between the supply<br />

air and the exhaust air.<br />

Maintenance cover<br />

Air filter<br />

Prevents clogs in<br />

the Lossnay Core.<br />

DX Heat exchanger<br />

Cools or heats the drawn<br />

in outdoor-air.<br />

SA (Supply air)<br />

The processed, fresh<br />

outdoor-air is vented<br />

to the indoor rooms.<br />

RA (Return air)<br />

The exhaust<br />

fan draws in<br />

contaminated<br />

indoor-air.<br />

GUF-50RD(H)3 *1<br />

Cooling Capacity<br />

5.29 (DX coil:3.63, Lossnay:1.66)KW<br />

Heating capacity<br />

6.42 (DX coil:4.17, Lossnay:2.25)KW<br />

500m 3 /h Single phase 220-240V 50Hz<br />

GUF-100RD(H)3 *1<br />

Cooling Capacity<br />

10.81 (DX coil:7.32, Lossnay3.49)KW<br />

Heating capacity<br />

13.00 (DX coil:8.30, Lossnay:4.70)KW<br />

1000m 3 /h Single phase 220-240V 50Hz<br />

*1 H : Humidifying Type


Y : PUHY<br />

R2 : PURY<br />

WY : PQHY<br />

WR2 : PQRY<br />

S : PUMY<br />

INDOOR UNIT<br />

PLFY-VAM / VCM PCFY-VGM<br />

PLFY-VLMD<br />

PKFY-VAM / VGM / VFM<br />

PMFY-VBM<br />

PFFY-VKM<br />

PEFY-VMS<br />

PFFY-VLRM / VLEM<br />

PEFY-VMR<br />

Fresh Air Intake type<br />

PEFY-VML / VMM / VMH<br />

LONWORKS<br />

62


Integrated Communications Control with Mitsubishi's Unique Transmission Network(M-NET)<br />

Operation<br />

Start / Stop<br />

Operation mode<br />

Temperature setting<br />

Permit / Prohibit direction<br />

Fan speed<br />

Air flow direction<br />

ON/OFF<br />

Model<br />

No. of units controllable<br />

(Groups (G) / units)<br />

Error flashing<br />

Local remote controller<br />

System controller<br />

Simple Wireless ON/OFF Group System<br />

Remote controller<br />

Schedule<br />

remote remote remote remote remote<br />

Centralized controller<br />

timer<br />

controller controller controller controller controller<br />

PAR-21MAA PAR-F27MEA PAC-SE/YT51CRA PAR-FA32MA PAR-FL32MA PAC-YT40ANRA PAC-SC30GRA PAC-SF44SRA PAC-YT34STA G-50A GB-50A TG-2000A<br />

50G/50units 50G/50units<br />

1G/16units 1G/16units 1G/16units 1G/16units 16/50 8G/16units 50/50 50G/50U 2000G/2000units<br />

G-50A browser GB-50A browser<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

*4<br />

*4<br />

*4<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

63<br />

Monitoring<br />

Scheduling<br />

Recording<br />

Others<br />

Control and<br />

management<br />

Operation<br />

Monitoring<br />

Error content<br />

Filter sign<br />

Operating hour<br />

Operation mode<br />

Set temperature<br />

Indoor temperature (intake)<br />

Permit / Prohibit<br />

Fan speed<br />

Air flow direction<br />

Weekly<br />

Annual (Designated day setting)<br />

One day<br />

Times of stops / Starts per day<br />

Times of stops / Starts per week<br />

Auto off timer<br />

Minimum setting unit (minutes)<br />

Error history<br />

Daily / Monthly reports<br />

Electricity charges<br />

Set temperature range limit<br />

Auto lock<br />

Ventilation (group / interlocked)<br />

Group setting<br />

Block setting<br />

Revision of electricity charges<br />

Ventilation<br />

(group / interlocked)<br />

Ventilation<br />

(group / interlocked)<br />

Start / Stop<br />

Fan speed<br />

Ventilation mode<br />

Status<br />

Fan speed<br />

Ventilation mode<br />

✕<br />

✕<br />

8 *5<br />

56<br />

1 *5<br />

✕<br />

✕<br />

✕<br />

✕ /<br />

✕<br />

✕<br />

*5<br />

*1<br />

✕<br />

✕<br />

✕<br />

1/1<br />

✕<br />

10 *5<br />

✕<br />

✕<br />

✕<br />

✕ /<br />

✕<br />

✕<br />

: Each group / Batched : Each group : Block (City Multi indoor unit only)<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

: Batched handling (for maintenance) : Batched only ✕ : Not available – : Not used : G-50A license registration possible.<br />

*1: For group operation, cross-over wring is required between indoor unit. *2: Installation possible at Initial setting tool.<br />

*3: Interlock setting from local remote controller. *4: From schedule setting *5: When PAC-YT32PTA is connected.<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

1/1<br />

✕<br />

✕<br />

10<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

/ ✕<br />

✕<br />

✕<br />

*3<br />

/<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕ / * 5<br />

✕<br />

✕<br />

*<br />

✕ /48<br />

5<br />

*<br />

✕ /336<br />

5<br />

✕<br />

* 5 ✕ /30<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕ /<br />

✕<br />

✕<br />

– /<br />

– /<br />

– / ✕<br />

– /<br />

– /<br />

– / ✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

/<br />

/<br />

/ ✕<br />

/<br />

/<br />

/ ✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

16<br />

112<br />

✕<br />

5<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

/<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

3/3<br />

21/21<br />

✕<br />

10<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

/<br />

/<br />

/ ✕<br />

/<br />

/<br />

/ ✕<br />

✕<br />

12<br />

84<br />

✕<br />

1<br />

✕<br />

✕<br />

✕<br />

/<br />

✕<br />

/<br />

/<br />

/ ✕<br />

/<br />

/<br />

*2<br />

*2<br />

*2<br />

*2<br />

/ ✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

/<br />

/<br />

✕<br />

✕<br />

✕<br />

✕<br />

✕<br />

12<br />

84<br />

✕<br />

1<br />

✕<br />

✕<br />

✕<br />

/<br />

✕<br />

/<br />

/<br />

/ ✕<br />

/<br />

/<br />

*2<br />

*2<br />

*2<br />

*2<br />

/ ✕<br />

12<br />

84<br />

✕<br />

1<br />

✕<br />

/<br />

/<br />

/<br />

/ ✕<br />

/<br />

/<br />

/ ✕


Building Air conditioning<br />

control system<br />

HAND-HELD<br />

REMOTE CONTROLLER<br />

MA REMOTE CONTROLLER PAR-21MAA<br />

Example of system configuration<br />

M-NET<br />

Non-polarized<br />

2-wire<br />

MA remote controller<br />

Non-polarized<br />

2-wire<br />

MA remote controller<br />

High-quality pure-white color body<br />

Dot liquid-crystal display is applied<br />

Symbols, Japanese, Chinese, English, Germany,Spanish, Russian,<br />

Italian, French display can be selected freely.<br />

TM<br />

Connectable to all CITYMULTI indoor unit, and<br />

automatically adjust its function with the indoor unit<br />

connected<br />

Limiting temperature setting range is possible<br />

Help to avoid over-cooling or over-heating. Save energy.<br />

Auto-stop timer is available<br />

Help to avoid forgetting to stop the air conditioner.<br />

Weekly scheduler is available<br />

ON/OFF/Temperature setting 8 times per day, 1 week scheduling.<br />

Grouping via cross-over wire directly<br />

Usable as the local remote controller for system controller<br />

(MELANS)<br />

Combining ME remote controller and/or LOSSNAY remote<br />

controller in a group is not possible.<br />

LCD temperature setting and display in<br />

1˚C /1˚F unit.<br />

ME REMOTE CONTROLLER PAR-F27MEA<br />

Example of system configuration<br />

ME remote controller<br />

ME remote controller<br />

Easy to read, easy to operate icon display<br />

Temperature selection<br />

Room air temperature display<br />

Outlet angle display<br />

Displays the angle of blowing between 20˚ and 70˚. (Only for cassette<br />

model PL and PK. Ceiling mounted models display the air volume<br />

ratio.)<br />

Auto-diagnosis display<br />

A microcomputer constantly monitors operation to keep the units<br />

running smoothly. Should problems occur, the temperature setting<br />

display changes to an auto-diagnosis display that shows the<br />

inspection mode and the unit address alternately.<br />

Standardized remote controllers for all indoor units<br />

All wiring is simply done with non-polarized two-wire signal<br />

lines<br />

Room thermometer is built into the remote controller<br />

Daily timer<br />

Repeated ON / OFF timer every day.<br />

Auto OFF timer<br />

0:30, 1:00, 1:30, 2:00...4:00 one touch timer.<br />

Function lock<br />

All functions or all functions except ON / OFF can be selected.<br />

Limit setting of room temperature.<br />

64


Building Air conditioning<br />

control system<br />

HAND-HELD<br />

REMOTE CONTROLLER<br />

SIMPLE MA REMOTE CONTROLLER PAC-YT51CRA<br />

PAC-YT51CRA<br />

To simplify operation of the system, the range of controls has been<br />

limited to START/STOP, room temperature and fan speed<br />

The only wiring required is cross-over wiring based on two-wire<br />

signal lines<br />

Room temperature sensors are built-in. The indoor unit can be<br />

replaced with body thermostats<br />

Easy to read, easy to operate icon display<br />

LCD temperature setting and display in<br />

1˚C /1˚F unit.<br />

Can operate all types of indoor units<br />

Standardized remote controllers for all indoor units<br />

*Since this system has no operation mode switching, test operation, selfdiagnosis<br />

or interlock setting functions, it should always be used in conjunction<br />

with the PAR-21MAA or other centralized controller.<br />

*Combining ME remote controller and/or LOSSNAY remote<br />

controller in a group is not possible.<br />

WIRELESS REMOTE CONTROLLER PAR-FL32MA / PAR-FA32MA<br />

• Wireless construction supports multi - systems in<br />

buildings.<br />

• No need to configure addresses for group operation.<br />

• Lit LED keeps you informed of operation - blinking even<br />

gives you the error code via the number of blinks.<br />

• Can be used with the MA remote controller.<br />

*When used in group configurations, wiring between indoor units is<br />

required.<br />

*Combining ME remote controller and/or LOSSNAY remote<br />

controller in a group is not possible.<br />

• LCD temperature setting and display in 1˚C /1˚F unit.<br />

PAR-FL32MA<br />

PAR-FA32MA<br />

65


UP<br />

UP<br />

POWER SUPPLY UNIT<br />

MODEL PAC-SC50KUA<br />

POWER RATING<br />

WEIGHT<br />

2.11kg<br />

SERIAL No.<br />

MITSUBISHI ELECTRIC CORPORATION<br />

POWER SUPPLY UNIT<br />

MODEL PAC-SC50KUA<br />

POWER RATING<br />

WEIGHT<br />

2.11kg<br />

SERIAL No.<br />

MITSUBISHI ELECTRIC CORPORATION<br />

Building Air conditioning<br />

control system<br />

CENTRALIZED<br />

REMOTE CONTROLLER<br />

CENTRAL CONTROLLER G-50A/GB-50A<br />

Up to 50 units of packaged air conditioners can freely be monitored<br />

and operated!<br />

Furthermore, it has enabled the Monitoring and Operation Via a<br />

Web Browser on a Personal Computer connected to it using a LAN<br />

or telephone line!<br />

First in the industry<br />

With Web Server<br />

Functions!<br />

G-50A (with display)<br />

GB-50A<br />

Simple and Flexible<br />

This new generation controller is suitable for small to large systems<br />

with simple to complex functions available.<br />

Web Browser<br />

Enables monitoring and operation of air conditioning units using a PC<br />

with Microsoft ® Internet Explorer.<br />

Remote Access<br />

Allows users to remotely monitor and operate the air conditioning<br />

units using a PC connected to a telephone line.<br />

Auto Alarm<br />

In the case of any malfunction, necessary information will be sent to a<br />

mobile phone and/or personal computer by e-mail.<br />

Easy to Upgrade<br />

Various new functions will be introduced gradually and can easily be<br />

down loaded into any existing G-50A/GB-50A.<br />

Example: Energy Monitoring<br />

Demand Control<br />

Annual Schedule<br />

Example of display icons (air conditioner icons)<br />

Operation<br />

In timer operation<br />

Stop<br />

Lossnay on<br />

Occurrence of<br />

abnormality<br />

Under energy-saving<br />

control<br />

Operation/<br />

Occurrence of a filter sign<br />

System Structure<br />

Remote monitoring via a<br />

Web browser<br />

Web browser<br />

G-50A<br />

City Multi<br />

outdoor unit<br />

M-NET<br />

Public telephone<br />

line<br />

Provider<br />

Router<br />

Ethernet<br />

Power supply unit<br />

PAC-SC50KUA<br />

City Multi<br />

Provider<br />

GB-50A<br />

City Multi<br />

outdoor unit<br />

M-NET<br />

Power supply unit<br />

PAC-SC50KUA<br />

City Multi<br />

* Microsoft is a trademark or trademark of Microsoft corporation.<br />

66


UP<br />

Building Air conditioning<br />

control system<br />

CENTRALIZED<br />

REMOTE CONTROLLER<br />

GROUP REMOTE CONTROLLER PAC-SC30GRA<br />

Up to 8 groups can be operated (maximum of 16 units). Just by<br />

pressing switches, groups can be started and stopped<br />

individually, or all groups can be started and stopped as a<br />

batch.<br />

Detailed settings and operations can also be made for each<br />

individual group.<br />

All the wiring is simply done with non-polarized two wire signal<br />

lines. The connection is the same as the connection to the<br />

master system controller.<br />

It supports operation of groups that can extend beyond one<br />

refrigerant system. Furthermore, it is possible to drive<br />

interlocked systems that use ventilator equipment or drive<br />

ventilator equipment in a stand-alone situation.<br />

*With the group remote controller, you cannot control groups that<br />

only contain the LOSSNAY remote controller.<br />

*It is impossible to use the group remote controller to control K<br />

control units.<br />

*When connecting to signal cables for central control, it must use a<br />

power supply unit for the signal cables.<br />

System example<br />

Connect to the centralized transmission line<br />

Group remote<br />

controller<br />

Power supply<br />

unit<br />

MA R/C<br />

MA R/C<br />

R/C:Remote Controller<br />

Connect to the indoor/outdoor transmission line<br />

67<br />

R/C:Remote Controller<br />

Group remote<br />

controller<br />

MA R/C<br />

MA R/C


UP<br />

Building Air conditioning<br />

control system<br />

CENTRALIZED<br />

REMOTE CONTROLLER<br />

SYSTEM REMOTE CONTROLLER PAC-SF44SRA<br />

50 groups/50 units of air conditioners can be controlled<br />

Up to 50 groups/50 units of air conditioners can be operated with one remote<br />

controller.<br />

A general-purpose interface is available for control, so general devices can also be<br />

turned ON and OFF.<br />

Operation status displayed on easy-to-read LCD<br />

The group currently operating can be seen at a glance with the operation status<br />

display for each group.<br />

Independent LOSSNAY operation is possible<br />

LOSSNAY units can be grouped the same as the Central remote controller and<br />

ON/OFF remote controller.<br />

"Automatic ventilation", "Normal ventilation" and "Ventilation with heat<br />

exchanger" can be switched from the system controller.<br />

Simple remote controller limited to basic operations.<br />

The only operations required for the air conditioner are "ON/OFF", "Operation<br />

mode changeover", "Temperature setting" and "Prohibit operation by local remote<br />

controller", so anyone can easilyoperate the unit.<br />

Using collective control from the system remotecontroller, operation mode settings<br />

using the local remote controllers can be prohibited.<br />

(Operation mode limit function)<br />

Schedule operation is available<br />

Groups of air conditioners are available for operation at a set schedule using the<br />

Schedule timer (PAC-YT34STA).<br />

System example<br />

System<br />

remote<br />

controller<br />

Power<br />

supply<br />

unit<br />

MA R/C<br />

MA R/C<br />

LOSSNAY<br />

PZ-52SF<br />

LOSSNAY<br />

LOSSNAY<br />

PZ-52SF<br />

R/C:Remote Controller<br />

68


UP<br />

Building Air conditioning<br />

control system<br />

CENTRALIZED<br />

REMOTE CONTROLLER<br />

Schedule timer PAC-YT34STA<br />

The weekly schedule of up to 50 groups/50 units can be<br />

controlled with one schedule timer.<br />

General-purpose devices can also be turned ON and OFF by<br />

connecting a general-purpose interface.<br />

The weekly schedule of up to ten patterns (no setting + nine<br />

patterns) is available for setting.<br />

"ON/OFF", "Operation Prohibit", "COOL/HEAT" and "Set<br />

Temperature" can be scheduled with up to 16 settings in one<br />

pattern.<br />

It can be connected to the center control transmission line or to<br />

the indoor/outdoor transmission line without the power supply<br />

unit (PAC-SC50KUA). It is nonpolar 2-wire.<br />

It can be interlocked with a building management system using<br />

the external input/output managing function.<br />

An error unit address and error code appear on the display.<br />

(*) Use in combination with other system controllers.<br />

System example<br />

System<br />

remote<br />

controller<br />

Power supply<br />

unit<br />

ME R/C<br />

LOSSNAY<br />

Schedule timer<br />

MA R/C<br />

Simple<br />

ME R/C<br />

R/C:Remote Controller<br />

69


Building Air conditioning<br />

control system<br />

CENTRALIZED<br />

REMOTE CONTROLLER<br />

ON/OFF remote controller PAC-YT40ANRA<br />

16 groups/50 units can be controlled<br />

Up to 16 groups/50 units can be operated with one ON/OFF remote controller.<br />

A general-purpose interface is available for control, so general devices can also be<br />

turned ON and OFF.<br />

Just press a switch to start.<br />

All of the units can be started and stopped by pressing the main switch, and each<br />

unit in the group can be started and stopped with individual switches.<br />

A general-purpose interface is available for control, so general devices can also be<br />

turned ON and OFF.<br />

LED flashing during failure.<br />

If any error should occur in the air conditioner, its details can be confirmed easily<br />

with the flashing LED. The LED also indicates whether each group is running or<br />

stopped.<br />

Interlock operation with external system possible.<br />

It can be flexibly interlocked with a card reader, fire alarm system or building<br />

management system, etc., using the incorporated external input/output function.<br />

Flexible group setting.<br />

The groups can be easily configured, so the group pattern can be freely set<br />

according to the layout.<br />

The ON/OFF remote controller can be connected at the indoor/outdoor<br />

transmission line without the power supply unit.<br />

System example<br />

LOSSNAY<br />

ON/OFF<br />

remote<br />

controller<br />

PAR-F27MEA<br />

PZ-52SF<br />

PAR-21MAA<br />

R/C:Remote Controller<br />

PAC-YT51CRA<br />

70


UP<br />

POWER SUPPLY UNIT<br />

MODEL PAC-SC50KUA<br />

POWER RATING<br />

WEIGHT<br />

2.11kg<br />

SERIAL No.<br />

MITSUBISHI ELECTRIC CORPORATION<br />

Building Air conditioning<br />

control system<br />

CENTRALIZED<br />

REMOTE CONTROLLER<br />

Integrated centralized control software TG-2000A<br />

(1) Example of Basic System Configuration.<br />

Charge<br />

license<br />

Web<br />

monitor<br />

license<br />

Input<br />

G-50A<br />

12VDC<br />

M-NET<br />

Single-phase 208/230V<br />

Single-phase 208/230V<br />

Schedule<br />

license<br />

Uninterruptive<br />

power supply (UPS)<br />

Power supply unit<br />

PAC-SC50KUA<br />

3-phase 208/230V<br />

(3-wire)<br />

RS-232C<br />

RS-485<br />

Indoor unit system<br />

watt-hour meter<br />

Outdoor unit system<br />

watt-hour meter<br />

Converter<br />

Central controller<br />

personal computer<br />

TG-2000A<br />

Indoor unit<br />

watt-hour meter<br />

Compatible with TG-2000A Ver. 4.10 and higher<br />

* The electric amount count software or separately<br />

procured parts must be used with the designated PLC.<br />

Uninterruptible<br />

power supply (UPS)<br />

power source<br />

Indoor unit system<br />

watt-hour meter<br />

Indoor unit<br />

watt-hour meter<br />

Outdoor unit system<br />

watt-hour meter<br />

PLC (with electric amount count<br />

software)<br />

Central control<br />

personal computer<br />

TG-2000A<br />

Integrated<br />

centralized control<br />

software installation<br />

Integrated centralized control<br />

software installation<br />

71<br />

Main features of TG-2000A<br />

The TG-2000A can realize the following functions using<br />

the G-50A/GB-50A option (license).<br />

* Operation/monitor<br />

* Annual/weekly schedule<br />

* Charge<br />

* Energy saving *1<br />

* Peak cut *1<br />

*1: Compatible with TG-2000A Ver. 4.10 and higher,<br />

G-50A Ver. 2.51 or later.<br />

1 Up to 2000 indoor units (40 G-50A/GB-50A units) can be operated and monitored simultaneously.<br />

2 The air-conditioner layout can be displayed on the screen, making control and operation easier.<br />

3 The annual and weekly schedules can be set. Two schedules, such as the summer master and winter master, can be<br />

saved in the weekly schedule.<br />

4 Air-conditioning charges can be calculated based on the multiple air-conditioner usage results. The power apportionment<br />

percentage data and apportioned power rate can be calculated for each indoor unit using the power apportionment<br />

function, and can be output as a CSV format file. * Power apportionment charging is not possible with the old model, A control or K control.<br />

Charging without WHM : The user manually inputs the power rate to calculate the air-conditioning charges. (Using a tool)<br />

RS-485 WHM charging : The RS-485 WHM value is automatically tabulated to calculate the air-conditioning charges.<br />

PLC + pulse WHM charging : The pulse output WHM value is automatically tabulated by the PLC to calculate the air-conditioning charges.<br />

5 Energy saving operation is possible using the "ON/OFF", "set temperature change", "fan operation changeover" and<br />

"performance save operation (60% to 90%)" functions.<br />

Energy saving operation matching the amount of power in use is possible by using the PLC's electric amount count software.<br />

6 Night set-back operation is possible with schedule settings. *1*4<br />

7 General equipment can be operated and monitored. *2<br />

8 General equipment can be schedule-controlled when using PAC-YG21CDA with PLC.<br />

For details of PLC refer to Installation Manual of PAC-YG21CDA. *3<br />

*1: Compatible with TG-2000A Ver. 4.10 and higher, G-50A Ver. 2.51 and higher.<br />

*2: Compatible with TG-2000A Ver. 4.30 and higher, G-50A Ver. 2.51 and higher.<br />

*3: Compatible with TG-2000A Ver. 4.60 and higher, G-50A Ver. 2.70 and higher.<br />

*4: With Night Set-Back function,the CITY MULTI system can run at heating mode with target temperature set to 54 F/12 C<br />

under schedule control. This function can protect the room from dropping down to extremely low temperature at mid-night.


Building Air conditioning<br />

control system<br />

CENTRALIZED<br />

REMOTE CONTROLLER<br />

LONWORKS (LMAP02)<br />

CITY MULTI TM can easily combine into a Building Management System (BMS) via the LonWorks TM and M-NET adapter<br />

LMAP03-U. LonWorks TM is an opened transmission protocol widely used at BMS, and related equipment control.<br />

CITY MULTI TM is therefore compatible with large-scaled BMS management via LonWorks TM .<br />

One LM ADAPTER unit can connect up to 50 Groups/50 indoor units.<br />

Using a single LONWORKS adapter (LM ADAPTER), you can connect up to<br />

a maximum of 50 indoor units.<br />

Operation<br />

Monitor<br />

Item<br />

Request On/Off<br />

Request Mode<br />

Setpoint from network (Both cool and heat)<br />

Request Fanspeed<br />

Request Local Prohibit On/Off<br />

Request Local Prohibit mode<br />

Request Local Prohibit SetPoint<br />

Request All Off<br />

On/Off run state<br />

Mode state<br />

Setpoint state (both cool and heat)<br />

FanSpeed state<br />

Thermo On/Off state<br />

Temperature state of indoor<br />

Alarm state<br />

Local Prohibit On/Off state<br />

Local Prohibit mode state<br />

Local Prohibit SetPoint state<br />

LMAP<br />

LMAP 02<br />

Protocol converter<br />

between LON WORKS<br />

and M-NET<br />

LON WORKS<br />

LMAP<br />

M-NET<br />

CITY MULTI System<br />

Example of System Configuration<br />

System design made simple through integration of<br />

various devices into a total control configuration.<br />

208-230V<br />

60Hz<br />

Outdoor unit<br />

CITY MULTI<br />

Outdoor unit<br />

LON WORKS<br />

(78kdps)<br />

LMAP<br />

M-NET<br />

Indoor units<br />

Max. 50 indoor units<br />

Indoor units<br />

Indoor units<br />

Indoor units<br />

Indoor units<br />

Center<br />

control device<br />

Lighting<br />

Security<br />

Remote<br />

controller<br />

Remote<br />

controller<br />

Remote<br />

controller<br />

Remote<br />

controller<br />

Remote<br />

controller<br />

LON WORKS<br />

The building management system is connected to the CITY MULTI air conditioning system using LON WORKS , which is widely used on<br />

field networks, allowing for an open network and savings in construction to face.<br />

LON, LON WORKS and the Echelon logo are trademarks of<br />

Echelon Corporation registered in the United States and other countries.<br />

72


UP<br />

Building Air conditioning<br />

control system<br />

CENTRALIZED<br />

REMOTE CONTROLLER<br />

BACnet TM interface(PAC-YG31CDA)<br />

MITSUBISHI ELECTRIC's CITYMULTI can be easily connect to the building management system through BACnet. BACnet is the<br />

appropriate transmission method and used in many of the backbone networks and also it is easy to combine with other equipment<br />

corresponding to BACnet.<br />

One BACnet interface software manages up to 500 Groups/500 Indoor units. (10 G-50A/GB-50A units).<br />

(1) Example of Basic System Configuration.<br />

Central<br />

monitor<br />

BMS<br />

TM<br />

BACnet<br />

LAN<br />

G-50A<br />

M-NET<br />

WHM<br />

WHM<br />

TM<br />

BACnet interface software<br />

PAC-YG31CDA<br />

M-NET<br />

PAC-SC50KUA<br />

Power supply unit<br />

G-50A<br />

Web<br />

Browser<br />

(Optional)<br />

TG-2000A<br />

(Optional)<br />

73<br />

Operation<br />

Monitor<br />

Item<br />

On/Off (state)<br />

Operation mode (state)<br />

Fan Speed (state)<br />

Air direction (state)<br />

Room Temp.<br />

Filter Signal<br />

Alam signal<br />

Error Code<br />

Communication State<br />

On/Off (setup)<br />

Operation mode (setup)<br />

Fan Speed (setup)<br />

Air direction (setup)<br />

Set Temp.<br />

Filter Signal<br />

Prohibition of local operation (On/Off)<br />

Prohibition of local operation (Mode)<br />

Prohibition of local operation (filter reset)<br />

Prohibition of local operation (Set temp.)<br />

System Forced Off


CITY MULTI<br />

OPTIONAL PARTS<br />

R410A<br />

OPTIONAL PARTS FOR OUTDOOR UNITS<br />

For PU(H)Y, PURY series<br />

Description<br />

High static pressure motor<br />

Model<br />

PAC-KBU04MT-F<br />

Remarks<br />

~ 60Pa<br />

Note: In case of using PAC-KBU04MT-F, when carrying out intensive install of the outdoor unit, please extend on installation interval to 20mm or more.<br />

For PU(H)Y, PURY series<br />

Description Model Total capacity of indoor unit<br />

Branch pipe (Joint)<br />

Branch pipe (Header)<br />

CMY-Y102S-G<br />

CMY-Y102L-G1<br />

CMY-Y202-G1<br />

CMY-Y302-G1<br />

CMY-Y104-G<br />

CMY-Y108-G<br />

CMY-Y1010-G<br />

Note : Indoor unit capacities<br />

The capacity of an indoor unit is the same as the number used for its type identification.<br />

200 or below<br />

201-400<br />

401-650<br />

The 1st branch of P450~P650<br />

651 or above<br />

The 1st branch of P700~P1250<br />

For 4 branches<br />

For 8 branches<br />

For 10 branches<br />

For PUMY-P100, P125, P140YHM / PUMY-P100, P125, P140VHM<br />

Description<br />

Branch Pipe (2 Branch)<br />

Header<br />

Header<br />

Drain Socket<br />

Centralized Drain Pan<br />

Port Connector (ø9.52 → ø12.7 )<br />

Port Connector (ø15.88 → ø19.05)<br />

Air Protect Guide ( 2 pcs required )<br />

Model<br />

CMY-Y62-G-E<br />

CMY-Y64-G-E<br />

CMY-Y68-G-E<br />

PAC-SG61DS-E<br />

PAC-SG64DP-E<br />

PAC-SG73RJ-E<br />

PAC-SG75RJ-E<br />

PAC-SH63AG-E<br />

OPTIONAL EQUIPMENT FOR BC CONTROLLER<br />

BC Controller Model Junction pipe kit Branch pipe<br />

CMB-P104V-G, GB<br />

CMB-P105V-G<br />

CMB-P106V-G<br />

CMB-P108V-G, GA, GB<br />

CMB-P1010V-G, GA<br />

CMB-P1013V-G, GA<br />

CMB-P1016V-G, GA<br />

CMY-R160-J<br />

CMY-Y102S-G<br />

74


CITY MULTI<br />

OPTIONAL PARTS<br />

R410A<br />

OPTIONAL PARTS FOR INDOOR UNITS<br />

Description<br />

Decoration panel<br />

Multi-function casement<br />

High-efficiency filter element<br />

Air outlet shutter plate (1 set)<br />

4-way cassette type (PLFY-VCM / VAM)<br />

Model<br />

SLP-2AA<br />

PLP-6AA<br />

PAC-SG03TM-E<br />

PAC-SG01KF<br />

PAC-SG06SP-E<br />

Applicable capacity<br />

VAM<br />

–<br />

P32, P40, P50, P63, P80, P100, P125<br />

P32, P40, P50, P63, P80, P100, P125<br />

P80, P100, P125<br />

P32, P40, P50, P63, P80, P100, P125<br />

VCM<br />

P20, P25, P32, P40<br />

–<br />

–<br />

–<br />

–<br />

Description<br />

Decoration panel<br />

OA duct flange<br />

2-way cassette type (PLFY-VLMD)<br />

Model<br />

CMP-40VLW-B<br />

CMP-63VLW-B<br />

CMP-100VLW-B<br />

CMP-125VLW-B<br />

PAC-KH11OF<br />

Applicable capacity<br />

PLFY-VLMD-B<br />

P20, P25, P32, P40<br />

P50, P63<br />

P80, P100<br />

P125<br />

P20, P25, P32, P40, P50, P63, P80, P100<br />

1-way cassette type(PMFY-VBM)<br />

Description<br />

Model<br />

Applicable capacity<br />

Decoration panel PMP-40BM P20, P25, P32, P40<br />

Description<br />

Drain lift-up mechanism<br />

Long life filter<br />

Filter box<br />

Ceiling concealed type (PEFY-VMH)<br />

Model<br />

PAC-KE04DM-F<br />

PAC-KE32LAF-F<br />

PAC-KE86LAF<br />

PAC-KE88LAF<br />

PAC-KE89LAF<br />

PAC-KE85LAF<br />

PAC-KE63TB-F<br />

PAC-KE80TB-F<br />

PAC-KE140TB-F<br />

PAC-KE250TB-F<br />

Applicable capacity<br />

PEFY-VMH<br />

P40~P250<br />

–<br />

P40, P50, P63<br />

P71, P80<br />

P100, P125, P140<br />

P200, P250<br />

P40, P50, P63<br />

P71, P80<br />

P100, P125, P140<br />

P200, P250<br />

Ceiling concealed type (PEFY-VMM)<br />

Remarks<br />

Standard Filter is attached<br />

Necessary when long life filter is used<br />

Description<br />

Round shape duct flange<br />

Drain lift-up mechanism<br />

Model<br />

PAC-KE32EDF-F<br />

PAC-KE50EDF-F<br />

PAC-KE80EDF-F<br />

PAC-KE125EDF-F<br />

PAC-KE140EDF-F<br />

PAC-KE03DM-F<br />

Applicable capacity<br />

P20, P25, P32<br />

P40, V50<br />

P63, P71, P80<br />

P100, P125<br />

P140<br />

P20, P25, P32, P40, P50, P63, P71, P80, P100, P125, P140<br />

Description<br />

High efficiency filter<br />

Drain lift-up mechanism<br />

Ceiling suspended type (PCFY-VGM)<br />

Model<br />

PAC-SE80KF-E<br />

PAC-SE81KF-E<br />

PAC-SE82KF-E<br />

PAC-SE84DM-E<br />

PAC-SE85DM-E<br />

PAC-SE86DM-E<br />

Applicable capacity<br />

P40<br />

P63, P100<br />

P125<br />

P40<br />

P63<br />

P100, P125<br />

Description<br />

Long life filter<br />

Filter box<br />

Drain water lift-up kit<br />

Fresh air intake type (PEFY-VMH-E-F)<br />

Model<br />

PAC-KE88LAF<br />

PAC-KE89LAF<br />

PAC-KE85LAF<br />

PAC-KE80TB-F<br />

PAC-KE140TB-F<br />

PAC-KE250TB-F<br />

PAC-KE04DM-F<br />

Applicable capacity<br />

P80<br />

P140<br />

P200, P250<br />

P80<br />

P140<br />

P200/P250<br />

P80, P140, P200, P250<br />

75


Single phase Multi Split system (5HP)<br />

MSZ-FA series<br />

MSZ-GA series<br />

Branch Box<br />

MSZ-FA series<br />

SLZ series<br />

MFZ series<br />

PLA series<br />

PEAD series<br />

SEZ series<br />

MXZ-8A140VA Single phase, 50Hz<br />

*MXZ-8A140VA can NOT be connected with City Multi indoor units.<br />

Up to 8 indoor units<br />

can be connected !<br />

The Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series<br />

9000 of the International Standard Organization (ISO) based on a review of Quality , management for<br />

the production of refrigeration and air conditioning equipment.<br />

FM 33568 / ISO 9001;2000<br />

ISO Authorization System<br />

The ISO 9000 series is a plant authorization system relating to quality management as stipulated by<br />

the ISO. ISO 9001 certifies quality management based on the "design, development, production,<br />

installation and auxiliary services" for products built at an authorized plant.<br />

The Air Conditioning & Refrigeration Systems Works acquired environmental management system<br />

standard ISO 14001 certification.<br />

The ISO 14000 series is a set of standards applying to environmental protection set by the<br />

International Standard Organization (ISO).<br />

Certificate Number EC97J1227<br />

http://Global.MitsubishiElectric.com/<br />

MITSUBISHI ELECTRIC PRODUCTS ARE DISTRIBUTED BY...<br />

HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN<br />

http://Global.MitsubishiElectric.com<br />

MEE05K437<br />

New publication effective Jul. 2006<br />

<strong>Specifications</strong> subject to change without notice

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!