<strong>Guideline</strong><br />

<strong>Guideline</strong> for <strong>Cosmetic</strong> <strong>and</strong> surface issues of<br />

7/<strong>16</strong> Coaxial <strong>Connector</strong>s<br />

RL-CS-200b<br />

Rev.: 6<br />

page: 3 of 5<br />

R&D / RF & TEST LAB<br />

<strong>Guideline</strong> for <strong>Cosmetic</strong> issues of 7/<strong>16</strong> Coaxial <strong>Connector</strong>s<br />

PIM-Ring<br />

(back side)<br />

PIM-Ring<br />

(front side)<br />

PIM-Ring (back side)<br />

No hit places allowed<br />

Homogenous chamfer is required<br />

(no manuell rework allowed)<br />

acceptable<br />

Not acceptable<br />

3.3 3.4<br />

PIM-Ring (front side)<br />

acceptable<br />

Not acceptable<br />

3.5 3.6<br />

Minor damages are acceptable if not perceptible with fingernail - test!<br />

Created by I.Sarfert<br />

RL-CS-200b-<strong>Guideline</strong>_7_<strong>16</strong>_<strong>Cosmetic</strong><br />

Seite 3 von 5<br />