HVAC<br />

Controls<br />

Tekmar<br />

Boiler Controls<br />

264<br />

The Boiler Control 264 is a microprocessor-based<br />

four stage boiler control. The 264 can provide either<br />

outdoor reset and setpoint operation or outdoor<br />

reset and DHW operation. The 264 stages and has<br />

Equal Run Time Rotation of the boilers and also<br />

operates the system pump and individual boiler<br />

pumps. One, two, three and four stage on / off<br />

boilers can be operated. The 264 also has options<br />

for fixed lead and fixed last rotation sequences. A<br />

contact is also available for either a combustion air<br />

damper or external alarm.<br />

Part No. Item List<br />

TEK264 264 $1,382.35<br />

268<br />

The Boiler Control 268 is a microprocessor-based<br />

nine stage boiler control. The 268 can provide either<br />

outdoor reset and setpoint operation or outdoor<br />

reset and DHW operation. The 268 stages and has<br />

Equal Run Time Rotation of the boilers and also<br />

operates the system pump and individual boiler<br />

pumps. One, two, three and four stage on / off<br />

boilers can be operated. The 268 also has options<br />

for fixed lead and fixed last rotation sequences. A<br />

contact is also available for either a combustion air<br />

damper or external alarm. The control can provide<br />

outdoor reset using an outdoor sensor or the control<br />

can accept a 0 -10 V (dc) signal from an EMS / BAS<br />

to establish the required water temperature.<br />

Part No. Item List<br />

TEK268 268 $2,383.36<br />

269<br />

The One Stage Steam Control 269 is a<br />

microprocessor based steam boiler control. Based<br />

on outdoor temperature, the 269 adjusts the on time<br />

of a steam boiler or valve. The 269 has a<br />

condensate return sensor to measure the point at<br />

which steam is established and also to provide a<br />

Lockout Differential for ensuring all latent heat is<br />

extracted from the steam before the cycle starts<br />

again. One or two indoor sensors can provide indoor<br />

temperature feedback to the control. An auxiliary<br />

relay is provided for operation of a condensate<br />

pump.<br />

Part No. Item List<br />

TEK269.1STAGE 269 $2,079.80<br />

Heating Controls - Stand Alone<br />

362<br />

The Mixing Control 362 is a microprocessor-based<br />

mixing outdoor reset control that can operate either<br />

a floating action 2, 3 or 4-way mixing valve or a<br />

permanent capacitor, impedance protected or<br />

equivalent pump through the variable speed output.<br />

A tekmar Indoor or Slab Sensor, Digital RTU or<br />

Zone Control can be connected to provide indoor<br />

temperature feedback from single or multiple zones.<br />

The 362 can control the boiler to provide Boiler Load<br />

Reset and boiler protection. The 362 has two modes<br />

of operation. Mode 1 operation is for heating<br />

applications, whereas mode 2 operation is snow<br />

melting applications. If mode 2 is selected, an<br />

optional Snow Melt Kit (SMK) is available.<br />

Part No. Item List<br />

TEK362 362 $1,639.50<br />

Setpoint Controls<br />

356<br />

The Mixing Control 356 is a microprocessor-based<br />

outdoor reset control designed to operate a<br />

permanent capacitor, impedance protected or<br />

equivalent pump at varying speeds. The 356 also<br />

provides for boiler minimum protection and boiler<br />

operation.<br />

Part No. Item List<br />

TEK356 356 $541.90<br />

Mixing Expansion Modules<br />

The Mixing Expansion Module 440 provides a<br />

system pump output and a single mixing output for<br />

either a variable speed injection pump or floating<br />

action mixing valve. The 440 cannot operate by<br />

itself and requires the use of a tN4 System Control<br />

that is capable of operating a Mixing Expansion<br />

Module.<br />

Part No. Item List<br />

TEK440 440 $499.25<br />

Outdoor Reset Modules<br />

421<br />

The Mixing Reset Module 421 provides outdoor<br />

reset to a hydronic heating system in order to<br />

maximize comfort and efficiency. The 421 can<br />

operate a single on / off boiler and a single mix<br />

water temperature. To operate two mixing devices,<br />

a Mixing Expansion Module must be connected to<br />

the 421. The mix output can operate a floating<br />

action mixing valve or a variable speed injection<br />

pump.<br />

Part No. Item List<br />

TEK421 421 $858.01<br />