HVAC<br />
Controls<br />
Tekmar<br />
Boiler Controls<br />
264<br />
The Boiler Control 264 is a microprocessor-based<br />
four stage boiler control. The 264 can provide either<br />
outdoor reset and setpoint operation or outdoor<br />
reset and DHW operation. The 264 stages and has<br />
Equal Run Time Rotation of the boilers and also<br />
operates the system pump and individual boiler<br />
pumps. One, two, three and four stage on / off<br />
boilers can be operated. The 264 also has options<br />
for fixed lead and fixed last rotation sequences. A<br />
contact is also available for either a combustion air<br />
damper or external alarm.<br />
Part No. Item List<br />
TEK264 264 $1,382.35<br />
268<br />
The Boiler Control 268 is a microprocessor-based<br />
nine stage boiler control. The 268 can provide either<br />
outdoor reset and setpoint operation or outdoor<br />
reset and DHW operation. The 268 stages and has<br />
Equal Run Time Rotation of the boilers and also<br />
operates the system pump and individual boiler<br />
pumps. One, two, three and four stage on / off<br />
boilers can be operated. The 268 also has options<br />
for fixed lead and fixed last rotation sequences. A<br />
contact is also available for either a combustion air<br />
damper or external alarm. The control can provide<br />
outdoor reset using an outdoor sensor or the control<br />
can accept a 0 -10 V (dc) signal from an EMS / BAS<br />
to establish the required water temperature.<br />
Part No. Item List<br />
TEK268 268 $2,383.36<br />
269<br />
The One Stage Steam Control 269 is a<br />
microprocessor based steam boiler control. Based<br />
on outdoor temperature, the 269 adjusts the on time<br />
of a steam boiler or valve. The 269 has a<br />
condensate return sensor to measure the point at<br />
which steam is established and also to provide a<br />
Lockout Differential for ensuring all latent heat is<br />
extracted from the steam before the cycle starts<br />
again. One or two indoor sensors can provide indoor<br />
temperature feedback to the control. An auxiliary<br />
relay is provided for operation of a condensate<br />
pump.<br />
Part No. Item List<br />
TEK269.1STAGE 269 $2,079.80<br />
Heating Controls - Stand Alone<br />
362<br />
The Mixing Control 362 is a microprocessor-based<br />
mixing outdoor reset control that can operate either<br />
a floating action 2, 3 or 4-way mixing valve or a<br />
permanent capacitor, impedance protected or<br />
equivalent pump through the variable speed output.<br />
A tekmar Indoor or Slab Sensor, Digital RTU or<br />
Zone Control can be connected to provide indoor<br />
temperature feedback from single or multiple zones.<br />
The 362 can control the boiler to provide Boiler Load<br />
Reset and boiler protection. The 362 has two modes<br />
of operation. Mode 1 operation is for heating<br />
applications, whereas mode 2 operation is snow<br />
melting applications. If mode 2 is selected, an<br />
optional Snow Melt Kit (SMK) is available.<br />
Part No. Item List<br />
TEK362 362 $1,639.50<br />
Setpoint Controls<br />
356<br />
The Mixing Control 356 is a microprocessor-based<br />
outdoor reset control designed to operate a<br />
permanent capacitor, impedance protected or<br />
equivalent pump at varying speeds. The 356 also<br />
provides for boiler minimum protection and boiler<br />
operation.<br />
Part No. Item List<br />
TEK356 356 $541.90<br />
Mixing Expansion Modules<br />
The Mixing Expansion Module 440 provides a<br />
system pump output and a single mixing output for<br />
either a variable speed injection pump or floating<br />
action mixing valve. The 440 cannot operate by<br />
itself and requires the use of a tN4 System Control<br />
that is capable of operating a Mixing Expansion<br />
Module.<br />
Part No. Item List<br />
TEK440 440 $499.25<br />
Outdoor Reset Modules<br />
421<br />
The Mixing Reset Module 421 provides outdoor<br />
reset to a hydronic heating system in order to<br />
maximize comfort and efficiency. The 421 can<br />
operate a single on / off boiler and a single mix<br />
water temperature. To operate two mixing devices,<br />
a Mixing Expansion Module must be connected to<br />
the 421. The mix output can operate a floating<br />
action mixing valve or a variable speed injection<br />
pump.<br />
Part No. Item List<br />
TEK421 421 $858.01<br />
198<br />