Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
BlueComfort Premium<br />
DeLuxe Integration<br />
DeLuxe Integration<br />
The DeLuxe has all the features of the Basic integration but additionally allows the integration of a water boiler<br />
as well as further fan blowers or radiators into the system. It therefore provides the highest comfort in heating and<br />
sanitary water supply. The mixing valve limits the water temperature in the A / C loop to 60° C. A summer / winter switch<br />
allows heating of the boiler in summer while the A / C system is cooling the cabins at the same time.<br />
C<br />
B<br />
I<br />
D<br />
G<br />
E<br />
F<br />
A<br />
H<br />
For a perfect integration Webasto<br />
recommends Isotemp double coil boilers.<br />
Visit www.indelwebastomarine.com<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
I<br />
Water Heater Produces hot (approx. 80° C) water when system switches to heating<br />
Water Pump Circulates the water<br />
A / C Chiller Unit Cools down the water when system switches to cooling<br />
Chiller Control Controls the complete A / C system and the water heater<br />
Starts the compressor when cooling is necessary<br />
Starts the heater when heating is necessary<br />
Air Handler Warms up or cools down returning air<br />
3 Way Valve Switches between cooling or heating loop<br />
Water Boiler Heats up the sanitary water<br />
Blowers or radiators can optionally be used in areas with extra high heating demand<br />
(e. g. windscreen for demisting)<br />
Summer / Winter switch Allows separate boiler operation in summer mode<br />
BlueComfort Accessories<br />
For the chilled water system, the following key components are needed as well:<br />
3 way motor valve Basic Integration DeLuxe Integration<br />
Thermo 90 ST chiller & DBW 2010 / 2016 / 2020<br />
use 3 / 4” motor valve WBCL000776<br />
Thermo 230 / 300 / 350 use 1 1 / 2“ or 2” motor valve,<br />
e.g Belimo R340BL / R350BL + SR230A motor<br />
Thermo 90 ST chiller & DBW 2010 / 2016 / 2020<br />
use 3 / 4” motor valve WBCL000776<br />
Thermo 230 / 300 / 350 use 1 1 / 2”or 2” motor valve,<br />
e.g. Belimo R340BL / R350BL + SR230A motor<br />
thermostatic mixing valve Basic Integration DeLuxe Integration<br />
Thermo 90 ST use 3 / 4” mixing valve<br />
DBW 2010 / 2016 / 2020 use 3 / 4” mixing valve<br />
Thermo 230 / 300 / 350 use 1 1 / 2“ mixing valve<br />
BlueComfort Solutions<br />