Lubrication<br />

Grease valves<br />

For high-speed operation, e.g. with fan<br />

bearing arrangements, <strong>FAG</strong> supply RSV<br />

grease valves upon request, fig. 7.<br />

Grease valves for <strong>SNV</strong> housings of design<br />

G944A* must be listed separately in<br />

the order. RSV5 or RSV6 grease valves<br />

are used for bearings with adapter sleeves<br />

while RSV2 or RSV3 valves are used for<br />

bearings with cylindrical bore.<br />

7: RSV grease valve<br />

Oil lubrication<br />

The <strong>SNV</strong> housings are designed for<br />

both oil sump and circulation oil lubrication.<br />

The housings are spacious with oil<br />

collecting pockets in the base, oil inlet<br />

and outlet holes, holes for connecting oil<br />

level gauges and temperature sensors.<br />

Connection dimensions fig. 8.<br />

In the case of oil sump lubrication a<br />

minimum oil level must be maintained<br />

(h3 dimension in fig. 8). If <strong>FAG</strong> two-lip<br />

seals are used, a certain leakage must be<br />

taken into account. Leakage is inevitable<br />

with split seals and with seals which are<br />

not spring-preloaded. To keep the leakage<br />

rate down, the seal contact surface on the<br />

shaft should have the following quality:<br />

hardness at least 55 HRC,<br />

ground twist-free with R a = 0.2 µm to<br />

max. 0.5 µm.<br />

b<br />

RSV5<br />

RSV6<br />

RSV2<br />

RSV3<br />

The joint between housing top and<br />

base must be sealed with a thin layer of a<br />

commercial sealing compound (permanent<br />

elasticity). In the case of housings<br />

closed at one end, the groove bottom<br />

must also be filled with the sealing compound.<br />

Technically-speaking, an oil-proof design<br />

is only possible with a spring-preloaded,<br />

unsplit radial shaft seal. Please<br />

note: the housing must be ventilated in<br />

the case of oil sump lubrication (e.g. closing<br />

the inlet hole with a ventilation plug).<br />

Please contact the <strong>FAG</strong> advisory service<br />

about design and availability.<br />

Grease valve Width Grease valve Width<br />

b<br />

<strong>FAG</strong> mm <strong>FAG</strong> mm<br />

RSV205 to 211 8 RSV305 to 308 8<br />

RSV212 to 218 10 RSV309 to 313 10<br />

RSV219 to 222 13 RSV314 to 316 13<br />

RSV224 to 232 15 RSV317 to 322 15<br />

RSV324 to 332 16<br />

b<br />

<strong>FAG</strong> · 10