FAG SNV Plummer Blocks - Reliance Bearing
FAG SNV Plummer Blocks - Reliance Bearing
FAG SNV Plummer Blocks - Reliance Bearing
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Lubrication<br />
Grease valves<br />
For high-speed operation, e.g. with fan<br />
bearing arrangements, <strong>FAG</strong> supply RSV<br />
grease valves upon request, fig. 7.<br />
Grease valves for <strong>SNV</strong> housings of design<br />
G944A* must be listed separately in<br />
the order. RSV5 or RSV6 grease valves<br />
are used for bearings with adapter sleeves<br />
while RSV2 or RSV3 valves are used for<br />
bearings with cylindrical bore.<br />
7: RSV grease valve<br />
Oil lubrication<br />
The <strong>SNV</strong> housings are designed for<br />
both oil sump and circulation oil lubrication.<br />
The housings are spacious with oil<br />
collecting pockets in the base, oil inlet<br />
and outlet holes, holes for connecting oil<br />
level gauges and temperature sensors.<br />
Connection dimensions fig. 8.<br />
In the case of oil sump lubrication a<br />
minimum oil level must be maintained<br />
(h3 dimension in fig. 8). If <strong>FAG</strong> two-lip<br />
seals are used, a certain leakage must be<br />
taken into account. Leakage is inevitable<br />
with split seals and with seals which are<br />
not spring-preloaded. To keep the leakage<br />
rate down, the seal contact surface on the<br />
shaft should have the following quality:<br />
hardness at least 55 HRC,<br />
ground twist-free with R a = 0.2 µm to<br />
max. 0.5 µm.<br />
b<br />
RSV5<br />
RSV6<br />
RSV2<br />
RSV3<br />
The joint between housing top and<br />
base must be sealed with a thin layer of a<br />
commercial sealing compound (permanent<br />
elasticity). In the case of housings<br />
closed at one end, the groove bottom<br />
must also be filled with the sealing compound.<br />
Technically-speaking, an oil-proof design<br />
is only possible with a spring-preloaded,<br />
unsplit radial shaft seal. Please<br />
note: the housing must be ventilated in<br />
the case of oil sump lubrication (e.g. closing<br />
the inlet hole with a ventilation plug).<br />
Please contact the <strong>FAG</strong> advisory service<br />
about design and availability.<br />
Grease valve Width Grease valve Width<br />
b<br />
<strong>FAG</strong> mm <strong>FAG</strong> mm<br />
RSV205 to 211 8 RSV305 to 308 8<br />
RSV212 to 218 10 RSV309 to 313 10<br />
RSV219 to 222 13 RSV314 to 316 13<br />
RSV224 to 232 15 RSV317 to 322 15<br />
RSV324 to 332 16<br />
b<br />
<strong>FAG</strong> · 10