Material- Materialname Bezeichnung H2O (%) DK-Wert Brech- Reissfestigkomponenten<br />

der Linse 35° 20° index keit (kp/cm 2 )<br />

Poly-HEMA<br />

HEMA/ ? Benz-38 Ratio-38/ IN4/ TD4/ TP4 38,6 9 1 1,430 1<br />

HEMA/ ? PolyHema Ascon-40/Hydroflex 38 9 8 1,445 6<br />

HEMA/ Polymacon Soflens/Seequence/ 38,6 10 1 8 3/4 1,437 6 6,5<br />

EGDMA BH Thin/Hydron 12 1 1,435 6<br />

HEMA/ ? Tefilcon Cibasoft/Weicon 37,5 10 8 5 1,434 6 6,5 1<br />

HEMA-Copolymere<br />

HEMA/GMA Benz G3x Vivo/Vario/Techno 49 16 1 1,422 1<br />

Benz G5x Balance/Techno/Visell/ 59 22 1<br />

= Hioxifilcon A Extreme H2O/OP-58K<br />

HEMA/DAA/MA/ Bufilcon A Hydrocurve-2 bifocal 45 13 1 12 5 1,43 6<br />

TMPTMA<br />

Bufilcon A Hydrocurve-3 toric 55 18 1 16 5 1,41 6<br />

HEMA/BMA/ Deltafilcon A Amsof/Aquaflex 43 10 5<br />

TMPTMA Deltafilcon B Aquasight 43 10 5<br />

HEMA/MMA/ Etafilcon Hydromarc/Visimarc 43 9 2<br />

TMPTMA Etafilcon A Acuvue/Surevue/ 58 28 1 20 5 1,40<br />

Adypi E<br />

HEMA/MA(?)/ Methafilcon A Sunflex/Eclipse 55 20 1 18 1/5 10,5<br />

EGDMA Frequency55 und XCEL<br />

Methafilcon B Hydrasoft Toric 55 24 1<br />

HEMA/MA/EGDMA/ Genfilcon A Vistavue 48 13 1 1,43<br />

TMPTMA<br />

1,4151<br />

1


Material- Materialname Bezeichnung H2O (%) DK-Wert Brech- Reissfestigkomponenten<br />

der Linse 35° 20° index keit (kp/cm 2 )<br />

HEMA/EOEMA Phemfilcon A Durasoft-2 38 11 1 8 5<br />

Phemfilcon A Durasoft-3/Freshlook 55 20 1/2 16 5<br />

HEMA/HBMA ? Govafilcon A Menicon Soft MA 37,5 10 1 1,438 6<br />

HEMA/VP/MA Droxifilcon A Accugel/Accusoft 47 11 2<br />

TEGDMA<br />

HEMA/VP/ Hefilcon A Alges/Flexlens 45 132 125 EGDMA Hefilcon B Optima Toric 45 132 125 1,4336 Hefilcon C Optomal 56 UV 57 28 1<br />

17 1<br />

HEMA/VP/MA/ Perfilcon A Permalens 71 42 1/3 34 1/3/5 1,380 6 1,2<br />

EGDMA<br />

HEMA/VP/ Tetrafilcon A BH-Classic/Preference Tori 42,5 13 1 1,43 1<br />

MMA/DVB Tetrafilcon B Aquaflex-58 58<br />

HEMA/VP/ Vifilcon A Softcon/Focus/ 55 20 1 16 5 1,407 1<br />

EGDMA EasyLens<br />

HEMA/PVP Ocufilcon D Biomedics 55/Dispo/ 55 23 1 19 1<br />

Activ55/Fit58/Comfort55<br />

Hema-freie Materialien<br />

MMA/VP Alcantara Incanto 78 64 1(?) 1,37 1 19<br />

Biogel-60 Prolens Biogel 60/Conso 62 61 1 26 1 20 1 1,404 1 18,7 1<br />

Biogel-75 Prolens Biogel-75 73 1 47 1 33 1 1,385 1 12,5 1<br />

Biogel-80 Conso-80vT 78 1 49 1 40 1 1,373 1 9,6 1<br />

2


Material- Materialname Bezeichnung H2O (%) DK-Wert Brech- Reissfestigkomponenten<br />

der Linse 35° 20° index keit (kp/cm 2 )<br />

MMA/VP ES-70 Lunelle 70 35 1 1,39 6 18<br />

ES-73 Rythmic/ReView/Fréquence 73 45 1 35 1 1,38<br />

Hilafilcon A SofLens One Day 70<br />

Hilafilcon B SofLens Comfort 59 22 1<br />

Lidofilcon A 70 39 3 31 3 1,388 6 18,7<br />

Lidofilcon B B&L CW-79 / 79 57 48 1/3 1,367 6<br />

Netrafilcon A Gentle touch 65 34 1<br />

Ofilcon A Durasoft-4 74 40 1<br />

Scafilcon A Cibasoft S-75 71 36 1/3 31 3 1,384 1 14 1<br />

Surfilcon A Permaflex 74 43 1 1,385 1<br />

Vasurfilcon Precision UV 73,6 38 1<br />

Xylofilcon A/ Igel 67 Dyna-67 67,5 30 1/4 17 1/4 1,39 1 9<br />

Xylofilcon C/ Igel-58 Galifa IN5 /Techno- 58 20 1 13 1 1,41 1 15<br />

lens A.S.-N<br />

-- Contaflex-58 58 22 1 1,405 1 11,3<br />

-- Contaflex-78 78,5 42 1 1,368 1 5<br />

-- Geaflex-70 70 43 1 1,388 6<br />

-- Weflex-50-D 50 23 1<br />

-- Weflex-55 55 23 1 1,409 1<br />

-- Weicon-CE 60 28 1 1,404 1 29 1<br />

3


Material- Materialname Bezeichnung H2O (%) DK-Wert Brech- Reissfestigkomponenten<br />

der Linse 35° 20° index keit (kp/cm 2 )<br />

Phosphorylcholin Omafilcon A Proclear compatibles 62 41 1<br />

Proclear sphär/tor 59 36 1<br />

PVA Atlafilcon A Excelens 64 27 1 1,386 1<br />

Nelfilcon A Dailies 69 26 1<br />

MMA/GMA/ Crofilcon A CSI-Clarity / 38,5 13 1 1,43 1<br />

TEGDMA CSI-Clarity Toric<br />

DMAA/MMA/VP Mipafilcon A Menicon Soft-72 72,3 44 1 1,378 1<br />

BHCM/VP Alphafilcon A SofLens-66/SofLens-66 Toric 66 30 1<br />

Silikon- Elastofilcon A Silflex/Silsight 420 1,435 1<br />

kautschuk<br />

Silikon/Hydrogel Balafilcon A PureVision 36 99 1,41<br />

Hart-Weich-Linsenkombination<br />

Lotrafilcon A Focus Night&Day 24 140 1,42<br />

Synergicon A SoftPerm 0,2 (Zentr.) 14 1 (Zentrum)<br />

25 (Periph.) 5,5 1 (Peripherie)<br />

4


Materialkomponenten:<br />

Monomere: Verbessert: Nachteile:<br />

BHCM Butylhydroxycyclomethacrylat<br />

BMA Butylmethacrylat Flexibilität, Weichheit Hydrophobie<br />

DAA Diacetonacrylamid<br />

DMAA Dimethylacrylamid<br />

EOEMA Aethoxyäthylmethacrylat Flexibilität, Weichheit Hydrophobie<br />

GMA Glycerylmethacrylat Wasserbindungsvermögen<br />

HBMA Hydroxybutylmethacrylat Flexibilität, Weichheit<br />

HEMA 2-Hydroxyäthylmethacrylat Benetzbarkeit, Wasseraufnahme,<br />

Gaspermeabilität<br />

MA Methacrylsäure Wasseraufnahme pH-Empfindlichkeit, Oberflächenladung,<br />

erhöht Eiweissablagerungen<br />

MMA Methylmethacrylat Härte, Verarbeitbarkeit Hydrophobie<br />

MPE Methylpropansäureester<br />

PC Phosphorylcholin Wasserbindungsvermögen<br />

PVA Polyvinylalkohol<br />

VBL Vinylbutyrolactam<br />

VP N-Vinylpyrrolidon Benetzbarkeit, Wasseraufnahme Verfärbung, erhöhte Wasserverdunstung,<br />

erhöht Lipidablagerungen<br />

Vernetzer:<br />

DVB Divinylbenzen<br />

EGDMA Aethylenglycol-Dimethacrylat<br />

TEGDM Tetraäthylenglycol-Dimethacrylat<br />

TMPTMA Trimethylpropan-Trimethacrylat<br />

Literaturquellen:<br />

1 Herstellerangaben<br />

2 Dabezies O.H. Contact Lenses. The CLAO Guide to Basic Science and Clinical Practice, Grune & Stratton, Orlando, 1984 (Update 2)<br />

3 Morris J./Fatt I. A Survey of Gas-permeable Contact Lenses, Optician 174 1977), 27-29<br />

4 Phillips A.J./Stone J. Contact Lenses. Butterworths,London, third edition, 1989<br />

5 White O.D./Scott C Contact Lenses and Solutions Summary,Contact Lens Spectrum, June 1993<br />

6 Teuerle W. Neue Ergebnisse zur Brechzahlberechnung von Hydrogelen, Dtsch. Opt. Ztg. Heft 1, 1989<br />

Zusammenstellung Dr. E. Bürki, Thun, August 2001<br />