12.11.2014 Views

OT-Systems

OT-Systems

OT-Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

40ı41<br />

Technical specifications<br />

6 5 4 d IP65 a<br />

Reference 6 Joule, 960 °C o<br />

TOC Control gear Lamps L D<br />

options<br />

···E ···ED W mm mm kg<br />

Fidesca PM RV 228/54··· 52 598··· ···04 2 x 28/54 1248 1188 13,4<br />

Fidesca PM RV 254··· 52 600··· ···05 2 x 54 1248 1188 13,6<br />

Fidesca PM RV 235/49··· 52 599··· ···04 ···05 2 x 35/49 1548 1488 16,6<br />

Fidesca PM RV 280··· 52 601··· ···04 2 x 80 1548 1488 16,8<br />

Fidesca PM RV 328/54··· 52 602··· ···04 3 x 28/54 1248 1188 17,9<br />

Fidesca PM RV 354 1x··· 52 605··· ···05 3 x 54 1248 1188 18,0<br />

Fidesca PM RV 354··· 52 606··· ···05 3 x 54 1248 1188 18,2<br />

Fidesca PM RV 335/49··· 52 603··· ···04 ···05 3 x 35/49 1548 1488 20,7<br />

Fidesca PM RV 349 1x··· 52 604··· ···05 3 x 49 1548 1488 20,8<br />

Fidesca PM RV 380··· 52 607··· ···04 3 x 80 1548 1488 20,7<br />

C0-C180<br />

Fidesca PM RV 235/49<br />

UTE: 0,70 C<br />

DIN 5040: A50<br />

CIBSE: BZ 4/1.25/BZ 3<br />

NBN L 14-002: BZ 3<br />

Dynamic RGB colour lighting control<br />

Dynamic colour lighting control for a calming<br />

light atmosphere, especially for operations<br />

with partial anaesthesia.<br />

Adjustable specular reflectors<br />

The specular reflectors can be adjusted<br />

individually by up to +/– 30° from vertical.<br />

Planning software for mounting frames Fidesca luminaire series<br />

When using mounting frames, luminaires of Additional versions of our Fidesca luminaire<br />

the Fidesca PM series may be installed as series can be found in the separate product<br />

individual luminaires, as continuous lines or family brochure.<br />

as right-angled configurations in suspended<br />

ceilings.<br />

Mounting frames made of extruded aluminium<br />

sections are powder-coated in white and fully<br />

assembled with support brackets and distance<br />

pieces. Only angular mounting frames are<br />

packed with separate profile side pieces on<br />

one side and can easily be screwed together<br />

at installation site.<br />

Easy configuration including parts list with the<br />

"TX-WIN Cleanroom" software tool. Available<br />

for downloading at www.trilux.eu.<br />

Mechanical properties<br />

• Luminaire cover made of highly-resistant laminated<br />

safety glass, providing optimum protection against<br />

shattering.<br />

• Luminaire body thanks to IP 65 protection rating is<br />

dust-proof and virtually bacteria-proof: Smooth,<br />

easy-to-clean and disinfect surfaces, thus suited for<br />

use in rooms with increased hygienic requirements<br />

such as in operating theatres and adjacent areas.<br />

• Use of mounting frames simplifies luminaire<br />

installation and the closing of the surrounding ceiling<br />

before actual installation of luminaires, ensures a<br />

visually clean transition to ceiling and seals the space<br />

above the suspended ceiling off from the room in a<br />

manner that is compatible with good hygiene.<br />

Optical system<br />

• Specular reflectors, individually adjustable for each<br />

lamp by up to +/– 30° from vertical, resulting in<br />

individual and flexible adaptation of light distribution<br />

to the given conditions. For instance, proportionally<br />

more light may be directed to where it is needed,<br />

i.e. the operating field.<br />

• Specular reflector with asymmetric light distribution,<br />

made of reflection-intensifying aluminium.<br />

• An optical system positioned under the<br />

T5 fluorescent lamp serves to eliminate glare<br />

and optimises the luminaire's light output ratio.<br />

• Glass pane with stylish fine-grained surface for<br />

eliminating uncontrolled reflections when using<br />

laser technology. Resistant against disinfectants<br />

and UV radiation, with white-coated steel frame,<br />

safely retained without frame by means of internal<br />

spring-tensioned clips in the luminaire body.<br />

Technical features<br />

• Switching and dimming of every individual lamp,<br />

facilitating different lighting scenarios or dynamic<br />

colour light control on RGB basis.<br />

• Green light insert for use in operating theatres<br />

especially for minimal-invasive surgery with low<br />

illuminance, available as an optional accessory.<br />

• Emergency light insert for integrating the<br />

Fidesca-PM into the emergency light system,<br />

available as an optional accessory.<br />

Electrical connection<br />

• Luminaires supplied ready for connection, prepared<br />

for separate electric circuits per lamp. As a result, it<br />

is possible to actuate not only every luminaire but<br />

every single lamp within a luminaire, and there is the<br />

possibility to connect the lighting system into the<br />

central <strong>OT</strong> room control system in integrated <strong>OT</strong><br />

systems.<br />

• Each luminaire has 2 cable glands for mains supply<br />

and further wiring. Additional cable glands available<br />

as an accessory.<br />

Control gear options<br />

Also suitable for areas with infra-red controls.<br />

... E with electronic control gear.<br />

···28/54··· and ···35/49··· in Multi-Lamp technology for<br />

operation of T5 lamps with different wattages..<br />

···ED With dimmable electronic control gear with 1-10 V<br />

interface, optionally available with DALI interface.<br />

···1 x ED External lamp circuits with electronic control<br />

gear, internal lamp circuit with dimmable electronic<br />

control gear with 1-10 V interface.<br />

Multi-Lamp ECG<br />

Electronic control gear in<br />

Multi-Lamp technology allows<br />

for operation of T5 lamps with<br />

different wattages.<br />

T5