More innovation. More protection. More safety.<br />

<strong>The</strong> HUBBELL AUTOGUARD Safety Advantage<br />

Reverse Wire Safety Feature<br />

<strong>The</strong> <strong>Hubbell</strong> GFR will not have power at both<br />

the face and downstream if the line and load<br />

are reverse wired. Additionally, the unit will<br />

not be able to reset under a reversed wiring<br />

condition. Typically if the line and load are<br />

reversed, there will be power at the face and<br />

the end user would assume there is ground<br />

fault protection at the point of use.<br />

Surge Withstand<br />

Underwriters Laboratories requires all<br />

ground fault receptacles to meet a 6kV,<br />

3kA surge test without compromising the<br />

people protection functionality of the unit.<br />

If a unit cannot meet this performance<br />

requirement, it must shut down and become<br />

totally inoperable. <strong>Hubbell</strong> meets the surge<br />

withstand requirement by design without<br />

relying on a non-operational lock out mode to<br />

meet the test. <strong>Hubbell</strong> opted to build a more<br />

robust device by incorporating a heavy duty<br />

Metal Oxide Varistors (MOV) into the product.<br />

This MOV was specifically designed into the<br />

<strong>Hubbell</strong> <strong>GFCI</strong> receptacle with the intention<br />

of passing the UL 6 kV, 3kA surge immunity<br />

test while continuing to provide power and<br />

protection to the face and downstream loads.<br />

Three provisions for providing<br />

protection<br />

Continuous electronic sensing & testing,<br />

utilizing diagnostic software – immediate<br />

indication if unit has lost the ability to<br />

protect<br />

Traditional testing mode by manually<br />

operating the “test and reset” buttons<br />

Traditional auto-sensing mode for<br />

immediate interruption for a ground fault<br />

condition<br />

10,000 Amp Short Circuit<br />

Rating<br />

AUTOGUARD was designed to withstand the<br />

stringent applications where a potential for<br />

high current short circuit conditions exist such<br />

as industrial power centers, disconnects and<br />

motor centers.<br />

<strong>The</strong> <strong>Hubbell</strong> Exclusive Self Test <strong>GFCI</strong> is a<br />

comprehensive approach to testing.<br />

Reverse Wire Safety Feature assures unit will<br />

not be able to reset under a reversed wiring<br />

condition.<br />

Meets UL943 performance requirements by<br />

design, not by lockout<br />

Over 115 YEARS OF DESIGN INNOVATION &<br />

CUSTOMER SOLUTION<br />

<strong>GFCI</strong><br />

New UL 943<br />

2002<br />

<strong>GFCI</strong><br />

with LED<br />

Functionality<br />

2004<br />

AUTOGUARD<br />

Self Test <strong>GFCI</strong><br />

2005