13.11.2014 Views

Immersion Photometer S

Immersion Photometer S

Immersion Photometer S

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Immersion</strong><br />

<strong>Photometer</strong> S


CASSY <strong>Immersion</strong> <strong>Photometer</strong> S<br />

The new CASSY <strong>Immersion</strong> <strong>Photometer</strong> S<br />

The new immersion photometer measures: concentration, transmission rates, absorbance and turbidity directly from the<br />

sample under investigation - without the need for cuvettes.<br />

• Measure transmission and absorbance at<br />

5 different wavelengths<br />

• Determine up to 17 different pollutants in water<br />

(nitrate, phosphate, chloride, sulphate, hardness, iron...<br />

see table of reagent kits below)<br />

• Measure turbidity<br />

• Long-term measurements (e.g. turbidity in bio-reactors)<br />

• Investigate reaction kinetics<br />

• Can be used with all members of the CASSY-family.<br />

(Sensor-CASSY, Pocket-CASSY, Mobile-CASSY)<br />

Necessary accessories<br />

CASSY-System<br />

Analysing water samples<br />

524 006 Pocket-CASSY or<br />

524 009 Mobile-CASSY or<br />

524 010 Sensor-CASSY with RS232 or<br />

524 010USB Sensor-CASSY with USB-interface<br />

524 200 Software „CASSY Lab“<br />

Reagents<br />

666 2600 Photometry Reagent Kit 1 -<br />

with storage-case and accessories<br />

666 2603 Photometry Reagent Kit 1<br />

666 2601 Photometry Reagent Kit 2 -<br />

with storage-case and accessories<br />

666 2604 Photometry Reagent Kit 2<br />

666 2602 Empty case, with inlay<br />

additionally recommended:<br />

666 2605 Holder for photometer<br />

Content of the reagent kits<br />

(sufficient for approx. 100 measurements each)<br />

Kit Catalogue-No. Chemical Tablet Measuring range<br />

1 AQ4512580 ammonia No.1<br />

1 AQ4512590 ammonia No.2<br />

0 … 3.00 mg/l<br />

1 AQ4515910 chloride T 1<br />

1 AQ4515920 chloride T 2<br />

0 … 25.0 mg/l<br />

1 AQ4515370 iron Iron LR 0 ... 3.00 mg/l<br />

1 AQ4515660 hardness Hardness-P 0 … 0.500 mmol/l<br />

1 AQ465230 nitrate Testing powder<br />

1 AQ502810 nitrate Test<br />

0 … 3.00 mg/l<br />

1 AQ4512310 nitrite LR<br />

1 AQ4512310 nitrite LR 0 …2.00 mg/l<br />

1 AQ4513040 phosphate LR No.1<br />

1 AQ4513050 phosphate LR No.2<br />

0 … 7.00 ng/l<br />

1 AQ4515450 sulphate T 0 ... 500 mg/l<br />

2 AQ4511060 free chlorine DPD No.1<br />

2 AQ4511080 free chlorine DPD No.3<br />

0 … 3.00 mg/l<br />

2 AQ4515670 potassium Potassium 0 ... 30.0 mg/l<br />

2 AQ4513130 silicic acid Silicon No.1<br />

2 AQ4513140 silicic acid Silicon No.2 0 ... 6.00 mg/l<br />

2 AQ4513150 silicic acid Silicon PR<br />

2 AQ4513550 copper No.1<br />

2 AQ4513560 copper No.2<br />

0 ... 5.00 mg/l<br />

2 AQ4516080 manganese LR No.1<br />

2 AQ 4516090 manganese LR No.2<br />

0 … 4.00 mg/l<br />

2 AQ419033 nickel 2x 51 + 1x 52 0 … 10.00 mg/l<br />

2 AQ4518020 sulphite LR 0 … 20.00 mg/l<br />

2 AQ4512620 zinc LR 0 … 0.400 mg/l<br />

524 069 <strong>Immersion</strong> <strong>Photometer</strong> S<br />

Used with any CASSY interface and the appropriate reagents,<br />

pollutants and turbidity can be easily and accurately measured in<br />

water samples - the CASSY software comes pre-programmed to<br />

carry out investigations into 17 common pollutants.<br />

Besides the direct measurement of the parameters described<br />

above, investigations into reaction rates, kinetics, and more longterm<br />

evaluations such as turbidity in bioreactors are also<br />

possible.<br />

Technical Data<br />

Quantities: Transmission (%T), Absorbance (A),<br />

Concentration (c), Turbidity (FAU)<br />

Wavelengths: 455, 520, 558, 612, 696 nm (LEDs)<br />

Detector: Silicon-Photo elements<br />

Measurable pollutants: 17, see table,<br />

and turbidity (0 ... 2000 FAU)<br />

(own determinations possible)<br />

Output:<br />

15-pole plug connector for connection to<br />

the Sensor-CASSY<br />

Length of cable: 1 m<br />

Power supply: automatic via Sensor-CASSY<br />

Material: DURAN glass<br />

Volume of sample: 10 ml<br />

Dimensions: 26 mm diameter x 200 mm<br />

Weight:<br />

200 g<br />

Leybold Didactic GmbH • Leyboldstraße 1 • D-50354 Huerth • Tel.: +49 (0) 2233-604-0 • Fax: +49 (0)2233-604-222 • email: info@leybold-didactic.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!