Universal Temperature Converter<br />

<strong>MPU</strong> <strong>4.00</strong> G<br />

FEATURES<br />

Input, switchable:<br />

PT 100, 2-, 3-, 4-conductor switch<br />

Range: -50…800 °C<br />

Output, simultaneous:<br />

Current 0(4)...20 mA and<br />

Voltage 0(2)...10 V<br />

Fine-adjustment of<br />

offset and gain by trimmer<br />

Galvanic 3-way isolation<br />

of 4 kV<br />

FUNCTION<br />

The <strong>MPU</strong> <strong>4.00</strong> G is processing PT 100 signals and is<br />

used for the precise measurement of temperature<br />

with resistance thermometers in 2-, 3-, 4-wire<br />

technique. They are switchable by slide switch.<br />

It has a simultaneous output for current and<br />

voltage.<br />

The selection and respectively switchover of offset<br />

and temperature range -50...800 °C can be done by<br />

turn switch.<br />

The fine adjustment of zero point and terminal<br />

value is carried out by trimmer.<br />

An adjustment of the device is not necessary<br />

any longer.<br />

Auxiliary power: 230 V AC/ 24 V DC<br />

1 2<br />

12<br />

54,2<br />

Power supply<br />

Input<br />

Output<br />

2-/ 3-wire 4-wire<br />

{<br />

6<br />

5<br />

PT 100<br />

4<br />

3<br />

3-/ 4-wire<br />

Measuring start<br />

Measuring range<br />

Offset<br />

Gain<br />

11<br />

10<br />

8<br />

7<br />

9<br />

12<br />

+ U [V]<br />

GND<br />

+ I [mA]<br />

GND<br />

change-over<br />

1 2 3<br />

4 5 6<br />

Measuring<br />

start<br />

Measuring<br />

range<br />

78<br />

7 8 9<br />

106<br />

10 11 12<br />

22,5<br />

08-7


1 2 3<br />

4 5 6<br />

7 8 9<br />

10 11 12<br />

⇈<br />

6 5 4 3<br />

⇈<br />

6 5 4<br />

⇈<br />

6 5 4<br />

<strong>MPU</strong> <strong>4.00</strong> G<br />

~ -<br />

~ +<br />

Input<br />

Offset<br />

Gain<br />

<strong>Schuhmann</strong> GmbH & Co. KG<br />

Kleingartacher Str. 21<br />

D-74363 Güglingen<br />

Tel. + 49 71 35 50 56<br />

Fax + 49 71 35 53 55<br />

www.schuhmann-messtechnik.de<br />

+<br />

-<br />

+<br />

-<br />

Auxiliary power<br />

Output<br />

simultaneous<br />

U<br />

PT 100 Input<br />

change-over<br />

Dead-/ Live-Zero<br />

I<br />

4-wire<br />

3-wire<br />

2-wire<br />

check turn-switch!<br />

Input:<br />

Temperature sensor:<br />

PT 100, 2-/ 3-/ 4-wire switchable by slide switch<br />

connection: terminal 3, 4, 5, 6<br />

Input range selectable by turn switch:<br />

Position Start of measuring range Position Measuring range<br />

0 -50 °C 0 800 °C<br />

1 -40 °C 1 750 °C<br />

2 -30 °C 2 700 °C<br />

3 -20 °C 3 650 °C<br />

4 -10 °C 4 600 °C<br />

5 0 °C 5 550 °C<br />

6 10 °C 6 500 °C<br />

7 20 °C 7 450 °C<br />

8 30 °C 8 400 °C<br />

9 40 °C 9 350 °C<br />

A 50 °C A 300 °C<br />

B 60 °C B 250 °C<br />

C 70 °C C 200 °C<br />

D 80 °C D 150 °C<br />

E 90 °C E 100 °C<br />

F 100 °C F 50 °C<br />

Error in measuring during switching of each measuring range ≤ 0,5 %.<br />

E.g.: start = 5 range = E ⇒ Input: 0...100 °C<br />

Output:<br />

I: load-independent DC current: 0(4)...20 mA permissible load max. 580 Ω<br />

connection: terminal 10 -, 11 +<br />

U: load-independent DC voltage: 0(2)...10 V perm. load ≥ 5 kΩ simultaneous<br />

perm. load ≥ 1 kΩ exclusive<br />

offset adjustment: trimmer ± 15 %<br />

gain adjustment: trimmer ± 15 %<br />

connection: terminal 7 -, 8 +<br />

Output ranges switchable over bridge on terminal 9 + 12 (dead-/ live-zero):<br />

Terminal 9/ 12 Output U Output I<br />

open * 0...10 V 0...20 mA<br />

closed 2...10 V 4...20 mA<br />

* factory setting<br />

Environmental conditions:<br />

Storage temperature: -40...+70 °C<br />

Operating temperature: 0...55 °C<br />

Isolation voltage: 4 kV eff. 1 sec.<br />

input-output-auxiliary power<br />

Auxiliary power:<br />

230 V AC: 200...250 V AC<br />

approx. 9 mA<br />

24 V DC: 20...30 V DC<br />

approx. 60 mA<br />

Influence of<br />

auxiliary power: < 0,1 %<br />

Characteristics of transmission:<br />

Transmission error: < 0,2 %<br />

Linearity error: < 0,2 %<br />

Temperature error: < 100 ppm/K<br />

Load influence I: < 50 ppm<br />

of final value<br />

Load influence U: < 50 ppm<br />

at 1 kΩ load<br />

Setting time:<br />

< 500 msec.<br />

Directive:<br />

EMC Directive:<br />

2004/108/EC*<br />

Low Voltage Directive: 2006/95/EC<br />

*minimum deviations possible during<br />

HF-radiation influence<br />

Mounting details:<br />

Housing for top hat rail<br />

Type of protection:<br />

IP 20 housing<br />

IP 10 screw clamps<br />

Mounting rail fixed according to<br />

EN 50022-35 x 6,2 mm<br />

Width:<br />

22,5 mm<br />

Weight:<br />

190 g<br />

Material:<br />

Noryl V0 150/ ABS<br />

Flammability class: ISO R75A 147°C/ 90°C<br />

Approval:<br />

CE<br />

Connection:<br />

screw clamps<br />

≤ 2 x 2,5 mm2<br />

For safety reasons we recommend to<br />

mount the housing for top hat rail with a<br />

distance of approx. 5 mm to each other.<br />

Please check switch position before initial<br />

operation !<br />

Ordering information: Type: <strong>MPU</strong> <strong>4.00</strong> G 230 V AC<br />

<strong>MPU</strong> <strong>4.00</strong> GDC 24 V DC<br />

08.02.2013<br />