Universal Temperature Converter<br />
<strong>MPU</strong> <strong>4.00</strong> G<br />
FEATURES<br />
Input, switchable:<br />
PT 100, 2-, 3-, 4-conductor switch<br />
Range: -50…800 °C<br />
Output, simultaneous:<br />
Current 0(4)...20 mA and<br />
Voltage 0(2)...10 V<br />
Fine-adjustment of<br />
offset and gain by trimmer<br />
Galvanic 3-way isolation<br />
of 4 kV<br />
FUNCTION<br />
The <strong>MPU</strong> <strong>4.00</strong> G is processing PT 100 signals and is<br />
used for the precise measurement of temperature<br />
with resistance thermometers in 2-, 3-, 4-wire<br />
technique. They are switchable by slide switch.<br />
It has a simultaneous output for current and<br />
voltage.<br />
The selection and respectively switchover of offset<br />
and temperature range -50...800 °C can be done by<br />
turn switch.<br />
The fine adjustment of zero point and terminal<br />
value is carried out by trimmer.<br />
An adjustment of the device is not necessary<br />
any longer.<br />
Auxiliary power: 230 V AC/ 24 V DC<br />
1 2<br />
12<br />
54,2<br />
Power supply<br />
Input<br />
Output<br />
2-/ 3-wire 4-wire<br />
{<br />
6<br />
5<br />
PT 100<br />
4<br />
3<br />
3-/ 4-wire<br />
Measuring start<br />
Measuring range<br />
Offset<br />
Gain<br />
11<br />
10<br />
8<br />
7<br />
9<br />
12<br />
+ U [V]<br />
GND<br />
+ I [mA]<br />
GND<br />
change-over<br />
1 2 3<br />
4 5 6<br />
Measuring<br />
start<br />
Measuring<br />
range<br />
78<br />
7 8 9<br />
106<br />
10 11 12<br />
22,5<br />
08-7
1 2 3<br />
4 5 6<br />
7 8 9<br />
10 11 12<br />
⇈<br />
6 5 4 3<br />
⇈<br />
6 5 4<br />
⇈<br />
6 5 4<br />
<strong>MPU</strong> <strong>4.00</strong> G<br />
~ -<br />
~ +<br />
Input<br />
Offset<br />
Gain<br />
<strong>Schuhmann</strong> GmbH & Co. KG<br />
Kleingartacher Str. 21<br />
D-74363 Güglingen<br />
Tel. + 49 71 35 50 56<br />
Fax + 49 71 35 53 55<br />
www.schuhmann-messtechnik.de<br />
+<br />
-<br />
+<br />
-<br />
Auxiliary power<br />
Output<br />
simultaneous<br />
U<br />
PT 100 Input<br />
change-over<br />
Dead-/ Live-Zero<br />
I<br />
4-wire<br />
3-wire<br />
2-wire<br />
check turn-switch!<br />
Input:<br />
Temperature sensor:<br />
PT 100, 2-/ 3-/ 4-wire switchable by slide switch<br />
connection: terminal 3, 4, 5, 6<br />
Input range selectable by turn switch:<br />
Position Start of measuring range Position Measuring range<br />
0 -50 °C 0 800 °C<br />
1 -40 °C 1 750 °C<br />
2 -30 °C 2 700 °C<br />
3 -20 °C 3 650 °C<br />
4 -10 °C 4 600 °C<br />
5 0 °C 5 550 °C<br />
6 10 °C 6 500 °C<br />
7 20 °C 7 450 °C<br />
8 30 °C 8 400 °C<br />
9 40 °C 9 350 °C<br />
A 50 °C A 300 °C<br />
B 60 °C B 250 °C<br />
C 70 °C C 200 °C<br />
D 80 °C D 150 °C<br />
E 90 °C E 100 °C<br />
F 100 °C F 50 °C<br />
Error in measuring during switching of each measuring range ≤ 0,5 %.<br />
E.g.: start = 5 range = E ⇒ Input: 0...100 °C<br />
Output:<br />
I: load-independent DC current: 0(4)...20 mA permissible load max. 580 Ω<br />
connection: terminal 10 -, 11 +<br />
U: load-independent DC voltage: 0(2)...10 V perm. load ≥ 5 kΩ simultaneous<br />
perm. load ≥ 1 kΩ exclusive<br />
offset adjustment: trimmer ± 15 %<br />
gain adjustment: trimmer ± 15 %<br />
connection: terminal 7 -, 8 +<br />
Output ranges switchable over bridge on terminal 9 + 12 (dead-/ live-zero):<br />
Terminal 9/ 12 Output U Output I<br />
open * 0...10 V 0...20 mA<br />
closed 2...10 V 4...20 mA<br />
* factory setting<br />
Environmental conditions:<br />
Storage temperature: -40...+70 °C<br />
Operating temperature: 0...55 °C<br />
Isolation voltage: 4 kV eff. 1 sec.<br />
input-output-auxiliary power<br />
Auxiliary power:<br />
230 V AC: 200...250 V AC<br />
approx. 9 mA<br />
24 V DC: 20...30 V DC<br />
approx. 60 mA<br />
Influence of<br />
auxiliary power: < 0,1 %<br />
Characteristics of transmission:<br />
Transmission error: < 0,2 %<br />
Linearity error: < 0,2 %<br />
Temperature error: < 100 ppm/K<br />
Load influence I: < 50 ppm<br />
of final value<br />
Load influence U: < 50 ppm<br />
at 1 kΩ load<br />
Setting time:<br />
< 500 msec.<br />
Directive:<br />
EMC Directive:<br />
2004/108/EC*<br />
Low Voltage Directive: 2006/95/EC<br />
*minimum deviations possible during<br />
HF-radiation influence<br />
Mounting details:<br />
Housing for top hat rail<br />
Type of protection:<br />
IP 20 housing<br />
IP 10 screw clamps<br />
Mounting rail fixed according to<br />
EN 50022-35 x 6,2 mm<br />
Width:<br />
22,5 mm<br />
Weight:<br />
190 g<br />
Material:<br />
Noryl V0 150/ ABS<br />
Flammability class: ISO R75A 147°C/ 90°C<br />
Approval:<br />
CE<br />
Connection:<br />
screw clamps<br />
≤ 2 x 2,5 mm2<br />
For safety reasons we recommend to<br />
mount the housing for top hat rail with a<br />
distance of approx. 5 mm to each other.<br />
Please check switch position before initial<br />
operation !<br />
Ordering information: Type: <strong>MPU</strong> <strong>4.00</strong> G 230 V AC<br />
<strong>MPU</strong> <strong>4.00</strong> GDC 24 V DC<br />
08.02.2013<br />
08-8