Flasher 3250 Owner's Manual lite for fax - Vanner
Flasher 3250 Owner's Manual lite for fax - Vanner
Flasher 3250 Owner's Manual lite for fax - Vanner
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>3250</strong>GCP FLASHER<br />
<strong>Owner's</strong> <strong>Manual</strong><br />
GENERAL<br />
The heavy duty <strong>3250</strong>GCP electronic flasher has been designed to operate in the most severe<br />
environments. This unit also has output short circuit protection <strong>for</strong> reverse input voltage<br />
protection.<br />
WARNING LIGHTS<br />
The <strong>3250</strong>GCP flasher can be used with most incandescent, halogen, and LED warning lights.<br />
CHARACTERISTICS & TIPS<br />
1) For extended service reliability, it is important that the flasher is not overloaded. In some<br />
cases, the unit's short circuit protection may consider the overload a short circuit, and shut<br />
the unit down.<br />
2) The A output of the flasher receives its operating voltage from the B output. If the B output<br />
does not flash, then as a result the A output will not flash.<br />
SPECIFICATIONS<br />
Maximum output current:<br />
-with 50w lamps<br />
-with 35w lamps<br />
Input Voltage:<br />
Flashes per min. over full voltage range: 60 ± 8%<br />
50 Amps per terminal<br />
Duty cycle: 50/50 ± 10%<br />
Ambient temperature:<br />
Fuse or Circuit Breaker:<br />
9 Typical per terminal<br />
12 Typical per terminal<br />
10-16 Vdc, 13.6 Vdc nominal<br />
-40ºF to +150ºF (-40ºC to +65ºC)<br />
70 Amp max.<br />
TROUBLESHOOTING<br />
PROBLEM<br />
All outputs do not flash:<br />
ITEMS TO CHECK<br />
1) Is the battery voltage less than 10Vdc?<br />
2) Are the wire and light connections proper?<br />
3) Do you have more than the rated number of<br />
lights on the outputs?<br />
4) Is the remote ground switch wired correctly?<br />
One output does not flash:<br />
1) Is the battery voltage less than 10 Vdc?<br />
2) Is the affected output shorted or overloaded?<br />
*If after reviewing this chart you still can't locate the problem, contact <strong>Vanner</strong> <strong>for</strong> technical assistance--800-AC POWER<br />
<strong>Vanner</strong>, Inc.<br />
OM-D99905-A 08/00
¡ ¡<br />
¢¢£ £ ¢¢<br />
¤ ¤<br />
FLASHERS<br />
<strong>3250</strong>GCP <strong>Owner's</strong> <strong>Manual</strong><br />
OPTIONAL LAMPS<br />
B<br />
LAMP REPLACEMENT DIAGRAM<br />
A<br />
B<br />
A<br />
B<br />
A<br />
FRONT OF<br />
VEHICLE<br />
B<br />
A<br />
B<br />
A<br />
A<br />
B<br />
CONNECTION DIAGRAM<br />
GROUND<br />
CONTROL<br />
SWITCH<br />
LAMP OUTPUTS<br />
+12VDC<br />
GROUND CONTROL +12V<br />
MODEL: <strong>3250</strong> GCP<br />
HILLIARD, OHIO USA<br />
ALTERNATING FLASHER<br />
B A<br />
B LAMPS<br />
A LAMPS<br />
SEE SPECIFICATIONS<br />
FOR FUSE RATING<br />
SLOT, .250 x .312 (4 PLACES)<br />
#10-32 STUD<br />
TORQUE RANGE<br />
18-25 IN-LBS<br />
MOUNTING DIMENSIONS<br />
1/4-20 STUD<br />
(4 PLACES)<br />
TORQUE RANGE<br />
28-35 IN-LBS<br />
2.63<br />
4.37<br />
4.75<br />
3.00<br />
3.50<br />
Corporate Office: 4282 Reynolds Drive • Hilliard, Ohio 43026 • Tel (614) 771-2718 • Fax (614) 771-4904 • www.vanner.com<br />
OM-D99905-A 08/00 ©Copyright 1998, <strong>Vanner</strong>, Inc. Specifications subject to change without notice.<br />