<strong>3250</strong>GCP FLASHER<br />

<strong>Owner's</strong> <strong>Manual</strong><br />

GENERAL<br />

The heavy duty <strong>3250</strong>GCP electronic flasher has been designed to operate in the most severe<br />

environments. This unit also has output short circuit protection <strong>for</strong> reverse input voltage<br />

protection.<br />

WARNING LIGHTS<br />

The <strong>3250</strong>GCP flasher can be used with most incandescent, halogen, and LED warning lights.<br />

CHARACTERISTICS & TIPS<br />

1) For extended service reliability, it is important that the flasher is not overloaded. In some<br />

cases, the unit's short circuit protection may consider the overload a short circuit, and shut<br />

the unit down.<br />

2) The A output of the flasher receives its operating voltage from the B output. If the B output<br />

does not flash, then as a result the A output will not flash.<br />

SPECIFICATIONS<br />

Maximum output current:<br />

-with 50w lamps<br />

-with 35w lamps<br />

Input Voltage:<br />

Flashes per min. over full voltage range: 60 ± 8%<br />

50 Amps per terminal<br />

Duty cycle: 50/50 ± 10%<br />

Ambient temperature:<br />

Fuse or Circuit Breaker:<br />

9 Typical per terminal<br />

12 Typical per terminal<br />

10-16 Vdc, 13.6 Vdc nominal<br />

-40ºF to +150ºF (-40ºC to +65ºC)<br />

70 Amp max.<br />

TROUBLESHOOTING<br />

PROBLEM<br />

All outputs do not flash:<br />

ITEMS TO CHECK<br />

1) Is the battery voltage less than 10Vdc?<br />

2) Are the wire and light connections proper?<br />

3) Do you have more than the rated number of<br />

lights on the outputs?<br />

4) Is the remote ground switch wired correctly?<br />

One output does not flash:<br />

1) Is the battery voltage less than 10 Vdc?<br />

2) Is the affected output shorted or overloaded?<br />

*If after reviewing this chart you still can't locate the problem, contact <strong>Vanner</strong> <strong>for</strong> technical assistance--800-AC POWER<br />

<strong>Vanner</strong>, Inc.<br />

OM-D99905-A 08/00


¡ ¡<br />

¢¢£ £ ¢¢<br />

¤ ¤<br />

FLASHERS<br />

<strong>3250</strong>GCP <strong>Owner's</strong> <strong>Manual</strong><br />

OPTIONAL LAMPS<br />

B<br />

LAMP REPLACEMENT DIAGRAM<br />

A<br />

B<br />

A<br />

B<br />

A<br />

FRONT OF<br />

VEHICLE<br />

B<br />

A<br />

B<br />

A<br />

A<br />

B<br />

CONNECTION DIAGRAM<br />

GROUND<br />

CONTROL<br />

SWITCH<br />

LAMP OUTPUTS<br />

+12VDC<br />

GROUND CONTROL +12V<br />

MODEL: <strong>3250</strong> GCP<br />

HILLIARD, OHIO USA<br />

ALTERNATING FLASHER<br />

B A<br />

B LAMPS<br />

A LAMPS<br />

SEE SPECIFICATIONS<br />

FOR FUSE RATING<br />

SLOT, .250 x .312 (4 PLACES)<br />

#10-32 STUD<br />

TORQUE RANGE<br />

18-25 IN-LBS<br />

MOUNTING DIMENSIONS<br />

1/4-20 STUD<br />

(4 PLACES)<br />

TORQUE RANGE<br />

28-35 IN-LBS<br />

2.63<br />

4.37<br />

4.75<br />

3.00<br />

3.50<br />

Corporate Office: 4282 Reynolds Drive • Hilliard, Ohio 43026 • Tel (614) 771-2718 • Fax (614) 771-4904 • www.vanner.com<br />

OM-D99905-A 08/00 ©Copyright 1998, <strong>Vanner</strong>, Inc. Specifications subject to change without notice.<br />