Procedure:<br />
a) Dry approximately 5 grams <strong>of</strong> the stearate treated limestone product and<br />
approximately 5 grams <strong>of</strong> the limestone product prior to treatment with stearate, at<br />
105 deg. C. for 2 hours. Cool in a dessicator.<br />
b) Transfer the crucibles containing the limestone samples, treated and untreated, to a<br />
separate, previously ignited, weighed porcelain crucible and cover. The crucible and<br />
cover should have been cooled in a dessicator after ignition and weighed to 0.1 mg.<br />
c) Weigh the crucibles containing the limestone samples, and the covers to 0.1 mg.<br />
d) Remove the cover and place it and the crucibles containing the limestone samples in<br />
the muffle furnace. Heat the samples to 400 deg. C. for 1.5 hours.<br />
e) Replace the covers, cool in dessicator and weigh to 0.1mg. To assure that constant<br />
weight has been achieved, heat the samples again for 30 minutes at 400 deg. C., cool<br />
and weigh.<br />
f) Determine the percent weight loss in each crucible.<br />
L W = [SC B _ SC A X 100]/ [SC B _ C T ]<br />
Where:<br />
L W = % Loss <strong>of</strong> Weight<br />
C T = Tare Weight <strong>of</strong> Crucible and Cover<br />
SC B = Weight <strong>of</strong> Sample, Crucible and Cover before heating<br />
SC A = Weight <strong>of</strong> Sample, Crucible and Cover after heating<br />
Reporting: The amount <strong>of</strong> stearate treatment in percent should be reported. The<br />
following calculation can be used to determine the amount <strong>of</strong> stearate treatment in<br />
percent.<br />
P T = L W T _ L W U<br />
Where:<br />
P T = Amount <strong>of</strong> Treatment in Percent<br />
L W T = % Loss <strong>of</strong> Weight <strong>of</strong> the Treated Sample<br />
L W U = % Loss <strong>of</strong> Weight <strong>of</strong>f the Untreated Sample<br />
Precision: Duplicate determinations should agree within plus or minus 0.1%.<br />