ABB Control Inc. A-Line contactors A145 â A300 - Piti Group
ABB Control Inc. A-Line contactors A145 â A300 - Piti Group
ABB Control Inc. A-Line contactors A145 â A300 - Piti Group
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
A-<strong>Line</strong> <strong>contactors</strong><br />
<strong>A145</strong> – <strong>A300</strong><br />
AC 1035<br />
C U S T O M E R<br />
F I R S T<br />
Q U A L<br />
I T Y..<br />
.<br />
A L WAY S<br />
Registered by UL to<br />
ISO 9002<br />
!<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.
AC 1035 — 10/1999<br />
A-<strong>Line</strong> <strong>contactors</strong><br />
<strong>A145</strong> – <strong>A300</strong><br />
General information<br />
• Table of contents ............................................... II<br />
• Alphanumeric price guide.......................... III – IV<br />
Pricing and selection, <strong>A145</strong>-<strong>A300</strong> ............................. 4<br />
Accessories .......................................................... 5 - 7<br />
Technical data ...................................................... 8 - 9<br />
Approximate dimensions .................................. 10 - 13<br />
Dimensions Technical data<br />
Accessories<br />
<strong>A145</strong> - <strong>A300</strong> General information<br />
Terms & Standard compliance & approvals ..... 15 - 16<br />
Terms<br />
This catalog is published for information purposes only and is not all inclusive. For additional information on products or technical<br />
information, consult <strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>. The installation and use of <strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>. products should be in accordance with the<br />
provisions of the U.S. National Electrical Code and/or other local codes or industry standards that are pertinent to the particular<br />
Table of contents: pg 2 Alphanumeric: pg 3 end use. Selection: Installation pg or 4 use not in accordance Accessories: with pgs these 5 – codes 7 and Tech standards data: could pgs 8 be – hazardous 9 to personnel Dimensions: and/or pgs equipment. 10 – 13<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.<br />
1
Table of contents<br />
Subject Product category Page no. Subject Product category Page no.<br />
General information<br />
A<br />
AC operated contactor coil .................................................................................. 7<br />
Across the line <strong>contactors</strong> .................................................................................... 4<br />
Adapter plates ...................................................................................................... 7<br />
Approximate dimensions ............................................................................... 10-13<br />
Auxiliary contact blocks ....................................................................................... 5<br />
C<br />
Cable connectors ................................................................................................. 6<br />
Connection bars ................................................................................................... 6<br />
Connection strips ............................................................................................. 6, 7<br />
Connectors, cable ................................................................................................ 6<br />
Contact blocks, auxiliary ...................................................................................... 5<br />
Contact sets, main ............................................................................................... 7<br />
Contactor coil, AC operated ................................................................................. 7<br />
Contactors, across the line .................................................................................. 4<br />
D<br />
De-ionizing plates ................................................................................................. 7<br />
M<br />
Main contact sets ................................................................................................. 7<br />
Mechanical interlocks ........................................................................................... 5<br />
Mounting kits, T450 overload relay ..................................................................... 5<br />
Mounting screws, self tapping ............................................................................. 7<br />
O<br />
Overload relay mounting kits, T450 ..................................................................... 5<br />
Overload relays .................................................................................................... 5<br />
R<br />
Relays, overload .................................................................................................. 5<br />
S<br />
Self tapping mounting screws .............................................................................. 7<br />
Standard compliance & approvals ..................................................................... 16<br />
Surge suppressors ............................................................................................... 5<br />
T<br />
T450 overload relay mounting kits ...................................................................... 5<br />
TA200 terminal shroud ......................................................................................... 5<br />
Technical data ................................................................................................... 8-9<br />
Terminal enlargements ........................................................................................ 7<br />
Terminal extensions ............................................................................................. 7<br />
Terminal shroud fro TA200 .................................................................................. 5<br />
Terms & conditions ............................................................................................ 15<br />
Table of contents: pg 2 Alphanumeric: pg 3 Selection: pg 4 Accessories: pgs 5 – 7 Tech data: pgs 8 – 9 Dimensions: pgs 10 – 13<br />
AC 1035 — 10/1999<br />
2 <strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.
AC 1035 — 10/1999<br />
Availability code legend<br />
A – Stock to 2 weeks<br />
B – 1 to 2 weeks<br />
C – 2 to 4 weeks<br />
D – 4 to 6 weeks<br />
E – Call for delivery<br />
NA – Not available, consult factory<br />
Alphanumeric price guide<br />
1SFN110401R1000 to ZW300<br />
Catalog price information<br />
List prices shown in this publication supersede all previously<br />
published documentation and are subject to change without<br />
notice.<br />
Alphanumeric reference<br />
This above alphanumeric reference is an extract of AC 5030,<br />
Alphanumeric Reference, which contains all products sold by<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.<br />
AC 5030 is available on disk for Windows and Macintosh as a<br />
MicroSoft Excel 5.0 document. An ASCII text version of the<br />
data is also included for use in other spreadsheet and database<br />
applications.<br />
Catalog List Disc. Avail. Pg. Catalog List Disc. Avail. Pg. Catalog List Disc. Avail. Pg. Catalog List Disc. Avail. Pg.<br />
number price sched. code no. number price sched. code no. number price sched. code no. number price sched. code no.<br />
1SFN110401R1000 $10.00 ABA A 7<br />
<strong>A145</strong>-30-00-84 $785.00 AEA A 4<br />
<strong>A145</strong>-30-11-84 $825.00 AEA A 4<br />
<strong>A145</strong>-30-22-84 $865.00 AEA A 4<br />
A185-30-00-84 $1,250.00 AEA A 4<br />
A185-30-11-84 $1,290.00 AEA A 4<br />
A185-30-22-84 $1,330.00 AEA A 4<br />
A210-30-00-84 $1,595.00 AEA A 4<br />
A210-30-11-84 $1,635.00 AEA A 4<br />
A210-30-22-84 $1,695.00 AEA A 4<br />
A260-30-00-84 $1,775.00 AEA A 4<br />
A260-30-11-84 $1,815.00 AEA A 4<br />
A260-30-22-84 $1,855.00 AEA A 4<br />
<strong>A300</strong>-30-00-84 $1,835.00 AEA A 4<br />
<strong>A300</strong>-30-11-84 $1,875.00 AEA A 4<br />
LT185-AC $10.00 ABA A 6<br />
LT185-AL $10.00 ABA A 6<br />
LT200A185 $90.00 ABA A 5<br />
LT300-AC $10.00 ABA A 6<br />
LT300-AL $10.00 ABA A 6<br />
LW185 $120.00 ABA A 7<br />
LW300 $130.00 ABA A 7<br />
LX185 $90.00 ABA A 7<br />
LX300 $140.00 ABA A 7<br />
LYA185 $90.00 ABA A 7<br />
LY<strong>A300</strong> $140.00 ABA A 7<br />
PR145-1 $20.00 ABA A 7<br />
PR210-1 $20.00 ABA A 7<br />
PR300-1 $20.00 ABA A 7<br />
RC5-2/133 $30.00 ABA A 5<br />
VM300V $180.00 ABA A 5<br />
ZA185 $150.00 ABA A 7<br />
Z<strong>A300</strong> $180.00 ABA A 7<br />
ZL145 $300.00 ABA A 7<br />
ZL185 $420.00 ABA A 7<br />
ZL210 $525.00 ABA A 7<br />
ZL260 $855.00 ABA A 7<br />
ZL300 $1,020.00 ABA A 7<br />
ZW185 $130.00 ABA A 7<br />
ZW300 $180.00 ABA A 7<br />
General information<br />
<strong>A300</strong>-30-22-84 $1,915.00 AEA A 4<br />
ATK185 $45.00 ABA A 6<br />
ATK300 $68.00 ABA A 6<br />
ATK300/2 $110.00 ABA A 6<br />
BEA185/S3/S4 $60.00 ABA A 6<br />
BE<strong>A300</strong>/S5 $75.00 ABA A 6<br />
BED145A $250.00 ABA A 6<br />
BED185 $290.00 ABA A 6<br />
BED210 $375.00 ABA A 6<br />
BED300 $500.00 ABA A 6<br />
BEMA185-30 $260.00 ABA A 6<br />
BEM<strong>A300</strong>-30 $470.00 ABA A 6<br />
BESA185-30 $130.00 ABA A 6<br />
BES<strong>A300</strong>-30 $200.00 ABA A 6<br />
CAL5-11 $30.00 ABA A 5<br />
CAL5-11B $30.00 ABA A 5<br />
DT450/A185 $225.00 ABA A 5<br />
DT450/<strong>A300</strong> $225.00 ABA A 5<br />
LP185 $20.00 ABA A 6<br />
LP300 $30.00 ABA A 6<br />
RC5-2/250 $30.00 ABA A 5<br />
RC5-2/440 $30.00 ABA A 5<br />
RC5-2/50 $30.00 ABA A 5<br />
TA200DU110 $165.00 TC A 5<br />
TA200DU135 $225.00 TC A 5<br />
TA200DU150 $225.00 TC A 5<br />
TA200DU175 $225.00 TC A 5<br />
TA200DU200 $225.00 TC A 5<br />
TA200DU90 $165.00 TC A 5<br />
TA450DU185 $488.00 TCT A 5<br />
TA450DU235 $488.00 TCT A 5<br />
TA450DU310 $488.00 TCT A 5<br />
TA450SU105 $525.00 TCT A 5<br />
TA450SU140 $525.00 TCT A 5<br />
TA450SU185 $713.00 TCT A 5<br />
TA450SU235 $713.00 TCT A 5<br />
TA450SU310 $713.00 TCT A 5<br />
TA450SU60 $525.00 TCT A 5<br />
TA450SU80 $525.00 TCT A 5<br />
VM300H $110.00 ABA A 5<br />
Table of contents: pg 2 Alphanumeric: pg 3 Selection: pg 4 Accessories: pgs 5 – 7 Tech data: pgs 8 – 9 Dimensions: pgs 10 – 13<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.<br />
3
Across the line <strong>contactors</strong><br />
<strong>A145</strong> – <strong>A300</strong><br />
<strong>A145</strong>-30-11<br />
<strong>A300</strong>-30-11<br />
<strong>A145</strong> - <strong>A300</strong><br />
Standard<br />
UL<br />
Maximum motor horsepower ratings<br />
auxiliary contacts<br />
AC operated<br />
200 – 208VAC 550 – 600VAC N.C.<br />
Catalog<br />
List<br />
current number price<br />
general purpose<br />
220 – 240VAC 440 – 480VAC N.O.<br />
UL rated<br />
0 0 <strong>A145</strong>-30-00-84 $ 785<br />
230 40 50 100 125 1 1 <strong>A145</strong>-30-11-84 825<br />
2 2 <strong>A145</strong>-30-22-84 865<br />
0 0 A185-30-00-84 1250<br />
250 50 60 125 150 1 1 A185-30-11-84 1290<br />
2 2 A185-30-22-84 1330<br />
0 0 A210-30-00-84 1595<br />
300 60 75 150 200 1 1 A210-30-11-84 1635<br />
2 2 A210-30-22-84 1695<br />
0 0 A260-30-00-84 1775<br />
350 75 100 200 250 1 1 A260-30-11-84 1815<br />
2 2 A260-30-22-84 1855<br />
0 0 <strong>A300</strong>-30-00-84 1835<br />
400 100 100 250 300 1 1 <strong>A300</strong>-30-11-84 1875<br />
2 2 <strong>A300</strong>-30-22-84 1915<br />
Coil voltage selection<br />
All catalog numbers include a 120VAC coil. To select other coil voltages,<br />
substitute the code from the "Coil voltage selection" chart for the two digits after<br />
the last dash in the catalog number.<br />
Ex.: A 240V coil is required for an <strong>A145</strong>-30-11 contactor: <strong>A145</strong>-30-11-80<br />
Coil voltage selection chart<br />
Hz Cntr<br />
Volts<br />
type 12 24 48 110 120 125 208 220 240 277 380 415 440 480 500 600<br />
60 A 81 83 84 84 34 75 80 42 86 86 51 53 55<br />
50 A 81 83 84 80 85 86 55<br />
Table of contents: pg 2 Alphanumeric: pg 3 Selection: pg 4 Accessories: pgs 5 – 7 Tech data: pgs 8 – 9 Dimensions: pgs 10 – 13<br />
AC 1035 — 10/1999<br />
4 Discount schedule AEA<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.
AC 1035 — 10/1999<br />
Accessories<br />
Overload relays<br />
For Setting range Catalog List<br />
contactor A number price<br />
TA450DU/SU<br />
Normal starting time class 10 65 – 90 TA200DU90<br />
80 – 110 TA200DU110<br />
<strong>A145</strong> – A185 100 – 135 TA200DU135<br />
110 – 150 TA200DU150<br />
130 – 175 TA200DU175<br />
150 – 200 TA200DU200<br />
$ 165<br />
Normal starting time class 10 130 – 185 TA450DU185<br />
A210 – <strong>A300</strong> 165 – 235 TA450DU235 488<br />
220 – 310 TA450DU310<br />
Long starting time class 30 40 – 60 TA450SU60<br />
55 – 80 TA450SU80 525<br />
70 – 105 TA450SU105<br />
<strong>A145</strong> – <strong>A300</strong> 95 – 140 TA450SU140<br />
225<br />
130 – 185 TA450SU185<br />
165 – 235 TA450SU235 713<br />
220 – 310 TA450SU310<br />
Mounting kits for T450 overload relays<br />
For contactor<br />
<strong>A145</strong> – A185<br />
A260 – <strong>A300</strong><br />
Catalog<br />
number<br />
DT450/A185<br />
DT450/<strong>A300</strong><br />
List<br />
price<br />
$ 225<br />
CAL5-11<br />
Terminal shroud for TA200<br />
Auxiliary contact block<br />
Catalog<br />
List<br />
For contactor<br />
number<br />
price<br />
<strong>A145</strong> – A185 LT200A185 $ 90<br />
Catalog<br />
List<br />
Description<br />
number<br />
price<br />
First block: left and right, 1 N.O. & 1 N.C., for <strong>contactors</strong> <strong>A145</strong> – <strong>A300</strong><br />
CAL5-11<br />
$ 30<br />
Second block: second left and right, 1 N.O. & 1 N.C., for <strong>contactors</strong> <strong>A145</strong> – <strong>A300</strong> CAL5-11B<br />
Accessories<br />
VM300<br />
Mechanical interlock for horizontal mounted <strong>contactors</strong> — for left and right contactor<br />
Catalog<br />
List<br />
For contactor<br />
number<br />
price<br />
A110 – <strong>A300</strong> VM300H $ 110<br />
Mechanical interlock for vertical mounted <strong>contactors</strong><br />
Catalog<br />
List<br />
For contactor<br />
number<br />
price<br />
A110 – <strong>A300</strong> VM300V $ 180<br />
Surge supressors, type RC — for <strong>contactors</strong> <strong>A145</strong> – <strong>A300</strong><br />
Voltage AC<br />
Catalog<br />
number<br />
24 – 50 RC5-2/50<br />
50 – 133 RC5-2/133<br />
110 – 250 RC5-2/250<br />
250 – 440 RC5-2/440<br />
List<br />
price<br />
$ 30<br />
RC5-2___<br />
Table of contents: pg 2 Alphanumeric: pg 3 Selection: pg 4 Accessories: pgs 5 – 7 Tech data: pgs 8 – 9 Dimensions: pgs 10 – 13<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.<br />
Discount schedule ABA – Accessories<br />
Discount schedule TC – TA200 OLR<br />
Discount schedule TCT – TA450 OLR<br />
5
Accessories<br />
Cable connectors for Al and Cu cables — set of three<br />
Wire For Catalog List<br />
range contactor number price<br />
6 – 250MCM <strong>A145</strong> – A185 ATK185 $ 45<br />
4 – 400MCM A210 – <strong>A300</strong> ATK300 68<br />
(2) 4 – 500MCM A210 – <strong>A300</strong> ATK300/2 110<br />
LT185-AC<br />
Terminal shrouds — two pieces<br />
For contactor<br />
<strong>A145</strong> – A185 for cable connectors<br />
<strong>A145</strong> – A185 for compression lugs<br />
A210 – <strong>A300</strong> for cable connectors<br />
A210 – <strong>A300</strong> for compression lugs<br />
Catalog<br />
number<br />
LT185-AC<br />
LT185-AL<br />
LT300-AC<br />
LT300-AL<br />
List<br />
price<br />
$ 10<br />
LT185-AL<br />
Connection bars for reversing <strong>contactors</strong> — six bars<br />
For contactor<br />
Catalog<br />
number<br />
List<br />
price<br />
<strong>A145</strong> – A185 BEMA185-30 $ 260<br />
A210 – <strong>A300</strong> BEM<strong>A300</strong>-30 470<br />
BEM185-30<br />
Connection bars for phase to phase — three bars<br />
For contactor<br />
Catalog<br />
number<br />
List<br />
price<br />
<strong>A145</strong> – A185 BESA185-30 $ 130<br />
A210 – <strong>A300</strong> BES<strong>A300</strong>-30 200<br />
Accessories<br />
BEA185/S3/S4<br />
Connection bars between contactor and MCCB — three bars<br />
Wire range<br />
For contactor<br />
Catalog<br />
List<br />
number<br />
price<br />
S3 – S4 <strong>A145</strong> – A185 BEA185/S3/S4 $ 60<br />
S5 A210 – <strong>A300</strong> BE<strong>A300</strong>/S5 75<br />
Connection bars for star-delta starters — seven bars<br />
Contactors line and delta<br />
Star<br />
Catalog<br />
List<br />
number<br />
price<br />
<strong>A145</strong> A110 BED145 $ 250<br />
A185 <strong>A145</strong> BED185 290<br />
A210 A185 BED210 375<br />
A260 A210 BED300 500<br />
<strong>A300</strong> A210 BED300 500<br />
LP185<br />
Connection strips 2 pole — two pieces<br />
For contactor<br />
Catalog<br />
number<br />
List<br />
price<br />
<strong>A145</strong> – A185 LP185 $ 20<br />
A210 – <strong>A300</strong> LP300 30<br />
Table of contents: pg 2 Alphanumeric: pg 3 Selection: pg 4 Accessories: pgs 5 – 7 Tech data: pgs 8 – 9 Dimensions: pgs 10 – 13<br />
AC 1035 — 10/1999<br />
6 Discount schedule ABA<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.
AC 1035 — 10/1999<br />
Accessories<br />
Connection strips — 3 pole<br />
For contactor<br />
Catalog<br />
List<br />
number<br />
price<br />
<strong>A145</strong> – A185 LYA185 $ 90<br />
A260 – <strong>A300</strong> LY<strong>A300</strong>A 140<br />
LY185<br />
Terminal extensions — 3 pole device<br />
For contactor<br />
Catalog<br />
List<br />
number<br />
price<br />
<strong>A145</strong> – A185 LX185 $ 90<br />
A260 – <strong>A300</strong> LX300 140<br />
Terminal enlargements — 3 pole device, same width as EH terminals<br />
For contactor<br />
Catalog<br />
List<br />
number<br />
price<br />
<strong>A145</strong> – A185 LW185 $ 120<br />
A210 – <strong>A300</strong> LW300 130<br />
LX185<br />
Main contact sets<br />
For contactor<br />
Catalog<br />
List<br />
number<br />
price<br />
<strong>A145</strong> ZL145 $ 300<br />
A185 ZL185 420<br />
A210 ZL210 525<br />
A260 ZL260 855<br />
<strong>A300</strong> ZL300 1020<br />
ZL145<br />
ZW185<br />
De-ionizing plates — six pieces<br />
AC operated contactor coil<br />
Note: for coil code see page 4<br />
Adapter plates — to replace EH <strong>contactors</strong><br />
For contactor<br />
Catalog<br />
List<br />
number<br />
price<br />
<strong>A145</strong> – A185 ZW185 $ 130<br />
A210 – <strong>A300</strong> ZW300 180<br />
For contactor<br />
Catalog<br />
List<br />
number<br />
price<br />
<strong>A145</strong> – A185 ZA185 $ 150<br />
A210 – <strong>A300</strong> Z<strong>A300</strong> 180<br />
For contactor<br />
Catalog<br />
List<br />
number<br />
price<br />
Replace EH100 or EH145 with <strong>A145</strong><br />
PR145-1<br />
Replace EH150 – EH210 with A185 – A210 PR210-1 $ 20<br />
Replace EH250 – EH300 with A260 – <strong>A300</strong><br />
PR300-1<br />
Accessories<br />
ZA185<br />
Self tapping mounting screw (M5 x 70, set of 100)1<br />
Catalog<br />
List<br />
For contactor<br />
number<br />
price<br />
<strong>A145</strong> – <strong>A300</strong> 1SFN110401R1000 $ 10<br />
PR145-1<br />
1 Four mounting screws (not self-tapping) M5 x 70) come with the contactor<br />
Table of contents: pg 2 Alphanumeric: pg 3 Selection: pg 4 Accessories: pgs 5 – 7 Tech data: pgs 8 – 9 Dimensions: pgs 10 – 13<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.<br />
Discount schedule ABA<br />
7
Technical data<br />
Technical data<br />
Type <strong>A145</strong> A185 A210 A260 <strong>A300</strong><br />
NEMA ratings<br />
NEMA size 4 — — 5 —<br />
NEMA cont. amp rating (thermal) 135 — — 270 —<br />
NEMA max. HP rating (3PH) 200V 40 — — 75 —<br />
230V 50 — — 100 —<br />
460V/575V 100 — — 200 —<br />
UL / CSA data<br />
Continuous ampere rating A 230 250 300 350 400<br />
Motor rating 3-phase 208V HP 40 50 60 75 100<br />
240V HP 50 60 75 100 100<br />
460/480V HP 100 125 150 200 250<br />
575/600V HP 125 150 200 250 300<br />
Insulation characteristics<br />
Rated insulation voltage U i<br />
according to IEC 947-4-1 and VDE 0110 (Gr. C) V 1000<br />
according to UL/CSA V 600<br />
Rated impulse withstand voltage U imp.<br />
8 kV<br />
Main pole utilization characteristics<br />
Rated operational voltage U e V 1000<br />
Conventional free-air thermal current I th<br />
acc. to IEC 947-4-1, open <strong>contactors</strong> q ≤ 40°C A 250 275 350 400 450<br />
with conductor cross-sectional area mm2 120 150 185 240 300<br />
Rated operational current I e /AC-1 for air temperature<br />
close to contactor<br />
q ≤ 40°C A 250 275 350 400 450<br />
q ≤ 55°C A 230 250 300 350 400<br />
q ≤ 70°C A 180 180 240 290 325<br />
with conductor cross-sectional area mm2 120 150 185 240 300<br />
M<br />
3<br />
{<br />
Utilization category AC-3 for air temperature<br />
close to contactor max. 55°C<br />
Rated operational current I e /AC-3<br />
220 – 230 – 240 V A 145 185 210 260 305<br />
3-phase motors 380 – 400 V A 145 185 210 260 305<br />
415 V A 145 185 210 260 300<br />
440 V A 145 185 210 240 280<br />
500 V A 145 170 210 240 280<br />
690 V A 120 170 210 220 280<br />
Rated operational power AC-3<br />
220 – 230 – 240 V kW 45 55 59 80 90<br />
1500 rpm – 50Hz 380 – 400 V kW 75 90 110 140 160<br />
1800rpm – 60Hz 415 V kW 75 90 110 140 160<br />
3-phase motors M<br />
440 V kW 75 90 110 140 160<br />
3<br />
500 V kW 90 110 132 180 200<br />
690 V kW 110 132 160 200 250<br />
Max. mechanical switching frequency cycles/h 3600 3600 3600 3600 3600<br />
Max. electrical switching for AC-1 cycles/h 300 300 300 300 300<br />
frequency for AC-3 cycles/h 300 300 300 300 300<br />
for AC-4 cycles/h 150 150 150 150 150<br />
Rated making capacity AC-3<br />
12 x I e AC-3<br />
Rated breaking capacity AC-3<br />
8 x I e AC-3<br />
Short-circuit protection for <strong>contactors</strong><br />
without thermal O/L relays – Motor protection excluded<br />
U e ≤ 500 V a.c. – gG (gl) type fuses A 315 355 400 500 500<br />
Rated short-time withstand current I cw 1 s A 1800 2000 2500 3500 3500<br />
at 40°C ambient temp., in free air, 10 s A 1200 1500 1700 2400 2400<br />
from a cold state 30 s A 800 1000 1200 1500 1500<br />
1 min A 600 800 1000 1100 1100<br />
15 min A 280 320 400 500 500<br />
Heat dissipation per pole I e /AC-1 W 13 16 18 25 32<br />
I e /AC-3 W 5 8 9 14 18<br />
Maximum short circuit rating, UL/CSA<br />
MCP Amps/kA @ 480V 400 / 85 400 / 85 800 / 85 800 / 85 800 / 85<br />
MCP Amps/kA @ 600V 400 / 35 400 / 35 800 / 35 800 / 35 800 / 35<br />
Fuse Amps/kA @ 600V 400J / 200 400J / 200 600J / 200 600J / 200 600J / 200<br />
Table of contents: pg 2 Alphanumeric: pg 3 Selection: pg 4 Accessories: pgs 5 – 7 Tech data: pgs 8 – 9 Dimensions: pgs 10 – 13<br />
AC 1035 — 10/1999<br />
8 <strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.
AC 1035 — 10/1999<br />
Technical data<br />
Magnet system characteristics<br />
Type A 145 A 185 A 210 A 260 A 300<br />
Coil operating limits acc. to IEC 947-4-1: 0.85 – 1.1 x U c max 70°C<br />
Drop-out voltage in % of U c roughly 45 – 65 %<br />
Coil consumption<br />
Average pull-in value 50 Hz VA 550 550 1350 1350 1350<br />
60 Hz VA 600 600 1550 1550 1550<br />
50/60 Hz VA/VA 700/650 700/650 1700/1550 1700/1550 1700/1550<br />
Average holding value 50 Hz VA/W 35/11 35/11 60/16 60/16 60/16<br />
60 Hz VA/W 40/12 40/12 65/19 65/19 65/19<br />
50/60 Hz VA/W 44/13 44/13 80/21 80/21 80/21<br />
Rated control circuit voltage Uc<br />
at 50 Hz V 24 – 690 24 – 690 24 – 690 24 – 690 24 – 690<br />
at 60 Hz V 24 – 600 24 – 600 24 – 600 24 – 600 24 – 600<br />
Operating time<br />
Between coil energization and:<br />
N.O. contact closing ms 13 – 27 13 – 27 17 – 35 17 – 35 17 – 35<br />
N.C. contact opening ms 8 – 22 8 – 22 12 – 30 12 – 30 12 – 30<br />
Between coil de-energization and:<br />
N.O. contact opening ms 5 – 10 5 – 10 7 – 13 7 – 13 7 – 13<br />
N.C. contact closing ms 9 – 13 9 – 13 10 – 16 10 – 16 10 – 16<br />
Approximate weight<br />
Contactor lbs 7.10 7.10 13.0 13.0 13.0<br />
Starter lbs 9.11 9.11 17.67 17.67 17.67<br />
Technical data<br />
Table of contents: pg 2 Alphanumeric: pg 3 Selection: pg 4 Accessories: pgs 5 – 7 Tech data: pgs 8 – 9 Dimensions: pgs 10 – 13<br />
<strong>ABB</strong> <strong>Control</strong> <strong>Inc</strong>.<br />
9