17.11.2014 Views

Catalyst 4500-X Fixed 10 GE Aggregation Switch

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PAGP<br />

1. IF Standby loses contact with Active, it assumes Active peer has<br />

failed, and so it transitions to Active state.<br />

• Now there are “dual actives.”<br />

2. The new Active sends out new active switch ID over the trusted<br />

MEC in PAgP frames.<br />

• (ePAgP uses TLV to carry new Active SW ID)<br />

Si<br />

Si<br />

3. Original Active switch sees new active sw-id on MEC and begins<br />

Dual Active Recovery operations on itself:<br />

• All non-VSL interfaces are error-disabled<br />

• It waits in “recovery mode” until the VSL is operational.<br />

• Once VSL is recovered, former Active reloads, boots into<br />

Standby mode, and the formerly error-disabled ports are reenabled<br />

after bootup.<br />

If the VSL fails, the standby sends<br />

PAgP with TLV containing (new) Active<br />

<strong>Switch</strong> ID. Original Active reacts by<br />

error-disabling all non-VSL ports.<br />

© 2011 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 61