525 Solutions - Tri-Net Technology
525 Solutions - Tri-Net Technology
525 Solutions - Tri-Net Technology
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Application Diagram © 1998 <strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong><br />
Enhanced Category 5 Power Sum<br />
25-Pair Cabling Systems<br />
True Category 5 25-Pair<br />
Trunk Cabling <strong>Solutions</strong><br />
by<br />
CAT5<br />
66 Block<br />
Fast Ethernet Hub<br />
(CISCO Catalyst 5000)<br />
with Telco 50 Pin Module<br />
Work Area<br />
Outlet<br />
Solution #1<br />
HighSpeed<br />
Patch Cords<br />
Assembled and tested by:<br />
10/100 Base-T Fast Ethernet Connectivity <strong>Solutions</strong><br />
100Base-TX<br />
Telco 50 Modular<br />
Jack Panel<br />
Pins 1,2,3,&6<br />
Active<br />
True CAT5<br />
25-Pair Trunk<br />
Cables<br />
CAT5 Telco 50 RJ-45<br />
Modular Jack Pane<br />
Pins 1 to 8<br />
Active<br />
CAT5 Zone<br />
Wiring Surface<br />
Box - 110 Type<br />
True CAT5<br />
Zone Wiring<br />
Box<br />
<strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong>, Inc.<br />
Total <strong>Net</strong>work Telesis<br />
U.S.A.<br />
<strong>525</strong> Connectors and<br />
Connectorized Assemblies<br />
Compatible where you want them to be Easy Upgrades<br />
Lucent Technologies<br />
Lucent Technologies<br />
<strong>525</strong> Connectors are the<br />
<strong>525</strong> Connectors<br />
first products of their kind<br />
provide a user-friendly<br />
to offer full backward and<br />
migration path from<br />
forward compatibility. Unlike<br />
today’s technologies --<br />
competitive products,<br />
including the widely<br />
Lucent Technologies<br />
deployed 10BASE-T --<br />
<strong>525</strong> Connectors maintain<br />
to sophisticated,<br />
a standard pinout which<br />
high-performance<br />
ensures compatibility<br />
ATM, 100BASE-TX,<br />
between hubs and connectors<br />
Gigabit Ethernet<br />
and eliminates confusion<br />
applications such as<br />
during installation.<br />
CISCO Catalyst 5000 series.<br />
Better Performance<br />
Lucent Technologies <strong>525</strong> connectors<br />
have a generous 6 dB margin -- which<br />
cuts crosstalk in half and assures<br />
Category 5 performance throughout<br />
systems that use multiple connectors<br />
(e.g. patch panels).<br />
Less Margin for Error<br />
The unique design of the <strong>525</strong> Connector features notches in the skirt to<br />
facilitate the use of a keyed connector on equipment. Such keyed<br />
connectors prevent accidental connection of low-performing Category 3<br />
and 4 cable assemblies to high-speed LAN equipment. A standard pinout<br />
ensures that connectors and hubs are compatible and eliminates confusion<br />
during installation.<br />
Quality and Reliability In A Host of Features:<br />
• Rigorous factory testing ensures high quality.<br />
• Notches in skirt facilitate the use of keyed equipment connectors, such as the<br />
Berg Electronics right angle Category 5 PWB connector.<br />
• Meets ANSI/EIA/TIA/568A Category 5 requirements, as well as FCC Part 68<br />
pinout requirements.<br />
• Exceeds Category 5 Power Sum Near-End Crosstalk (PSNEXT) requirements by<br />
an average factor of 6 dB (the noise level is less than half the maximum allowed).<br />
• Cable assemblies utilize UL ® -Listed, UL-Verified Category 5 25-pair 1061C<br />
Cable.<br />
• Assemblies are available in single-ended and double-ended versions of various<br />
lengths.<br />
• Side-by-side termination of conductors assures that twists can be maintained up<br />
to the termination point.<br />
<strong>525</strong> Connector & Category 5<br />
Cable Components Provided by:
Lucent Technologies <strong>525</strong> 25-Pair Connectors<br />
Mandrel: Special grooves on the mandrel allow insulated<br />
conductors to be anchored in position, preparing them for<br />
proper insertion in the connector housing. In each<br />
mandrel, all 25 pairs (50 conductors) are terminated side<br />
by side in numerical order. This design, plus the unique<br />
honeycomb mini-unit construction of the 1061C cable,<br />
simplifies the termination procedure. Pair twists are<br />
maintained up to the edge of the mandrel, assuring that<br />
the connector’s impressive crosstalk performance is not<br />
compromised.<br />
Housing: The internal leadframe of the housing forms the<br />
mating pins for each connector. Leadframe IDCs at the<br />
rear pierce through conductor insulation for easy<br />
installation . A metal crimp ring strain relief provides<br />
pull-out retention.<br />
Lucent Technologies <strong>525</strong> 1061C/2061A 25 -Pair Cable<br />
• Meets proposed EIA/TIA 568A requirements for CAT 5 backbone cables including<br />
Power Sum Near End Crosstalk (NEXT), swept attenuation and SRI.<br />
• Performance independently verified by UL including follow-up service requirements.<br />
• Unique seven sub-unit honeycomb construction eases termination.<br />
• Small cable diameter and superb flexibility due to the absence of cumbersome<br />
inner jackets, core wraps, tubes, shields and binders.<br />
• 25-Pair PIC color code for easy installation on 110 and Telco connectors.<br />
Hood: The hood is designed to snap onto the fully<br />
terminated connector thus protecting the conductors.<br />
Clear Category 5 labeling minimizes the potential of<br />
accidental connection to non-CAT5 connectors in a<br />
CAT5 system. An easy-to-remove dust cover is<br />
included with every connector and connectorized cable<br />
assembly.<br />
90 o 110 o left / right<br />
180 o<br />
angle<br />
Let <strong>Tri</strong>-<strong>Net</strong> custom make these versatile cables for your specific connectivity needs.<br />
Ordering Information<br />
Cable Type<br />
PVC<br />
Plenum<br />
04A<br />
04B<br />
Connectors<br />
(M)ale / (F)emale<br />
Female available only in 90 o Hood<br />
Single or Double<br />
Ended<br />
25<br />
50<br />
Hood Angles<br />
90 o 9 L/R<br />
110 o 4 L/R<br />
180 o 1<br />
1<br />
Pins 25<br />
26 50<br />
Pins<br />
1<br />
26<br />
Cable Length<br />
XX<br />
Custom<br />
Lengths<br />
in ft(s)<br />
Example Part #: 04A - MF - 4L1R - 05<br />
PVC cable - double-ended, male-110 o left angle to female 90 o right angle hoods - 5ft long<br />
Custom Octopus Cables Assembly<br />
• Male or female Telco 50 pin to 12 pieces of Category 5,<br />
2 pair cable terminated with RJ-45 plugs, pin 1,2,3 and 6 active<br />
• Connectors - For 10 Base-T / Ethernet<br />
AMP Champ, 035 series<br />
For 100 Base-TX / Fast Ethernet<br />
Lucent Technologies <strong>525</strong> Connectors, 03B series<br />
• Cable - ETL/UL Verified Category 5, 2 Pair,<br />
Stranded cable in gray or black color<br />
10 Base-T<br />
100 Base-T<br />
Application - Connector<br />
AMP<br />
Champ<br />
Lucent<br />
<strong>525</strong> Connectors<br />
035<br />
03B<br />
Hood Angles<br />
90 o 9 L/R<br />
110 o 4 L/R<br />
180 o 1<br />
Example Part #: 03B - 412 - M9L - 84 - 05<br />
(set)<br />
(set)<br />
Connectors<br />
(M)ale / (F)emale<br />
** Female available<br />
only in 90 o Hood<br />
Cable Length<br />
XX<br />
Custom<br />
Lengths<br />
in ft(s)
Let <strong>Tri</strong>-<strong>Net</strong> be your one-stop source for all your fast Ethernet components<br />
Fast Ethernet Hub<br />
(CISCO Catalyst 5000)<br />
with RJ-45 Module<br />
True CAT5<br />
Octopus<br />
Cable<br />
100Base-TX<br />
Telco 50 Modular<br />
Jack Panel<br />
Pins 1,2,3 & 6<br />
Active<br />
Modular Patch Panels<br />
TELCO 50 PIN TYPE - LUCENT TECHNOLOGIES 2500 & 2512 SERIES<br />
2500 series - 6 RJ-45 jacks (pin 1 thru 8 active)<br />
to one Telco 50 pin female connector<br />
2512 series - 12 RJ-45 jacks (pin 1, 2, 3 and 6 active)<br />
to one Telco 50 pin female connector<br />
Ordering Information<br />
High Speed<br />
Patch<br />
Cords<br />
CAT5 Telco 50 RJ-45<br />
Modular Jack Pane<br />
Pins 1 to 8<br />
Active<br />
Part Number<br />
ATT-108236142<br />
ATT-108236159<br />
ATT-108236167<br />
Telco 50 Pin<br />
(back view)<br />
Description<br />
RJ-45, 8 wire loaded, 24 port Telco 50 pin modular patch panel,<br />
568B Wiring<br />
RJ-45, 8 wire loaded, 48 port Telco 50 pin modular patch panel,<br />
568B Wiring<br />
RJ-45, 4 wire loaded ( pin 1,2,3 & 6 active ) 48 port,<br />
Telco 50 pin modular patch panel, 100 Base-TX Wiring<br />
110 TYPE - LUCENT TECHNOLOGIES 1100 SERIES AND TRI-NET TECHNOLOGY’S 01B SERIES<br />
The rear of panel features 110D Connecting Blocks mounted on a printed wiring board.<br />
Ordering Information<br />
Lucent Technologies Power Sum Category 5 110 type modular patch panel<br />
ATT-107914533 24 ports, 568B wiring<br />
ATT-107914558 48 ports, 568B wiring<br />
ATT-107914582 24 ports, 568A wiring<br />
ATT-107914590 48 ports, 568A wiring<br />
CAT5 Zone<br />
Wiring Box<br />
Telco 50 Pin to<br />
110 Connecting<br />
Bloock<br />
True CAT5<br />
25-Pair Trunk<br />
Cables<br />
CAT5 Zone<br />
Wiring Surface<br />
Box - 110 Type<br />
<strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong><br />
01B-824-0-88-258A<br />
01B-848-0-88-258A<br />
01B-824-0-88-568A<br />
01B-848-0-88-568A<br />
Power Sum Category 5 110 type modular patch panel<br />
24 ports, 568B wiring<br />
48 ports, 568B wiring<br />
24 ports, 568A wiring<br />
48 ports, 568A wiring<br />
4-Pair<br />
Cable<br />
RJ-45 JACK TO RJ-45 JACK FEED THRU PANEL<br />
110 Type<br />
(back view)<br />
Application Diagram © 1998 <strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong><br />
HighSpeed<br />
Patch Cords<br />
True CAT5<br />
Zone Wiring<br />
Box<br />
Category 5 RJ - 45 Jack to RJ-45 Jack in-line coupler enclosed in a<br />
19 inch mountable rack panel<br />
Ordering Information<br />
<strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong><br />
01E-12 - 12 Port Category 5 Feed thru Panel<br />
01E-24 - 24 Port Category 5 Feed thru Panel<br />
01E-48 - 48 Port Category 5 Feed thru Panel<br />
Lucent Technologies<br />
<strong>525</strong> Connectors<br />
100 Base-TX Applications<br />
03B-412-<br />
M<br />
F<br />
Solution #2<br />
9 L<br />
9 R<br />
4 L<br />
4 L<br />
1<br />
Octopus Cable<br />
Ordering Information<br />
-84-T-XX<br />
AMP Champ<br />
Connectors<br />
10 Base-TX Applications<br />
9 L<br />
M<br />
9 R<br />
035-412- F -84-T-XX<br />
1<br />
Patch Cords<br />
Lucent Technologies<br />
CAT 5, modular 4-Pair patch cords<br />
Enhanced cords meet PowerSum NEXT<br />
ATT-107748048<br />
ATT-107748063<br />
ATT-107748306<br />
ATT-107748105<br />
ATT-107748188<br />
ATT-107742322<br />
Assembled and tested by:<br />
<strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong>, Inc.<br />
Total <strong>Net</strong>work Telesis<br />
3ft.<br />
5ft.<br />
7ft.<br />
10ft.<br />
15ft.<br />
25ft.<br />
U.S.A.<br />
see<br />
Solution #3<br />
<strong>525</strong> Connector & Category 5<br />
Cable Components Provided by:
Application Diagram © 1998 <strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong><br />
Fast Ethernet Hub<br />
(CISCO Catalyst 5000)<br />
Telco 50-Pin Module<br />
4-Pair<br />
Cables<br />
Work Area<br />
Outlet<br />
Bulk Cables<br />
Solution #3<br />
True CAT5<br />
Octopus<br />
Cable<br />
High Speed Patch Cords<br />
Rear<br />
View<br />
HighSpeed<br />
Patch Cords<br />
RJ-45 Modular Jack<br />
Feed-Thru Panel<br />
True CAT5<br />
Zone Wiring<br />
Box<br />
Lucent Technologies - PowerSum, Category 5<br />
Zone Wiring Boxes (Intermediate Distribution Frame / IDF)<br />
Split 25 pair cable to 6 4-Pair 110 connector or RJ-45 jacks.<br />
Designed as intermediate distribution frame for zone wiring<br />
applications.<br />
TELCO 50 PIN TO 6 OR 12 RJ-45 JACKS STYLE<br />
Lucent Technologies<br />
ATT-107962896 Telco 50 pin female to 6 RJ-45 Jacks Zone Wiring Box,<br />
568B Wiring, Ivory<br />
ATT-107962904 Telco 50 pin female to 6 RJ-45 Jacks Zone Wiring Box,<br />
568B Wiring, White<br />
065-412-F-84-T-C5 Telco 50 pin female to 12 RJ-45 Jacks Zone Wiring Box,<br />
pin 1,2,3 and 6 active, 100 Base-TX Wiring<br />
TELCO 50 PIN TO 110 CONNECTING BLOCKS<br />
Terminated 6 inches of Lucent Technologies <strong>525</strong> 25 pair connector to<br />
zone wiring block (Lucent Technologies P/N: ATT-ZWBC1-B-246)<br />
<strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong><br />
036-806-M(F) 6 inches Telco 50 pin male or female<br />
to 6 of 4 pair, 110 connecting blocks<br />
036-412-M(F) 6 inches Telco 50 pin male or female<br />
to 12 of 2 pair, 110 connecting blocks<br />
110 CONNECTING BLOCK TO RJ-45 STYLE<br />
Lucent Technologies<br />
6 RJ-45 Jacks to 6 4-Pair 110 Connecting Block surface box<br />
ATT-107984346 568B wiring, Ivory<br />
ATT-107984353 568B wiring, White<br />
ATT-107984080 568A wiring, Ivory<br />
ATT-107984098 568A wiring, White<br />
<strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong><br />
6 RJ-45 Jacks to 6 4-Pair 110 Connecting Block surface box<br />
074-S-06-258A-IV 568B wiring, Ivory<br />
074-S-06-258A-WH 568B wiring, White<br />
074-S-06-568A-IV 568A wiring, Ivory<br />
074-S-06-588A-WH 568A wiring, White<br />
Information Outlets<br />
MPS100 POWER SUM<br />
RJ-45 INFORMATION OUTLET<br />
Lucent Technologies<br />
• Application supports up to 622 Mbps<br />
• To use with M-Series modular faceplates,<br />
frames, or surface-mount boxes<br />
• 8 positions / 8 conductor non-keyed<br />
modular information outlet<br />
ATT - 107565491<br />
ATT - 107565<strong>525</strong><br />
ATT - 107565533<br />
Orange<br />
Ivory<br />
White<br />
Modular Face Plates<br />
Lucent Technologies<br />
• Mounting space 3.280”<br />
• Designed for use with M-series modular<br />
information outlets<br />
• Standard package includes faceplate and<br />
two screws<br />
ATT-106849714<br />
ATT-106462730<br />
ATT-106313653<br />
ATT-106688351<br />
Single, Elec. White<br />
Duplex, Elec. White<br />
Quadplex, Elec. White<br />
Quadplex, Elec. Gray<br />
ATT-1061-004<br />
ATT-1061-025R<br />
ATT-2061-004<br />
ATT-2061-025R<br />
CAT 5 UTP, 4-Pair, PVC, Solid<br />
CAT 5 UTP, 25-Pair, PVC, Solid<br />
CAT 5 UTP, 4-Pair, Plenum, Solid<br />
CAT 5 UTP, 25-Pair, Plenum, Solid<br />
<strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong>, Inc.<br />
Total <strong>Net</strong>work Telesis U.S.A.<br />
20529 Walnut Drive, B7 Walnut, CA 91789 •<br />
909-598-8818 • 909-594-8666 (fax)<br />
info@trinetusa.com<br />
www.trinetusa.com<br />
Copyright © 1998 <strong>Tri</strong>-<strong>Net</strong> <strong>Technology</strong>, Inc. All rights reserved.<br />
Cisco and the Cisco Systems logo are registered trademarks of Cisco Systems, Inc.<br />
Lucent Technologies and the Lucent Technologies logo are registered trademarks of Lucent Technologies, Inc.<br />
Distributed by<br />
08/98<br />
Media Code: 00004<br />
98