Independent tests* show that fan convectors are at least 24% more energy efficient than a panel radiator in <strong>heat</strong>ing up a room.<br />
*Tests carried out by BSRIA (Building Services Research and Information Association) in August 2008<br />
Heat Output ∆t 60ºC Heat Output ∆t 50ºC<br />
Normal Boost Normal Boost Fan- Flow & Return<br />
Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) Casing Colour 0nly Connections<br />
Hydronic CT18 3.5 (11900) 5.5 (18800) 2.8 (9600) 4.4 (15000) White • 22mm<br />
Electric E 4kW 4.0 n/a 4.0 n/a White • n/a<br />
∆t 60ºC assumes a mean water temperature of 80ºC and room temperature of 20ºC. ∆t 50ºC assumes a mean water temperature of 70ºC and room temperature of<br />
20ºC. Hydronic outputs tested in accordance with BS 4856. Fan-only option operational only when central <strong>heat</strong>ing system is switched off.<br />
Power Consumption<br />
Water<br />
Main Flexible Isolating Fused Normal Boost Capacity<br />
Model Cable Transformer Hoses Valves Spur Watts Watts (Litres)<br />
Hydronic CT18 1.5m n/a n/a n/a 3A 50 70 0.9<br />
Electric E 4kW 1.5m n/a n/a n/a 20A 4045 n/a n/a<br />
Skyline CT18<br />
Finish<br />
Outer casing 0.7mm zinc-coated steel.<br />
Polyester powder-coated.<br />
Paint specification: textured white<br />
BS 4800 00A01 18% gloss.<br />
Installation<br />
• Maximum installation height 3.2m<br />
(10'6") to underside<br />
• Installed to 180mm - penetration<br />
depth in recess (excluding fittings)<br />
• Four air inlet options: room only, void<br />
only, room and void, fresh air (spigot<br />
required)<br />
• 600mm side clearance required<br />
• Fixing brackets (4) supplied for<br />
connection to 6mm threaded rods or<br />
chains (rods and chains - not<br />
supplied)<br />
• Blanking plates (2) supplied for air<br />
circulation options<br />
• Unit must be earthed<br />
• Supplied with remote operating<br />
switch<br />
• Suitable for two-pipe central <strong>heat</strong>ing<br />
systems only<br />
Commissioning<br />
Check water temperature is hot enough<br />
to activate low temperature cut-out<br />
(LTC). The inclusion of an automatic<br />
air vent at the highest point is<br />
recommended to avoid possible<br />
air locks.<br />
Controls<br />
Two rocker fan switches -<br />
normal/off/boost, fan-<strong>heat</strong>ing/fan-only.<br />
Low temperature cut-out thermostat set<br />
to energise fan at approx. 42ºC (108ºF).<br />
Accessories<br />
Wall-mounted room thermostat with<br />
on/off switch. Fresh air inlet spigot to<br />
suit 100mm flexible hose.<br />
90<br />
Skyline CT18<br />
Pipe Centres<br />
22<br />
28<br />
22mm<br />
Flow and Return Pipes<br />
Outlet panel fits over<br />
ceiling tile frame<br />
Air in void or room<br />
damper at both ends<br />
45<br />
centres<br />
280<br />
248<br />
centres<br />
600<br />
542<br />
516<br />
centres<br />
All dimensions in mm<br />
Skyline E 4kW<br />
Heat exchanger<br />
drain off valve<br />
Fixing points<br />
507<br />
600<br />
498<br />
centres<br />
15<br />
264<br />
151<br />
90<br />
100<br />
555<br />
600<br />
600<br />
Skyline E 4kW<br />
Finish<br />
Outer casing 0.9mm zinc-coated steel.<br />
Polyester powder-coated.<br />
Paint specification: textured white<br />
BS 4800 00A01 18% gloss.<br />
Installation<br />
• Maximum installation height 3.2m<br />
(10'6") to underside<br />
• Minimum 150mm void space required<br />
for recessed installation<br />
• Not suitable for bathrooms and other<br />
high humidity areas<br />
• Two air inlet options: room only,<br />
room and void<br />
• Maximum flexibility in installation:<br />
only 600mm - side clearance required<br />
• Facility for connection to 6mm<br />
threaded rod or chains (rods and<br />
chains - not supplied)<br />
• 20 amp fused spur required<br />
• Unit must be earthed<br />
• Supplied with remote operating<br />
switch<br />
Controls<br />
Rocker switches for fan and element.<br />
Over<strong>heat</strong> protection: thermal cut-out.<br />
Manual reset procedure: switch power<br />
off at mains, wait 5 minutes, switch<br />
power on.<br />
Room thermostats used in conjunction<br />
with this product must be rated at<br />
16A minimum.<br />
Accessories<br />
Surface mounting kit - 135mm. Provides<br />
a complete four-sided trim when fitted<br />
to a solid ceiling.<br />
Ceiling tile spacer - 85mm. Provides<br />
semi-recessed profile to match Skyline<br />
CT18 when used in ceiling tile frame.<br />
Multiple positions (14) for suspension points<br />
33