18.11.2014 Views

Smith's heat emiters - Artizan Heating

Smith's heat emiters - Artizan Heating

Smith's heat emiters - Artizan Heating

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Independent tests* show that fan convectors are at least 24% more energy efficient than a panel radiator in <strong>heat</strong>ing up a room.<br />

*Tests carried out by BSRIA (Building Services Research and Information Association) in August 2008<br />

Heat Output ∆t 60ºC Heat Output ∆t 50ºC<br />

Normal Boost Normal Boost Fan- Flow & Return<br />

Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) Casing Colour 0nly Connections<br />

Hydronic CT18 3.5 (11900) 5.5 (18800) 2.8 (9600) 4.4 (15000) White • 22mm<br />

Electric E 4kW 4.0 n/a 4.0 n/a White • n/a<br />

∆t 60ºC assumes a mean water temperature of 80ºC and room temperature of 20ºC. ∆t 50ºC assumes a mean water temperature of 70ºC and room temperature of<br />

20ºC. Hydronic outputs tested in accordance with BS 4856. Fan-only option operational only when central <strong>heat</strong>ing system is switched off.<br />

Power Consumption<br />

Water<br />

Main Flexible Isolating Fused Normal Boost Capacity<br />

Model Cable Transformer Hoses Valves Spur Watts Watts (Litres)<br />

Hydronic CT18 1.5m n/a n/a n/a 3A 50 70 0.9<br />

Electric E 4kW 1.5m n/a n/a n/a 20A 4045 n/a n/a<br />

Skyline CT18<br />

Finish<br />

Outer casing 0.7mm zinc-coated steel.<br />

Polyester powder-coated.<br />

Paint specification: textured white<br />

BS 4800 00A01 18% gloss.<br />

Installation<br />

• Maximum installation height 3.2m<br />

(10'6") to underside<br />

• Installed to 180mm - penetration<br />

depth in recess (excluding fittings)<br />

• Four air inlet options: room only, void<br />

only, room and void, fresh air (spigot<br />

required)<br />

• 600mm side clearance required<br />

• Fixing brackets (4) supplied for<br />

connection to 6mm threaded rods or<br />

chains (rods and chains - not<br />

supplied)<br />

• Blanking plates (2) supplied for air<br />

circulation options<br />

• Unit must be earthed<br />

• Supplied with remote operating<br />

switch<br />

• Suitable for two-pipe central <strong>heat</strong>ing<br />

systems only<br />

Commissioning<br />

Check water temperature is hot enough<br />

to activate low temperature cut-out<br />

(LTC). The inclusion of an automatic<br />

air vent at the highest point is<br />

recommended to avoid possible<br />

air locks.<br />

Controls<br />

Two rocker fan switches -<br />

normal/off/boost, fan-<strong>heat</strong>ing/fan-only.<br />

Low temperature cut-out thermostat set<br />

to energise fan at approx. 42ºC (108ºF).<br />

Accessories<br />

Wall-mounted room thermostat with<br />

on/off switch. Fresh air inlet spigot to<br />

suit 100mm flexible hose.<br />

90<br />

Skyline CT18<br />

Pipe Centres<br />

22<br />

28<br />

22mm<br />

Flow and Return Pipes<br />

Outlet panel fits over<br />

ceiling tile frame<br />

Air in void or room<br />

damper at both ends<br />

45<br />

centres<br />

280<br />

248<br />

centres<br />

600<br />

542<br />

516<br />

centres<br />

All dimensions in mm<br />

Skyline E 4kW<br />

Heat exchanger<br />

drain off valve<br />

Fixing points<br />

507<br />

600<br />

498<br />

centres<br />

15<br />

264<br />

151<br />

90<br />

100<br />

555<br />

600<br />

600<br />

Skyline E 4kW<br />

Finish<br />

Outer casing 0.9mm zinc-coated steel.<br />

Polyester powder-coated.<br />

Paint specification: textured white<br />

BS 4800 00A01 18% gloss.<br />

Installation<br />

• Maximum installation height 3.2m<br />

(10'6") to underside<br />

• Minimum 150mm void space required<br />

for recessed installation<br />

• Not suitable for bathrooms and other<br />

high humidity areas<br />

• Two air inlet options: room only,<br />

room and void<br />

• Maximum flexibility in installation:<br />

only 600mm - side clearance required<br />

• Facility for connection to 6mm<br />

threaded rod or chains (rods and<br />

chains - not supplied)<br />

• 20 amp fused spur required<br />

• Unit must be earthed<br />

• Supplied with remote operating<br />

switch<br />

Controls<br />

Rocker switches for fan and element.<br />

Over<strong>heat</strong> protection: thermal cut-out.<br />

Manual reset procedure: switch power<br />

off at mains, wait 5 minutes, switch<br />

power on.<br />

Room thermostats used in conjunction<br />

with this product must be rated at<br />

16A minimum.<br />

Accessories<br />

Surface mounting kit - 135mm. Provides<br />

a complete four-sided trim when fitted<br />

to a solid ceiling.<br />

Ceiling tile spacer - 85mm. Provides<br />

semi-recessed profile to match Skyline<br />

CT18 when used in ceiling tile frame.<br />

Multiple positions (14) for suspension points<br />

33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!