Sterling™ Balloon Dilatation Catheter
Sterling™ Balloon Dilatation Catheter
Sterling™ Balloon Dilatation Catheter
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Home<br />
Products Committed to PI Download Center News & Events Customer Support Reimbursement<br />
Home > Products<br />
Product Finder:<br />
View Featured Products<br />
View All Products<br />
Narrow Products By:<br />
Category<br />
Angiographic <strong>Catheter</strong><br />
<strong>Balloon</strong> <strong>Catheter</strong><br />
<strong>Balloon</strong>-Expandable Stent<br />
Coil<br />
Embolic Protection System<br />
Embolization Particles<br />
Guidewire<br />
Introducer Sheath<br />
Microcatheter<br />
Self-Expanding Stent<br />
Procedure<br />
Biliary Stenting<br />
Carotid Artery Stenting<br />
CryoPlasty Therapy<br />
Hypervascular Tumor<br />
Embolization<br />
Percutaneous Drainage<br />
Percutaneous Transluminal<br />
Angioplasty (PTA)<br />
Peripheral Stenting<br />
Uterine Fibroid Embolization<br />
(UFE)<br />
Vessel Occlusion<br />
Sterling <strong>Balloon</strong> <strong>Dilatation</strong> <strong>Catheter</strong><br />
Overview<br />
Contact Us About This Product<br />
Product Information<br />
The Sterling <strong>Balloon</strong> <strong>Dilatation</strong> <strong>Catheter</strong> meets the challenges of renal and lower<br />
extremity anatomy with a powerful combination of deliverability and trackability--<br />
resulting in clinical versatility. Excellent trackability in both Over-the-Wire and rapid<br />
exchange platforms, plus a broad size offering, provide multiple solutions for all of your<br />
peripheral intervention needs.<br />
Clinical Versatility<br />
Over-the-Wire and rapid exchange platforms for use in the peripheral vasculature<br />
Extensive size matrix:<br />
<strong>Balloon</strong> diameters of 3mm-10mm<br />
<strong>Balloon</strong> lengths of 10mm-100mm<br />
Three shaft lengths of 40cm, 80cm and 135cm<br />
Specifically designed for use in renal and lower extremity arteries and dialysis<br />
fistulae<br />
Breakthrough Deliverability<br />
Ultra-low balloon profile is 4F introducer sheath compatible up through 8mm x<br />
40mm<br />
Laser-Bonded, tapered tip promotes crossability through tight stenoses and near<br />
occlusions<br />
Semi-compliant Pebax® <strong>Balloon</strong> Material with hydrophilic coating facilitates<br />
advancement through complex lesions<br />
Assured Trackability<br />
Lubricious inner shaft and seamless tip-to-shaft transitions enhance trackability<br />
Flexible tip and shaft promote easier navigation through tortuous vasculature<br />
Additional Product<br />
Information<br />
Prescriptive Information<br />
View prescriptive information<br />
Responsive Pushability<br />
Balanced coaxial shaft design features a flexible distal shaft for tracking, combined<br />
with a robust proximal shaft for powerful push<br />
Tack weld of distal inner and outer shaft improves column support, enabling<br />
advancement through challenging anatomy<br />
Full-length tapered core wire provides added support and kink resistance<br />
Device Illustration<br />
Device Highlights<br />
Coaxial Shaft<br />
Tapered Core Wire<br />
Tack Weld<br />
Semi-Compliant Pebax <strong>Balloon</strong> Material<br />
Laser-Bonded Tapered Tip<br />
Contact Us | Privacy Statement | Legal Information | About Us | Corporate Home<br />
©2012 Boston Scientific Corporation or its affiliates. All rights reserved.
Home<br />
Products Committed to PI Download Center News & Events Customer Support Reimbursement<br />
Home > Products<br />
Product Finder:<br />
View Featured Products<br />
View All Products<br />
Narrow Products By:<br />
Category<br />
Angiographic <strong>Catheter</strong><br />
<strong>Balloon</strong> <strong>Catheter</strong><br />
<strong>Balloon</strong>-Expandable Stent<br />
Coil<br />
Embolic Protection System<br />
Embolization Particles<br />
Guidewire<br />
Introducer Sheath<br />
Microcatheter<br />
Self-Expanding Stent<br />
Procedure<br />
Biliary Stenting<br />
Carotid Artery Stenting<br />
CryoPlasty Therapy<br />
Hypervascular Tumor<br />
Embolization<br />
Percutaneous Drainage<br />
Percutaneous Transluminal<br />
Angioplasty (PTA)<br />
Peripheral Stenting<br />
Uterine Fibroid Embolization<br />
(UFE)<br />
Vessel Occlusion<br />
Sterling Monorail® <strong>Balloon</strong> <strong>Dilatation</strong> <strong>Catheter</strong><br />
Overview<br />
Contact Us About This Product<br />
Product Information<br />
The Sterling <strong>Balloon</strong> <strong>Dilatation</strong> <strong>Catheter</strong> meets the challenges of carotid, renal and<br />
lower extremity anatomy with a powerful combination of deliverability and trackability--<br />
resulting in clinical versatility. Excellent trackability, plus a broad size offering, provide<br />
multiple solutions for all of your peripheral intervention needs.<br />
Clinical Versatility<br />
Rapid exchange platform for use in the peripheral vasculature<br />
Extensive size matrix:<br />
<strong>Balloon</strong> diameters of 3mm-8mm<br />
<strong>Balloon</strong> lengths of 10mm-100mm<br />
Three shaft lengths of 40cm, 80cm and 135cm<br />
Specifically designed for use in carotid*, renal and lower extremity arteries and<br />
dialysis fistulae<br />
Breakthrough Deliverability<br />
Ultra-low balloon profile is 4F introducer sheath compatible up through 8mm x<br />
40mm<br />
Laser-Bonded, tapered tip promotes crossability through tight stenoses and near<br />
occlusions<br />
Semi-compliant Pebax® <strong>Balloon</strong> Material with hydrophilic coating facilitates<br />
advancement through complex lesions<br />
Assured Trackability<br />
Lubricious inner shaft and seamless tip-to-shaft transitions enhance trackability<br />
Flexible tip and shaft promote easier navigation through tortuous vasculature<br />
Additional Product<br />
Information<br />
Prescriptive Information<br />
View prescriptive information<br />
Responsive Pushability<br />
Balanced coaxial shaft design features a flexible distal shaft for tracking, combined<br />
with a robust proximal shaft for powerful push<br />
Tack weld of distal inner and outer shaft improves column support, enabling<br />
advancement through challenging anatomy<br />
Full-length tapered core wire provides added support and kink resistance<br />
Device Illustration<br />
Device Highlights<br />
Coaxial Shaft<br />
Tapered Core Wire<br />
Tack Weld<br />
Semi-Compliant Pebax <strong>Balloon</strong> Material<br />
Laser-Bonded Tapered Tip<br />
Additional Information<br />
*Sterling Over-the-Wire <strong>Balloon</strong> <strong>Dilatation</strong> <strong>Catheter</strong>s are not indicated for use in the<br />
carotid vasculature.<br />
Contact Us | Privacy Statement | Legal Information | About Us | Corporate Home<br />
©2012 Boston Scientific Corporation or its affiliates. All rights reserved.