Determination of total protein content:<br />
Determination of Kjeldahl nitrogen<br />
The <strong>behr</strong> <strong>equipment</strong> <strong>for</strong> determination of Kjeldahl nitrogen offers the user a complete<br />
individually configurable solution <strong>for</strong> the laboratory.<br />
• Sample Digestion Units<br />
The sample digestion units of the <strong>behr</strong>otest® InKjel line are provided with<br />
powerful infra-red heating elements.<br />
The quality and positioning of the infra-red heating elements guarantee the user<br />
reproducible heating phases and digestion temperatures at all sample positions.<br />
This also pertains to the twelve sample digestion unit, in which the samples are<br />
arrayed in two rows of six each.<br />
Direct irradiation of the samples by the infra-red sources eliminates the painfully<br />
slow warm-up phase associated with conventional heating block units.<br />
InKjel 625 M<br />
Thus, the <strong>behr</strong>otest® InKjel is the ideal rapid digestion unit <strong>for</strong> the Kjeldahl<br />
nitrogen determination and other high temperature sample digestions.<br />
• Steam distillation units<br />
The <strong>behr</strong> steam distillation units of the „S“ model series are the optimal<br />
complement to the InKjel rapid digestion units.<br />
Depending on the user’s requirements, he may choose between one manual and<br />
two automatic steam distillation models. These are similar in concept, but differ<br />
in the level of automation and convenience features. The top-of-the-line model,<br />
the <strong>behr</strong> S 5, is designed to accept an external titrator.<br />
All <strong>behr</strong> steam distillation units have the following common features:<br />
— Powerful and fast<br />
— Practical and user-friendly<br />
— Exemplary safety and reliability<br />
— Sturdy chemically resistant stainless steeel housing<br />
— Practical quick-release vessel clamp permits easy use with right or left hand<br />
— Especially simple menu-driven operation of the programmable apparatus by<br />
means of one single control knob<br />
InKjel 625 P<br />
• Fume exhaust system<br />
The two-stage <strong>behr</strong>osog fume exhaust system – condensate trap plus<br />
neutralization stage – keeps all acid fumes completely out of the environment.<br />
• Titration stations<br />
The <strong>behr</strong>otest® STI manual titration station or an automatic titrator provide <strong>for</strong><br />
reliable, safe and rapid titration into complete the nitrogen determination.<br />
<strong>behr</strong>osog 2<br />
2
ehrotest ® InKjel Infra-red Rapid Digestion Units<br />
The basic units in the <strong>behr</strong>otest® InKjel model series hold insertable frames <strong>for</strong> different combinations of vessels:<br />
• 6 reaction vessels with 250 ml capacity in InKjel 625 (M or P)<br />
• 12 reaction vessels with 250 ml capacity in InKjel 1225 (M or P)<br />
• 4 reaction vessels with 500 ml capacity in InKjel 450 (M or P)<br />
• 4 reaction vessels with 750 ml capacity in InKjel 475 (M or P)<br />
If required, the user can re-equip his system himself very easily with different digestion boxes (insertable frame with suction<br />
extraction apparatus) <strong>for</strong> other sample glassware.<br />
The <strong>behr</strong>osog process suction system is available to extract vapours during digestion.<br />
All InKjel systems are completely equipped with tiered console, suction system, insertable frame and digestion glass vessels.<br />
InKjel Infra-red Rapid Digestion Units: Technical Specifications<br />
InKjel P programmable infra-red rapid digestion units<br />
Rated voltage:<br />
230 VAC/50 Hz<br />
Power:<br />
1500 W<br />
Dimensions (W x H x D): approx. 540 x 750 x 440 mm<br />
Weight:<br />
approx. 20 kg<br />
Programs: max. 99<br />
Time setting range:<br />
0 ... 199 min., in steps of 1 min.<br />
Heating power levels: 0 ... 100 %, in steps of 1 %<br />
SIMVAC<br />
InKjel M manually adjustable infra-red rapid digestion units<br />
Rated voltage:<br />
230 VAC/50 Hz<br />
Power:<br />
1500 W<br />
Dimensions (W x H x D): approx. 540 x 750 x 440 mm<br />
Weight:<br />
approx. 20 kg<br />
Heating power level: 0 ... 100 %, continuously adjustable<br />
<strong>behr</strong>osog 2 scrubber<br />
Rated voltage:<br />
Power:<br />
Dimensions (W x H x D):<br />
Weight:<br />
Pump suction flow rate:<br />
230 VAC/50 Hz<br />
80 W<br />
approx. 335 x 480 x 340 mm<br />
approx. 18 kg<br />
max. 40 l/min<br />
STI manual titration station<br />
Rated voltage:<br />
Dimensions (W x H x D):<br />
Weight:<br />
230 VAC/50 Hz<br />
approx. 330 x 600 x 200 mm<br />
approx. 3,5 kg<br />
STI<br />
3
Features S 1 S 2 S 3 S 4 S 5<br />
Manual addition of H 2<br />
O - + + + +<br />
Manual addition of NAOH + + + + +<br />
Manual addition of H 3<br />
BO 3<br />
- + + + +<br />
Automatic addition of H 2<br />
O - + + + +<br />
Automatic addition of NAOH - + + + +<br />
Automatic addition of H 3<br />
BO 3<br />
- - - + +<br />
Programmable reaction time - - + + +<br />
Programmable distillation time - + + + +<br />
S 1<br />
Automatic steam generation + + + + +<br />
Variable steam generating capacity (40% - 100%) - + + + +<br />
Automatic removal of sample residues by suction - - + + +<br />
Number of programs 0 1 1 99 99<br />
Display language can be chosen by the user - + + + +<br />
Visual error reports + + + + +<br />
Acoustic error reports - + + + +<br />
Serial interface (RS232) - + + + +<br />
Standby operation between the distillations + + + + +<br />
Level monitoring <strong>for</strong> the set of canisters + + + + +<br />
Various <strong>behr</strong>otest® digestion glassware types can<br />
be used<br />
+ + + + +<br />
Connection <strong>for</strong> titration unit - - - - +<br />
S 4<br />
Steam Distillation Units: Technical Specifications<br />
S 5 – TB 1<br />
Rated voltage:<br />
Power:<br />
Cooling water consumption:<br />
Distillation time:<br />
S 1 S 2 S 3 S 4 S 5<br />
230 VAC, 50 Hz<br />
1700 W<br />
approx. 5 l/min<br />
approx. 2 ... 3 min per sample<br />
Storage container: any size any size,<br />
recommendation: <strong>behr</strong>otest® set of canisters<br />
Interface: — RS232<br />
Display: — LCD<br />
Programs: 1 1 100 100<br />
Dimensions<br />
(W x H x D in mm)<br />
410 x 675 x 410<br />
Weight: 32 kg 34 kg 35 kg 35 kg 36 kg<br />
Connection <strong>for</strong> titrator: no no no no yes<br />
4
Digestion units<br />
804849998 InKjel 625 M Manually adjustable infra-red rapid digestion unit <strong>for</strong> six 250 ml sample vessels<br />
804849999 InKjel 1225 M Manually adjustable infra-red rapid digestion unit <strong>for</strong> twelve 250 ml sample vessels<br />
804849450 InKjel 450 M Manually adjustable infra-red rapid digestion unit <strong>for</strong> four 500 ml sample vessels<br />
804849475 InKjel 475 M Manually adjustable infra-red rapid digestion unit <strong>for</strong> four 750 ml sample vessels<br />
804850001 InKjel 625 P Programmable infra-red rapid digestion unit <strong>for</strong> six 250 ml sample vessels<br />
804850002 InKjel 1225 P Programmable infra-red rapid digestion unit <strong>for</strong> twelve 250 ml sample vessels<br />
804850003 InKjel 450 P Programmable infra-red rapid digestion unit <strong>for</strong> four 500 ml sample vessels<br />
804850004 InKjel 475 P Programmable infra-red rapid digestion unit <strong>for</strong> four 750 ml sample vessels<br />
804849225 InKjel 1225 PE Expansion slave module (without power controller) increases capacity of InKjel 1225 P to 24 samples<br />
804849445 InKjel 450 PE Expansion slave module (without power controller) increases capacity of InKjel 450 P to 8 samples<br />
804849446 InKjel 475 PE Expansion slave module (without power controller) increases capacity of InKjel 475 P to 8 samples<br />
Steam distillation units<br />
804849001 S 1 Steam distillation unit, manual operation, distillation time approx. 2 – 3 min.<br />
804849002 S 2 Steam distillation unit, programmable NaOH addition distillation time approx. 2 – 3 min.<br />
804849003 S 3 Steam dist. unit, programmable NaOH & water addition, distillation time approx. 2 – 3 min.<br />
804849004 S 4 Steam dist. unit, programmable NaOH, boric acid & water addition, distillation time approx. 2 – 3 min.<br />
80 48 49005 S 5 Steam dist. unit, fully automatic, accepts external titrator (e.g. TB 1)<br />
80 48 49006 TB 1 Titration accessory module <strong>for</strong> the S 5 steam distillation unit<br />
804849030 KAS 30 Reagent container set <strong>for</strong> S 3, consisting of three 20 liter containers with level sensors<br />
804849040 KAS 40 Reagent container set <strong>for</strong> S 4 and S 5 consisting of four 20 liter containers with level sensors<br />
Catalyst tablets <strong>for</strong> the Kjeldahl determination<br />
804840103 KT 3 Catalyst tablets (3.5 g K 2 SO 4 ; 0.4 g CuSO 4 ), tin of 1,000 tablets<br />
804840100 KT 1 Catalyst tablets (5.0 g K 2 SO 4 ; 0.5 g CuSO 4 ), tin of 1,000 tablets<br />
804840101 KT 2 Catalyst tablets (5.0 g K 2 SO 4 ; 0.15 g CuSO 4 ; 0.15 g TiO 2 ), tin of 1,000 tablets<br />
804840102 AFS Anti-foam tablets<br />
Fume evacuators<br />
804840005 SIMVAC Fume evacuator with water jet pump and neutralization bottle, incl. tube and rack<br />
804840004 <strong>behr</strong>osog 2 Fume evacuator/neutralization unit with vacuum pump, 40 l/h<br />
Manual Titration Station<br />
804842020 STI Manual titration station <strong>for</strong> the Kjeldahl nitrogen determination<br />
Accessories <strong>for</strong> the Kjeldahl determination<br />
804840104 WB 1 Kjeldahl weighing boats, nitrogen free parchment paper<br />
804841015 SR 3i Round-bottom digestion vessel without std. taper mouth <strong>for</strong> InKjel digestion unit<br />
804851051 KJ 500 Round-bottom digestion vessel, 500 ml, <strong>for</strong> InKjel<br />
804851076 KJ 750 Round-bottom digestion vessel, 750 ml, <strong>for</strong> InKjel<br />
804849983 EG 6 Vessel holding frame <strong>for</strong> six 250 ml SR 3i vessels in the InKjel 625 digestion unit<br />
804849984 EG 12 Vessel holding frame <strong>for</strong> twelve 250 ml SR 3i vessels in the InKjel 1225 digestion unit<br />
804849982 EG 4/500 Vessel holding frame <strong>for</strong> four 500 ml KJ 500 vessels in the InKjel 450 digestion unit<br />
804849978 EG 4/750 Vessel holding frame <strong>for</strong> four 750 ml KJ 750 vessels in the InKjel 475 digestion unit<br />
804849986 AE 6 Fume exhaust manifold <strong>for</strong> InKjel 625<br />
804849987 AE 12 Fume exhaust manifold <strong>for</strong> InKjel 1225<br />
804849985 AE 4 Fume exhaust manifold <strong>for</strong> InKjel 450 and InKjel 475<br />
5
Soxhlet Extraction<br />
The standard method <strong>for</strong> the determination<br />
of free fat in <strong>foodstuffs</strong> is the Soxhlet extraction.<br />
<strong>behr</strong> <strong>equipment</strong> <strong>for</strong> the extraction fulfils<br />
the most varied requirements of daily<br />
laboratory use.<br />
• Extractor sizes from 30 to 250 ml.<br />
• Kompakt units <strong>for</strong> single sample<br />
processing.<br />
• Heating block units with especially<br />
exact temperature control <strong>for</strong><br />
simultaneously processing up to<br />
6 samples.<br />
• Extraction systems <strong>for</strong> four or six<br />
samples with linear configuration of<br />
individual extrators.<br />
• Extractors with a specially developed<br />
siphon tube guarantee uni<strong>for</strong>mity of<br />
extraction in all sample positions.<br />
• Extractors provided with spigots<br />
<strong>for</strong> draining solvent obviate need to<br />
distill solvent be<strong>for</strong>e reuse.<br />
• No rotary evaporator is required.<br />
Use of the hydrolysis glassware kit<br />
(<strong>for</strong> 1, 4 or 6 sample units) enables acid<br />
digestion to be per<strong>for</strong>med prior to extraction<br />
in accordance with the Weibull<br />
and Stoldt method <strong>for</strong> determination of<br />
total fat content.<br />
Kompakt systems <strong>for</strong> Soxhlet extraction<br />
804800520 KEX 30 Kompakt-system <strong>for</strong> 30 ml extraction<br />
804800522 KEX 100 F Kompakt-system <strong>for</strong> 100 ml extraction, w/ spigot<br />
804800536 KEX 250 F Kompakt-system <strong>for</strong> 250 ml extraction, w/ spigot<br />
Approx. dimensions<br />
(H x W x D in cm)<br />
KEX 30 KEX 100 KEX 250<br />
71,5 x 23 x 33 71,5 x 23 x 33 80 x 23 x 33<br />
Weight 7,5 kg 7,5 kg 7,5 kg<br />
Line voltage 230 VAC, 50/60 Hz 230 VAC, 50/60 Hz 230 VAC, 50/60 Hz<br />
Power rating 450 W 450 W 450 W<br />
KEX 100 F<br />
Equipment <strong>for</strong> Soxhlet extraction, 5 sample places<br />
804850020 DBAS DET-basic configuration to be supplemented by<br />
application-specific accessory kits, consisting of a<br />
thermostated aluminum heating block (20 – 300 °C)<br />
with five 65 mm dia. cavities <strong>for</strong> sample vessels,<br />
condenser cooling water distributor and<br />
time-temperature controller<br />
804850023 DE 30 Accessory kit, <strong>for</strong> use with the DBAS basic<br />
configuration, providing all required additional<br />
components <strong>for</strong> the 30 ml Soxhlet extraction<br />
804850024 DE 100 Accessory kit, <strong>for</strong> use with the DBAS basic<br />
configuration, providing all required additional<br />
components <strong>for</strong> the 100 ml Soxhlet extraction<br />
804850025 DFE 100 Accessory kit, <strong>for</strong> use with the DBAS basic<br />
configuration, providing all required additional<br />
components <strong>for</strong> the 100 ml fat extraction, w/ spigots<br />
DBAS + DFE 100<br />
6
Equipment <strong>for</strong> Soxhlet extraction, 6 sample places<br />
804880020 SMX 30 Workstation <strong>for</strong> the 30 ml Soxhlet extraction<br />
of six samples, complete<br />
804880021 SMX 100 Workstation <strong>for</strong> the 100 ml Soxhlet extraction<br />
of six samples, complete, extractors /w<br />
DBAS + DE/DFE SMX 30/SMX 100<br />
Dimensions (H x W x D) approx. 500 x 1000 x 350 mm approx. 500 x 1000 x 350 mm<br />
Weight of complete system approx. 37 kg approx. 34 kg<br />
Line voltage <strong>for</strong> heating block 230 VAC, 50/60 Hz 230 VAC, 50/60 Hz<br />
Power rating of heating block 1500 W 800 W<br />
SMX 100<br />
Extraction systems with linear sample configuration<br />
804880031 R 304 Extraction unit with 4 in-line sample positions, 30 ml<br />
804880032 R 306 Extraction unit with 6 in-line sample positions, 30 ml<br />
804880022 R 106 S Extraction unit with 6 in-line sample positions, 100 ml<br />
804880023 R 104 S Extraction unit with 4 in-line sample positions, 100 ml<br />
804880033 R 254 S Extraction unit with 4 in-line sample positions, 250 ml<br />
804880034 R 256 S Extraction unit with 6 in-line sample positions, 250 ml<br />
R 106 S<br />
<strong>behr</strong>otest® extraction systems with linear<br />
sample configuration are cost-effective<br />
and user-friendly solutions <strong>for</strong> classical<br />
Soxhlet and fat extraction requirements:<br />
Dimensions (W x H x D)<br />
(unit w/o glassware)<br />
Weight<br />
(unit w/o glassware)<br />
Rated voltage<br />
R 304, R 104 S, R 254 R 306, R 106 S, R 256<br />
approx. 53 x 74 x 32 cm<br />
approx. 76 x 74 x 32 cm<br />
15,1 kg 19,8 kg<br />
230 VAC, 50/60 Hz<br />
Power 1440 W 2160 W<br />
• heating at every sample position is<br />
individually adjustable<br />
• a cooling water distributor provides<br />
<strong>for</strong> uni<strong>for</strong>m cooling of all reflux<br />
condensers<br />
• convenient built-in stand <strong>for</strong> storing<br />
the reflux condensers between<br />
extractions<br />
• holder provided <strong>for</strong> secure storage<br />
of the extractors after removal of<br />
the solvent vessel<br />
• S models: Extractors provided with<br />
spigots <strong>for</strong> draining solvent obviate<br />
need to distill solvent be<strong>for</strong>e reuse.<br />
7
Acid Digestion – Sample Preparation <strong>for</strong> Extraction<br />
Extraction following Acid<br />
Digestion –<br />
The Weibull-Stoldt Method<br />
<strong>behr</strong>otest® hydrolysis, complete with:<br />
• Heating unit with linear sample<br />
configuration<br />
• Rack <strong>for</strong> 4 or 6 funnels<br />
The quantitative determination of the fat<br />
content in food is per<strong>for</strong>med by means of<br />
a solvent extraction. The “free fat” is determined<br />
by direct extraction. The “total<br />
• 4 or 6 glass funnels, 100 mm<br />
• PE-bottle, 500 ml, with screwcap<br />
with squirttube<br />
• 100 fluted filter papers<br />
fat” content is composed of the sum of<br />
the “free fat” and the “bound fat,” which<br />
is released by the acid digestion.<br />
• Boiling aids<br />
• Cooling water manifold with condenser<br />
rack and connection tubing<br />
• Beakers ( 600 ml), cold fingers<br />
Hydrolysis units<br />
804880028 HYDRO 1 Hydrolysis unit, complete <strong>for</strong> one sample<br />
804880029 HYDRO 4 Hydrolysis unit, complete <strong>for</strong> 4 samples<br />
HYDRO 6<br />
804880030 HYDRO 6 Hydrolysis unit, complete <strong>for</strong> 6 samples<br />
Technical Specifications<br />
Dimensions<br />
(W x H x D)<br />
HYDRO 1 HYDRO 4 HYDRO 6<br />
approx. 71,5 x 23<br />
x 33<br />
approx. 53 x 74 x<br />
32 cm<br />
Weight 7,5 kg 15,1 kg<br />
(w/o glassware)<br />
Rated voltage<br />
230 VAC, 50/60 Hz<br />
approx. 76 x 74 x<br />
32 cm<br />
19,8 kg<br />
(w/o glassware)<br />
Power 450 W 1440 W 1960 W<br />
Accessories <strong>for</strong> Soxhlet Extraction<br />
Stock no. Model Description<br />
Glassware Setups<br />
Extraction<br />
Reaction<br />
vessel<br />
Extractor<br />
Condenser<br />
30 ml 100 ml 30 ml RFK 30<br />
100 ml 250 ml 100 ml RFK 100<br />
250 ml 500 ml 250 ml RFK 250<br />
804841031 EZ 30 Soxhlet ectractor, 30 ml<br />
804830290 PTFE 29 PTFE joint sleeves <strong>for</strong> EZ 30<br />
804841033 EX 30 HS Extraction thimbles <strong>for</strong> EZ 30 extractor, package of 25<br />
804841032 EZ 100 Soxhlet extractor, 100 ml<br />
804841035 EZ 100/HAHN Soxhlet extractor, 100 ml, with spigot<br />
804841034 EX 100 HS Extraction thimbles <strong>for</strong> EZ 100 (HAHN) extractor,<br />
package of 25<br />
804841039 EZ 250 Soxhlet extractor, 250 ml<br />
804841038 EZ 250/HAHN Soxhlet extractor, 250 ml, with spigot<br />
804841040 EX 250 HS Extraction thimbles <strong>for</strong> EZ 250 (HAHN) extractor,<br />
package of 25<br />
804830450 PTFE 45 PTFE joint sleeves <strong>for</strong> EZ 100 and EZ 100/HAHN,<br />
EZ 250 and EZ 250/HAHN<br />
804841011 RFK 30 Reflux condenser <strong>for</strong> 30 ml extractor<br />
804851070 RFK 100 Reflux condenser <strong>for</strong> 100 ml extractors (EZ 100 or EZ<br />
100/HAHN)<br />
804841037 RFK 250 Reflux condenser <strong>for</strong> 250 ml extractors (EZ 250 or EZ<br />
250/HAHN)<br />
8
Determination of alcohol and volatile acids<br />
Units <strong>for</strong> the determination of alcohol content and the determination of volatile acids<br />
in wine and other alcoholic beverages. Complete with glassware, including volumetric<br />
flask and pycnometer.<br />
The <strong>behr</strong> S 2A, based on its speed of operation, is especially suited <strong>for</strong> applications<br />
involving a high sample workload.<br />
<strong>behr</strong> S 2 A<br />
Rated voltage:<br />
Power:<br />
Cooling water<br />
consumption:<br />
Distillation time:<br />
Storage container:<br />
Display:<br />
230 VAC, 50 Hz<br />
1700 W<br />
approx. 5 l/min<br />
approx. 2 ... 3 min per sample<br />
any size,<br />
recommendation: <strong>behr</strong>otest® set of canisters<br />
LCD<br />
Programs: 1<br />
S 2 A<br />
Dimensions<br />
(W x H x D in mm)<br />
Weight:<br />
410 x 675 x 410<br />
32 kg<br />
804852200 WE 1/H Single steam generator, 400 W, with additional sample<br />
heating.<br />
804852103 GSABP Glassware accessory kit <strong>for</strong> the determination of<br />
alcohol by distillation into a pycnometer<br />
804852102 GSAB Glassware accessory kit <strong>for</strong> the determination of<br />
alcohol by distillation into a volumetric flask.<br />
Pycnometer included.<br />
804849010 S 2A Steam distillation apparatus <strong>for</strong> the alcohol<br />
determination, 1700 W, manual operation, Distillation<br />
into a volumetric flask. Pycnometer included.<br />
<strong>behr</strong>otest ® WE 1/H<br />
Rated voltage:<br />
Power:<br />
Cooling water<br />
consumption:<br />
Distillation time:<br />
Storage container:<br />
Dimensions<br />
(W x H x D in mm)<br />
Weight:<br />
230 VAC, 50 Hz<br />
400 W<br />
approx. 5 l/min<br />
approx. 10 min per sample<br />
any size,<br />
recommendation: <strong>behr</strong>otest® set of canisters<br />
290 x 670 x 380<br />
12,8 kg<br />
WE 1/H + GSAB<br />
9
Determination of hydroxyproline<br />
RH 6<br />
Digestion apparatus <strong>for</strong> the determination of hydroxyproline (connective tissue)<br />
content in meat and sausage.<br />
804880024 RH 6 <strong>behr</strong>otest ® six sample digestion apparatus with energy<br />
control <strong>for</strong> determination of hydroxyproline content,<br />
complete with glassware<br />
Dimensions<br />
(W x H x D)<br />
Weight<br />
Rated voltage<br />
Power<br />
RH 6<br />
approx.<br />
76 x 74 x 32 cm<br />
19,8 kg<br />
(w/o glassware)<br />
230 VAC, 50/60 Hz<br />
1960 W<br />
804880035 SMH 6 <strong>behr</strong>otest ® six sample digestion apparatus <strong>for</strong><br />
determination of hydroxyproline content, complete with<br />
heating block, cooling water manifold, temperature<br />
controller and glassware<br />
804880036 SMH 12 <strong>behr</strong>otest ® twelve sample digestion apparatus <strong>for</strong><br />
determination of hydroxyproline content, complete with<br />
heating block, cooling water manifold, temperature<br />
controller and glassware<br />
146012<br />
SMH 6 SMH 12<br />
Dimensions (W x H x D) approx. 400 x 1000 x 650 mm approx. 400 x 1000 x 650 mm<br />
Weight of complete system approx. 32 kg approx. 34 kg<br />
Line voltage <strong>for</strong> heating block 230 VAC, 50/60 Hz 230 VAC, 50/60 Hz<br />
Power rating of heating block 800 W 1500 W<br />
SMH 12<br />
10
Determination of the saponification number<br />
and the hydroxyl number<br />
BE 6<br />
Digestion units with six or twelve sample positions <strong>for</strong> determination of, <strong>for</strong> example,<br />
the saponification number or the hydroxyl number.<br />
804880025 <strong>behr</strong>otest ® six sample digestion unit, complete with heating block,<br />
temperature controller and glassware.<br />
804880026 <strong>behr</strong>otest ® twelve sample digestion unit, complete with heating block,<br />
temperature controller and glassware.<br />
BE 6 BE 12<br />
Dimensions (W x H x D) approx. 310 x 900 x 380 mm approx. 310 x 900 x 380 mm<br />
Weight of complete system approx. 28 kg approx. 30 kg<br />
Line voltage <strong>for</strong> heating block 230 VAC, 50/60 Hz 230 VAC, 50/60 Hz<br />
Power rating of heating block 800 W 1500 W<br />
Determination of total SO 2<br />
Systems <strong>for</strong> the liberation and distillation of SO 2 in one or six samples, with magnetic<br />
stirrer(s). Choice of one or two absorption vessels per sample is available.<br />
Sample vessel: 500 ml round-bottom flask. Other sizes available on request.<br />
804800501 KSO 2 Kompakt-apparatus <strong>for</strong> <strong>for</strong> the determination of total<br />
SO 2<br />
, with 2 absorption vessels and magnetic stirrer.<br />
804880027 SO 2-6 Apparatus <strong>for</strong> determination of SO 2<br />
in wine in up to 6<br />
simultaneous sample places. 2 absorption vessels,<br />
magnetic stirrer.<br />
804800502 AKO 300 Heating unit <strong>for</strong> destruction of the hydrogen peroxide<br />
prior to titration, complete with Erlenmeyer flask<br />
KSO 2 KSO 2-6<br />
Approx. dimensions<br />
(H x W x D in cm)<br />
71,5 x 23 x 33 100 x 70 x 43 cm<br />
Weight 7,5 kg 48 kg (w/o glassware)<br />
Line voltage 230 VAC, 50/60 Hz 230 VAC, 50/60 Hz<br />
Power rating 450 W 2000 W<br />
KSO 2<br />
11
Determination of water content by<br />
azeotropic distillation<br />
Apparatus <strong>for</strong> the determination of water content by azeotropic distillation.<br />
Suitable <strong>for</strong> non-homogeneous, irregularly shaped <strong>foodstuffs</strong>, such as dried vegetables,<br />
dried fruit, etc.<br />
804800500 KWA 500 <strong>behr</strong>otest ® Kompakt apparatus <strong>for</strong> water content<br />
determination. Complete with stand, heating element<br />
and tubing connections.<br />
804850020 DBAS DET-basic configuration to be supplemented by<br />
application-specific accessory kits, consisting of a<br />
thermostatted aluminum heating block (20 – 300 °C)<br />
with five 65 mm dia. cavities <strong>for</strong> sample vessels,<br />
condenser cooling water distributor and<br />
time-temperature controller<br />
804850027 DWA 500 Accessory kit DWA 500, <strong>for</strong> use with the DBAS basic<br />
configuration, <strong>for</strong> the determination of water content<br />
KWA 500<br />
<strong>behr</strong> <strong>equipment</strong> <strong>for</strong> <strong>foodstuffs</strong> <strong>analysis</strong><br />
<strong>behr</strong> Labor-Technik - that means over 50<br />
years of experience in the development,<br />
production and sales of laboratory<br />
<strong>equipment</strong>. Over this half-century a small<br />
family-owned business developed into an<br />
internationally active corporation. Today,<br />
customers all over the world prize the<br />
quality, reliability and cost-effectiveness<br />
of our <strong>equipment</strong>.<br />
Production of laboratory <strong>equipment</strong> <strong>for</strong><br />
<strong>foodstuffs</strong> <strong>analysis</strong> is counted among our<br />
core activities. <strong>behr</strong> Labor-Technik has<br />
ranked <strong>for</strong> many years among the leading<br />
German producers.<br />
Routine quality control of basic<br />
<strong>foodstuffs</strong> is conducted world-wide<br />
employing standard analytical methods<br />
For many of these standard methods, <strong>behr</strong><br />
Labor-Technik GmbH offers <strong>equipment</strong><br />
and apparatuses, which offer the user<br />
safety and convenience of use in the daily<br />
laboratory routine.<br />
Sample Material<br />
Fruit, vegetables, grain,<br />
starches<br />
Meat, fish, fowl<br />
Dairy products<br />
Beverages<br />
Determination<br />
Water determination in dried vegetables, dried fruit,<br />
sauerkraut, etc..<br />
Proteins (Kjeldahl nitrogen determination)<br />
Extraction<br />
Saponification number<br />
Sulfur dioxide (SO 2 )<br />
Hydrolyse<br />
Extraction<br />
Proteins (Kjeldahl nitrogen determination)<br />
Saponification number<br />
Determination of sodium chloride content<br />
Hydroxyproline<br />
Extraction<br />
Proteins (Kjeldahl nitrogen determination)<br />
Alcohol in wine, etc.<br />
Sulfur in wine<br />
Volatile acids<br />
Cyclamate<br />
The design of <strong>behr</strong> <strong>equipment</strong> <strong>for</strong><br />
<strong>foodstuffs</strong> <strong>analysis</strong> is constantly<br />
influenced by dialog with users. This<br />
results in product improvements, which,<br />
in individual instances, have led to<br />
• Simplification of daily laboratory<br />
work,<br />
• Shortening of the time required <strong>for</strong><br />
the <strong>analysis</strong>,<br />
• Simplifications, which have rendered<br />
complicated and costly accessories<br />
unnecessary.<br />
Solutions with a payoff <strong>for</strong> you<br />
12<strong>behr</strong><br />
Labor-Technik<br />
<strong>behr</strong> Labor-Technik GmbH • Spangerstraße 8 • D – 40599 Düsseldorf<br />
Tel.: (+49) (0) 211 – 7 48 47 17 • Fax: (+49) (0) 211 – 7 48 47 48 • eMail: info@<strong>behr</strong>-labor.com • Internet: www.<strong>behr</strong>-labor.com<br />
We reserve the right to make technical alterations and accept no responsibility <strong>for</strong> inadvertent errors.